Owner s Manual. Mode d emploi Instrucciones de uso. Manual de instrucções

Similar documents
Booster Pump PB4-60 Replacement Kits

3/8" Dr. Air Butterfly Impact Wrench

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

OWNER S MANUAL. Page: 1 of 8

SETTING THE HANDLE HEIGHT ON THE ROLLATOR

12V AIR STATION ALL-IN-ONE

1 DRIVE INDUSTRIAL IMPACT WRENCH

Pressure Dump Valve Service Kit for Series 3000 Units

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Installation Instructions Air Compressor Part # 2780, 2781

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Pressure Dump Valve Service Kit for Series 2300 Units

[ACT 005] Manual E 5/25/05 9:24 PM Page 3 MULTI-FUNCTION

OPERATION MANUAL DMI 16-LIGHT LIGHT TOWER ALSO AVAILABLE ONLINE AT DMI-LT.COM

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

User Instruction Manual For Davit Rescue System

Everyday INFLATION STATION CORDLESS

Model VR6 System. Installation, Operation & Maintenance

INTENDED USE TECHNICAL SPECIFICATIONS

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

JACKSON GRILLS PATIO FIRE

Owner s Manual & Safety Instructions

GENUINE CARGO NET INSTALLATION AND USER S INSTRUCTIONS

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

SETUP GBW/GBWE SETUP. upper or lower position. Placing the lock in the upper position will provide 1 foot (305 mm) more height.

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

InstallatIon and owner s InstrUCtIons

DM-RARD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Rear Derailleur DURA-ACE RD-R9100 ULTEGRA RD-R8000

SERVICE & MAINTENANCE MANUAL FOR:

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)

AIR INLINE METAL SHEAR

Cocoa Patio Pond with Lit Spillway

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

TECHNICAL INFORMATION

TEM# Air Hammer Combo USER'S MANUAL

BMR 2100XL Operating Instructions Page 1 of 13

Model PSI Compressor with 3-Gallon Air Tank 12VDC

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA

Med Aire Alternating Pressure Pump and Pad System

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

USER GUIDE ROLLING WALKERS INSTRUCTIONS FOR USE JANUARY, Maximum User Weight: 170kg (Do not exceed this weight)

Pectoral Machine. User manual E S S E N T I A L S T R E N G T H

2000 lb manual winch

Right-Angle Tube Roller Model

Item N o.: Item N am e:40cm Boys Rival Bike

Sunbrite LTC Large Underwater Pool Lights

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Final Assembly Instructions Bikes with Quill Stems

44in Side Discharge Mower for Wheel Horse XL 440H Lawn Tractors Model No Serial No and Up

DBI SALA Confined Space Rescue Davit System

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

8MAY15 US RACK, Inc Falcon Drive, Madera, CA

MODEL SWH10 1,000 LB CAPACITY SWIVEL HOIST

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

444C DUAL PERFORMANCE VALUE PACK

Techcon Systems TS1258 Pressure Pot

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

IMPORTANT SAFETY INSTRUCTIONS

Standard Operating Manual

200 PSI FAST-FILL AIR SOURCE KIT

DM-RD (English) Dealer s Manual. ROAD Rear Derailleur RD-9000 RD-6800 RD-5800 RD-4700

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

TECHNICAL INFORMATION

Combination Breathing Apparatus

AIR/OVER HYDRAULIC JACK 20 TON

Important Note: Tighten lock nuts so the support tubes still swing freely see figure 2. There must be 1 2 threads of bolt past end of lock nuts.

RIV991 PNEUMATIC PUNCHING TOOL FOR HEXAGONAL HOLES OPERATING INSTRUCTIONS

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

DM-MBRD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Rear Derailleur SLX RD-M7000 DEORE RD-M6000

Flexi-pro Aerosol Delivery System (FADS) Manual

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

12" 8A Electric Snow Shovel

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

400C & 450C DUAL PERFORMANCE VALUE PACKS

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

Santa Fe Cycles Assembly Guide Introduction

Falcon 3 145, 170, 195 and Tandem Owner / Service Manual

deluxe toilet safety support

200 PSI COMPRESSORS - MODEL NUMBERS

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

Instruction Sheet. CP2000: 2000 lb Cable Puller IMPORTANT RECEIVING INSTRUCTIONS SAFETY ISSUES

Assembling & Installing your Pool Cleaner

275 RID Assembly Instructions

Operator: Save these instructions for future use!

Inflatable Acoustical Shell

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

35 TON HYDRAULIC PUNCH WARNING

200 PSI HIGH-FLOW AIR SOURCE KIT

Transcription:

Models Covered: 2K HA / 4K HA 600 HI-CR 1.2K HMI / 2.5K HMI 1K HI-BT37 NAFTA Owner s Manual Mode d emploi Instrucciones de uso Manual de instrucções 02-07-2012 / 65-63-072 B 10255 General Drive Unit A6 ORLANDO, FL 32824 USA Tel: (407)851-7870 Fax: (407)851-7831 1 www.airstar-light.us e-mail : info@airstar-light.us

Welcome To Airstar Thank you for choosing AIRSTAR. Your new Sirocco unit is hand assembled with pride in USA, and we are committed to your total customer satisfaction. Your ownership experience is extremely important to us and this user manual is designed to help keep your Sirocco performing at its highest level. Let There Be Light Your Sirocco is specifically designed to provide the highest quality light for nighttime workplace safety and productivity. It is perfect for use in a variety of worksite settings, rescue efforts, and any situation where a well-lit area is required to work. Models Covered In This Manual This manual covers the following Sirocco models: - Sirocco 2K (HA 2x1000W), Sirocco 600 (HI CR 4x150W), Sirocco 250 (HI HR 250W), Sirocco 1.2K (HMI 1200W), HMI 2.5K(HMI 2500W), Sirocco 1K (HI-BT37 1000W), Sirocco 4K HA (HA 4x1000W) EXTREMELY IMPORTANT SAFETY INSTRUCTIONS WARNING REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPOSURE TO EXCESSIVE UV RADIATION, OR INJURY: 1. LIGHTED LAMPS ARE EXTREMELY HOT. Turn off, unplug, and allow unit to cool before touching lamp. 2. ALWAYS disconnect your Sirocco unit from power source prior to servicing. 3. Do Not touch lamp cage until completely cooled. 4. Do Not look directly at lighted lamp. 5. Do Not operate Sirocco unit near flammable materials. 6. Use a soft cloth or glove when handling lamps. Oil from skin may damage lamp during operation. 7. Do not operate your Sirocco with damaged electronics or if parts are missing. 8. Do not operate your Sirocco with a damaged envelope or without an envelope. 9. All service must be performed by Airstar designated technicians. See Warranty Info for details. 10. Sirocco units are designed to operate at heights of at least 5ft (1.5m). 11. Do not operate your stand-mounted Sirocco on an uneven surface or a grade of more than 8 degrees. 12. Do not use your Sirocco if wind speed exceeds 50mph (80km/h). 13. Use only recommended stands with an ability to support a 20lb (9kg) Sirocco unit, and endure wind speeds of up to 50mph (80km/h) at a height of 16.5ft (5m). WARNING ALWAYS USE CORRECT LAMPS FOR YOUR SIROCCO TO AVOID DAMAGE OR INJURY: 1. Sirocco HA 2x1000W : use only with HA 1000W R7S type lamp or smaller 2. Sirocco HA 4x1000W : use only with HA 1000W R7S type lamp or smaller 3. Sirocco HI CR 4x150W 230V : use only with HCI-T/P 150W E27 type lamp or equivalent 4. Sirocco HI CR 4x150W 100-120V : use only with M102/O 150W MEDIUM type lamp or equivalent 5. Sirocco HMI 1200W : use only with HMI 1200W G38 type lamp 6. Sirocco HMI 2500W : use only with HMI 2500W G38 type lamp 7. Sirocco HI-BT37 1000W : use only with HI-BT37 M47 ANSI 1000W type lamp WARNING When using outdoors, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and personal injury, including the following: 1. Sirocco 2M HA / HI CR / HI HR: Use only NEMA 5-15 Edison plug extension cords connected to the correct voltage electrical source outlets. 2. Always use Ground Fault Circuit Interrupter (GFCI) protection when operating your Sirocco in areas near water, and during inclement weather. KEEP THESE INSTRUCTIONS WITH YOUR SIROCCO UNIT FOR QUICK REFERENCE 02-07-2012 / 65-63-072 B 2

Tips To Extend The Life Of Your Sirocco Unit 1.Use the included glove when handling lamps to prevent potential damage caused by transfer of oils and dirt to glass. 2.Always disconnect from power source before performing service. 3.Do not operate your Sirocco without its envelope or with a damaged envelope. 4.Protect the envelope by operating away from walls, projectiles, electric wires, trees, animals, etc. 5.DO NOT LEAVE DEFLATED ENVELOPE UNCOVERED OR UNATTENDED WHEN NOT IN USE. 6.Always use the included protective cover when storing your Sirocco. Failure to do so may result in loss of warranty coverage. 7.Store your Sirocco in a dry, well-ventilated area away from heat sources and chemical products. 8.Be sure that envelope is completely dry before installing protective cover. 9.Do not use chemical solvents to clean the envelope. Use mild soap and water as necessary. 10.Do not modify the electrical components or unit structure. 11.Do not operate your Sirocco if cable is damaged, twisted, or tangled. Recommended Generator Capacity For Sirocco Units NOTE: When using generator power, ALWAYS start your generator BEFORE plugging in your Sirocco unit. 1.Non-Ballast Sirocco Units Recommended Capacity : a) Sirocco HA 2x1000W : Single phase 120V 50-60Hz 3KVA b) Sirocco HA 2x1000W : Single phase 230V 50-60Hz 3KVA c) Sirocco HA 4x1000W : Single phase 120V 50-60Hz 5KVA d) Sirocco HA 4x1000W : Single phase 230V 50-60Hz 5KVA e) Sirocco HI CR 4x150W 100-120V : Single phase 100-120V 50-60Hz 1KVA f) Sirocco HI CR 4x150W 230V : Single phase 230V 50-60Hz 1KVA 2.Sirocco Units w/ballast Regulated Power Recommended Capacity g) Sirocco HMI 1200W 230V : 2KVA h) Sirocco HMI 2500W 230V : 5KVA i) Sirocco HI-BT37 1000W 120V : 2KVA WARNING: Be sure to avoid phase imbalance when several devices are connected to the same generator. Built-In Safety Systems Your Sirocco is equipped with special safety mechanisms that are designed to protect you and your Sirocco in the unlikely event of equipment failure or in certain unsafe operating conditions: - The Airstar Sirocco 600 (HI CR 4x150W) is equipped with a safety thermal switch that turns off the lamps if internal operating temperature rises to unsafe levels. - The Airstar HA, HMI, HI-T, HI-BT37 units are equipped with a safety pressure switch that turns off the lamps if internal envelope air pressure falls below safe operating levels. - If lamp starts blinking due to excessive heat, check and clean filter, be sure the fan is running and fresh air is circulating through the unit. Be sure the envelope is under consistent observation. 02-07-2012 / 65-63-072 B 3

Sirocco Parts List 1 5 2* 6 3* 7 3 9 10 8 4 2 11 13 12 14 Sirocco Lamp Variations a b c d e *see detail at right 1 Nut 2 Internal Structure (Cage + Base + Support Stem) 3 Envelope 4 Power Supply Cable 5 Zipper 6 Lamp(s) (See Lamp Variations Pictured Above) a HA 1000W R7S lamp b HCI-T/P 150W E27 lamp M102/O 150W MEDIUM lamp c HMI 1200W G38 lamp d HMI 2500W G38 lamp e HI-BT37 1000W E39 ANSI lamp 7 South Pole Plate 8 Stand (Recommended Accessory. Sold separately.) 9 Repair Kit (2 Pieces) 10 Protective Storage Cover 11 Storage Tube 12 User Manual 13 Ballast (Required For Select Models) 14 Cotton Glove (For Lamp Replacement) 02-07-2012 / 65-63-072 B 4

Envelope Installation Instructions When REPLACING an old envelope, FIRST remove original envelope: If currently in use, first turn unit off and let cool. Unplug the Sirocco unit and open the envelope zipper. Unscrew the nut on the top of the envelope. (Fig. 1) Set top nut in a secure place. Maneuver top of cage to unzipped opening and pass the cage through until fully exposed. Unhook the lamp holder springs (Fig. 2 only select Sirocco models) Remove lamp(s) from unit. (See Lamp Replacement Instructions for detailed information on lamp removal.) Unplug the ground wire from the cage. (Fig. 3 black arrow) Unscrew the six(6) nuts on the South Pole Plate at base of cage. (Fig. 3 white arrows) Remove zip-ties from cage crossbar and unhook red rubber tabs. (HI CR 4x150W Sirocco 600 model ONLY) Carefully remove the cage from assembly. Detach old envelope from assembly by sliding up along lamp assembly. Inspect South Pole Plate gasket (Fig. 4) for damage. Replace if damaged and ensure proper alignment. Slide South Pole opening of new envelope over electronic assembly. s Fig. 1 Fig. 2 Fig. 3 Install your NEW envelope: Unfold the envelope on a smooth, clean surface. Open the zipper Position zipper on same side of unit as ground wire. (Fig. 3) Ensure alignment of envelope holes on South Pole Plate. Slide the cage inside the envelope through the zipper opening. Align cage on South Pole baseplate with ground pin on the cage in line with ground wire on the unit. (Fig. 3) Reattach ground wire to ground pin on cage. Screw the six(6) South Pole Plate nuts onto the cage. (Fig. 3) Reinstall lamp(s). (See Lamp Replacement Instructions for detailed information on lamp removal.) Reconnect lamp holder springs (Fig. 2 only on select Sirocco models). Be sure to hook springs OVER the cage crossbars. Loosely replace the nut on the top of the envelope. Do not tighten until after envelope is fully inflated. Close zipper. Plug Sirocco unit into appropriate power source. (CAUTION: When plugging into ballast power, always plug your Sirocco unit into the ballast BEFORE plugging ballast into power source.) After envelope is fully inflated, tighten top nut. You are now ready to work. Disassembly Switch off, deflate, and store your Sirocco unit. Disconnect from power supply and let lamps cool completely. (PACKING HOT LAMPS WILL DAMAGE UNIT.) Open the envelope zipper to speed up deflation and cooling. Remove the Sirocco unit from stand or mount. Fig. 4 02-07-2012 / 65-63-072 B 5

When lamps are completely cooled, insert Sirocco unit into storage bag and store in included case. (Be sure envelope is dry before storage!) Lamp Replacement Instructions Sirocco 2K (HA 2x1000W) (Fig. 1) & Sirocco 4K HA (HA 4x1000W) (Fig. 2) Unplug the Sirocco unit and open the envelope zipper. (Be sure to let unit cool.) Using a glove, remove old lamps by grasping bulb firmly and applying downward pressure and sliding the top of the lamp out of the fixture, then lifting the lamp up and out of the fixture. Insert new lamps by inserting bottom of lamp into fixture, applying downward pressure, and then sliding top of lamp into the top of the fixture. Close the zipper. Fig. 1 Fig. 2 Sirocco 600 (HI CR 4x150W) Unplug the Sirocco unit and open the envelope zipper. (Be sure to let unit cool.) Unhook the lamp holder springs and place lamp holder aside. (Fig. 3) Fig. 3 Fig. 4 Using a glove, remove the old lamps and replace with new lamps. (Fig. 4) Replace top lamp holder and hook springs over the edge and up through lamp support plate. (Fig. 3) Close the zipper. 02-07-2012 / 65-63-072 B 6

Lamp Replacement Instructions (cont.) Sirocco 1.2K (HMI 1200W) Unplug the Sirocco unit and open the envelope zipper. (Be sure to let unit cool.) Unhook the lamp holder springs and place lamp holder aside. (Fig. 1) Fig. 1 Fig. 2 Using a glove, remove the old lamp and replace with new lamp. (Fig. 2) Replace lamp holder and hook springs over the edge and up through lamp support plate. (Fig. 1) Close the zipper. Sirocco 2.5K (HMI 2500W) Unplug the Sirocco unit and open the envelope zipper. (Be sure to let unit cool.) Using a glove, remove the old lamp and replace with new lamp. (Fig. 3) Close the zipper Fig. 3 02-07-2012 / 65-63-072 B 7

Lamp Replacement Instructions (cont.) Sirocco 1K (HI-BT37 1000W) Unplug the Sirocco unit and open the envelope zipper. (Be sure to let unit cool.) Unscrew the top-nut at the top of the envelope and set nut safely aside. (Fig. 1) Lift envelope off of the north pole pin and carefully slide unzipped envelope opening down around cage, toward south pole plate. Unscrew the nylon fasteners at the base of the lamp (inside the cage) that secure the included wrench. (Fig. 2 Arrows a. & b.) Using the wrench, loosen and remove the two nuts on the underside of the top brace and remove the top brace from the cage, allowing you to access the lamp. (Fig. 3) a. b. Fig. 1 Fig. 2 Fig. 3 Unhook the lamp holder springs and place lamp holder aside. (Fig. 4) Using a glove, remove the old lamp and replace with new lamp. (Fig. 5) Replace top lamp holder and hook springs evenly around cage as shown. (Fig. 4) Fig. 4 Fig. 5 Reinstall the plate on the top of the cage using the wrench. (Fig. 3) Reattach the included wrench using the included plastic thumb wheels. (Fig. 1) Carefully guide envelope back up around cage and guide the top pin through the top of the envelope. (Fig. 1) Loosely replace the nut on the top of the envelope. Do not tighten until envelope is fully inflated. (Fig. 1) Close the zipper. Plug-in the Sirocco unit to inflate the envelope. Hand-tighten the top nut to secure envelope to the cage. 02-07-2012 / 65-63-072 B 8

In The Event Of Broken Lamp(s) If a lamp breaks or cracks inside the envelope, disconnect the electrical power supply and disassemble the envelope. (see Envelope Installation Instructions) Be sure to remove all fragments of glass, using a vacuum cleaner to thoroughly clean the electronics and envelope. Handling glass fragments can cause serious injury. Installing Your Sirocco On A Stand NOTE: Always use Airstar-approved stands designed to work with your Sirocco unit. Always securely tighten all T-Handles to avoid injury. Stands are designed for vertical mounting of Sirocco units ONLY. ALWAYS use sandbags to weight stands properly. Airstar sandbags are recommended. Using the optional Airstar ST303 (Fig. 1) or ST101 or ST201(Fig. 2) stands. o Unfold the stand. o Lock the base in place. - On the ST303 (Fig. 1), lift the outer cylinder at the base slightly, then hook the oval locking ring over the safety hook. - On the ST101 or ST201 (Fig. 2), slide the stand legs out from the folded position until the support bars are exactly horizontal. o When using your stands in windy conditions, use the following weighting recommendations to keep your stand stable. - On the ST303 (Fig. 1), weights must be placed on each foot at 24 in (60 cm) from the center of the stand. - On the ST101 or ST201 (Fig. 2), weights must be placed on each support at 20 in (50 cm) from the center of the stand. - Use the table below to determine proper sandbag weighting. Wind speed Required Weight Per Leg Total Weight Required 0 6 mph N/A N/A 6 12 mph 40 lbs 120 lbs 12-25 mph 66 lbs 140 lbs 25-37 mph 154 lbs 465 lbs 37-50 mph 265 lbs 795 lbs Fig. 1 Fig. 2 20 in (50 cm) 24in (60 cm) Load Load Load Load Load Load 02-07-2012 / 65-63-072 B 9

When Operating Ballast Powered Sirocco Units Sirocco models that require a ballast: Sirocco 1K, Sirocco 1.2K, Sirocco 2500, and Sirocco 4K. ALWAYS PLUG SIROCCO UNIT INTO BALLAST BEFORE CONNECTING TO POWER OUTLET - Connect the Sirocco power cable to the ballast. - Securely lock the power cable connector to ballast socket. - Connect ballast to appropriate power supply. - Reverse procedure when shutting down your Sirocco unit. HI-T 1000W HI-BT37 1000W / HMI 1200W HMI 2500W ON ON OF F Maintenance Lamp It is important to inspect lamps regularly, and replace lamps showing signs of wear and tear. (i.e. cracked lamp, small fragments of glass or filament inside the lamp, or whitened lamp glass). Failure to do so could cause lamp failure, or possibly explosion, resulting in bodily injury and/or damage to the Sirocco unit.. To replace a lamp, please refer to Lamp Replacement Instructions in this manual. Envelope A damaged envelope must be repaired or replaced immediately. Regularly clean the envelope with mild soap and water. Citrus-based cleaners can be used, although be sure to test a small area before cleaning entire envelope. Patching A Hole o Be sure to thoroughly clean the area to be patched with mild soap and water and allow to dry. o Cut a square patch out of the included self-adhesive fabric sheet that is one inch wider and longer than the hole to be sure you can cover the entire damaged portion of the envelope. o Remove the protective film from the adhesive side of the patch material. o Carefully place the patch onto the damaged part of the envelope, firmly applying pressure to the areas of contact around the patch edge. Cleaning The Air Filter Remove sponge-type air filter, located under the south pole plate, by sliding along the support stand. Wash it or replace it Place clean air filter by the same way. 02-07-2012 / 65-63-072 B 10

Warranty At Airstar, we are very proud of our quality control and the reliability of our Sirocco product line. We also understand that there will occasionally be issues that require warranty service, so we offer the following coverage: Your Sirocco envelope, electronics, and structural components (excluding lamps) are guaranteed against manufacturing defects for 1 (one) year from the date of purchase. In the event of a manufacturing defect or possible warranty issue, call your Authorized Airstar Dealer to initiate a warranty claim. Send your Sirocco unit, along with a copy of your original invoice, to your Authorized Airstar Dealer for technical analysis. An Airstar certified technician will determine if your issue is covered under warranty. After repair, Airstar will return your Sirocco at our expense, via ground shipping. (Express available at extra charge.) If complete unit replacement is required, Airstar only ship replacement unit after receiving original unit. Airstar will not be held responsible for improper handling by the end user. Any operations on the envelope or electronic equipment that is not described in this manual, or any use of unapproved tools, components or lamps is not covered by this warranty and remains the sole responsibility of the user. Technical data sheets Units Sirocco 2 M HA 2x1000W Technical Data Sheet Sirocco 2 M HA 4x1000W Sirocco 2 M HI CR 4x150W E27 Sirocco 2 M HI-BT37 1000W Sirocco 2 M HMI 1200W Sirocco 2 M HMI 2500W Power supply V 120V 120 120V 220V 120V 230V 208V Hz 60Hz 60Hz 60Hz 60Hz 60Hz 50Hz 60Hz Luminous flux Lm 54000 Lm 108000 Lm 58000 Lm 115000 Lm 110000 Lm 240000Lm Lamp Qty - 2 4 4 1 1 1 Power Per Lamp W 1000 W 1000 W 150 W 1000 W 1200 W 2500 W Bulb type - HA HA Metalhalide Metalhalide HI-BT37 M47 ANSI Bulb socket - R7S R7S MEDIUM E27 E39 G38 G38 Restrike type - Hot Hot Cold Cold Hot Hot Restrike time s Instant Instant >7 minutes >7 minutes <10 seconds <10 seconds Power supplied by exterior ballast - No No No (Built-In) Yes Yes Yes Colour temperature K 3200 K 3200 K 3000 K 3700 K 5600 K 5600 K Average bulb life h 300 h 300 h 12,000 h 12,000 h 750 h 500 h Protection type - Pressure switch Pressure switch Thermal cut-off Pressure switch HMI Pressure switch HMI Pressure switch Anti-vibration system - Yes Yes Yes Yes Yes Yes Envelope diameter in. 35.5 in 47 in 35.5 in 47 in 47 in 55 in Envelope shape - Tubular Tubular Tubular Tubular Tubular Tubular Bulb luminous efficacy Lw/W 27 Lm/W 27 Lm/W 97 Lm/W 115 Lm/W 92 Lm/W 96 Lm/W Weight lbs 11 lbs 20.7 lbs 16.5 lbs 14.3 lbs 16.5 lbs 18.3 lbs Power W 2020 W 4020 W 690 W 1100 W 1300 W 2700W Power generating unit KVA 3 KVA 5 KVA 1 KVA 2 KVA 2 KVA 5 KVA 230V 50Hz 02-07-2012 / 65-63-072 B 11

10255 General Drive Unit A6 ORLANDO, FL 32824 USA Tel: (407)851-7870 Fax: (407)851-7831 www.airstar-light.us e-mail : info@airstar-light.us 02-07-2012 / 65-63-072 B 12