ACCU-MIX 1200 / / 26270

Similar documents
TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

TITAN FLOW CONTROL, INC.

EQUIPMENT Operation Manual. Loctite Stainless Steel Poppet Valve Part Number

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

SC HYDRAULIC ENGINEERING CORPORATION

FLOW CONTROL & AIR PILOT SWITCH VALVES

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

Installation Instructions JATCO Environmental Protection Tank Model J-7000

ROPV R40 E Series User Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

Cocoa Patio Pond with Lit Spillway

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

92831 TEL: (714) FAX:

Accu-Tab Systems 2000 P Series by Axiall Corporation

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Accu-Tab Systems 1000 Series by Axiall Corporation

Interface Devices, Inc. Hydraulic Mini Mule

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

KJ4000 Operating Instructions & Parts Manual NSN

G7S Hand Pump Owner s Manual

Model Series 62 Constant Differential Relay

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

WEATHERIZING INSTRUCTIONS

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Vessel Installation and Operating Manual

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

User Instruction Manual

92831 TEL: (714) FAX:

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Installation & Instruction Manual For Portable Series R.O. units:

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Model No Product Name Handpiece Only Complete System

Accu-Tab PowerBase 3012AT by Axiall Corporation

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Accu-Tab PowerBase 3070AT by Axiall Corporation

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Geotech 1.66 Auto-Reclaimer

Installation and Operating Manual

INSTRUCTIONS FOR SINGLE STAGE LECTURE BOTTLE REGULATORS

BS Series Basket Strainer

Geotech 1.66 Auto-Reclaimer Installation and Operation

Color/Catalyst Dispense Valves

INSTRUCTIONS FOR FM4460N SERIES HIGH PRESSURE, METAL TUBE FLOWMETERS

CATALYZER TM 2K 10:1 RATIO Pump

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

D Series Air and Water Kit Part# 02550

FLANGED TWO-PIECE BALL VALVES

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTRUCTIONS FOR SERIES 150 TWO TUBE GAS BLENDER

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Model ASSEMBLY and OPERATING INSTRUCTIONS

Model 9201E Tempered Water Blending System

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Instruction Manual Model Borehole Pressure Cell

CF-SERIES HIGH FLOW REGULATORS

Pressure Relief Valve Instruction Manual

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

FLANGED TWO-PIECE BALL VALVES

SERIES L4E & L6E LADDER EXTENSIONS

Fire-Ball 300 and 425 Grease Pumps

Back Pressure Regulator

Gas and Vacuum Tubing Connection Kit for Manual Operation, No

Tsunami Breathable Air System

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

J Air and Water Kit Instructions Part# 02584

AND OPERATION INSTRUCTIONS

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

FLANGED MULTI-PORT BALL VALVES

Installation and Operating Instructions

Installation, Operation and Maintenance Manual

TITAN FLOW CONTROL, INC.

PC1131 Electric Air Compressor

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Sterile Visual Flow Indicator

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

INSTRUCTIONS PARTS LIST

This document to be used with Hurley traditional Davits

INSTRUCTION MANUAL GAS TRAK

Marschalk Model # 94000

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Transcription:

ACCU-MIX 1200 / 14100 / 26270 Model 102006 (1200) Model 102002 (14100) Model 102003 (26270) Pre filter is required when the water supply is from a in house un filtered well to retain the warranty. Pre filter is not required with a municipal water supply to retain the full warranty. Accumix 1

T.S.P. ACCU-MIX PISTON PROPORTIONERS Part # P1200 Part # P14100 Part # P26270 Principle of operation: Water, under pressure, drives a reciprocating piston in the water motor cylinder. This piston, in turn, drives the chemical concentrate metering piston that draws concentrate from the drum and injects it into the water from the water cylinder. Reduce chemical waste: Reliable: Non-Electrical: Adjustable: Because T.S.P. Accu-Mix is water flow responsive, concentrates will be diluted as intended irrespective of variations in plant water flow or pressure. The T.S.P. Accu-Mix is a precision metering instrument manufactured to the most exacting specifications. It is uncomplicated and has few moving parts. We feel simple is best. Because T.S.P. Accu-Mix is water operated, expensive and oftentimes complicated electrical connections are unnecessary. Personnel are not exposed to the shock hazards associated with electrical chemical injectors. The concentrate to water ratio is completely adjustable within the various model ranges. Accumix 2

ACTUATING ARM TOGGLE LEVER ASSEMBLY COVER (SPRING INSIDE) OUTLET CONCENTRATION ADJUSTMENT KNOB WATER INLET ADJUSTMENT: LOCK KNOB CHEMICAL PUMP UPPER VALVE SCREW WATER MOTOR UPPER VALVE BLOCK MAIN CYLINDER MAIN PISTON (INSIDE) END PLATES CHEMICAL PUMP BALL CHECKS INSTALLATION PUMP HEAD FIG. 1 LOWER VALVE SCREW SUCTION TUBE 1. Mount the proportioner on a bracket or shelf using the 4 PVC plastic spacers and the rubber feet provided. Unscrew the rubber feet and place the PVC spacer between the proportioner and the rubber feet. Replace the feet. If placing on drum mount the unit so the bottom of the bracket is 42 from the floor. This will allow a drum of product to be placed under the unit. 2. Not included / optional. Install a 25 micron water filter in the inlet line of the porportioner. Failure to filter the porportioner water supply will void warranty. If the Inlet water pressure can exceed 75 PSI, a regulator should be installed in the inlet line. Note: The proportioner has ¾ garden hose adapters for both the inlet and outlet. The unit can be connected to rigid pipe by removing the ¾ garden hose adapter from the plastic housing. 3. To the discharge side of the proportioner install the post homogenizer. Find Mixing Chamber. Install to the outlet of the proportioner, attach the female threads of the housing to the male threads of the proportioner and connect a pipe or line to a central reservoir or points of use. (Disregard In and Out designation on top of housing.) 4. Attach the suction tube to the chemical pump and place the bottom end of the tube into the product container. PART # 102002-9 OPTIONAL WATER FILTER Accumix 3

Accumix 4

START POINTS FOR CONCENTRATIONS SETTINGS ARE AS FOLLOWS: Determine the proper concentration of product that best suites your needs: After the initial priming procedure is complete adjust the concentration adjustment knob to the desired setting per the following table bellow. This is a staring point only and should be checked with an appropriate refractometer, obtainable through your Hangsterfer's Distributor. For Hangsterfer's Water Soluble Oil and Synthetic Concentrate ratio: PRODUCT WATER: MODEL MODEL MODEL CONCENTRATE 1200 14100 26270 Crystal Cut 322 & CT 11 30:1 3.5 3.5 1.5 20:1 5 7.5 3.5 HE-2 20:1 4 10:1 8 5:1 15 R-100 20:1 5 4 2 10:1 9 8 4 S-500 & S-500 CF 20:1 5 4 2 10:1 9 8 4 S-100 20:1 5 4 2 10:1 9 8 4 S-1001 20:1 5 4 2 10:1 9 8 4 S-400 20:1 5 3.5 1.5 S-747 20:1 5 4 2 10:1 9 8 4 S-777 20:1 5 4 2 10:1 9 8 4 S-787 20:1 5 4 2 10:1 9 8 4 These setting points are estimated and should be checked and adjusted per your application. These Accu-Mixes work on a water pump principle and a pail should be filled to check the concentration. As the unit pumps forward it is at a higher concentration and the back pump at a lesser concentration. Both pump actuations equal one full cycle of concentration or percentage. Accumix 5

TROUBLESHOOTING COMPLAINTS CAUSES: CORRECTIONS: A. Water motor will not run. A. Water turned off. A. Turn water on to unit. B B. Water filter clogged. B. Remove and replace filter elements. C. Discharge lines shut C. Check to be sure lines are off or clogged. clear and all system valves are open. D D. Proportioner stalled D. Water inlet pressure has proportioner operates dropped. Receive down intermittently- then stream back pressure if unit stalls. restarts, there is no problem. If not the valve block must be rebuilt. 2. WILL NOT DRAW CHEMICAL. C E. Weak or broken lever E. Replace spring. spring. A. Water motor not A. Check motor per item 1 working. above. B. Proportioner concen- B. Re-adjust. Set to Max, trate adjustment set to prime. on minimum. E BALL SEAT C. Pump head/valves C. Remove top valve screw, dry. flood cavity with water. Replace spring and valve carefully. Start unit. D. Upper or lower valve D. Tighten fittings- hand screws are sucking air. tighten only. E. Foreign material on E. Remove valve balls, flush valve seat. Concen- and clean valve seats and trate has caused balls, replace balls, springs balls to stick. and valve screws. SEAT BALL F. Excessive discharge F. Relieve downstream back causing back pressure. pressure until unit is primed. Accumix 6

Accumix 7

Accumix 8

Accumix 9

CONSTRUCTION Water Motor: End Plates - Glass Filled Delrin (Acetal Resin) Main Piston - Glass Filled Delrin, 304 Stainless Steel Main Cylinder - 303 Stainless Steel Seals - Viton Upper Valve Block - 303 Stainless Steel Valve - 304 Stainless Steel Chemical Adjustment Assembly - Micro Adjusting Screw - Piston Rod - Stainless Steel Chemical Pump: Pump Head - 1200, 14100 Acrylic (standard) 26270 - PVC (standard) Upper and lower Valve Screws - Polyethylene Chemical Piston - Polyethylene 1200, 14100 - Poly 26270 - PVC Springs - Hastelloy C External Fittings - Polyethylene Chemical Compatibility: T.S.P. warrants that the materials of construction are as represented. It is solely the responsibility of the purchaser to ascertain component suitability for a particular purpose. T.S.P. assumes no responsibility for adverse chemical incompatibility. SPECIFICATIONS Specifications & Utility Requirements: Mixture Ratio Range: Please note below Water Temperature: Water Filtration: 40 F (4 C) to 180 F (82 C). 25 micron filtration recommended. MODEL MAX MIN P1200 1:8 (12%) 1:48 P14100 1:6 (16%) 1:48 P26270 1:3 (30%) 1:24 Water Pressure: 10PSI (0.7 Kg/CM 2 ) minimum. 75 PSI (5.3 Kg/CM 2 ) maximum. Water Flow Rate: Minimum flow 4.0 US GPH at minimum pressure. 7.0 US GPM at maximum pressure. *The dilution capabilities listed above presume, the chemicals are the approximate viscosity of water. A substantial increase in viscosity will decrease the Proportioners ability to draw concentrate, thus reducing the effluents potential concentration. Accumix 10

LIMITED EXPRESS WARRANTY 1. WARRANTY-T.S.P.. Hereinafter T.S.P., warrants to the original purchaser that T.S.P. equipment will be free in material and / or workmanship under normal use and service for a period of 6 months from date of sale (invoice date). T.S.P. liability shall, as its option, be limited to repair or replacement of the defective equipment. 2. CONDITIONS AND EXCEPTIONS A. T.S.P. shall be responsible only for parts and labor costs by T.S.P. and its personnel. Purchaser shall be responsible for all other repair and/or replacement costs included, but not limited to, freight and travel costs incurred by non-t.s.p. personnel. B. This warranty does not apply to any damage or loss to any equipment of component resulting from alteration or modification by unauthorized persons, fire, accident, acts of God, misuse or abuse, or failure to install or operate the equipment in strict compliance with the operating instructions, or any other cause whatsoever other than defects in workmanship and /or materials. 3. PURCHASER S OBLIGATIONS- All equipment is sold f.o.b. T.S.P. factory and all responsibility for, and risk of, loss or damage in transit is borne by the purchaser. Any claims, loss or damage resulting from shipment must be settled between purchaser and purchaser s freight carrier. 4. LIMITATION OF LIABILITY-T.S.P. SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT OF CONSEQUENTIAL DAMAGES. T.S.P. shall not be liable for loss of any income or profits due to the malfunctioning of any equipment covered by this Warranty, whether the malfunctioning is caused by defects in workmanship and/or materials, or for any cause whatsoever. The remedies of purchaser set forth herein are exclusive, and the liability of T.S.P. with respect to any contract or sale or anything done in connection therewith, whether in contract, in tort under any warranty, otherwise shall not exceed the price of the equipment or parts on which such liability is based. 5. MERGER-THE WARRANTY DESCRIBED IN THE ABOVE PARAGRAPHS SHALL BE IN LIEU OF ANY OTHER WARRANTIES, EXPRESS, OR IMPLIED, INCLUDED BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR MERCAHTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE. T.S.P. NEITHER ASSUMES, NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT, ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OR USE OF THE EQUIPMENT SOLD HEREUNDER, AND THERE ARE NO ORAL AGREEMENTS OF WARRANTIES COLLATERAL TO, OR AFFECTING THIS AGREEMENT. Accumix 11

Accu-Mix 14100 Model # 102002 Accumix 12

Accu-Mix 14100 Model # 102002 Accumix 13

Accu-Mix 26270 Model # 102003 Accumix 14

Accu-Mix 26270 Model # 102003 Accumix 15

Accu-Mix 1200 Model # 102006 Accumix 16