INSPIRE Min.I. Redefining minimally invasive approach to perfusion. Expand your choices with INSPIRE Min.I.

Similar documents
INSPIRE TM C The integrated closed system oxygenator for gentle perfusion

INSPIRE Oxygenator Family

INSPIRE TM Inspired choice

INSPIRE TM8 PH.I.S.I.O.

INSPIRE 6 PH.I.S.I.O.

Adult All Integrated Mini Bypass System

A complete family of Pediatric Perfusion Systems

S5 TM. Min.I. Mini Maxi Me. The proven safe and reliable, world-leading perfusion system, now optimized for minimally invasive and pediatric surgery

Min.I. Mini Maxi Me. The proven safe and reliable, world-leading perfusion system, now optimized for minimally invasive and pediatric surgery

Optimized Perfusion Management and Patient Outcome

CAPIOX FX Advance. Oxygenator with Integrated Arterial Filter and Hardshell Reservoir

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists

QUADROX-i Neonatal & Pediatric Maximum safety for the smallest patients.

OxygenatOrs QUaDrOx-i adult QUaDrOx-i small adult

Clinical Engineering. Equipment (Heart-lung machines)

Patients come in a range of sizes. Now your oxygenator does, too.

Considerations in Circuit Miniaturization

Prescriptive Oxygenation

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

ila ACTIVVE SYSTEM PLATFORM

CDI Blood Parameter Monitoring System 500 A New Tool for the Clinical Perfusionist

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

CAPIOX SX Family of Oxygenators

CAPIOX SX Family of Oxygenators

CAPIOX SX Family of Oxygenators

Emboli Production in Hardshell Venous Reservoirs at Low Reservoir Levels Devin Eilers, BS, Willie Glaze, BS, & David Holt, MA, CCT Clinical Perfusion

Blood Parameter Monitoring System 550

An In-Vitro Study Comparing the GME Handling of Two Contemporary Oxygenators

PERFUSION SYSTEMS MECC SMART SMART SUCTION SYSTEM

Citation for published version (APA): Somer, F. M. J. J. D. (2003). Strategies for optimisation of paediatric cardiopulmonary bypass s.n.

CDI System 500. Blood Parameter Monitoring System. Continuous blood parameter monitoring for improved blood gas management

Innovative cap to reduce the noise raised by bubbling activity drainage working (vent close)

The next generation of Blood and Fluid Warming

The next generation of Blood and Fluid Warming

Used with Dissolution Tester for Fraction and Flow Measurements

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

InFlow Modular perfusion bioreactor

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

INTERNATIONAL MARKETING. 61, avenue Tony Garnier Lyon France Tel.: 33 (0) Fax: 33 (0)

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

(12) United States Patent (10) Patent No.: US 6,524,267 B1

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

Making Life Easier Easypump II

A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

An In Vitro Study of the Effectiveness of Carbon Dioxide Flushing of Arterial Line Filters

Airox Supportair Ventilator

Point-of-Care Testing: A Cardiovascular Perfusionist s Perspective

Contacts. Quick Start Guide

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Recommendations for Standards. Monitoring. Cardiopulmonary Bypass

THE PMI ADVANCED PERM POROMETER

MEDAP-MOBILE GAS SUPPLY

Oxylog 3000 plus Emergency & Transport Ventilation

ENT 318/3 Artificial Organ. Artificial Lung. Lecturer Ahmad Nasrul bin Norali

EASYPUMP II THE FLEXIBLE SOLUTION FOR SHORT AND LONG TERM INFUSION THERAPIES

Indications for Use: Caution: Note:

tel: fax: web:

ekom Compressor for Medical Air Sonata with Ekom

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Lung Volumes and Capacities

Inspire rpap REVOLUTION FROM THE FIRST BREATH

CARDIOHELP System designed to save lives

Keep the balance in sight

Simplicity and Safety Prevention Efficiency and Biocompatibility

What is optimal flow?

Tensiometer For the measurement of surface and interfacial tension

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open.

Limitations Using the Vacuum-Assist Venous Drainage Technique During Cardiopulmonary Bypass Procedures

NEONATAL/INFANT VENTILATOR

Perfusion Safety Review in Japan

Average Volume Assured Pressure Support

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Tensiometer For the measurement of surface and interfacial tension

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

Mechanical Ventilation. Which of the following is true regarding ventilation? Basics of Ventilation

Unity Sleeveless Elevated Vacuum System

Degassing ERC KK Saitama, Japan

Alfred ECMO Circuit Priming and Storage Guide

BODYGUARD 2CH TWIN CHANNEL INFUSION PUMP

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

An In Vitro Analysis of a One-Way Arterial Check Valve

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

Panther 5 Acute Care Ventilator

Fluido AirGuard System

HAEMOFILTRATION GUIDELINES

Solutions for transcutaneous monitoring

Multi Channel Solutions

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

Technical Data and Specifications

swimming pool technology

Limb Perfusion Device

Collin County Community College. Lung Physiology

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

Transcription:

INSPIRE Min.I. TM Redefining minimally invasive approach to perfusion Expand your choices with INSPIRE Min.I. TM

MINIMALLY INVASIVE PERFUSION versatile system configurations air system management low hemodilution features is an innovative Minimally Invasive perfusion system bringing safety to the system level. allows a low hemodilution cardiopulmonary bypass (CPB). allows clinicians the choice of a high number of customized solutions. is available in both 6 LPM and 8 LPM sizes with or without integrated arterial filter. high biocompatibility, the safe system approach to minimally invasive perfusion with no compromise on performance. 3

Air system management Low hemodilution features Imagine A new, innovative, completely closed system that includes a venous bubble trap, centrifugal pump, oxygenator module with integrated arterial filter. And venous and arterial automatic systems to evacuate and guard against air emboli. INSPIRE Min.I. features APC and ERC venous and arterial air management devices, bringing safety of minimally invasive perfusion to a system level. From disposable to hardware INSPIRE Min.I. is a system, not just an integration of products. Reduced priming volume of the INSPIRE Mini.I. system components meets the requirements for a low hemodilution Cardiopulmonary Bypass procedure. Low hemodilution is one of the musts of minimally invasive CPB and is systematically related to decreased banked blood usage and decreased organ failure and lower morbidity. LivaNova's INSPIRE oxygenator modules, INSPIRE VBT 8, Revolution centrifugal pump, and INSPIRE Dual reservoir all share the basic principles of hemodilution reduction. INSPIRE VBT 8 NEW VENOUS BUBBLE TRAP Low priming volume Rated up to 8 LPM blood flow Excellent air removal performances in synergy with APC PH.I.S.I.O. (PC) coated Flexible holder to allow maximum degree of freedom to personalize HLM set-up 6 LPM 8 LPM INSPIRE 6 M 84 ml priming vol. INSPIRE 6F M 84 ml priming vol. INSPIRE 8 M 9 ml priming vol. INSPIRE 8F M 35 ml priming vol. AIR PURGE CONTROL (APC) Guards against venous air embolization Works synergistically with INSPIRE VBT 8 new venous bubble trap and a bubble sensor on the venous line Purged volume is saved and sent to the Mini CPB bag or to the cardiotomy reservoir INSPIRE VBT 8 8 ml priming vol. REVOLUTION 57 ml priming vol. ELECTRIC REMOTE CLAMP (ERC) Guards against arterial line air embolization exiting venous bubble trap Can be manually operated from the SCP Centrifugal Pump Control Console Prevents retrograde flow and closes when arterial flow drops to LPM INSPIRE HVR DUAL ml Min Op. level 45 ml venous collector priming vol. 3 ml venous filter hold-up vol. 4 5

Versatile system configurations High biocompatibility WIDE RANGE OF PTS SOLUTIONS HYBRID SYSTEM OPTIONS WITH INSPIRE HVR DUAL LivaNova s wide offering of PTS components allows to configure the most appropriate Perfusion Tubing System Hybrid systems represent the latest evolution in minimally invasive cardiopulmonary perfusion. The integration of a according to your individual needs. From stand-alone tubing systems and stand-alone devices to fully preconnected hard shell reservoir in the venous line facilitates blood management and helps to overcome any intra-operative issue Min.I. systems. requiring the conversion to a traditional open system. S5 CONFIGURATION OF CHOICE INSPIRE Min.I. system of choice works at its best when fitting S5 set-up and S5 accessories. LivaNova s S5 Heart-Lung Machine can be configured to better suit mast mounted INSPIRE Min.I. system set-ups with short A/V lines-low priming configuration. PH.I.S.I.O. PROTEIN OUTER SURFACE PHOSPHORYLCHOLINE (PC) CARBOHYDRATE INNER SURFACE PHOSPHORYLSERINE (PS) PH.I.S.I.O. PC coating PHOSPHOLIPID BILAYER The INSPIRE HVR DUAL Reservoir provides clinicians with an ideal solution to build an innovative Hybrid system, allowing also for activated suction blood separation in the same reservoir that handles venous blood. One of the goals of minimally invasive CPB is the minimization of foreign surface area in contact with blood and the minimization of consequent inflammatory response. INSPIRE Min.I. has reduced surface area in contact with blood and features PH.I.S.I.O. PC coating with proven effectiveness in reducing platelet activation and white blood cell adhesion to foreign surfaces. Activated suction blood sequestration, combined with PH.I.S.I.O. PC coating, offers maximum biocompatible benefits. The combination of the INSPIRE HVR DUAL Reservoir system, PH.I.S.I.O. PC coating and XTRA autotransfusion system, offers clinicians a comprehensive solution to enhanced biocompatibility. 6 7

Adult patient population and oxygenator of choice Performance charts Patient Body Weight & Distribution per INSPIRE Market Assessment Study (MAS) database % < 8 Kg 4% Kg % > Kg with INSPIRE 6 M with INSPIRE 8 M with INSPIRE 6F M with INSPIRE 8F M Yesterday's choice 5 LPM 6 LPM SMALL ADULT FULL ADULT LivaNova's vision INSPIRE TM 6 LPM Our INSPIRE 6 LPM oxygenator systems are the only optimized adult oxygenator systems with a low blood contact surface area which can minimize hemodilution and effectively control GME, while offering full performance up to 6 LPM maximum blood flow. This oxygenator module covers the requirements of a wide patient population. INSPIRE TM 8 LPM SMALL ADULT 6 Today's choice with INSPIRE OPTIMIZED ADULT From 5 to 6 LPM max blood flow rate 8 FULL ADULT The INSPIRE 8 LPM oxygenator systems provide superior performance up to 8 LPM, allowing clinicians to safely and comfortably treat all adult patients, while reducing hemodilution and effectively controlling gaseous micro-emboli (GME). INSPIRE 8 LPM oxygenator systems offer the ideal solution for powerful perfusion and have been designed to help clinicians standardize perfusion practice at the highest performance levels. Bovine blood - Hb ±. gr/dl - B.E. ±meq/l - Venous pco 45±5 mmhg - O Venous Sat. 65±5% - Blood Temp. 37± C - QG/QB= - FiO % - Qw=±,5 l/min INSPIRE 6 M Total O Transfer (ml/min) 4 3 3 3 4 5 6 7 O (ml/min) INSPIRE 6 M Total CO Transfer (ml/min) 3 3 3 4 5 6 7 INSPIRE 6 M Heat Exchange Efficiency,,8,6,4,, 3 4 5 6 7 INSPIRE 6 M Blood Path 3 3 4 5 6 7 Bovine blood - Hb ±. gr/dl - B.E. ±meq/l - Venous pco 45±5 mmhg - O Venous Sat. 65±5% - Blood Temp. 37± C - QG/QB= - FiO % - Qw=±,5 l/min O (ml/min) INSPIRE 8 M Total O Transfer (ml/min) 4 4 3 3 3 4 5 6 7 8 9 INSPIRE 8 M Total CO Transfer (ml/min) 4 4 3 3 3 4 5 6 7 8 9,,8,6,4, INSPIRE 8 M Heat Exchange Efficiency, 3 4 5 6 7 8 9 INSPIRE 8 M Blood Path 3 3 3 4 5 6 7 8 9 Bovine blood - Hb ±. gr/dl - B.E. ±meq/l - Venous pco 45±5 mmhg - O Venous Sat. 65±5% - Blood Temp. 37± C - QG/QB= - FiO % - Qw=±,5 l/min INSPIRE 6F M Total O Transfer (ml/min) 4 3 3 3 4 5 6 7 O (ml/min) INSPIRE 6F M Total CO Transfer (ml/min) 3 3 3 4 5 6 7 INSPIRE 6F M Heat Exchange Efficiency,,8,6,4,, 3 4 5 6 7 INSPIRE 6F M Blood Path 3 3 4 5 6 7 Bovine blood - Hb ±. gr/dl - B.E. ±meq/l - Venous pco 45±5 mmhg - O Venous Sat. 65±5% - Blood Temp. 37± C - QG/QB= - FiO % - Qw=±,5 l/min O (ml/min) INSPIRE 8F M Total O Transfer (ml/min) 4 4 3 3 3 4 5 6 7 8 9 INSPIRE 8F M Total CO Transfer (ml/min) 4 4 3 3 3 4 5 6 7 8 9,,8,6,4, INSPIRE 8F M Heat Exchange Efficiency, 3 4 5 6 7 8 9 INSPIRE 8F M Blood Path 3 3 3 4 5 6 7 8 9 Technical specifications VENOUS BUBBLE TRAP with INSPIRE 6 M with INSPIRE 8 M with INSPIRE 6F M with INSPIRE 8F M Max. blood flow rate 8 l/min 8 l/min 8 l/min 8 l/min Priming volume 8 ml 8 ml 8 ml 8 ml Screen filter micron size µm µm µm µm Screen filter surface area cm cm cm cm OXYGENATOR MODULE Maximum Blood Flow Rate 6 l/min 8 l/min 6 l/min 8 l/min Static Priming Volume (oxy module + heat exchanger average value) 84 ml 9 ml 84 ml 35 ml Membrane surface area (approx. value),4 m²,75 m²,4 m²,75 m² Heat Exchanger material Polyurethane Polyurethane Polyurethane Polyurethane Heat Exchanger surface area (approx. value),4 m²,4 m²,4 m²,4 m² Arterial Filter material type Polyester net Polyester net Arterial Filter micron size 38 µm 38 µm Arterial Filter surface area 68 cm² 97 cm² 8 9

Order guide HEARTLINK TM SYSTEM ITEM # DEVICE DESCRIPTION UNITS PER CASE IMAGE 589 INSPIRE VBT 8 INSPIRE VBT 8 VENOUS BUBBLE TRAP 6 INSPIRE TM Min.I. is a key component of the LivaNova HeartLink TM System: the first automatically integrated Perfusion Management System designed for improved patient outcomes, increased clinical efficacy and Goal-Directed Perfusion. 59 INSPIRE VBT 8 HOLDER INSPIRE VBT 8 HOLDER FOR VENOUS BUBBLE TRAP CONNECT TM HEARTLINK TM CARD 4 SYNERGY BAG HOLDER MINI BYPASS BAG RESERVOIR HOLDER 7 INSPIRE 6 M INSPIRE 6 LPM PHISIO OXY MODULE 7 INSPIRE 8 M INSPIRE 8 LPM PHISIO OXY MODULE GDP TM MONITOR 7 INSPIRE 6F M INSPIRE 6 LPM PHISIO OXY MODULE WITH INTEGRATED ARTERIAL FILTER 73 INSPIRE 8F M INSPIRE 8 LPM PHISIO OXY MODULE WITH INTEGRATED ARTERIAL FILTER S5 TM 75 INSPIRE HVR DUAL INSPIRE PHISIO DUAL HARD SHELL VENOUS RESERVOIR XTRA 64 INSPIRE BKT BRACKET FOR INSPIRE OXY MODULES AND INTEGRATED OXYGENATOR SYSTEMS 48-4-* INSPIRE BKT FAST BRACKET FOR INSPIRE OXY MODULES AND INTEGRATED OXYGENATOR SYSTEMS WITH FAST CLAMP 64 INSPIRE BKTH BRACKET FOR INSPIRE HVR AND DUAL HVR RESERVOIRS 49 TEMPERATURE PROBES TEMPERATURE PROBES *To be ordered as an accessory of LivaNova S5 and C5 HLMs.

LivaNova s Green Leaf program EN ISO 3485: According to Annex II (Full Quality System) of MDD 93/4/EEC as amended by diective 7/47/EEC 9/6 995-89 B Not for distribution in USA Manufactured by: Sorin Group Italia Srl A wholly-owned subsidiary of LivaNova PLC Via Statale Nord, 86 437 Mirandola (MO) Italy Tel. +39 535 98 - Fax +39 535 59 info.cardiacsurgery@sorin.com Refer to the information for Use provided with each product for detailed information, warnings, precautions and possible adverse side effects. 7 LivaNova all rights reserved.