APC Pressure Reducer with Sensor

Similar documents
Pressure Regulator. Instructions for Use

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Pressure Regulators. Instructions for Use

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Dialflow Regulator. Instructions for Use

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Yoke Block Instruction Manual

Oxygen Dialflow Meter. Instructions for Use

Rev. B. Operating Instructions

453 Series Steam Heated Vaporizing Regulator

OPERATION MANUAL NTF-15

Safety instructions and operating manual

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

Propane Conversion Kit Instructions

VAPOMATIC ANESTHETIC VAPORIZER

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

OPERATION MANUAL NTF-60 Plus

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

3/8" Dr. Air Butterfly Impact Wrench

Operating and maintenance manual Filter and reducing station Series / 1.0

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

User manual. ZX trolley.

Compressed Gas Cylinders - Guideline

Oxygen Dialflow Meter. Instructions for Use

WHAT IS GAS TANK/CYLINDER?

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

User Instruction Manual

MODEL NUMBER: AS18-2 USER GUIDE

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

for the of and the EM55-1

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Micro Dial-Flowmeter. Instructions for Use

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Pressure Regulators. Operating Instructions. Instrumentation

Protocol Switchover Station

Instructions for High Altitude Conversion

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Compressed gases. Safety advice.

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

The content of your gas cylinders. Pocket Safety Guide No. 1

AIR/OVER HYDRAULIC JACK 20 TON

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

PURPOSE OF THE POLICY

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Operator: Save these instructions for future use!

Operating Instructions Model and Hydrostatic Test Pump

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

Conversion instructions from natural gas to propane

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Instructions for use Compressed air injector with water trap

Operating manual for Material pressure tanks Vol./1 and Vol./2

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Safe Work Instructions For Oxygen Acetylene Equipment

1.1. Any ASA member who meets the following criteria will be allowed unsupervised access to ASA oxygen system

BRITISH COMPRESSED GASES ASSOCIATION Registered office: 4a Mallard Way, Pride Park, Derby, UK. DE24 8GX Company Number: 71798, England

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Compressed Gas Cylinder Safety

CHAPTER 26 WELDING AND CUTTING

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Yoke Block Instruction Manual

Safe Handling of Pressurized Gases and Cylinders. Dr. Michael Hanisch

Safety, Set-Up, and Operating Instructions

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

8-GAL PNEUMATIC OIL DISPENSER

- GAS REGULATOR - COMPACT STYLE

General Precautions for handling compressed gases

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Risk Management Department. Compressed Gas Safety

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Model: 43T. Bermad Pressure Relief Valve

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Handling and Storage of Gases

Operating manual. LINDOFLAMM Acetylene special burner LF-H series.

Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks

623 Series Dome Load Regulators

Equinox II NITROUS OXIDE / OXYGEN ADMINISTRATION EQUIPMENT 01EQ7000E

MATERIAL SAFETY DATA SHEET. Oxygen, Refrigerated Liquid DOT Hazard Class: 2.2

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

SAFETY DATA SHEET According to Regulation (EC) N 1907/2006

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Universal Charging and Testing Unit FPU-1

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

with O 2 Controller Instruction Manual

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

36H SERIES Combination Gas Valve

LCR-6-WT-EPP CYLINDER ROLLER EXPLOSION PROOF SERIES INSTRUCTION MANUAL MANUAL NUMBER Rev A Issued November 2011

INSTRUCTION MANUAL & PARTS

CSA Sample Draw Aspirator Adapter Operator s Manual

Transcription:

OBJ_DOKU-194490-001.fm Seite 1 Donnerstag, 16. Februar 2017 4:22 16 NOTES ON USE USA APC Pressure Reducer with Sensor 20134-006

OBJ_DOKU-194490-001.fm Seite 2 Donnerstag, 16. Februar 2017 4:22 16 Table of Contents IMPORTANT!.................................... 5 1 Storage and transport............................. 5 2 Intended Use/ Normal Use......................... 6 3 Safety instructions............................... 6 3.1 Using gases and their containers when under high pressure..................................... 6 3.2 Using argon.................................. 7 3.3 Using the pressure reducer...................... 8 4 How to use...................................... 8 4.1 General...................................... 8 4.2 Changing the cylinder.......................... 8 5 Cleaning and disinfection......................... 10 6 Maintenance................................... 10 7 Technical data.................................. 11 2

OBJ_DOKU-194490-001.fm Seite 3 Donnerstag, 16. Februar 2017 4:22 16 Connecting the pressure line and pressure sensor to the APC unit 1. Purge post 2. Pressure line 3. Pressure sensor 3

OBJ_DOKU-194490-001.fm Seite 4 Donnerstag, 16. Februar 2017 4:22 16 Connecting the pressure reducer to the gas cylinder 1. Gas cylinder valve 2. Retainer nut of the pressure reducer 3. Manometer 4. Pressure sensor with connection cable 4

OBJ_DOKU-194490-001.fm Seite 5 Donnerstag, 16. Februar 2017 4:22 16 IMPORTANT! Please read all information carefully. These notes on use do not replace the user manual of the APC unit and Electrosurgical unit used! Read the user manuals of the APC unit and Electrosurgical unit and ask Erbe or your distributor in case of doubt! Caution! Federal law (USA) restricts this device to sale by or on the order of a physician! Please read all information carefully. 1 Storage and transport The corresponding national regulations or international agreements must be observed with regard to transportation. Generally the following is applicable: Gas cylinders may only be transported with a valve guard (e.g. cylinder cap). Cylinder valves must be tightly sealed. Gas cylinders may not be thrown or exposed to impact. Gas cylinders placed in a horizontal position must be wedged in or secured in such a way that they do not roll. Gas cylinders may also be transported upright when appropriate equipment (e.g. pallets) is used. Gas cylinders must be secured during transport in such a way that damage as a result of other items is excluded. 5

OBJ_DOKU-194490-001.fm Seite 6 Donnerstag, 16. Februar 2017 4:22 16 2 Intended Use / Normal Use The argon gas cylinder is intended exclusively for connection to an Erbe APC 2 unit. The APC Pressure Reducer with Sensor 1) is intended exclusively for connection to an argon gas cylinder aimed at supplying argon to the Erbe APC 2. Only argon (Ar) may be used as the working gas. 3 Safety instructions WARNING! 3.1 Using gases and their containers when under high pressure Transport, storage and other activities may only be carried out by qualified personnel and using appropriate equipment! Do not use oil or grease. Protect the gas cylinder against heat generated by radiators or exposed flames. Do not apply force of any kind to gas cylinders, cylinder connectors, pressure reducers or the pressure line. Check the seals of the pressure reducer and the pressure line for damage prior to use. Do not use damaged gas cylinders, cylinder connectors, pressure reducers or pressure lines. Inform your gas supplier or Erbe Elektromedizin without delay. When transporting, storing, or using the gas cylinder, prevent it from falling over or dropping by securing it with chains, hoops, or safety straps. Always use the safety strap of the mobile equipment cart. 1.) Will be designated as pressure reducer in the following text. 6

OBJ_DOKU-194490-001.fm Seite 7 Donnerstag, 16. Februar 2017 4:22 16 Detach the pressure reducer prior to transporting the argon gas cylinder. Argon gas cylinders may only be connected to the APC device using the pressure reducer and pressure lines specified by Erbe! Only use argon gas cylinders that correspond to the respective national safety standards. When opening the gas cylinder valve, there will be a brief hissing sound as a result of the argon flowing into the tubes. If the hissing sound continues for more than 2 seconds after an argon gas cylinder has been opened, there is a leak. Close the gas cylinder valve again immediately. The APC device may only be used when the leak has been rectified. Make sure that the pressure lines are tightly connected to the APC device. The same applies when connecting the pressure reducer to the argon gas cylinder. 3.2 Using argon Argon is heavier than air. If it accumulates in the air that is breathed in, oxygen may be displaced without any obvious indication resulting in a risk of suffocation. Symptoms of oxygen deficiency include drowsiness, rise in blood pressure, and respiratory distress. In an atmosphere of pure argon, a person would fall unconscious immediately without prior warning and suffocate! The APC device may only be operated with argon. It is possible to connect gas cylinders with hazardous contents to the cylinder connectors of the device. For this reason, you must verify whether the gas cylinders do indeed contain argon (i.e. appropriate color code on the argon gas cylinder / cylinder jacket, label with product name). Labels must not be damaged or removed. 7

OBJ_DOKU-194490-001.fm Seite 8 Donnerstag, 16. Februar 2017 4:22 16 3.3 Using the pressure reducer Do not use oil or grease. Never interfere with the screw of the pressure reducer as long as the regulator is under pressure! Gas can escape abruptly or cause the pressure reducer to be ejected in explosive fashion. Never apply pressure to the pressure reducer in the reverse direction (i.e. on the output side), as this can contaminate and damage the APC device. 4 How to use 4.1 General Always open the gas cylinder valve slowly and carefully. Always close the gas cylinder valve after use. Do not use any kind of tool to operate, attach or detach the pressure reducer. Do not smoke in the vicinity of gas cylinders and pressure reducers. 4.2 Changing the cylinder Also observe the illustrations at the start of these instructions. 1. Close the gas cylinder valve! The gas cylinder valve may be a little difficult to turn in some cases. 2. Remove the pressure line (quick coupling) from the connection on the rear of the APC device. 3. The pressure line still contains a residual amount of argon that must be discharged. To do so, place the quick coupling onto the purge post on the rear of the APC device and press against it. The residual argon is now discharged with a loud 8

OBJ_DOKU-194490-001.fm Seite 9 Donnerstag, 16. Februar 2017 4:22 16 hissing sound (check: 0 must be shown on the high pressure manometer). 4. In the counter-clockwise direction: turn and remove the retainer nut of the pressure reducer by hand from the argon gas cylinder (do not use any tools). 5. Change the argon gas cylinder. 6. In the clockwise direction: screw the retainer nut of the pressure reducer by hand on the argon gas cylinder and secure tightly (do not use any tools). Ensure that the O-ring is in appropriate working order and is correctly positioned in the groove of the cylinder connector. WARNING! Check that the pressure reducer is securely positioned on the argon gas cylinder. The pressure reducer should not be loose. 7. Place the pressure line (quick coupling) onto the connection on the rear of the APC device. 8. Connect the pressure sensor at the back of the APC device. 9. Slowly unscrew the gas cylinder valve until it is fully open. Then turn it back again approx. a half-turn. Argon now flows into the lines (a brief hissing sound may be heard) WARNING! If the hissing sound continues for more than 2 seconds, there is a leak. Close the gas cylinder valve again immediately. Check whether the connection of the pressure reducer and the pressure line is in fact leak-tight. The APC device may only be used when the leak has been rectified. 9

OBJ_DOKU-194490-001.fm Seite 10 Donnerstag, 16. Februar 2017 4:22 16 5 Cleaning and disinfection Do not sterilize! The pressure reducer may only be cleaned from the outside. To do so, use a cotton cloth and a medical-grade alcohol solution. All other methods of cleaning are prohibited! WARNING! Flammable and explosive materials must have evaporated fully prior to switching on the APC device and the electrosurgical unit. 6 Maintenance Servicing and repair work may only be performed by competent persons and by persons trained by Erbe. If this work is performed by unqualified persons, Erbe accepts no liability and the warranty is void. Only use original spare parts. The connection cable for the pressure sensor is available separately (art. no. 51709-015). The manufacturer guarantee does not include: Cases involving normal wear or damage incurred during the course of routine maintenance Damage caused as a result of non-observance of the maintenance instructions or as a result of unintended use 10

OBJ_DOKU-194490-001.fm Seite 11 Donnerstag, 16. Februar 2017 4:22 16 7 Technical data Max. inlet pressure / 2900 +435 psi cylinder pressure P 1 Outlet pressure / 72.5 +29/-14.5 psi operating pressure P 2 Gas type Argon 4.8 (99.998 %) Connection standard (output gas cylinder / input pressure regulator) CGA 580 11

OBJ_DOKU-194490-001.fm Seite 12 Donnerstag, 16. Februar 2017 4:22 16 12

OBJ_DOKU-194490-001.fm Seite 13 Donnerstag, 16. Februar 2017 4:22 16

OBJ_DOKU-194490-001.fm Seite 14 Donnerstag, 16. Februar 2017 4:22 16 Manufacturer Erbe Elektromedizin GmbH Waldhörnlestr. 17 72072 Tübingen, Deutschland Tel +49 7071 755 0 Fax +49 7071 755 179 info@erbe-med.com erbe-med.com Distributed by (USA Territory) ERBE USA, Inc. 2225 Northwest Parkway Marietta, GA 30067 Tel (770) 955 4400 Fax (777) 955 2577 sales@erbe-usa.com erbe-usa.com Customer Support 800 778 ERBE (3723) Erbe Elektromedizin GmbH 30134-018 2017-01