MANUAL: EF1 RC MONITOR

Similar documents
MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

MANUAL: Jumbo Siamese and Jumbo Wye

MANUAL: Jumbo Gate Valve

MANUAL: 5-WAY MANIFOLD

MANUAL: SHO-FLOW Flow Meter Operations

INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE. Monitor Mounted Operator Station SECTION 4.2. Tethered Operator Station (Y4E-CT-##)

MANUAL: PROTECTOR STATION MONITOR

MANUAL: LDH GATED WYE

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

MANUAL: LDH GATED WYE

MANUAL: OASIS HYDRANT ASSIST VALVE

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

MANUAL: HYDRANT MASTER

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Models: C62/63/64-A/D

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

MANUAL: CROSSFIRE Monitor

WHEATLEY Series 500 Swing Check Valve

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Manual: GPK1 - Gin Pole Kit Accessory for the ARRS1-AMKUS Rope Rescue System

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

CROSSFIRE MANUAL: WITH SAFE-TAK 1250 BASE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE DANGER. TASK FORCE TIPS, Inc. DANGER

HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

III. Identify the initial installation requirements for standpipe systems

MANUAL: Low Profile Ball Intake Valve

MANUAL: LDH VALVED APPLIANCES

FOR SAFE OPERATION AND MAINTENANCE

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Interface Devices, Inc. Hydraulic Mini Mule

TITAN FLOW CONTROL, INC.

Model ASSEMBLY and OPERATING INSTRUCTIONS

MANUAL: CROSSFIRE Monitor With Stow-A-Way 800 Base

KJ4000 Operating Instructions & Parts Manual NSN

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

FLANGED TWO-PIECE BALL VALVES

AIR INLINE METAL SHEAR

Model PSI Compressor with 3-Gallon Air Tank 12VDC

APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, ANDMAINTENANCE INSTRUCTIONS

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

200 PSI COMPRESSORS - MODEL NUMBERS

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

IMPORTANT SAFETY INSTRUCTIONS

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

MANUAL: BLITZFIRE Portable Monitor Series

MANUAL: LDH VALVED APPLIANCES

1 DRIVE INDUSTRIAL IMPACT WRENCH

FLANGED TWO-PIECE BALL VALVES

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

MANUAL BE SERIES Test Benches

Index Table. Model 794. Installation, Operating and Maintenance Instructions

3/8" Dr. Air Butterfly Impact Wrench

INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

Pressure Dump Valve Service Kit for Series 3000 Units

Geotech 1.66 Reclaimer

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

400C & 450C DUAL PERFORMANCE VALUE PACKS

444C DUAL PERFORMANCE VALUE PACK

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Automatic Non-freeze Valve NF6

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Pressure Dump Valve Service Kit for Series 2300 Units

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

HYDRAULIC WINCH FOR AUGERS UP TO WR10 X 71 / W130 X 41 ASSEMBLY & OPERATION MANUAL

Pressure Relief Valve Instruction Manual

2000 lb manual winch

H4802, H4802-1, H , and Pole Tampers

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

COMPACT METAL bender 99826

100C Air Compressor Kit

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

BUTTERFLY VALVES Series 800

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

750 Cable Cutter INSTRUCTION MANUAL

Bermad Pressure Reducing. Model: 42T

Installation and Operating Manual

Vertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

ROPV R40 E Series User Manual

PERSONAL AIR BREATHING UNIT

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

FIREFIGHTING EQUIPMENT

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Direct Operated Precision Regulator Modular Style. Standard Specifications

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Hydraulic Punch Drivers

Vessel Installation and Operating Manual

1700ESL Kamvalok Coupler

Transcription:

MANUAL: EF1 RC MONITOR INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE DANGER Understand manual and documents in additional literature before use. Operation of this device without understanding the manual and receiving proper training is a misuse of this equipment. Obtain safety information at www.tft com/serial-number This instruction manual is intended to familiarize firefighters and maintenance personnel with the operation, servicing and safety procedures associated with the EF1 RC Monitor series. This manual should be kept available to all operating and maintenance personnel. See Section 3.2.2 for Flow/Pressure Operating Envelope ef1 rc 219-462-6161 www.tft.com MADE IN USA MODEL# SERIAL# www.tft.com-y123456 Y1165 TASK FORCE TIPS, INC. MADE IN USA www.tft.com 3701 Innovation Way, Valparaiso, IN 46383-9327 USA 800-348-2686 219-462-6161 Fax 219-464-7155

DANGER PERSONAL RESPONSIBILITY CODE The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following: 1. Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times. 2. It is your responsibility to read and understand any user s instructions, including purpose and limitations, provided with any piece of equipment you may be called upon to use. 3. It is your responsibility to know that you have been properly trained in Firefighting and /or Emergency Response and in the use, precautions, and care of any equipment you may be called upon to use. 4. It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use. 5. It is your responsibility to know that your equipment is in operable condition and has been maintained in accordance with the manufacturer s instructions. 6. Failure to follow these guidelines may result in death, burns or other severe injury. Fire and Emergency Manufactures and Service Association P.O. Box 147, Lynnfield, MA 01940 www.femsa.org FEMSA ADDITIONAL MANUALS MANUAL: Remote Control (RC) Monitor Electrical Controls Supplemental Instructions for use with RC Monitor Manual INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE DANGER Understand manual before use. Operation of this device without understanding the manual and receiving proper training is a misuse of this equipment. Obtain safety information at www.tft. com/serial-number SECTION 3.0 SECTION 4.9 General Information and Specifications SECTION 4.0 Electrical Controls Installation and Operation SECTION 4.1 Monitor Mounted Operator Station SECTION 4.2 Panel Mount Operator Station (Y4E-RP) SECTION 4.3 Panel Mount With Display Operator Station (Y4E-RP-D) SECTION 4.4 Tethered Operator Station (Y4E-CT-##) SECTION 4.5 Tethered Operator Station With Display (Y4E-CT-##-D) SECTION 4.6 Wireless Operator Station (YE-RF-##) SECTION 4.7 Wireless Operator Station With Display (YE-RF-##-D) SECTION 4.8 Joystick Operator Station (Y4E-JS) TASK FORCE TIPS, INC. MADE IN USA www.tft.com Toggle Switch Monitor Operator Station (Y4E-TS) SECTION 4.10 Monitor Communication Interface Control (Y4E-COMM) SECTION 4.11 Monitor Position Display (Y4E-DISP) SECTION 4.12 Remote Auxiliary Function Interface Control (YE-REMAUX) SECTION 4.13 Electric RC Monitor Aerial Truck Installation SECTION 4.14 Multiplex Interface Control (YE-CAN#) SECTION 4.15 Ethernet Interface Control SECTION 4.16 Electric Nozzle Actuator SECTION 4.17 Valve Kits (YE-VK-PH) SECTION 5.0 Troubleshooting 3701 Innovation Way, IN 46383-9327 USA 800-348-2686 219-462-6161 Fax 219-464-7155 Copyright Task Force Tips, Inc. 2008-2016 LIY-500 May 31, 2016 Rev11 MANUAL: Remote Control (RC) Monitor Electrical Controls LIY-500 2

Table Of Contents 1.0 MEANING OF SAFETY SIGNAL WORDS 2.0 SAFETY 3.0 GENERAL INFORMATION 3.1 PART IDENTIFICATION 3.2 SPECIFICATIONS 3.2.1 MECHANICAL 3.2.2 SAFE OPERATING ENVELOPE 3.3 USE WITH SALT WATER 3.4 INLETS AND OUTLET OPTIONS 3.5 OVERALL DIMENSIONS 4.0 INSTALLATION 4.1 STRUCTURAL REQUIREMENTS 4.2 TRAVEL RANGES 4.2.1 TRAVEL STOPS 4.3 NOZZLE INSTALLATION 4.4 PRESSURE GAGE 4.5 DRAINING RESIDUAL WATER 5.0 SPRAY TRAJECTORY ADJUSTMENT 6.0 OPERATION OF RC MONITORS 7.0 RECOMMENDED PARK POSITION 7.1 OVERRIDE HEX DRIVE 8.0 CHARACTERISTICS 8.1 STACKED TIPS 8.2 EF1 RC MONITOR FRICTION LOSS 9.0 DRAWINGS AND PARTS LIST 10.0 WARRANTY 11.0 MAINTENANCE 11.1 LUBRICATION 11.2 TROUBLESHOOTING 11.3 REPAIR 12.0 ANSWERS TO YOUR QUESTIONS 13.0 INSPECTION CHECKLIST 3

1.0 MEANING OF SAFETY SIGNAL WORDS A safety related message is identified by a safety alert symbol and a signal word to indicate the level of risk involved with a particular hazard. Per ANSI standard Z535-2011, the definitions of the four signal words are as follows: DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. indicates a hazardous situation which, if not avoided, could result in death or serious injury. indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE is used to address practices not related to physical injury. 2.0 SAFETY The operation of this monitor can be dangerous. The following must be observed at all times. An inadequate supply of nozzle pressure and/or flow will cause an ineffective stream and can result in injury, death, or loss of property. See flow graphs or call 800-348-2686 for assistance. Injury or death may occur by attempting to use a damaged monitor. Before using the monitor, inspect it for damage resulting from, but not limited to: Failure to drain monitor followed by exposure to freezing conditions. See section DRAINING RESIDUAL WATER for instructions. Exposure of monitor to temperatures in excess of 160 F (71 C). Missing parts, physical abuse, exposure to severe chemicals. Deformed or cracked flanges damaged as a result of improper installation. - Excessive bolt torque - Wrong tightening sequence Injury can result from an inadequately supported monitor. The monitor mount must be capable of supporting 145 lbs (66 kg) of nozzle reaction force. The stream exiting a monitor is very powerful and capable of causing injury and property damage. Make sure the monitor is securely attached to the base and pointing in a safe direction before water to the monitor is turned on. Use care in directing the stream. The monitor may be damaged if frozen while containing sufficient amounts of water. Such damage may be difficult to detect visually and can lead to possible injury or death. Any time the monitor is subject to possible damage from freezing, it must be hydrostatically tested by qualified personnel before being considered safe for use. Keep hands and fingers away from moving parts of the oscillating unit when water is flowing. There are moving parts that can pinch fingers and hands. NOTICE This equipment is intended for use by trained personnel for firefighting. Their use for other purposes may involve hazards not addressed by this manual. Seek appropriate guidance and training to reduce risk of injury. The electric monitor may be remotely operated. The electric drives are current limited but may still produce enough force to cause injury. Keep hands and fingers away from pinch points on the monitor. Do not use the manual override while the electric controls are in operation. The electric drives produce enough torque to cause injury. Exceeding the operating envelope of the monitor can result in injury. Observe safe operation by staying within the published limits. On many vehicle installations, the monitor is the highest point on the apparatus. Be sure there is sufficient clearance to safely pass under any doors or overhead obstructions. Always check parked position of the monitor before moving. To prevent mechanical damage, do not drop or throw equipment. 4

3.0 GENERAL INFORMATION The EF1 RC monitor is extremely compact, yet it has a large 1-½ inch waterway, capable of flowing up to 200 gpm, making it the ideal forestry bumper turret. Waterway with turning vane has only 15 psi (1.3 bar) friction loss at 200 gpm (760 l/min). Elevation range is 90 above horizontal to 45 below. Horizontal travel is 270 (135 either side of a center position). Field changeable horizontal travel stops are factory set to give 180 (90 either side of a center position). Designed for 12 VDC or 24 VDC operation, selection is automatic. The motor control circuits use position encoders and current limiting to protect the drive train at the ends of travel. Unit has waterproof factory installed plug on power wire for easy removal or reinstallation. Electric drives and control box are waterproof. Main waterway made from hardcoat anodized ANSI 356-T6 aluminum. Silver powder coat finish. Various inlets are available. 3.1 PART IDENTIFICATION REMOVE CAP TO ACCESS MANUAL OVERRIDE HEX NUT FOR ELEVATION ELEVATION GREASE FITTING TURNING VANE OUTLET HORIZONTAL GREASE FITTING Y1165 ELECTRONICS ENCLOSURE ef1 rc 219-462-6161 www.tft.com MADE IN USA MODEL# SERIAL# www.tft.com-y123456 MODEL & SERIAL NUMBER ON LABEL INLET FLANGE HORIZONTAL ROTATION TRAVEL STOP SEE SECTION 4.2 Fig. 3.1 EF1 RC Monitor Part Identification 5

3.2 SPECIFICATIONS 3.2.1 MECHANICAL Electric US METRIC Weight 14.2 lbs 6.5 kg Min. Flow Area 1.5 Inlet 1.77 in 2 11.4 cm 2 Min. Flow Area 2.0 Inlet 3.14 in 2 20.3 cm 2 Max Flow See figure 3.2.2 Max Operating Pressure 200 psi 14 bar Horizontal Travel Range 3.2.2 SAFE OPERATING ENVELOPE 270 (135 left and right) Materials Used ANSI A356.0-T6 Aluminum, Stainless Maximum Torque Elevation 26 ft lbs 35 n m Maximum Torque Horizontal 26 ft lbs 35 n m Speed Elevation 33 deg/sec Speed Horizontal 33 deg/sec 225 EF1 Opera ng Envelope Flow (lpm) 0 200 400 600 800 1000 1200 200 14 175 150 K=2 NOZZLE MONITOR LOSS Monitor Inlet Pressure 12 10 Pressure (psi) 125 100 K=8 NOZZLE K=15 NOZZLE 8 6 Pressure (bar) 75 50 K=20 NOZZLE Nozzle Pressure 4 25 2 0 0 50 100 150 200 250 300 Flow (gpm) Nozzle A flows 20 gpm (80 l/min) at 100 psi (7 bar), K factor = 2 Nozzle B flows 80 gpm (300 l/min) at 100 psi (7 bar), K factor = 8 Nozzle C flows 150 gpm (570 l/min) at 100 psi (7 bar), K factor = 15 Nozzle D flows 200 gpm (760 l/min) at 100 psi (7 bar), K factor = 20 Figure 3.2.2 Safe Operating Envelope 0 6

Y1165 3.3 USE WITH SALT WATER Use with salt water is permissible provided the monitor is thoroughly cleaned with fresh water after each use. The service life of the monitor may be shortened due to the effects of corrosion and is not covered under warranty. 3.4 INLET AND OUTLET OPTIONS Available inlets and outlets are shown below and should be specified at time of order. Note: Outlet thread options are machined into elbow. OUTLET OPTIONS OPTION # THREAD ELBOW 1 1.5" NH MALE Y1311ANF 2 1.5 NPSH MALE Y1311AIF 3 1.5 BSP MALE Y1311ABF ef1 rc 219-462-6161 www.tft.com MADE IN USA MODEL# SERIAL# www.tft.com-y123456 2.0" BSP FEMALE (Y1403) 1.5" BSP FEMALE (Y1402) 2.0" ANSI 150 (Y1417) 1.5" ANSI 150 (Y1412) 2.0" NPT FEMALE (Y1401) 1.5" NPT FEMALE (Y1400) INLET OPTION Fig 3.4a Inlets and Outlets Weight 2.0" BSP FEMALE (Y1403) 2.1 lb 0.95 kg 1.5" BSP FEMALE (Y1402) 2.1 lb 0.95 kg 2.0" ANSI 150 (Y1417) 3.0 lb 1.4 kg 1.5" ANSI 150 (Y1412) 2.2 lb 1.0 kg 2.0" NPT FEMALE (Y1401) 2.1 lb 0.95 kg 1.5" NPT FEMALE (Y1400) 2.1 lb 0.95 kg Figure 3.4b Inlet Weight 7

3.5 OVERALL DIMENSIONS 135 LEFT 2.2 [55mm] 7.0 [178mm] 135 RIGHT 7.0 [178mm] SWING 90 10.8 [276mm] 45 3.4 [85mm] 2.7 [69mm] INLET OPTION Fig 3.5a EF1 RC Monitor Dimensions Additional Overall Height 2.0" BSP FEMALE (Y1403) 2.7 in 69 mm 1.5" BSP FEMALE (Y1402) 2.7 in 69 mm 2.0" ANSI 150 (Y1417) 1.8 in 45 mm 1.5" ANSI 150 (Y1412) 1.7 in 43 mm 2.0" NPT FEMALE (Y1401) 2.7 in 69 mm 1.5" NPT FEMALE (Y1400) 2.7 in 69 mm Fig 3.5b Inlet Heights 8

4.0 INSTALLATION See Remote Control (RC) Monitor Electrical Controls Supplemental Instructions (LIY-500) For RC monitor. 4.1 STRUCTURAL REQUIREMENTS The structure that the EF1 RC Monitor is mounted to must withstand the internal pressure of the monitor as well as shear and bending forces due to nozzle reaction. Nozzle reaction can be as high as 150 lbs (70 kg) (200 gpm at 200 psi). For flanged connections the use of flat flanges without raised faces is recommended. Use a ring gasket as defined in ASME 16.21 or ISO 7483. Tighten flange bolts in an alternating sequence as shown in figure 4.1. Tighten sequentially each bolt or stud three times with 30%, then 60%, and finally 100% of the specified torque. Tighten to 76-80 ft-lb (100-110 Newton-Meters). FLANGE TYPE OUTSIDE THICKNESS DIAMETER 3 BOLT HOLE CIRCLE 1 2 4 Tighten Sequentially Each Bolt Three Times Fig 4.1 Flange Bolt Tightening Sequence # OF BOLTS SIZE OF BOLTS TORQUE ON BOLTS in mm in mm in mm in mm ft-lb N-m 1.5 ANSI 150 5 127 0.63 16 3.88 98.4 4 1/2 13 20-40 27-54 2.0 ANSI 150 6 152.4 0.75 19 4.75 120.7 4 5/8 16 40-70 54-95 4.2 TRAVEL RANGES The EF1 RC Monitor is available with various inlet fittings. These Inlet Adapters must be oriented upon installation so the EF1 RC will point in the desired direction. Figure 3.4A shows examples of Inlet Adaptors. Travel ranges relative to the Straight Ahead Reference Mark are shown in Figure 4.2. Figure 4.2.1 gives the location of the travel stops. 135 LEFT 90 45 135 RIGHT HORIZONTAL TRAVEL ELEVATION TRAVEL Fig 4.2 Travel Ranges Relative to Straight Ahead Reference Mark 9

Y1165 4.2.1 TRAVEL STOPS Vertical Travel Stops are cast into the elbow of the monitor. Instructions on how to install horizontal travel stops are shown below. Y1165 ef1 rc 219-462-6161 www.tft.com MADE IN USA MODEL# SERIAL# www.tft.com-y123456 1. Rotate horizontal travel stop 90 one direction and insert into coupling track. 2. Rotate back to original position ensuring the letter is located at the top of the travel stop. 3. Rotate the monitor to the desired position, position the travel stop next to the Monitor's Stop Ear. 4. Tighten set screws to lock the travel stop position. 4.3 NOZZLE INSTALLATION The nozzle is simply screwed onto the monitor s exit threads. 4.4 PRESSURE GAGE There is a raised boss on the front of the monitor. This raised boss is not machined from the factory but may be drilled and tapped for ¼ NPT threads if a pressure gage is desired on the monitor. Fig 4.2.1 Travel Stops The nozzle threads must match the threads of the monitor elbow in both size and type. Mismatched or damaged threads may cause the nozzle to leak or uncouple under pressure and could cause injury. Do not connect aluminum to brass or brass to aluminum. Dissimilar metals coupled together can cause galvanic corrosion that will freeze the threaded joint or cause complete loss of thread engagement. If dissimilar metals must be coupled together, the effects of corrosion can be greatly delayed by various coatings on the metal such as powder paint, hard anodizing, or silicone grease. ef1 rc 219-462-6161 www.tft.com MADE IN USA MODEL# SERIAL# www.tft.com-y123456 Fig 4.4 Pressure Gage 10

4.5 DRAINING RESIDUAL WATER There is no drain on the EF1 RC Monitor itself. A drain valve should be installed on the piping to which the monitor is attached. All monitors, valves, and standpipes exposed to freezing conditions must be drained immediately following use to prevent damage. To drain a standpipe, a drainage port must be opened underground below the frost depth to keep water out of the standpipe until the next use. 5.0 SPRAY TRAJECTORY ADJUSTMENT 6.0 OPERATION OF RC MONITORS Injury can result from the monitor changing direction due to an off center nozzle reaction. An off center nozzle reaction may be caused by debris in the nozzle causing an asymmetrical stream. See Remote Control (RC) Monitor Electrical Controls Supplemental Instructions LIY-500 for operation of the EF1 RC Monitor. 7.0 RECOMMENDED PARK POSITION For truck mounted applications it is recommended that the monitor be parked in a position such that the monitor s nozzle rests against a bracket or support surface. If a support surface is not available, run the elevation against one of its travel stops to take some of the backlash out of the gear drive. This will minimize bouncing of the nozzle when the apparatus is traveling. Always be sure the monitor is properly parked before moving the truck and know the overall height to avoid damage from overhead obstructions such as doors or bridges. See Remote Control (RC) Monitor Electrical Controls Supplemental Instructions (LIY-500) for information on programming, OSCILLATE and PARK position of the EF1 RC monitor. 7.1 OVERRIDE HEX DRIVE In the event of electrical system failure on the monitor or fire truck, the EF1 RC Monitor is factory supplied with a hex drive so a 1/4 hex wrench may be used for manual override. Pry the dust caps off from the horizontal or vertical shafts to access the hex drives. ¼ Hex Wrench Fig 7.1 Wrenching Hexes on Drive Shafts 11

8.0 CHARACTERISTICS 8.1 STACKED TIPS NOZZLE DIAMETER (GPM) NOZZLE INLET PRESSURE 50 PSI 80 PSI 100 PSI 150 PSI 175 PSI (LBS) (GPM) (LBS) (GPM) (LBS) (GPM) (LBS) (GPM) (LBS) 1/2 INCH 53 20 66 31 74 39 91 59 98 69 5/8 INCH 82 31 104 49 116 61 142 92 153 107 3/4 INCH 118 44 149 71 167 88 205 132 221 155 NOZZLE DIAMETER (l/min) NOZZLE INLET PRESSURE 4 BAR 6 BAR 8 BAR 10 BAR 12 BAR (KG) (l/min) (KG) (l/min) (KG) (l/min) (KG) (l/min) (KG) 12 MM 190 9 230 14 270 18 300 23 330 28 16 MM 340 16 420 25 480 33 540 41 590 49 19 MM 480 23 590 35 680 46 760 58 830 69 8.2 EF1 MONITOR FRICTION LOSS Fig. 8.1 Stacked Tips Flow Table LOSS (PSI) 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 (LPM) 0 200 400 600 800 1000 1200 2 1.5 1 0.5 0 0 50 100 150 200 250 300 (GPM) LOSS (BAR) Fig 8.2 Friction Loss 12

Y1165 9.0 DRAWING & PARTS LIST 2 1 3 4 5 6 7 8 9 10 12 13 14 15 16 17 19 18 20 21 22 23 24 38 37 11 36 35 34 33 32 ef1 rc 219-462-6161 www.tft.com MADE IN USA MODEL# SERIAL# www.tft.com-y123456 13 14 15 25 16 26 27 28 29 29 31 30 ITEM # DESCRIPTION QTY PART # 1 BRAND LABEL 1 Y5703 2 LABEL 1 ZB1069 3 O-RING-006 5 VO-006 4 M4-0.7 X 25MM SOCKET 5 VTM4-0.7SH25 HEAD CAP SCREW 5 ENCLOSURE LID 1 Y1116 6 O-RING-006 1 VO-006 7 O-RING-262 1 VO-262 8 6-32 X 3/16 SOCKET HEAD 4 VT06-32SH188 CAP SCREW 9 SIGNAL AND COMMUNICA- 1 Y5010 TION BOARD 10 MOTOR CONTROL BOARD 1 Y5000 11 CIRCUIT BOARD STANDOFF 2 Y5533 12 HEX PLUG 1 Y5248 13 GREASE FITTING 1/4-28 2 VT25-28ZERK 14 3/8-24 X 3/8 SOCKET SET 4 VT37-24SS375 SCREW 15 BALL 5/16" TORLON 100 VB.312TO 16 O-RING-229 2 VO-229 17 ELBOW 1 See Fig 3.4 18 STRAIN RELIEF 1 Y5245 19 STRAIN RELIEF 1 Y5205 ITEM # DESCRIPTION QTY PART # 20 MOTOR MOUNT RETAINER 2 Y1910 21 DRIVE SHAFT SUBASSEMBLY 2 Y1915 22 SNAP RING 2 VR4220 23 O-RING-215 2 VO-215 24 CAP 2 Y1161 25 NAME LABEL 1 Y1165 26 1/4-20 X 3/8 BUTTON HEAD 1 VT25-20BH375 CAP SCREW 27 3/8 LOOP CLAMP 1 Y4655 28 TRAVEL STOP RIGHT 1 Y1414 29 1/4-20 X 5/16 SOCKET SET 4 VT25-20SS312 SCREW 30 RIGID BASE 1.5" ANSI 150 1 See Fig 3.4 31 TRAVEL STOP LEFT 1 Y1413 32 8-32 X 3/8 SOCKET HEAD CAP 2 VT08-32SH375 SCREW 33 STOP EAR 1 Y1415 34 10-32 X 1/4 SET SCREW 1 VT10Y32SS250 35 LOWER SECTION 1 Y1110 36 M4-0.7 X 8MM SOCKET HEAD 8 VTM4-0.7SH8 CAP SCREW 37 MOTOR MOUNT 2 Y1164 38 GEAR MOTOR 2 Y6000 13

10.0 WARRANTY Task Force Tips, Inc., 3701 Innovation Way, Valparaiso, Indiana 46383-9327 USA ( TFT ) warrants to the original purchaser of its nozzles and other equipment ( equipment ), and to anyone to whom it is transferred, that the equipment shall be free from defects in material and workmanship during the five (5) year period from the date of purchase. TFT s obligation under this warranty is specifically limited to replacing or repairing the equipment (or its parts) which are shown by TFT s examination to be in a defective condition attributable to TFT. To qualify for this limited warranty, the claimant must return the equipment to TFT, at 3701 Innovation Way, Valparaiso, Indiana 46383-9327 USA, within a reasonable time after discovery of the defect. TFT will examine the equipment. If TFT determines that there is a defect attributable to it, it will correct the problem within a reasonable time. If the equipment is covered by this limited warranty, TFT will assume the expenses of repair. If any defect attributable to TFT under this limited warranty cannot be reasonably cured by repair or replacement, TFT may elect to refund the purchase price of the equipment, less reasonable depreciation, in complete discharge of its obligations under this limited warranty. If TFT makes this election, claimant shall return the equipment to TFT free and clear of any liens and encumbrances. This is a limited warranty. The original purchaser of the equipment, any person to whom it is transferred, and any person who is an intended or unintended beneficiary of the equipment, shall not be entitled to recover from TFT any consequential or incidental damages for injury to person and/or property resulting from any defective equipment manufactured or assembled by TFT. It is agreed and understood that the price stated for the equipment is in part consideration for limiting TFT s liability. Some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above may not apply to you. TFT shall have no obligation under this limited warranty if the equipment is, or has been, misused or neglected (including failure to provide reasonable maintenance) or if there have been accidents to the equipment or if it has been repaired or altered by someone else. THIS IS A LIMITED EXPRESS WARRANTY ONLY. TFT EXPRESSLY DISCLAIMS WITH RESPECT TO THE EQUIPMENT ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. THERE IS NO WARRANTY OF ANY NATURE MADE BY TFT BEYOND THAT STATED IN THE DOCUMENT. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 14

11.0 MAINTENANCE The EF1 RC Monitor requires little maintenance. The unit should be kept clean and free of dirt by rinsing with water after each use. Any inoperable or damaged parts should be repaired or replaced before placing the unit in service. Equipment can be returned to the factory for service and/or testing. 11.1 LUBRICATION Any alterations to the monitor and its markings could diminish safety and constitutes a misuse of this product The EF1 monitor generally should not require greasing. In the event that the operation becomes stiff grease may be applied to the horizontal rotation and elevation worm gears. See figure 3.1 for grease port locations. Use medium viscosity automotive chassis grease. Apply only enough grease to restore normal operation. If normal operation is not restored by greasing than inspect for other causes of stiff operation. Note: Do not over pump grease. The monitor s greased areas lead to large chambers that could trap several pounds of grease before becoming visible. 11.2 TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE REMEDY Leaks Debris or damage in seal area Clean out debris or replace damaged parts Elevation Binding Debris or damage to elevation drive parts Clean out debris or replace damaged parts Horizontal Rotation Binding Lack of lubricant Grease, see section 11.1 May be electrical related Debris or damage to horizontal drive parts See trouble shooting section of Electronics Manual LIY-500 Clean out debris or replace damaged parts Lack of lubricant Grease, see section 11.1 May be electrical related See trouble shooting section of Electronics Manual LIY-500 11.3 REPAIR Factory service is available with repair time seldom exceeding one day in our facility. Factory serviced appliances are repaired by experienced technicians to original specifications, fully tested, and promptly returned. Repair parts and service procedures are available for those wishing to perform their own repairs. Task Force Tips assumes no liability for damage to equipment or injury to personnel that is a result of user service. For additional information on care, maintenance, and testing, refer to: NFPA 1962: Standard for the Care, Use, Inspection, Service Testing, and Replacement of Fire Hose, Couplings, Nozzles, and Fire Hose Appliances, 2013 Edition 12.0 ANSWERS TO YOUR QUESTIONS We appreciate the opportunity of serving you and making your job easier. If you have any problems or questions, our toll-free Hydraulics Hotline, 800-348-2686, is normally available to you 24 hours a day, 7 days a week. 15

13.0 INSPECTION CHECKLIST BEFORE EACH USE, appliances must be inspected to this checklist: All valves (if so equipped) open and close fully and smoothly Waterway is clear of obstructions There is no damage to any thread or other connection All locks and hold-down devices work properly The pressure setting on the relief valve (if so equipped) is set correctly Gaskets are in good repair There is no obvious damage such as missing, broken, or loose parts There is no damage to the appliance that could impair safe operation (e.g. dents, cracks, corrosion, or other defects) All swiveling elements rotate freely Nozzle is securely attached BEFORE BEING PLACED BACK IN SERVICE, appliances must be inspected to this list: 1. All valves open and close smoothly and fully 2. The waterway is clear of obstructions 3. There is no damage to any thread or other type connection 4. The pressure setting of the relief valve, if any, is set correctly 5. All locks and hold-down devices work properly 6. Internal gaskets are in accordance with NFPA 1962 (2013) Section 7.2 7. There is no damage to the appliance that could impair safe operation (e.g. dents, cracks, corrosion, or other defects) 8. All swiveling connections rotate freely 9. There are no missing parts or components 10. The marking for maximum operating pressure is visible 11. There are no missing, broken, or worn lugs on couplings NFPA 1962: Standard for the care, use, inspection, service testing, and replacement of fire hose, couplings, nozzles and fire hose appliances. (2013 ed., Section 6.2.1). Quincy, MA: National Fire Protection Agency. Any monitor failing any part of the inspection checklist is unsafe and must have the problem corrected before use. Operating a monitor that fails any of the above inspections is a misuse of this equipment. TASK FORCE TIPS, INC. MADE IN USA www.tft.com 3701 Innovation Way, Valparaiso, IN 46383-9327 USA 800-348-2686 219-462-6161 Fax 219-464-7155