Pressure switch Type BCP

Similar documents
Pressure controls, differential pressure controls type RT

Pressure switch KP-E. Data sheet

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure switch and Thermostat CAS

Pneumatic pressure switch 20DD

Pressure switch, Differential pressure switch and Thermostat RT-E

Pressure switch and Thermostat KPS

Pressure switch and Thermostat Type KPS

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential pressure controls, Type MP 54, 55 and 55A

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Data sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782

Pressure switches and thermostats, type KPS

Pressure control, differental pressure control and thermostat Type RT

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Types and approvals. Page 1/6. Data Sheet

DSL, DSH: Specially designed pressure limiter

Pressure switch RT. Data sheet

Model range*1) Switching pressure difference

Differential pressure switch MP 54, MP 55 and MP 55A

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Tightness controls TC 1 3 and TC 4

Automatic Valve Proving Control

Pressure switch for gas and air

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et

Pressure Switch for gas and air

) for different types of systems Test of contact function The correct pressure control for your system

Pressure Switches Application Guideline

Evaporator pressure regulator Type KVP

Gas Pressure Switch for DMV safety shutoff valves

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Gas Pressure Switch for DMV safety shutoff valves

Pressure Switch for gas and air

Inverse Prop. Pressure-Relief Cart., Size 2 4

DSB, DSF: Pressure monitors and pressure switches

Pressure Switch for gas and air GGAO-A4

Gas Pressure Switch for DMV safety shutoff valves

Pressure switches for air and water CS

Evaporator pressure regulator Type KVP

Mechanical pressure switches Tested to PE Directive 97/23/EC

[Instruments for vacuum measurement, checking and adjustment] 3

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Product Catalogue MINICOMB. Switches for Pressure and Vacuum

PROVENGAS AUTOMATIC PROVING SYSTEMS FOR GAS INSTALLATION

Miniature controls. Contactors. Overload relays. Starters. Control relays

System Pressure Manager Standard & System Pressure Manager Plus

Inverse Proportional Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Pressure Switch Pressure Limiter

Electromechanical pressure switches

SPECIFICATIONS ATTENTION

Mechanical pressure switches Tested to PE Directive 97/23/EC

BUBBLER CONTROL SYSTEM

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Gas Pressure Regulator HON 300

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Circuit breakers PR 60

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

DSB, DSF: Pressure monitors and pressure switches

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Installation and Operation Manual

CALEFFI. Ball zone valves. series /03 GB

Mechanical pressure switches Tested to PE Directive 97/23/EC. Maximum pressure limiters for liquid gas installations

Tested to PE Directive 97/23 EC

EPP4 Pressure Regulator Basic G 1/4"

Instruction Manual Contact Pressure Vacuum Gauge

Prewired position switches FA series

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

4/2 way Pneumatic Solenoid Valve

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Accessories for Progressive Systems

Installation, operating and maintenance Instructions for Seemag bypass level indicator

C645A-E Pressure Switches

AutoChanger Installation & User Guide Issue 2

Autocalibration Systems For In Situ Oxygen Analyzers

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure transmitters EMP 2

Introduction. Description. Series P48 Pressure Controls for Steam, Air or (hot) Water. Feature and Benefits

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

VLT 2000 Series. How to size your VLT

TeSys protection components

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Gas Pressure Regulator HON 200

Powers Controls D Day-Night Thermostats

Valve Proving System VDK 200 A S02

HBLT-A1 LIQUID LEVEL SENSOR

Valve Proving System VDK 200 A S06*

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Transcription:

Data sheet Pressure switch Type BCP The BCP type is a series of dedicated switches for safety and monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where the contact position depends on the in the connection port and the range set value. For installations, in which operation is particularly critical for safety reason, the use of fail-safe control is recommended. Features y Available as high and low limiters as well as controllers y Wide range: from low BCP1 with narrow differential to high BCP7 y The fail-safe dual bellows enable premature cut-out when fault occurs y DIN plug mounted on the top of control for easy electrical wiring y Single-pole changeover switch (SPDT), switch + alarm y Direct mounting on connection or wall mounting by means of a bracket y Versions with automatic and manual resets available y Screw adjustments made on top of housing y Manual reset for limiters possible only by means of tools y Safety Integrity Level: SIL 2 according to IEC 61508:2010 Approvals CE-marked in accordance with EN 60947-4/-5 VdTŰV-Merkblatt Druck 100 TŰV. SDWFS/SDBFS. 15-335 CE marked in accordance with PED 97/23/ED, category IV, safety equipment, testing basis pr EN12952-11 and EN12953-9. DCS (jmn) 2016.07 IC.PD.P10.M9.02 520B6305 1

Materials in contact with media Bellows: stainless steel X2CrNi19-11, 1.4306 acc. to EN 10088-2 Pressure connection: nickel plated free cutting steel or stainless steel X5CrNi18-10, 1.4301 acc. to EN 10088-2 Technical data Media Steam, water, air Ambient temperature -20 70 C Media temperature Enclosure Action type acc. to EN 60730 Up to 120 C (Above 120 C a water-filled loop must be installed). IP65 Type BCP - 2B Types BCPL/BCPH - 2BDF Electrical connection Plug DIN 43650, Pg 11 Switch type Contact material SPDT, snap action microswitch Silver/gold (gold plated silver) Contact load Minimum Maximum 1 ) 1mA, 5V 2 ) AC-1: 6A, 250V 3 ) AC-15: 1A, 250 V 4 ) DC 13 10W, 250 V Expected electrical lifetime Min. 250 000 cycles under full contact load. 1 ) If used with current higher than 100mA and voltage higher than 30V the gold layer will be burnt away and the unit can t be used at a lower current again. 2 ) AC-1 Ohmic load, cosφ 1. 3 ) AC-15 inductive load like coil and contactors with, cosφ 0.3. 4) DC-13 Direct current load. Ordering High limiters Fixed Max. Max. operating test Pressure Type Range avg. Code no. connection BCP1H 0.1 1.1 0.10 Man. 6 7 G 1 2 A 017B0030 BCP2H 0.0 2.5 0.20 Man. 10 11 G 1 2 A 017B0034 BCP3H 0.0 6.0 0.40 Man. 16 18 G 1 2 A 017B0038 BCP3H 0.0 6.0 0.40 Man. 16 18 G 1 2 A 017B0138 1 ) BCP4H 1.0 10.0 0.45 Man. 25 28 G 1 2 A 017B0042 BCP5H 2.0 16.0 1.20 Man. 32 35 G 1 2 A 017B0046 BCP6H 5.0 25.0 1.50 Man. 40 45 G 1 2 A 017B0050 BCP7H 10.0 40.0 2.30 Man. 63 70 G 1 2 A 017B0054 Low limiters Fixed Max. Max. operating test Pressure Type Range avg. Code no. connection BCP2L 0.0 2.5 0.20 Man. 10 11 G 1 2 A 017B0058 BCP3L 0.0 6.0 0.40 Man. 16 18 G 1 2 A 017B0062 BCP4L 1.0 10.0 0.45 Man. 25 28 G 1 2 A 017B0066 BCP5L 2.0 16.0 1.20 Man. 32 35 G 1 2 A 017B0070 BCP6L 5.0 25.0 1.20 Man. 40 45 G 1 2 A 017B0074 DCS (jmn) 2016.07 IC.PD.P10.M9.02 520B6305 2

Ordering Pressure controllers Type Range avg. Max. operating Max. test Pressure connection Code no. BCP1 0.1 1.1 0.15 0.6 Auto 6 7 G 1 2 A 017B0002 BCP2 0.0 2.5 0.4 1.0 Auto 10 11 G 1 2 A 017B0006 BCP3 0.0 6.0 0.7 1.4 Auto 16 18 G 1 2 A 017B0010 BCP3 0.0 6.0 0.7 1.4 Auto 16 18 G 1 2 A 017B0110 1 ) BCP4 1.0 10.0 1.0 2.5 Auto 25 28 G 1 2 A 017B0014 BCP5 2.0 16.0 2.0 3.2 Auto 32 35 G 1 2 A 017B0018 BCP6 5.0 25.0 2.5 4.0 Auto 40 45 G 1 2 A 017B0022 BCP7 10.0 40.0 3.0 6.0 Auto 63 70 G 1 2 A 017B0026 1 ) Stainless steel connector DCS (jmn) 2016.07 IC.PD.P10.M9.02 520B6305 3

Design and function Pressure switch, type BCP Version with automatic reset cut-in again automatically when the falls to the set point minus differential. Version with manual reset has to be cut in manually by means of tool. 1. Main spindle 2. Main spring 3. spindle 4. spring 5. spring 6. Activating arm 7. Bellows 8. Pressure connection 9. push button 10. knob 11. DIN plug 12. Microswitch 13. Michroswitch bracket 14. Range knob 17-893.11 Fail-safe bellows concept BCP 6, BCP 6H, BCP 7, and BCP 7H have a double bellows: an operating bellows (inner) and safety bellows (outer). 3 2 1 1. Pressure connection 2. Regulating bellows 3. Safety bellows 17-894.11 Microswitch BCP is a microswitch based control with DIN plug. Such design enables easy electrical connection and makes control suitable for operation with modern electronic systems, as PLC. Silver/gold plated contacts Silver/gold plated contacts are used for low currents and middle range of current, especially in applications with PLC or other corresponding electronic devices. Such contacts have also significantly lower emission of electromagnetic noises produced on contact break. EMC (Electro Magnetic Compatibility) is an important parameter where electronic equipment is used. A gold plated contact has a silver layer under the gold and can therefore also be used in the middle range of load. The gold will disappear at loads above 0,1 A. Ambient temperature influence All BCP switches operate independently of changes in ambient temperature around the switch. Therefore the settings for cut-out and differential stay constant unless the permissible ambient temperature is exceeded. When system exceeds the set value, the BCP will automatically stop the plant. A rupture in the inner bellows cause the control cut-out to fall about 3 times less then the preset value, thus the system stops prematurely. A rupture in the outer bellows cause the control cut-out to fall about 3 bar under the preset value, thus providing a fail-safe function. In other BCP types with single bellows assembly, fail-safe function is satisfied by proved 2 millions cycles mechanical life time test. DCS (jmn) 2016.07 IC.PD.P10.M9.02 520B6305 4

Setting Cut-in and cut-out s of the system should always be checked with accurate gauges. Pressure settings for switches (with automatic reset) Set the cut-out on RANGE scale and differential on DIFF. scale. Restart is equal to cut-out minus pre-set differential value. Pressure switches with manual reset High limiters Set cut-out on the RANGE scale. Pressure limiter can only be manually reset by pressing reset button by means of tools when the is equal to or below the cut-out minus value of the differential. Low limiters Set cut-out on RANGE scale. Limiter can only be reset manually by pressing (with tool) the reset button when rises to cut-out plus differential or above it. Pressure limiters have no differential scale. Fixed differential value is printed on the scale plate. Terminology Pressure limiters Limiters are devices that, on reaching a fixed value interrupt and lock out the energy supply. Manual unlocking is required before restart. A limiter shall be such that a single fault in any related part shall not lead to a loss of the safety function. If a BCP controller with automatic reset is used as limiter, lockout must be realized externally as a part of safety logic, e.g.: by external contactors and/ or relays according to requirements of standard pren501156-1 for safety relevant hardware. External closure must be interlocked, while loss of auxiliary energy must lead to closure. ting must not be automated; it has to be performed manually. ting on fault must lead to a repeated closure. When BCP limits, is for rising or falling applications, the external safety logic must change to fail-safe position. Fail-safe control A control is fail-safe if it has the capability to remain in a safe condition or transition to a safe condition when a fault occurs. If the system exceeds PS/MWP then accuracy of the control settings can be lost. Maximum test The maximum applied in strength or leakage tests on heating systems or components thereof. Maximum working The maximum permissible for safe functioning of the system or any of its components. Snap function A specific contact force is maintained in micro-switch until snap is initiated, therefore, contact bounce cannot occur as a result, for example, of slight vibrations before cut-out. These design features ensure that the cut-out point of the BCP control remains very accurate and completely independent of the magnitude of the current load. Set point A predetermined value to which a control is adjusted and at which it performs its intended function. The difference between cut-out and cut-in. 1. Manual reset A unit with manual reset can only be restored to operational mode by activation of the external reset button. 2. Automatic reset A unit with automatic reset is restored to operational mode automatically DCS (jmn) 2016.07 IC.PD.P10.M9.02 520B6305 5

Installation in steam systems To protect the element against excessive temperature of the media, above allowable 120 C the insertion of waterfilled loop is recommended. Dimensions [mm] and weights [kg] BCP types except for BCP 1 and BCP 1H Types BCP 1 and BCP1H Net weight: 0.5 kg DCS (jmn) 2016.07 IC.PD.P10.M9.02 520B6305 6

Accessories for BCP switches Mounting bracket, code number 017B1018, for direct mountng on the wall Mounting bracket for T 35 mm rail, code number 017B1019 For 35mm rail 17-901.11 4xø5.5 17-900.11 For 35mm rail Mounting of BCP on the 35 mm rail can accept no responsibility for possible errors in catalogues, brochures and other printed material. reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. and the logotype are trademarks of A/S. All rights reserved. DCS (jmn) 2016.07 IC.PD.P10.M9.02 520B6305 7