Average Volume Assured Pressure Support

Similar documents
Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

BiPAP A30. Set-up guide. Connection to oximetry. Getting started. Guidelines for ventilation set-up. Main screen. Menus.

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

My BiPAP ventilator. My helpful guide

UltraFill meets the d

Amara. When it s right, it just clicks

Liquid with a surprise HomeLox makes and stores liquid oxygen at home

Regain your freedom. The HomeLox portable oxygen system offers the freedom you want

A bench study comparison of volume delivery in the presence of leak

My CoughAssist. A patient guide to CoughAssist T70. Please visit

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

VPAP IV ST POSITIVE AIRWAY PRESSURE DEVICE

INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES

Airox Supportair Ventilator

Flight Medical presents the F60

SenTec OxiVenT Illuminate Ventilation and Oxygenation PCO2 PO2. Digital Transcutaneous Blood Gas Monitoring

Masks and accessories. Home care masks and accessories Technology that cares

Ever. EverFlo. Home oxygen system. Oxygen simplified

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

Mechanical Ventilation

Accumulation of EEV Barotrauma Affect hemodynamic Hypoxemia Hypercapnia Increase WOB Unable to trigger MV

New Frontiers in Anesthesia Ventilation. Brent Dunworth, MSN, CRNA. Anesthesia Ventilation. New Frontiers in. The amount of gas delivered can be

Breathe easier. Patient guide to oxygen therapy

OXYGEN THERAPY. (Non-invasive O2 therapy in patient >8yrs)

The efficacy of a custom-fabricated nasal mask on gas exchange during nasal intermittent positive pressure ventilation

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Mechanical Ventilation

Mechanical Ventilation. Which of the following is true regarding ventilation? Basics of Ventilation

Automatic Transport Ventilator

Mechanical Ventilation. Flow-Triggering. Flow-Triggering. Advanced Concepts. Advanced Concepts in Mechanical Ventilation

BiPAP Vision Ventilator Testing with Various Patient Interfaces Report February 18, 2002

Indications for Mechanical Ventilation. Mechanical Ventilation. Indications for Mechanical Ventilation. Modes. Modes: Volume cycled

The Safe Use and Prescription of Medical Oxygen. Luke Howard

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity

Presentation Overview. Monitoring Strategies for the Mechanically Ventilated Patient. Early Monitoring Strategies. Early Attempts To Monitor WOB

6 th Accredited Advanced Mechanical Ventilation Course for Anesthesiologists. Course Test Results for the accreditation of the acquired knowledge

Vivo Ventilator Manual READ ONLINE

Mechanical Ventilation of the Patient with ARDS

TESTCHEST RESPIRATORY FLIGHT SIMULATOR SIMULATION CENTER MAINZ

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES

Selecting the Ventilator and the Mode. Chapter 6

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

Mechanical Ventilation

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

VENTILATION STRATEGIES FOR THE CRITICALLY UNWELL

Understanding and comparing modes of ventilation

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

D Designed for non-invasive ventilation DRÄGER CARINA

Clinical Skills. Administering Oxygen

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Intensa GO Alternate Care Ventilator

Leak compensation in positive pressure ventilators: a lung model study

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

The Basics of Ventilator Management. Overview. How we breath 3/23/2019

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Introduction to Conventional Ventilation

4/2/2017. Sophisticated Modes of Mechanical Ventilation - When and How to Use Them. Case Study 1. Case Study 1. ph 7.17 PCO 2 55 PO 2 62 HCO 3

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

Using Common Ventilator Graphics to Provide Optimal Ventilation

Neonatal tidal volume targeted ventilation

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Introducing Astral. Greater freedom. Confident care. Designed efficiency

MT Excellent performance and reliability EVITA 4 EDITION

Notes on BIPAP/CPAP. M.Berry Emergency physician St Vincent s Hospital, Sydney

2018 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice.

D Beyond essentials DRÄGER SAVINA 300 SELECT

Author: Thomas Sisson, MD, 2009

3100A Competency Exam

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

This mask changes everything

Supporting your patients every breath

Puritan Bennett 840 Universal Ventilator

Oxylog 3000 plus Emergency & Transport Ventilation

Conflict of Interest Disclosure Robert M Kacmarek

Objectives. Respiratory Failure : Challenging Cases in Mechanical Ventilation. EM Knows Respiratory Failure!

NOTE: If not used, provider must document reason(s) for deferring mechanical ventilation in a patient with an advanced airway

Dräger Savina Sub-Acute Care Ventilation

Patient Setup Information

INTELLiVENT -ASV. The world s first Ventilation Autopilot

SenTec Digital Monitoring System Illuminate Ventilation and Oxygenation in Neonatology PCO2 PO2

Initiation and Management of Airway Pressure Release Ventilation (APRV)

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

Focused on essentials DRÄGER SAVINA 300

excellence in care Procedure Management of patients with difficult oxygenation. For Review Aug 2015

RESPIRATORY CARE POLICY AND PROCEDURE MANUAL. a) Persistent hypoxemia despite improved ventilatory pattern and elevated Fl02

Lung recruitment maneuvers

Potential Conflicts of Interest Received research grants from Hamilton, Covidien, Drager, General lel Electric, Newport, and Cardinal Medical Received

NAVA Neurally Adjusted Ventilatory Assist In Neonates

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine

Now you re ready. Philips HeartStart AED Services

VENTILATORS PURPOSE OBJECTIVES

Difficult Oxygenation Distribution: Sydney X Illawarra X Orange X

Helpful hints for filing

A Bench Study of the Effects of Leak on Ventilator Performance During Noninvasive Ventilation

Astral in AirView: Improving patient care through connectivity. ResMed.com

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

evolution 3e Ventilators

Transcription:

Ventilation Average Volume Assured Pressure Support

How to reach us www.philips.com/healthcare healthcare@philips.com Asia +49 7031 463 2254 Europe, Middle East, Africa +49 7031 463 2254 Latin America +55 11 2125 0744 North America +1 425 487 7000 800 285 5585 (toll free, US only) Philips Respironics 1010 Murry Ridge Lane Murrysville, PA 15668 USA Customer Service +1 724 387 4000 Philips Respironics Asia Pacific +65 6882 5282 Philips Respironics Australia +61 (2) 9947 0440 1300 766 488 (toll free, Australia only) Philips Respironics Deutschland +49 8152 93 06 0 Philips Respironics France +33 2 51 89 36 00 Philips Respironics Italy +39 039 203 1 Philips Respironics Sweden +46 8 120 45 900 Philips Respironics Switzerland +41 6 27 45 17 50 Philips Respironics United Kingdom +44 800 1300 845 www.philips.com/respironics 2015 Koninklijke Philips N.V. All rights are reserved. Philips Respironics, Synchrony, BiPAP, Auto-TRAK are trademarks of Koninklijke Philips N.V. and its affiliates. All rights are reserved. Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Broudy RP 5/22/15 MCI 4106558 PN 1081265

Clinical reference Auto-TRAK algorithm Performance Characteristics of 10 Home Mechanical Ventilators in Pressure-Support Mode Chest 2005, Battisti et al Noninvasive Ventilator Triggering in Chronic Obstructive Pulmonary Disease AJRCCM 2001, Stell et al Performance Characteristics of Bilevel Pressure Ventilators Chest 1997, Bunburaphong et al AVAPS support function Average volume assured pressure support in obesity hypoventilation: a randomized cross-over trial Chest 2006, Storre et al Volume targeted versus pressure support non-invasive ventilation in patients with super obesity and chronic respiratory failure: a randomised controlled trial Thorax 2012, Patrick Brian Murphy et al AVAPS, a unique clinically proven technology For patients with Obesity Hypoventilation Syndrome The addition of AVAPS to BPV-S/T provides beneficial physiologic improvements, resulting in a more efficient decrease of PtcCO 2 compared to BPV-S/T therapy alone. Average Volume Assured Pressure Support in Obesity Hypoventilation: a Randomized Cross-Over Trial. Storre, et al. Chest 2006. For patients with chest deformities After switching to BiPAP-AVAPS therapy, the results included an increase in average oxygen saturation, a reduction of pco 2 levels and an improved acceptance of therapy compared to previously used ventilation methods. Average Volume Assured Pressure Support (AVAPS) for Pressure-Controlled Ventilation (BiPAP Therapy). Kerl, et al. Poster presented at the German National Home Mechanical Congress, 2004. For patients with hypercapnic COPD AVAPS mask ventilation has similar efficacy and produces better subjective effects on sleep as compared with PS in COPD patients with chronic hypercapnia. A pilot study on efficacy of nocturnal AVAPS mask ventilation in patients with hypercapnic COPD. Crisafulli, et al. Poster presented at the ATS congress, 2008.

Estimation of the exhaled tidal volume (Vte) Original baseline Flow adjusted for additional leak New baseline Digital Auto-TRAK algorithm combined with the BiPAP system is able to quickly identify the leak by comparing the original baseline flow to the new baseline flow. Differences are recognized as leaks, and adjusted for, quickly. Auto-TRAK algorithm estimates patient flow to provide: Automatic triggers: sensitivity remains optimal even with a change in leaks and patient s respiratory mechanics An estimation of exhaled patient tidal volume (Vte) for ventilation monitoring and for AVAPS. Based on Auto-TRAK advanced technology, AVAPS ensures a close monitoring of Vte and adjusts IPAP to maintain a true averaged patient tidal volume. The right pressure at the right time for more patient comfort and more efficient ventilation.

AVAPS suggested settings AVAPS Settings 1. Set the Target Tidal Volume: To 8ml/kg of the ideal weight and adjust depending on patient pathology 2. Set IPAP Limits: and IPAP max = 25 to 50 cmh 2 O depending on patient condition and maximum pressure available on the machine IPAP min = EPAP + 4 cmh 2 O depending on patient condition Check patient arterial blood gases (PaCO 2 and PaO 2 ) and oxygen saturation (SpO 2 ) * Conversion table to set the target tidal volume in relation to the ideal weight: Height Calculated ideal Target Vte Target Vte weight (if BMI = 23) if 8 ml/kg if 10 ml/kg 1.50 m 52.0 kg 410 ml 520 ml 1.55 m 55.0 kg 440 ml 550 ml 1.60 m 59.0 kg 470 ml 590 ml 1.65 m 62.5 kg 500 ml 620 ml 1.70 m 66.5 kg 530 ml 660 ml 1.75 m 70.5 kg 560 ml 700 ml 1.80 m 74.5 kg 600 ml 740 ml 1.85 m 78.5 kg 630 ml 780 ml 1.90 m 83.0 kg 660 ml 830 ml Above data have been calculated with an ideal Body Mass Index of 23 kg/m 2 (BMI=weight/height 2 ) Die obigen Daten wurden auf Basis eines idealen Body-Mass-Index von 23 kg/m 2 (BMI = Gewicht/Größe 2 ) berechnet.

What is AVAPS? Average volume assured pressure support (AVAPS) is a support function that can be activated within our S, S/T, PC and T pressure modes. It automatically adapts pressure support to patient needs to guarantee an average tidal volume. Based on the auto-trak algorithm IPAP max. performance, the patient s tidal volume is estimated at each breath IPAP and compared with the target tidal IPAP min. volume. Inspiratory pressure increases or decreases from breath to breath to ensure the preset tidal volume. Target volume Inspiratory pressure smoothly Patient changes (<1 cmh 2 O/min) so as not to volume affect patient comfort, and to prevent any potential patient- ventilator disynchronization. In case the patient tidal volume is far from the set target Vt, an accelarating factor will allow the inspiratory pressure to change faster by up to 3 cmh 2 O/min. Which patients? Obese hypoventilation patients: To compensate for changes in body position; averaged tidal volume ensured COPD patients: To achieve a combination of ventilation comfort and efficiency with no compromise. Get both benefits by applying the right pressure at the right time. Restrictive patients: To provide the comfort and leak compensation of a pressure mode, and the safety of a guaranteed volume Which benefits? Make titration process easier, no IPAP adjustment needed Follow disease progression as patient s ventilatory needs change Improve patient s ventilation efficacy and comfort Increase safety by guaranteeing an averaged tidal volume