OF HYRUM DAM AUXILIARY

Similar documents
Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

USING A LABYRINTH WEIR TO INCREASE HYDRAULIC CAPACITY. Dustin Mortensen, P.E. 1 Jake Eckersley, P.E. 1

HYDRAULIC JUMP AND WEIR FLOW

EXAMPLES (OPEN-CHANNEL FLOW) AUTUMN 2018

The Hydraulic Design of an Arced Labyrinth Weir at Isabella Dam

Broadly speaking, there are four different types of structures, each with its own particular function:

DESIGN OF BELL-MOUTH SPILLWAY AT BARVI DAM

STRUCTURE S-65 PURPOSE SPILLWAY OPERATION

SUBMERGED VENTURI FLUME. Tom Gill 1 Robert Einhellig 2 ABSTRACT

Designing Labyrinth Spillways for Less than Ideal Conditions Real World Application of Laboratory Design Methods

Stability of Concrete Macro-Roughness Linings for Overflow Protection of Earth Embankment Dams ( 1 ) - Discussion

ANSWERS TO QUESTIONS IN THE NOTES AUTUMN 2018

NUMERICAL AND PHYSICAL MODELING

HY-8 Version 7.2 Build Date January 17, Federal Highway Administration.

Evaluation of step s slope on energy dissipation in stepped spillway

COST EFFECTIVE STORAGE CAPACITY INCREASE FOR ALUMINA TAILINGS DISPOSAL AREA THROUGH SPILLWAY OPTIMISATION

Exercise (3): Open Channel Flow Rapidly Varied Flow

Experimental Investigation on Changes of Water Surface Profile with Gaussian Shaped Bottom and Side Roughness

Scott Dam Spillway Comparing Physical Model Study Results

APPENDIX A STRUCTURE DESCRIPTIONS AND RATING CURVES

APPENDIX C VEGETATED EMERGENCY SPILLWAY. VERSION 1.0 March 1, 2011

Transition Submergence and Hysteresis Effects in Three-Foot Cutthroat Flumes

AIR-WATER FLOW STRUCTURES AT AN ABRUPT DROP WITH SUPERCRITICAL FLOW

Technical Report Culvert A Hydraulic Analysis

Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati


Impact of anti-vortex blade position on discharge experimental study on the coefficient of morning glory spillway

Greenup Lock Filling and Emptying System Study

DAIVÕES DAM SPILLWAY: A NOVEL SOLUTION FOR THE STILLING BASIN

OPEN CHANNEL FLOW WORKSHEET 3 WATER SURFACE PROFILES

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Simple Flow Measurement Devices for Open Channels

Exercise (4): Open Channel Flow - Gradually Varied Flow

MODEL STUDY OF PRADO FLOOD-CONTROL DAM

PKWeir and flap gate spillway for the Gage II Dam

APPENDIX J HYDROLOGY AND WATER QUALITY

Plan B Dam Breach Assessment

ACCEPTED VERSION.

AppendkA. Prototype Labyrinth Spillways

STRUCTURAL STABILITY ASSESSMENT

Folsom Dam Joint Federal Project Existing Spillway Modeling

Effect of channel slope on flow characteristics of undular hydraulic jumps

Session C9: Priest Rapids Fish Bypass: A Case Study from Start to Finish

Investigation of Cavitation Damage Levels on Spillways

Hydraulic Evaluation of the Flow over Polyhedral Morning Glory Spillways

2O-2 Open Channel Flow

LEHIGH UN IVERS ITY CIVIL ENGINEERING DEPARTMENT. Project Report No. 54. Prepared by. John R. Adam~;.,:~."; Arthur W. Brune and Stephen C.

IMPACT OF MAKING THE CREST OF WEIR MULTIFACETED ON DISCHARGE COEFFICIENT OF MORNING GLORY SPILLWAY

MEMORANDUM. TNC Fisher Slough Final Design and Permitting Subject: DRAFT Technical Memorandum: Levee Emergency Spillway Design

Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati

3. GRADUALLY-VARIED FLOW (GVF) AUTUMN 2018

V393.R46. NalupwL UNITED STATES EXPERIMENTAL MODEL BASIN NAVY YARD, WASHINGTON, D.C. BILGE KEEL CAVITATION J. G. THEWS SEPTEMBER REPORT NO.

Design of Spillway Upgrades

Hours / 100 Marks Seat No.

Figure 3B-1. Examples of Two-Lane, Two-Way Marking Applications

Discharge Coefficient in Siphon Spillway with Different Cross Sections

TDLP INC. The Dam & Levee Professionals. Kevin Chancey Sarah Edens. Monica Murie Jason Unruh

3D NUMERICAL MODELLING OF THE CAPACITY FOR A PARTIALLY PRESSURIZED SPILLWAY

FORMAT FOR SENDING COMMENTS. Title: CRITERIA FOR DESIGN OF CANAL HEAD REGULATORS (Second revision of IS 6531)

CLAIBORNE LOCK AND DAM PERTINENT DATA

APPENDIX B HYDRAULIC DESIGN DATA FOR CULVERTS

Chapter 11. Culverts and Bridges Design Checklist for Culvert Design

STRUCTURE 65-B PURPOSE SPILLWAY OPERATION

PROFILE OF SACRAMENTO RIVER, FREEPORT TO VERONA, CALIFORNIA,

Spillway Design for Small Dams

1. In most economical rectangular section of a channel, depth is kept equal to

St. Mary Diversion Dam Case Study of a 100 year Old Diversion

Hydraulic Modeling to Aid TDG Abatement at Boundary and Cabinet Gorge Dams

Wave Prediction in the Santa Barbara Channel

19.1 Problem: Maximum Discharge

PENNDRAIN.rep. HEC-RAS Version May 2005 U.S. Army Corp of Engineers Hydrologic Engineering Center 609 Second Street Davis, California

Measuring Water with Parshall Flumes

Large-scale Field Test

Request Number IR1-12: Flow Passage. Information Request

Modeling the Mangla Dam Spillway for Cavitation and Aerators Optimization *

Evaluating the Spillway Capacity of the Morning Glory Spillway at Harriman Dam

InvestigatingThe Effect of Number of Steps on Energy Dissipation of Stepped Spillways Based on the New Design Approach.

Modelling of Pressurised Pipes within InfoWorks ICM and CS

Follow this and additional works at:

Transitional Steps Zone in Steeply Sloping Stepped Spillways

2. RAPIDLY-VARIED FLOW (RVF) AUTUMN 2018

Components of a Barrage

LABORATORY EXPERIMENTS ON WAVE OVERTOPPING OVER SMOOTH AND STEPPED GENTLE SLOPE SEAWALLS

International Journal of Scientific & Engineering Research, Volume 5, Issue 1, January ISSN

CHAPTER 4 SPALDING COUNTY, GEORGIA 4.0 CULVERT DESIGN

Sediment Basin 7E-12. Design Manual Chapter 7 - Erosion and Sediment Control 7E - Design Information for ESC Measures BENEFITS.

Outlet Structures T-12

Evaluating Surge Potential in CSO Tunnels

A Comparative Study of Self-aerated Stepped Spillway and Smooth Invert Chute Flow: The effect of Step-induced Macro-roughness

Annex E Bridge Pier Protection Plan

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

COEFFICIENT OF DISCHARGE OF CHIMNEY WEIR UNDER FREE AND SUBMERGED FLOW CONDITIONS

SPILLWAY REPLACEMENT PROJECT NUMERICAL AND PHYSICAL MODELING. Kara Hurtig, Water Resources Engineer, Northwest Hydraulic Consultants, BC, Canada

Investigation of Suction Process of Scroll Compressors

Bridge Design Preliminary Bridge Design Example 1 / 6 Spring 2012 updated 1/27/2012

Packwood Hydroelectric Project Barrier Analysis December 12, 2006

Driveway Design Criteria

SUPERCRITICAL FLOW AT AN ABRUPT DROP : FLOW PATTERNS AND AERATION

Options for Reducing Total Dissolved Gas at the Long Lake Hydroelectric Facility. Northwest Hydraulic Consultants Inc, Seattle, Washington, USA

Ellis Y. Byeon, PE Bryan VanderGheynst, PE 1

Transcription:

HYDRAULIC MODEL STUDY OF HYRUM DAM AUXILIARY LABYRINTH SPILLWAY May 7983 Engineering and Research Center S. Department of the Interior Bureau of Reclamation Division of Research Hydraulics Branch

7-2090 (4-81) Bureau of Reclamation TFCUhllCAl RFPnRT STANnARn TITI F PACF Hydraulic Model Study of Hyrum Dam Auxiliary Labyrinth Spillway 7. AUTHOR(S) 8. PERFORMING ORGANIZATION REPORT NO. Kathleen L. Houston GR-82-13 9. PERFORMING ORGANIZATION NAME AND ADDRESS 10. WORK UNIT NO. Bureau of Reclamation Engineering and Research Center Denver, Colorado 80225 2. SPONSORING AGENCY NAME AND ADDRESS 11. CONTRACT OR GRANT NO. 13. TYPE OF REPORT AND PERIOD COVERED Same 15. SUPPLEMENTARY NOTES 14. SPONSORING AGENCY CODE 1 Microfiche and/or hard copy available at the Engineering and Research Center, Denver, Colorado. Editor-REC 16. ABSTRACT The updated IDF (inflow design flood) for Hyrum Reservoir could not be passed with the existing hydraulic structures. The labyrinth was the most economical alternative for an auxiliary spillway. The labyrinth spillway, a series of trapezoidal shapes in plan form, would provide the necessary spillway length and capacity within a comparatively small width. The spillway configuration was based on design curves developed in the Bureau of Reclamation Hydraulic Laboratory. The 1:30 scale model included the upstream approach channel, the labyrinth spillway, and a transition section leading to a long sloping chute. The model confirmed the maximum discharge of the spillway and investigated different approach conditions and spillway orientations. Water surface profiles were measured over the spillway and in the chute downstream of the spillway. Splitter piers were installed to provide aeration under low flow conditions. 17. KEY WORDS AND DOCUMENT ANALYSIS 0. DESCRIPTORS-- / model study/ hydraulics/ labyrinth spillway/ approach conditions/ water surface profiles/ splitter piers b. IDENTIFIERS-- / Hyrum Dam/ Hyrum Project, Utah 18. DISTRIBUTION STATEMENT 19. U 20. SECURITY CLASS 21. NO. OF PAGE (THIS REPORT) on NCLASSIFIED I LY SECURITY CLASS 22. PRICE (THIS PAGE)

GR-82-13 HYDRAULIC MODEL STUDY OF HYRUM DAM AUXILIARY LABYRINTH SPILLWAY Kathleen by L. Houston Hydraulics Branch Division of Research Engineering and Research Center Denver, Colorado May 1983 UNITED STATES DEPARTMENT OF THE INTERIOR * BUREAU OF RECLAMATION

ACKNOWLEDGMENTS Bruce Moyes and Fred Lux of the Concrete Dams, Spillways and Outlets Section, Dams Branch, Division of Design, initiated the study. Their suggestions throughout the course of the study were appreciated. Supervision and assistance were provided by Thomas J. Rhone, Head of the Hydraulic Structures Section, throughout the study. Cheryl A. States assisted with data gathering and Barbara Prokop with editing. Photographs were taken by Wayne K. Lambert. As the Nation's principal conservation agency, the Department of the Interior has responsibility for most of our nationally owned public lands and natural resources. This includes fostering the wisest use of our land and water resources, protecting our fish and wildlife, preserving the environmental and cultural values of our national parks and historical places, and providing for the enjoyment of life through outdoor recreation. The Department assesses our energy and mineral resources and works to assure that their development is in the best interests of all our people. The Department also has a major responsibility for American Indian reservation communities and for people who live in Island Territories under U.S. Administration. The information contained in this report regarding commercial products or firms may not be used for advertising or promotional purposes and is not to be construed as an endorsement of any product or firm by the Bureau of Reclamation. ii

. Frontispiece.-Hyrum Dam, with location of proposed auxiliary spillway. P801-D-80189 III

CONTENTS Introduction. Conclusions. Application The mod~l Similitude and test discharges Test plan Labyrinth spillway tests Initial labyrinth spillway design (tests 1 and 1A)... Tests 2 and 2A... Test 3... Final design, test 4 Chute water surface profiles.......................................... Splitter piers........................................................ Bibliography.......,....,...,. Page 1 1 3 3 4 4 5 5 6 7 9 10 10 12 v

Figure FIGURES 1a Plan of existing and auxiliary spillways......................... 1b Section of the auxiliary spillway............................... 2 Schematic of the spillway approach conditions and labyrinth spillway orientations tested................................... 3 Scale model (1:30) of the Hyrum auxiliary labyrinth spillway...................................................... 4 Dimensions of the labyrinth spillway used in tests 1, la, 2, 2A, and 3,. 5 View of labyrinth spillway (test 1A), Q = 8970 ft3/s, reservoir El. 4678... 6 View of labyrinth spillway (test 2), Q = 8200 ft3/s, reservoir El. 4678,. 7 View of labyrinth spillway (test 2A), Q = 9050 ft3/s, reservoir El. 4678, 8 Comparison of upstream water surface profiles (tests 2 and 2A)... 9 View of labyrinth spillway (test 3), Q = 8490 ft3/s, reservoir El. 4678 """""""""""""""""""""'" 10 Dimensions of the recommended labyrinth spillway (test 4),. 11 Discharge curve for the recommended labyrinth spillway design (test 4)... 12 View of the recommended labyrinth spillway (test 4), Q = 9050 ft3/s, reservoir El. 4677.5... 13 Upstream water surface profiles for recommended labyrinth spillway (test 4)... 14 Cross waves in spillway chute, facing downstream (test 4), Q = 9050 ft3/s. reservoir El. 4677.5 """""""""""""'" 15 View of labyrinth spillway (test 4), nonaerated low flow, Q = 2000 ft3/s, reservoir El. 4673.5... 16 View of labyrinth spillway (test 4) with splitter pier, Q = 2000 ft3/s, reservoir El. 4673.5 """""""""""""'" Page 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 VI

INTRODUCTION Hyrum Dam, located on the Little Bear River 10 miles south of Logan, Utah, was completed in 1935. The earthfill dam is 540 ft long with a 50-ft-wide gated spillway and a concrete-lined tunnel outlet works. The capacity of the spillway is 5600 ft3/s and the outlet works capacity is 300 ft3/s, at the normal reservoir El. (elevation) of 4672.0 ft. The primary purpose of the reservoir is to provide irrigation water. The IDF (inflow design flood) for Hyrum Dam was revised in 1981. The existing hydraulic structures could not pass this revised flood. The preferred alternative to pass the increased IDF was to construct an ungated auxiliary labyrinth spillway. The spillway will be located approximately 500 ft from the right abutment of the dam, nearly parallel to the existing spillway (fig. 1). The 300-ft-long labyrinth spillway will be built in two cycles within a 60-ft width. A 40-ft-wide, 683-ft-Iong concrete chute and a 143-ft-Iong stilling basin will be downstream. The spillway will be 12 ft high with a crest El. of 4672.0 ft. When discharges are required, the existing spillway will be operated initially, with a flow over the labyrinth spillway occurring when the normal water surface of 4672.0 ft is surpassed. The capacity of the labyrinth spillway is 9830 ft3/s at maximum reservoir El. 4678.0. The hydraulic model study was performed to ensure passage of the maximum discharge at maximum reservoir El. 4678.0, and to study the spillway approach conditions, water surface profiles, and flow patterns in the chute. The laboratory work associated with this study was begun in December 1981 and completed in March 1982. CONCLUSIONS 1. The flume tests for length magnification of five showed that the labyrinth weir orientation of two apexes downstream was slightly more efficient hydraulically than that of two apexes upstream. However, tests done with the Hyrum spillway model showed that a good entrance condition had more effect on spillway efficiency than spillway orientation. 1

2. The square-cornered labyrinth spillway entrance used in tests 1, la, 2, and 3 produced unacceptable flow conditions. This entrance reduced the efficiency of the spillway's upstream apexes and side lengths near the entrance corners. 3. The recommended labyrinth spillway entrance, placement, and orientation are shown on figures 1 and 2. The curved entrance is formed by a 21-ft radius between Stas. (survey stations) 1+44 and 1+65. At Sta. 1+65, the walls begin a 1:0.12 convergence that continues through the transition section to the 40-ft wide spillway chute at Sta. 2+80. The spillway will be placed with the two upstream apexes extending into the reservoir to Sta. 1+25. This spillway configuration passed the maximum discharge, 9050 ft3/s at reservoir E1. 4677.5 (H =5.5 ft), which is 0.5 ft below the maximum reservoir E1. 4678.0. 4. For the recommended spillway design, cross waves and turbulence in the chute caused overtopping of both sidewalls during operation at maximum discharge. Most sidewall overtopping occurred between Stas. 2+73 and 2+87, the end of the chute transition section. The wall height should be raised 1.5 ft between these stations. Overtopping also occurred between Stas. 3+34 and 3+55 and between Stas. 4+47 and 4+82. The wall height should also be raised in these areas, or erosion protection should be placed along both sides of the chute. The alternatives to raising the wall heights in these areas are to: (a) lengthen the transition section, or (b) widen the downstream chute which will lessen the contraction. Neither would be cost effective. Turbulent flow immediately downstream of the spillway would cause considerable spray in the prototype. 5. Splitter piers on the spillway crest will provide aeration and prevent nappe oscillation during low discharge operation. These piers should be located 6.0 ft upstream of the downstream apexes on each spillway side length. A pier height of 1.5 ft will provide adequate aeration for discharges up to at least 1765 ft3/s. 2

APPLICATION Although the model study was site specific, the concept of the labyrinth spillway has many applications. Labyrinth spillways are economical because a long spillway crest may be compressed into a narrow width which allows reduction of the head required to pass a large discharge. The spillway height provides reservoir storage as an alternative to a gated structure. The Hyrum spillway utilizes all of these features. The required 300-ft spillway crest length is contained in a 60-ft width with the spillway height providing storage up to the present normal water surface and free overflow of the updated IDF as the reservoir level exceeds 4672.0 ft. THE MODEL The 1:30 scale model included the auxiliary two-cycle labyrinth spillway, about 240 ft of reservoir topography on either side of the spillway, the transition section, and the spillway chute. The model included only the prototype features that would affect the spillway performance to allow the labyrinth spillway to be modeled as large as possible in the available laboratory space. The reservoir topography was modeled using concrete, with areas where changes might be required modeled in plywood, metal, or pea gravel. The spillway chute and walls were modeled in plywood. All the labyrinth spillways were modeled with mahogany. Water was supplied to the model by the permanent laboratory system and measured with venturi meters. The prototype labyrinth spillway will be 12 ft high with a vertical upstream face and a 1:16 batter on the downstream face. The crest will be 1.0 ft wide at thetop with 0.5-ft radius forming a rounded upstream edge. The dimensions of the two-cycle spillway varied with the several designs tested; however, the total length remained constant. Two transition shapes were tested, both leading to a 40-ft-wide chute with a 0.04 slope. The chute terminates in a stilling basin, which was not modeled. An overall view of the model is shown on figure 3 with the recommended labyrinth spillway, reservoir approach, and transition section installed. 3

SIMILITUDE AND TEST DISCHARGES The hydraulic model was designed with identical Froude numbers between the model and prototype reflecting similitude of gravitational effects. The model scale ratio of 1:30 resulted in the following parameters: Parameter Vertical and horizontal lengths Velocity Area Volume Discharge Ratio Lr = 1:30 Vr =L/12 =(1:30)112 =1:5.477 Ar =Lr2 =(1:30)2 =1:900 Vr =Lr3 = (1:30)3 =1:27000. Qr =V rar =L/12Lr2 =(Lr)5/2 =1:4929.5 For example, a prototype discharge of 9050 ft3/s equals a model discharge of: 9050 ft3/s =1.836 ft3/s 305/2 For documentation purposes, representative discharges of 2000, 4000, 6000, and 9050 ft3/s were tested for each model change. TEST PLAN The primary purpose of the model study was to verify the ability of the spillway to pass the maximum discharge, 9050 ft3/s, within the maximum head of 6.0 ft which occurs at reservoir El. 4678.0. Discharge capacity data were taken for each orientation and dimension change of the labyrinth spillway and each spillway entrance configuration. Each change had a significant effect on the flow distribution and the spillway efficiency. Water surface profiles and photographs were taken upstream of the spillway and in the transition and chute downstream of the spillway to document the flow distribution caused by the spillway orientation and entrance changes. The design of the two-cycle labyrinth spillway was based on the procedure developed by Hay and Taylor [1]* and modified design curves developed in the USBR * Numbers in brackets indicate entries in Bibliography. 4

Hydraulic Laboratory [2]. Flume tests to determine the effect of the labyrinth spillway orientation (one or two apexes downstream) were completed prior to installing a labyrinth spillway in the Hyrum model. These tests showed that the spillway orientation with two apexes downstream was slightly more hydraulically efficient. The Hyrum model provided the opportunity to study the effect of approach conditions on the spillway orientation. The flume test results were compared to the results obtained in the Hyrum spillway model. A schematic of each approach condition and spillway orientation is shown on figure 2, referred to as tests 1, la, 2, 2A, 3, and 4. The recommended design is the one used in test 4. LABYRINTH SPILL WAY TESTS Initial Labyrinth Spillway Design (Tests I and IA) The initial design, test 1, is shown on figures 2 and 4. Tests 1 and la were done with the same labyrinth orientation and dimensions. The difference between the two tests was the placement of the 2: 1 sloped area adjacent to the square-edged entrance. In test 1 the slope started 18 ft back from the corners of the entrance and in test la the slope began at the entrance corner. The toe of the slope was at El. 4660.0 in both tests. The upstream apexes of the spillways were located 5.0 ft downstream from the square-edged entrance at 5ta. 1+49. The approach configuration in test la provided a slightly better flow distribution which produced a slightly higher spillway discharge capacity. The difference in discharge was only 4.0 percent; however, neither test configuration passed the maximum design discharge of 9050 ft3/s. At reservoir El. 4678.0 (H =6.0 ft), the maximum discharges for tests 1 and la were 8625 and 8970 ft3/s, respectively. Test la was close to passing the maximum discharge; however, the square-edged entrance caused contractions at the sidewalls and turbulent flow distribution in the upstream channels (fig. 5). 5

The contraction of the flow had two adverse effects: the flow was directed away from the wall toward the center of the spillway channel, and the water surface in the upstream spillway channels showed unusual flow distribution. The effective length of spillway crest was reduced by about 22 ft, as little flow occurred over each apex and spillway length near the channe1 sidewalls. The water surface profile showed two drops: one at the entrance to the spillway channel, and another in both upstream channels of the labyrinth. These drops were due to an increase in velocity as the flow accelerated. The first drop in water surface was due to the area contraction as suhcritical flow from the reservoir entered the narrower width of the spillway opening. Normally, this initial drop in water surface would be followed by a slight increase and then a gradual decrease in water surface as the water flowed over the sidewalls of the spillway. However, the square-cornered entrance caused another noticeable drop in water surface (fig. 5) which did not occur with the other entrance configurations of tests 2A and 4. Tests 2 and 2A Tests 2 and 2A were performed with the labyrinth spillway of the previous tests, but with the orientation reversed. As shown on figure 2, this orientation had two apexes upstream whereas the previous tests had two apexes downstream. Also, the spillway apexes were moved upstream to 5ta. 1+44. Test 2 had the same square-cornered entrance and upstream sloping embankment section as test la. In test 2A, a curved entrance replaced the square-cornered entrance with the 2:1 sloping embankment section following the curvature (fig. 2). As predicted by the flume tests, the reversed orientation of the spillway resulted in a lower discharge capacity. At the maximum reservoir El. 4678.0 (H = 6.0 ft), the maximum discharge for test 2 was 8200 ft3/s. This discharge was8.6 percent less than test la and 9.4 percent less than the required maximum discharge. The maximum discharge was not attained until reservoir El. 4678.8 (H =6.8 ft). Figure 6 shows the spillway operating with a discharge of 8200 ft3/s at reservoir El. 4678.0 (H =6.0 ft). This figure shows the adverse effect of the spillway channel sidewalls on the side 6

lengths of each cycle and the contraction due to the square-cornered spillway entrance. The upstream water surface profile was similar to that of test la. Test 2A had the same labyrinth position as test 2, except the entrance was curved with a radius of about 27 ft starting at Sta. 1+71. The curved entrance produced a significant increase in the spillway discharge capacity. The required maximum discharge of 9050 ft3/s was attained at reservoir El. 4678.0 (H =6.0 ft). The water surface upstream of the spillway also showed an improvement in the flow distribution compared to the previous square-cornered entrances (fig. 7). A comparison of the water surface profiles for tests 2 and 2A is shown on figure 8. Test 3 Tests 3 and 4 were done with a new labyrinth spillway design. The total length was the same, but the spillway had a smaller sidewall angle and wider upstream apexes. The wider upstream apexes were necessary for field construction purposes. The dimensions of the spillway are shown on figure 4. The spillway layout is shown on figure 2. Other than the dimensional change and the placement of the spillway at ~i Sta. 1+44, tests 3 and la were similar. The maximum discharge for test 3 was 8490 ft3/s at a reservoir El. 4678.0. This was 6.19 percent less than the required spillway capacity. The failure of the spillway to pass the maximum d iseharge was a function of the square-cornered entrance, the placement of the spillway, and the wider upstream apexes. Figure 9 shows spillway operation at a flow rate of 8490 ft3/s and reservoir El. 4678.0 (H = 6.0 ft). Although the same spillway orientation was used for this test and test la (fig. 2), the discharge was 480 ft3/s less than test la. This difference was attributed to the placement of the spillway at Sta. 1+44 and the wider upstream apexes. The placement of the spillway in line with the square-cornered entrance reduced the efficiency of the upstream apexes and side lengths near the walls. This efficiency reduction was caused by the contraction of the flow from the square entrance. The 7

wider upstream apexes also reduced the efficiency of the spillway. Previous studies had shown that a triangular shape in plan is the most efficient [1]. Comparison of tests 2 and 3 showed that the spillway orientation (two apexes downstream) in test 3 provided a higher discharge capacity than test 2. The spillways were located at the same station (1 +44), but the better spillway orientation in test 3 allowed passage of a discharge that was 290 13/S greater than test 2. The wider upstream apexes did not have as much effect on the spillway discharge capacity as the spillway orientation. Comparison of tests 2A and 3 showed that spillway orientation had less effect on the discharge capacity than a good entrance condition. Test 2A (with the less efficient spillway orientation but good entrance condition) passed the maximum discharge, whereas test 3 was 560 ft3/s less than the discharge required at reservoir El. 4678.0. The following is a summary of the test comparisons: Discharge (ft3/s) at Test reservoir El. 4678.0 1 8625 Discharge,comparison la 8970 la > 1 2 8200 2 < la 2A 9050 2A > la 3 8490 3 < la 3>2 3 <2A Remarks Sloping embankment began 18 1 back from spillway squarecornered entrance. For test la, sloping embankment began at base of spillway sidewall. Test 2 spillway orientation less efficient than test la. Curved entrance had greater effect than spillway orientation. Wider upstream apexes and spillway placement reduced efficiency. More efficient spillway orientation had a greater effect than wider upstream apexes. Spillway entrance more important than spillway orientation. 8

Final Desi~n, Test 4 The final labyrinth spillway design attempted to maximize the hydraulic efficiency and decrease the field construction costs. The comparisons of the tests discussed in the previous section showed that spillway efficiency was a function of entrance conditions, spillway placement, and orientation. Comparison of tests 2 and 2A showed the importance of the entrance condition under the same spillway operation. Comparison of tests 2A and 3 showed that the entrance condition was even more vital than spillway orientation. The spillway dimensions for the final design are shown on figure 10. The placement differed from any of the previous tests. The two upstream apexes extended 19 ft into the reservoir to Sta. 1+25. The downstream apex of the spillway was located at Sta.l+97. The entrance shape was formed by a 21-ft radius betweenstas.l+44 and 1+65. At Sta. 1+44 the walls began a 1:0.12 convergence that continued through the transition section to the 40-ft wide spillway chute at Sta. 2+80. The 1:0.12 sloping floor of the chute transition section started at Sta. 2+00 and continued to Sta. 2+80 where the slope changed to 0:0.04 for the remaining chute. Lessening the slope of the transition section would decrease the construction costs. Details of this design are shown on figures la and Ib in plan and section. The schematic is shown on figure 2 for direct comparison with the other configurations tested. The final design provided the best entrance condition and spillway placement. The wide curved entrance with the spillway extending farther into the reservoir provided excellent flow distribution and minimal head loss. The maximum discharge, 9050 ft3/s, was reached at reservoir El. 4677.5 (H =5.5 ft), 0.5 ft below the maximum allowable water surface. At the maximum water surface, El. 4678.0, the discharge was 9830 ft3/s, 8.6 percent greater than required. The discharge rating curve is shown on figure 11. The coefficient of discharge at reservoir El. 4678.0 was 2.2596. Figure 12 shows the spillway operating at reservoir El. 4677.5 (H =5.5 ft) with a discharge of 9050 ft3/s. This figure shows the even flow distribution produced by the placement of the spillway and the curved entrance. 9

It was necessary to use the less efficient spillway orientation (two apexes upstream) to attach the spillway to the sidewalls when it was moved upstream into the reservoir. Upstream water surface profiles for discharges of 6000 and 9050 ft3/s showed the change in water surface as flow approached the spillway and the relatively constant water surface in the labyrinth (fig. 13). The curved spillway entrance and extension of the spillway into the reservoir provided optimum hydraulic conditions and the most efficient overall design. CHUTE WATER SURFACE PROFILES The flow in the chute downstream of the spillway was supercritical. Waves that formed downstream of the spillway traveled the length of the chute forming a crossing pattern as they reflected off the chute walls (fig. 14). The height of the waves tended to diminish as they traveled downstream. The flow over the labyrinth spillway and its placement immediately upstream of the transition produced an unusual flow distribution downstream. Flow downstream of the spillway was extremely rough due to the spillway shape, with the depth of flow at the beginning of the transition near critical. The waves originated at the entrance of the transition section where the channel width began decreasing from 60 to 40 ft. To minimize the downstream disturbance, these cross waves should be directed toward the opposite walls at the end points of the contraction [3]. To do this, the length of the transition section would have to be considerably longer or the downstream chute wider. Neither of these alternatives would be cost effective. The cross waves caused overtopping of the chute walls at the maximum discharge for each test configuration. For the recommended spillway configuration, the worst overtopping occurred at the end of the chute transition section where the wall height should be raised by about 1.5 ft from Sta. 2+73 to Sta. 2+87 on both sides. SPLITTER PIERS Spillway operation under low flow conditions could cause a problem with nappe oscillation. This phenomenon is shown on figure 15 where the nonaerated nappe 10

clings to the downstream face of the spillway. At median flows, the nappe intermittently became aerated at the apex and sprang free. The nappe then reattached as the air was exhausted. Installation of splitter piers on the spillway crest will provide aeration to prevent this. Because the nappe becomes submerged at higher discharges, the piers need only be designed for low flows. From the discharge rating curve (fig. 11), a pier height of 1.5 ft would be adequate to provide aeration for flow rates up to 1765 ft3/s. Overtopping of the piers at higher discharges did not cause any problems. The piers tested were 2.5 ft wide and were placed in several locations near the downstream apexes. The recommended pier location (the centerline of the pier) was 6.0 ft upstream of the downstream apexes on each side length. The pier shape tested was a thin metal plate; however, this shape could be different. Nonaerated and aerated flows may be seen on figures 15 and 16, respectively. The four splitter piers decreased the crest length by about 10 ft or about 3.3 percent. Prior to installing the piers, the discharge at maximum reservoir elevation was 8.6 percent greater than required. Therefore, this decrease in length still allows passage of the maximum discharge, 9050 ft3/s, at or below reservoir El. 4678.0. 11

BIBLIOGRAPHY [1] Hay, N., and G. Taylor, "Performance and Design of Labyrinth Weirs," Journal of the Hydraulics Division, ASCE, pp. 2337-2357, November 1970. [2] Houston, K.L., ""Hydraulic Model Study of Ute Dam Labyrinth Spillway," GR-82-7, Bureau of Reclamation, 41 pp., August 1982. [3] Chow, V.T., Open Channel Hydraulics, McGraw-Hili, N.Y., pp. 468-470, 1959. 12

\ EL. 4689.00 0 ~ \D <t> \ \ \ \ \~ \ ~ \ \. Q\ Q \ \ \ \ \ \ \ 0 ~ (D v I I I <t. Bridge STA. 1+88 j I Two-cycle labyrinth weir 0 q) 000 CD t-. CD 10 0 ~ CDCDCDv ~~~ (D ~ 0 q) 10 ~ ~... "'" EL. 4660.00,/ ( / Gi! // I II I (' I Ii I!! / Ii j: Ii I II 0 ; i ~ ~ 0\. ~. :: ~ \.j.,. ~ spi Ilway PLAN Figure la.-plan of existing and auxiliary spillways.

I-'... Spillway crest EL.4672.00 Normal W.S. EL. 4672.00 Max W.S. EL. 4678.00 EL.4660.00- ~ -=-- STA.I~ 5 T A. I+ 25 I 't.. Bridge STA. 1 + 88 EL.4689.00 Two-cycle labyrinth weir -s=o.i-et:4656:0o- ~.O4---- ~ -" - j;-sta. 2 + 90 STA. 2 + 23.33 Original ground surface + 1'-0 <to '0 1-1<) Cf)1<).<.0 Uq- ::>. J alw... 10 :;:0 mo t!= + 0) ~Cf) I() 10 <.0 + C\J <t I- EL.4573.00\ Cf) 20-0 EL.4583.00 ' 6:1 r/s=o.oo6 il EL.4548.od Cf)<.o.q- U..::>...J lliw N 10' I'- -. 0) + + <t I-Cf) <t I- Cf) PROFILE ALONG Ci. AUXILIARY SPILLWAY Figure lb.-section of the auxiliary spillway.

2:1 t ~ 1-60-0 R=16-4 - STA 1+ 44 -STA I t-49 TEST 1 TEST IA -STA 2+ 19 -STA 2 + 23.33 ~- STA 2+19 STA 2t-23.33? '" 2:1 2: I '" 0 STA 1+44 STA 1+44 TEST 2 TEST 2A -STA 1+71 -STA 2+ 14 STA 2 + 23.33 -STA 2 + 14 --STA 2+23.33 2:1 ~ '" STA 1 +25 STA 1+44 R;:21-0 TEST 3 FINAL DESIGN TEST 4 STA 1+64.86 -- STA 2+ 14 - STA 2+23.33 STA 1+96.75 STA 2+00? ;;; Figure 2.-Schematic? '" of the spillway approach conditions and labyrinth spillway orientations tested. (Flow direction from top to bottom). 15

Figure 3.-Scale model (1:30) of the Hyrum auxiliary labyrinth spillway. P801-D-80190 16

2'-0" I ~ i- _/'/ ~-O" ~~I,~ 12'-0".,~ JI I" RAOI Us ~0 ~I ya ~/ 0 16 ~-../ SECTION A-A ~.. --f ~:O" ~O~ --I 2'-0" Figor,. (Th, d-. "-Di""O'ioo, PLAN, f. ''''eo"oo. for 'h I h }'>'Ot. 'he h 'Pdl...,. opotre.", Ooedio 'Pex", io 'e... I, la, 2, '"" 3 "ere 3.. ft) 2A, 'od 3. 17

Figure 5.- View of labyrinth spillway (test la), Q = 8970 ft3/s, reservoir elevation El. 4678. P801-D-80191 18

Figure 6.- View of labyrinth spillway (test 2), Q = 8200 ft3/s, reservoir El. 4678. P801-D-80192 19

Figure 7.- View of labyrinth spillway (test 2A), Q = 9050 ft3/s, reservoir El. 4678. P801-D-80193 20

4680 ~v v ~~~.. ".. t-.:) - + ::!:. 4675 z 0 ;: 4670 <{ > W --.J W 0::: 0 4665 > 0::: W C/) W 0::: ~~. TEST 2 X T EST 2A EI.467,1.92 -. 0 17' '0 1> P. I--- - '0 0 4660 I 4650 +60 0+80 1+00 1+20 1+-40 1+60 1+80 2+00 2+ 0 20 1+44 2+14 S TAT ION (f t. ) Figure B.-Comparison of upstream water surface profiles (tests 2 and 2A).

Figure 9.- View of labyrinth spillway (test 3), Q = 8490 ft3/s, reservoir El. 4678. P801-D-80194 22

-----, /I r- ~I--- I ~ I ~ 30'~01l ~ ~ I ~ /'-0" ~ I 'r- 6" RADIUS "0 I C " Ar-- y --,A... --,j - 0 ' C\J 16 SECTION ~/-0" A-A 30'~0" F;g"re 1O.-DImen'Ion, of the PLAN reeommended lahyrinth 'pm..a, (t", <). 23

4680 «>w.-j w a:: - 0 > a:: w CJ) w a:: 4676 4674 /' V /,../ ~/ -:7 / t".-/v / 4672 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 - / ~'4- -... z 4678 0Ī-,.- 01 SCHARGE (ft3/s) Figure n.-discharge curve for the recommended labyrinth spillway design (test 4). 24

Figure 12.- View of the recommended labyrinth spillway (test 4), Q = 9050 ft3/s, reservoir El. 4677.5. P801-D-80195 25

4680 Nj 0\ :;:-.!:: z 0... <( > W...J W 4675 4670 a:: 0 4665 > a:: I.J:J Cf) W a:: 4660 --- ~-.. - -- - - - - Q=9050 ft3/s --- -- -. -- r r "- ~~-n ",..,... ~" Q- 6000 ft3/s EL. 4671.92- j ~" 4.0 0 (?.~ 4650 0 + 60 0+80 1+00 1+ 20 1+40 1+60 1+80 2+00 2+ I 1+25 1+96.75 20 STATION (ft.) Figure l3.-upstream water surface profiles for recommended labyrinth spillway (test 4).

Figure l4.-cross waves in spillway chute, facing downstream, (test 4), Q = 9050 ft3/s, reservoir El. 4677.5. P801-D-80196 27

Figure 15.- View of labyrinth spillway (test 4), nonaerated low flow, Q = 2000 ft3/s, reservoir El. 4673.5. P801.D.80197 28

Figure 16.- View of labyrinth spillway (test 4) with splitter pier, Q = 2000 ft3/s, reservoir El. 4673.5. PSOl.D.80198 29

Mission of the Bureau of Reclamation The Bureau of Reclamation of the U.S. Department of the Interior is responsible for the development and conservation of the Nation's water resources in the Western United States. The Bureau's original purpose "to provide for the reclamation of arid and semiarid lands in rhe West" today covers a wide range of interrelated functions. These include providing municipal and industrial water supplies; hydroelectric power generation; irrigation water for agriculture; water quality improvement; flood control; river navigation; river regulation and control; fish and wildlife enhancement; outdoor recreation; and research on water-rela ted design, construc tion, materials, atmospheric management, and wind and solar power. Bureau programs most frequently are the result of close cooperation with the U.S. Congress, other Federal agencies, States, local governmen ts, academic institu tions, water-user organizations, and other concerned groups A free pamphlet is available from the Bureau entitled "Publications for Sale." It describes some of the technical publications currently available, their cost, and how to order them. The pamphlet can be obtained upon request from the Bureau of Reclamation, Attn D-922, P 0 Box 25007, Denver Federal Center. Denver CO 80225-0007.