PRESSUREGUARD APM OWNER S MANUAL. PressureGuard APM Bariatric. Span-America Medical Systems, Inc. Greenville, SC

Similar documents
Key Product Features. Primary Use: Aggressive Treatment of Pressure Ulcers

PressureGuard APM 2 and PressureGuard APM 2 Safety Supreme

Series. PressureGuard EASY AIR OWNER S MANUAL. PressureGuard EASY AIR XL. PressureGuard EASY AIR LR. PressureGuard EASY AIR

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

Panacea AIR PRO MATTRESS. Owner s Manual. Please keep and refer to this Owner s Manual.

Paradise Pump Series Operator s Manual

Alternating Pressure / Low Air Loss Mattress System

Med Aire Alternating Pressure Pump and Pad System

PressureGuard Custom Care Convertible LAL. Series

SELECT SERIES LS200 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

Air Plus User Manual

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

USER MANUAL. AltaDyne XT Model A AltaDyne XD Model A Alternating Pressure / Low Air Loss Replacement Mattress System

Instruction Manual for Configura Cushionair Portable Pump

Operator s Manual. Dynamic Low-Air-Loss Therapy with Alternating Pressure

MA90 Series Mattresses. MA95 Series Mattresses

RIK Fluid Overlay INSTRUCTIONS FOR USE

MA60 Series. MA60 Alternating Pressure System. MA65 Alternating Pressure On-Demand Low Air Loss System. Owner s Operator and Maintenance Manual

Use this key to determine which sections of this Product Manual apply to your job.

UL COVERAGE IS FOR THE AIR SUPPLY ONLY

Contents. Introduction...1 About Breeze... 1 Breeze Overlay... 2 Breeze Mattress Replacement... 2 Breeze Pump... 4 Controls and Indicators...

User Manual. This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.

Joerns Healthcare. transforming wound management. User-Service Manual TriLine Support Surface. To avoid injury, read user s manual before using.

AltaDyne AutoFloat. Alternating Pressure Management Plus. Model # Model # OPERATORS MANUAL

SELECT SERIES LS300 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

770000S CLINICAL MAX LOW AIR LOSS WITH ALTERNATING PRESSURE SYSTEM USER MANUAL

LOGIC RANGE AUTOMATIC PRESSURE

User Manual soft air wds

ComfortGel SE support surface Operations Manual

User Manual. 10. Dimensions and Ordering Codes. Integrity Alternating Pressure Mattress System. Alternating Pressure Mattress Systems

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

SALISBURY ACTIVE OVERLAY SYSTEM

NIMBUS range. with people in mind

microair MA65 Series Alternating Pressure Low Air Loss Mattress User Manual MA65, MA65B42, MA65B48, MA65RSR

User Guide Antidecubitus systems EURO BASIC

PressureGuard Custom Care Convertible Series

Lateral Turning System. User Guide.

User Manual. soft air simplex wds. Health. Security. Independence. Pressure ulcer prevention and treatment-system Assembly and Operation instructions

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

User-Service Manual Joerns Support Surface FlapCair. To avoid injury, read user s manual before using.

Cobi Positioning Cushions

SC505 Sof Care Inflator. Operating Instructions and Service Manual

User Manual DIRECTHEALTHCARESERVICES.CO.UK

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

Arise 1000EX Low Air Loss Therapy Mattress. Operations/Maintenance Manual. Model 2236

User manual STARLOCK. Careways International - Innovation Quality Performance

Actively supporting your health.

OWNER S MANUAL. Span America Medical Systems, Inc. Greenville, SC

USER MANUAL. AirPal Air Supply. (AS-1100 North America) 1488 Limeport Pike, Coopersburg, PA airpal.com fax

12V AIR STATION ALL-IN-ONE

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

User-Service Manual Joerns Healthcare Advanced Wound Care Integrated Bed System DolphinCare Fluid Immersion Simulation with UltraCare XT

accidents which arise due to non-observance of these instructions and the safety information herein.

USER MANUAL LTH-255A Hand Piece

PDY TON HYDRAULIC CRIMPING TOOL WARNING

Turnout gear is comprised of boots, coat, pants, suspenders, hood, gloves, helmet, and SCBA Facepiece.

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

ALPHAXCELL. Active pressure relieving mattress overlay system for medium risk patients in all environments

35 TON HYDRAULIC PUNCH WARNING

Model PSI Compressor with 3-Gallon Air Tank 12VDC

better science. better care. Product Catalog

2015 Products Catalog Product Catalog. Products designed for the treatment and prevention of wounds

EVERYONE KNOWS WE WORK BEST UNDER PRESSURE. + WE CAN HANDLE MOISTURE TOO. ROHO S/A

DYNAMIC COMPRESSION THERAPY

My CoughAssist. A patient guide to CoughAssist T70. Please visit

User Manual DIRECTHEALTHCARESERVICES.CO.UK

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

8675/8677/8678 OWNER S MANUAL

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

5110 N / 5110 W. Installation & Operation Manual Series Stretchers. Part Number: /13

MODEL NUMBER: P PORTABLE COMPRESSOR

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Operations/Maintenance Name of Manual

Use and Care Guide. PMU and PMU w/over the Patient. Swing Mount. Over the Patient. Side Delivery

INDUSTRIAL - SOLVENT PARTS CLEANER

Precioso series 2. Prevention and therapy for everybody, everyday NURSING-CARE HEALTHCARE

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Installation and Operation Manual

MODEL NUMBER: P PORTABLE COMPRESSOR

Suction Regulators. Recommendations for Cleaning, Disinfection and Reprocessing: Boehringer 3800 &3900 Series Suction Regulators

User Manual DIRECTHEALTHCARESERVICES.CO.UK

Instructions for Use. OptiLife Nasal Lab Mask

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

IMMERSION SUIT MAINTENANCE GUIDE IMMERSION SUIT MAINTENANCE GUIDE 1409 SERIES. SCMG003A Maintenance Guide - Immersion Suits USA ENGLISH.

IsoAir. Operation/Maintenance Manual. Stryker Customer Service: /12 AO-SM-70-C REV 4.00

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Cascade Patient Transfer Lift System Safe Operation & Daily Maintenance Instructions

TJF-Q180V Cleaning and Disinfection Checklist

OWNER S MANUAL. Page: 1 of 8

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

PRESSURE REDISTRIBUTION SYSTEM. with people in mind

CPR MEDICAL DEVICES INC. OPERATING MANUAL

Transcription:

PRESSUREGUARD APM OWNER S MANUAL PressureGuard APM Bariatric Span-America Medical Systems, Inc. Greenville, SC 29615 800-888-6752

TABLE OF CONTENTS DOCUMENT SYMBOLS...1 INTRODUCTION... 2 Indications General Description Modes of Operation FEATURES...4 DIRECTIONS FOR SET-UP...5 DIRECTIONS FOR USE 7500 CONTROL UNIT with PRESSUREGUARD APM BARIATRIC...7 GENERAL DIRECTIONS FOR USE...9 Bed Linens Bed Rails CPR Storage Warranty Use in Wound Care CLEANING and DISINFECTION...10 SPECIFICATIONS...11 ORDERING INFORMATION...12

Document Symbols This manual contains different typefaces and symbols to make the content easier to read and understand: Standard text used for regular information. Boldface text stresses a word or phrase. NOTE: - sets apart special information or important instruction clarification. The symbol below identifies a WARNING or CAUTION: - A WARNING identifies situations or actions that may have an effect on patient or user safety. Ignoring a warning could cause patient or user injury. - A CAUTION points out special procedures or precautions that persons must obey to avoid equipment damage. The symbol below identifies an ELECTRICAL SHOCK HAZARD WARNING: Warning: This product contains/may contain chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm. 1

INTRODUCTIONPRESSUREGUARD APM Alternating Pressure Mattresses DESCRIPTION: The system consists of a foam shell with a high-density foam topper serving as the support surface underneath the patient. The foam shell also includes contoured foam bolsters at the sides and ends of the mattress, providing added patient stability and positioning. The system also includes the unique Heel Slope feature, designed to further reduce pressure for the sensitive heel area. Within the foam shell is housed the inflation system, consisting of air cylinders which run lengthwise within the mattress. The air Control Unit connects to the mattress at the patient foot-end. INDICATIONS FOR USE: The PressureGuard APM (Alternating Pressure Mattress) are powered, flotation therapy mattresses providing a pressure management surface for the prevention and treatment of pressure ulcers. MODES OF OPERATION: The PressureGuard APM Bariatric provides alternating pressure in a programmable cycle time. WARNING - To reduce the risk of electrocution READ ALL INSTRUCTIONS BEFORE USING THIS UNIT. 1. Always unplug this unit immediately after using. 2. Do not operate near water. 3. Do not place or store product where it can fall or be pulled into a tub or sink. 4. Do not place in or drop into water or other liquid. 5. Do not reach for a product that has fallen into water. Unplug immediately. 6. Use this unit only for its intended use as described in the operating instructions. 7. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Contact Span-America Medical Systems, Inc., for return of Control Unit for examination and repair. 8. Keep the cord away from heated surfaces. 9. Never drop or insert any object into any opening or hose. 10. Do not use outdoors. WARNING: POSSIBLE EXPLOSION HAZARD IF USED IN THE PRESENCE OF FLAMMABLE ANESTHETICS. RISQUE D'EXPLOSION NE PAS EMPLOYER PRES DE GAZ ANESTHESEQUES INFLAMMABLES. 2

Cover Air Cylinders Foam Topper with Geo-Matt design Safety Edge bolster Model 7500 Bariatric 3

COMMON FEATURES All APM Models The air-cylinder inflation system and the foam shell work in concert to maintain low interface pressures throughout the surface, making the APM family of mattresses effective for prevention and treatment of pressure ulcers. Cover [Illustration item ] The bacteriostatic top fabric is fire resistant, fluidproof, tear resistant, cleanable, and replaceable. The pleated design allows full integration with the mattress s Geo-Matt style shear-relieving surface while minimizing hammocking. Foam Topper: [Illustration item ] The Geo-Matt style foam topper is a high density, medical grade foam. The unique geometric design consists of over 800 individual cells, each of which acts individually to redistribute pressure, to reduce heat and moisture buildup on the skin, and to reduce shear to underlying tissues. This foam topper is 2" in height and includes the unique Heel Slope feature, designed to further reduce pressure for the sensitive heel area. Safety Edge Bolsters [Illustration item ] The Safety Edge consists of contoured foam bolsters around the sides and ends of the mattress for added patient stability in sitting and lying down. Air Cylinders: [Illustration item ] The inflation system consists of six urethane air cylinders, that run head to foot underneath the body and the foam topper. These cylinders perform the alternating pressure therapy, Cylinders inflate and deflate in a selectable cycle on the Bariatric Model The cycles and inflation levels are designed to provide and maintain low interface pressures throughout the mattress, and to redistribute peak interface pressure points during the alternating cycle. Control Units: Model 7500 PressureGuard APM Bariatric Solutions 4

DIRECTIONS FOR SET-UP 1. Place the PressureGuard mattress on the bed frame with the air line connectors at the foot end of the bed. Hospital-grade models have a gray vinyl side that should be down on the bed frame, a green fabric side that should be face up toward the patient. 2. Hang the PressureGuard Control Unit unit on the end of the bed using the hanger, or place it on a stable horizontal surface. 3. Insert the connectors at the ends of the air lines into the corresponding connectors on the side of the mattress. Ensure that the air lines are not kinked, twisted, or compressed by the mattress or the bed frame. Push in securely until you hear a "click". 4. Connect the other ends of the air lines into the corresponding connectors on the Control Unit. they will click into place as they do on the side of the mattress (Bariatric Control Unit, model 7500). 5. Ensure that the ON/OFF switch on the Control Unit is in an OFF position. Plug the power cord into an electrical outlet. Switch the Control Unit to ON. The POWER ON light is now illuminated. 6. Allow the mattress 20 minutes to inflate fully before placing a patient on the surface. 5

DIRECTIONS FOR USE OF 7500 CONTROL UNIT WITH PRESSUREGUARD APM BARIATRIC 1. Switch the power ON. The green power on indicator light on the switch will come on and the control unit will emit a beep. 2. CYCLE TIME and COMFORT LEVEL are both pre-set in the middle range. The control unit will default to these settings. Change settings as desired, for patient comfort. All settings are within therapeutic ranges, even the softest and firmest comfort levels. 3. ALARM RESET LIGHT: Indicates that factory pre-set inflation levels have not been reached. When the control unit is first turned on, the mattress should reach the preset level within approximately 30 minutes. If preset level cannot be reached within 30 minutes, the unit will continue inflating for an additional 15 minutes. If preset level still cannot be reached, the alarm will beep and the red LED will come on to signal a low pressure condition. To mute the audible alarm, press ALARM RESET. The alarm LED will begin blinking and will remain blinking until correct inflation level is reached. To reactivate the audible alarm, press ALARM RESET again. WARNING: If the red ALARM RESET light indicating a low pressure condition does not turn off, check to see that all air line connections are securely and correctly installed. If no obvious connection problem can be corrected, contact local dealer, or call Span-America customer service at (800) 888-6752). 4. After proper inflation is indicated, and you have prepared the patient surface, place the patient on the system. Select the preferred mode of operation: a. STATIC: This mode provides powered flotation, in which the system continually 6

adjusts as necessary to maintain patient support at the chosen comfort level. Caregiver may prefer this mode for transfers, dressing changes, feeding, and related activities. b. ALTERNATING: The mattress surface remains level and provides alternating pressure in one of four cycle time options 20, 25, 30, or 35 minutes. Of the six cylinders in the APM Bariatric, two cylinders deflate at one time in the following pairs: 1-4, 2-5, and 3-6. One cycle consists of the relative deflation and reinflation of one pair of cylinders. The pairs of cylinders deflate and inflate in the order shown. c. AUTOFIRM: Press the AUTOFIRM button to automatically inflate the mattress to the maximum level for 30 minutes. The pressure will return to the previously set level after 30 minutes. This may be used for patient transfers, for extended edge-of-bed sitting, or for CPR. POWER LOSS/PATIENT TRANSPORT: In case of loss of power, or while transporting a patient on the mattress: disconnect the air lines from the Control Unit and push the Transport Cap in place on the ends of the airlines. This will seal the air in the mattress for days or weeks. AIR FILTER PREVENTIVE MAINTENANCE: The air filter for the Control Unit should be checked routinely for signs of dirt or contamination. The frequency for cleaning depends on the air quality. The air filter is accessible from the back of the Control Unit and is covered by a removable tan colored cover. As the filter is white, the need to clean is obvious. Simply remove the cover, remove the filter, and hand wash using warm water and mild detergent. Rinse thoroughly and allow to air dry. Replace the filter and clip the cover back into place. 7

GENERAL DIRECTIONS FOR USE OF ALL MATTRESS MODELS BED LINENS: Seven-inch deep fitted sheets are recommended. Multiple layering of linens or underpads beneath the patient should be avoided for the prevention and treatment of pressure ulcers. For Safety Supreme version, it may be easier to use flat sheets, knitted stretch-fit sheets, or deep-pocket fitted sheets. CAUTION: Be careful not to puncture the mattress with needles or sharp instruments. This may result in loss of integrity of the cover or internal air system. Regularly inspect the mattress cover for cuts, rips, cracks or tears. Do not use the mattress if the cover is damaged. BED RAILS: Due to concerns over the possibility of patient entrapment, Span-America recognizes that the use of rails of any length is a matter currently addressed by various regulations from local, national and international government agencies, and by individual facility protocol. It is the responsibility of the facility to be in compliance with these laws, which typically require that decisions on the use of bed rails of any type are based on assessment of the physical and mental status of each patient individually. If bedrails are needed by the patient to prevent fall-related injury, as determined by this assessment, we recommend that the bedrails be locked in the up position at all times. CPR: The Standards for Life Support recommended by the American Heart Association for performing CPR recommend a hard level surface for performing CPR. This means moving the person to the floor if possible. For performing CPR on the PressureGuard APM 1. Place a crashboard beneath the patient. 2. Select AUTO FIRM. 3. Follow CPR procedures. STORAGE: Always store the surface flat on a clean, level surface. Avoid storage of other equipment on top of the mattress. When removing the mattress from storage, always ensure the internal inflation system is aligned correctly prior to placing a patient on the surface. WARRANTY: All PressureGuard APM models are unconditionally guaranteed against failure due to manufacturing defects under normal use for 18 months. USE IN WOUND CARE: Use of PressureGuard APM models is only one element of care in the prevention and treatment of pressure ulcers. Frequent repositioning, proper care, routine skin assessment, wound treatment and proper nutrition are but a few of the elements required in the prevention and treatment of pressure ulcers. As there are many factors that may influence the development of a pressure ulcer for each individual, the ultimate responsibility in the prevention and treatment of pressure ulcers is with the health care professional. 8

CLEANING and DISINFECTION All Models Only the cover requires cleaning and maintenance. Disassembly of the support surface for maintenance of internal components of the Control Unit or mattress is not recommended. Cover can be wiped clean with neutral suds and lukewarm water. Rinse and dry. For hard to clean spots, use standard liquid household/vinyl cleaners with a soft bristle brush. CAUTION: DO NOT USE HARSH CLEANERS OR SOLVENTS. For long-term incontinent applications, clean and disinfect cover daily. A scented cleaner/disinfectant is recommended. Iodophor type disinfectants (Betadine for example) will stain the fabric. For disinfection, phenolic or quaternary type disinfectants are recommended. Disinfectants should be hospital grade (tuberculocidal). Follow manufacturer s instructions for use concentrations, contact times and rinsing. Contamination with blood on the fabric can be disinfected with a 1:10 dilution of household bleach (5.25% sodium hypochlorite) as recommended by the CDC. The use of bleach at improper dilutions may result in fabric discoloration and fluid pass-through. Where surveillance and epidemiology indicate ongoing transmission of C. difficile, an EPAregistered hypochlorite-based disinfectant is recommended. Follow the manufacturer s instructions for use concentrations, contact times and rinsing. Generic sources of hypochlorite (e.g. household chlorine bleach) may also be used. Prepare the disinfection solution fresh daily at a 1:10 dilution. Improper dilutions may result in ineffectiveness and higher than recommended concentrations will damage the fabric. Note: alcohol-based disinfectants are not effective against C. difficile and should not be used to disinfect environmental services. For further information relative to this organism and infection control in the healthcare setting, please refer to www.cdc.gov/ncidod/hip. Disinfect mattress covers following contamination with bodily fluids and between patients. Inspect the covers and zipper area for signs of damage, puncture, or wear that could result in fluid pass-through. If the cover is stained, soiled, or torn, inspect the internal components for signs of contamination. Allow cover fabrics to air dry (approximately 20 30 minutes) before use. WARNING: If contamination is evident, quarantine the mattress and remove from service following infection control procedures. 9

SPECIFICATIONS COVER: Bacteriostatic, flame resistant, fluidproof, tear resistant FOAM: High-density open-cell polyurethane. Conforms to NFPA 101 small scale and Cal TB# 117.. AIR CYLINDERS: Urethane and/or Fabric Coated PVC ELECTRICAL: All control units 120 V, 60 H. All control units UL listed. Bariatric units also conform to UL 60601-1 and CAN/CSA C22.2 NO. 601.1 SURFACE SIZES: 80 L X 42 W - Bariatric 80 L X 48 W - Bariatric 80 L X 54 W - Bariatric MATTRESS HEIGHT: WEIGHT LIMIT CYCLE TIME: PLACEMENT WARRANTY: 7 for all models 750 lbs. for bariatric models Programmable cycles for Bariatric All mattresses can be placed directly on a hospital bed frame or standard bed frame or box spring. 18 months, not pro-rated, against manufacturing defects. 10

ORDERING INFORMATION Product Name Catalog Number Mattress Size PressureGuard APM Bariatric AP8042-29 80 L X 42 W X 7 H with 7500 Control Unit AP8048-29 80 L X 48 W X 7 H AP8054-29 80 L X 54 W X 7 H AP8442-29 84 L X 42 W X 7 H AP8448-29 84 L X 48 W X 7 H AP8454-29 84 L X 54 W X 7 H Replacement Air Systems For 80 /84 x 42 For 80 /84 x 48 For 80 /84 x 54 P09371 P09372 P09373 7500 control unit only (Bariatric) 7500 Replacement Airlines only APM Bariatric P02674 All Models comply witg 2000NFPA 101 (life Safety Code), Cal TB # 127 and 16 C FR 1632 and 1633. Call Customer Service (800-888-6752) for information on coverlets, transport bags, and other available accessories. 11

THIS PRODUCT IS PROTECTED BY ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 6,848,138 6,223,369 SPAN-AMERICA MEDICAL SYSTEMS, INC. Greenville, SC 29615 800/888-6752