BGI, INC. WALTHAM, MA 02451

Similar documents
Blaustein Atomizer (BLAM) Multi-jet Model. User s Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Model ASSEMBLY and OPERATING INSTRUCTIONS

Hygienic Bubble Trap Installation and Operations Manual

ROPV R40 E Series User Manual

Sterile Visual Flow Indicator

EQUIPMENT Operation Manual. Loctite Stainless Steel Poppet Valve Part Number

Instruction Manual Updated 7/26/2011 Ver. 2.2

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

Instructions for use Compressed air injector with water trap

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

-VERITAS- High Volume Field Audit Calibrator Dual Range Model HVC2 1.4 to 7 and 7 to 54 CFM. NIST Traceable ISO 9001:2008

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

Circular Sight Windows

Yoke Block Instruction Manual

600 o F High Temperature Aging Cell Instruction Manual

Instruction Manual Model Borehole Pressure Cell

Parts Manual. Frusheez Machines

Flexi-pro Aerosol Delivery System (FADS) Manual

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

92831 TEL: (714) FAX:

Installation, Operation and Maintenance Manual

High Temperature Aging Cell Instruction Manual. Manual No , Revision F

S&S. Installation Instructions: S&S Stealth Air Cleaner Kit for Harley-Davidison Models With Stock Cable Operated Delphi EFI

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Pressure Injection Cell Operator s Manual

Yoke Block Instruction Manual

IMPORTANT: RECEIVING INSTRUCTIONS:

EVO Solid Downtube. Operators Manual for Downtubes fitted with zinc plated springs June 2004

User s Guide. Vacuum Controller for liquid delivery systems

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

ROUND ASSEMBLY. Positioning

COMPACT METAL bender 99826

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Geotech 1.66 Reclaimer

Gas and Vacuum Tubing Connection Kit for Manual Operation, No

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

ST 18 Aluminium Gas Model

FLOW CONTROL & AIR PILOT SWITCH VALVES

SC HYDRAULIC ENGINEERING CORPORATION

TECHNICAL TRAINING SS1

Pressure Dump Valve Service Kit for Series 3000 Units

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

Atmospheric relief valve type 1100 Installation and maintenance instructions

Hydraulic Live Swivels

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Pressure Dump Valve Service Kit for Series 2300 Units

Model No Product Name Handpiece Only Complete System

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

PENBERTHY MULTIVIEW MAGNETIC LIQUID LEVEL METERS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

1700ESL Kamvalok Coupler

Unisense In Situ UniAmp Connector System

Paintball Marker. User s Manual. Direct Feed. SC: Stock Class. VSC: Vertical Air Stock Class. 530 South Springbrook Road Newberg, OR 97132

Sunset Swings By Health in Motion, LLC

ST 18 Aluminium Gas Model

User Manual. ECC-Opto-Gas. Release Electrochemical test cell EL-CELL GmbH

INSTRUCTIONS PARTS LIST

CSA Sample Draw Aspirator Adapter Operator s Manual

RGC-IR Remote Gas Calibrator for IR400

Alkylphosphines. Storage and Handling Recommendations

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Budget Range Operators Handbook

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

PRESSURISED PAINT CONTAINER

Headset I nstallation I nstructions Published Jul, ZS074.v3 Full Speed Ahead

Installation and Operating Instructions

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Cocoa Patio Pond with Lit Spillway

Instruction Manual Updated 5/26/2009 Ver. 2.0

T1-Titanium HVLP Siphon Feed Spray Gun

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

DAKOTA 2006 DUMP BOX ILLUSTRATED PARTS MANUAL

Tsunami Breathable Air System

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

CF-SERIES HIGH FLOW REGULATORS

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Service and Repair Manual

92831 TEL: (714) FAX:

Float Operated Level Controllers

Pressure Relief Valve Instruction Manual

Transcription:

BGI, INC. WALTHAM, MA 02451 JANUARY, 2002 58 Guinan Street Waltham, MA 02451 Tel: 781-891-9380 Fax: 781-891-8151 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - COLLISON NEBULIZER INSTRUCTIONS MRE 1, 3, 6 and 24 Jet 1. Introduction The Collison Nebulizer was first described in the scientific literature by Collison in 1935, according to May (1). Over the intervening years, it has become the recognized technique for atomizing liquids and suspensions. The original version had 3 jets and BGI is responsible for the standardization and publication of the 6 jet version (2). Nebulization is taken to mean a refinement of two fluid atomization. In an atomizer, a gas is used to aspirate the liquid into a (usually) sonic velocity gas jet, wherein it is sheared into droplets. In a Nebulizer, this liquid/gas jet is impacted against a barrier (the inside of the jar) to remove the larger fraction of the droplets. There is one basic type of Collison Nebulizer, known as the modified MRE, which is manufactured by BGI. MRE stands for Microbiological Research Establishment, located in Porton, England. All Collison Nebulizers of current BGI manufacture, have all the metal components fabricated from 316 stainless steel. All O rings are buna N or silicone rubber. No flat gaskets are currently utilized. Glass jars are either Crown Glass (standard) or Pyrex (precious fluids jar only). The 24 jet Collison jar is coated with clear PVC. 2. Safety Precautions While the recommended pressure to be applied to the nebulizer may vary from 20 to 100 psig., it must be clearly understood that this pressure is expanded to just above atmospheric, inside the jar. The glass jar is not to be subjected to pressures above 1 psig under any circumstances! Great care must be exercised at all times when connecting the nebulizer s output to other apparatus, to ensure that the flow of gas out of the nebulizer is not restricted in any manner that will cause significant back pressure. The Collison Nebulizer is intended to be utilized by trained scientific professionals. BGI will bear no responsibility for misuse. 3.0 Set up 3.1 Air. It is the responsibility of the investigator to supply a source of clean, compressed air. The volumetric requirements as follows: Pressure psig Volume of Free Air in LPM 1-Jet 3-Jet 6-Jet 24-Jet 20 2 6 12 48 40 3.3 10 20 80 60 4.5 13.5 27 Not Recommended 80 5.8 17.3 34.5 Not Recommended 100 7 21 42 Not Recommended

It is recommended that a precision pressure gage be fitted to the plugged end of the T. This may be accomplished by removing the plug screw by hand. A schematic diagram of the basic set up is shown in figure 1. All parts are shown in Figure 2. 3.2 Liquid Level No specific liquid level is recommended. This is because the T may be pulled up or pressed down to a variety of positions. The important point is to begin with the tip of the nozzle immersed no more than 3/8 of an inch below the surface. Deeper immersion will cause the surface of the liquid to interfere with the formation of the jet. For clarification of this point see Figure 3. 3.3 Cleaning Basic cleaning functions can be performed by disconnecting the apparatus from the air hose and removing and emptying the jar. All components can then be immersed in a cleaning solution appropriate to the material being aerosolized. Ultrasonic cleaning is highly recommended. The nozzle may be removed from the T stem by hand (since 1996). A small, custom made, O ring is fitted to the stem, in a groove above the threads, to seal the juncture. If an internal jet becomes plugged, it may be cleared with the clean out drill (CN-11) supplied with all new units. 4.0 Precious Fluids Jar This is a fabricated pyrex jar, which has a 5 ml well formed into the bottom. It may be used as a replacement for the standard jar. However, it must be utilized in conjunction with the extension sleeve (CN-41) to the bottom of the nozzle. the purpose of the sleeve is to permit the nozzle to operate in a position sufficiently elevated such that the spray does not interact with the bottom of the jar. Its application is best illustrated by viewing Figure 4. The sleeve is slotted to permit bending the tabs thus formed, inwards for the purpose of achieving a firm fit between the sleeve and the nozzle. 5.0 External Fill Adaptor The purpose of the external fill adaptor is to permit the addition of liquid while the Collison is running. Replacement liquid can not simply be poured into the jar through a fill hole because there is a slight pressure inside the jar and pouring liquid past he jets may cause unaccountable difficulties with the aerosol production. The external fill adaptor (CN-42) comprises a luer bulkhead adaptor and cap fitted with a long section of thin tubing. All current production lids have a threaded hole fitted with a plug screw. All current production nozzles have an extra (2 nd, 4 th or 7 th ) hole to guide the thin tube into the nozzle. Each CN-42 is supplied with an O ring and lock nut. The application of this device is illustrated in Figure 5. 6.0 Further Information The best cookbook reference of the application of the Collision Nebulizer is and remains the one by May (1). Because of the universal acceptance and use of this device, references in aerosol-related literature are constantly occurring and should be consulted when appropriate or necessary. The 24 Jet Collison is a recent development, not presently described in the literature. It is not intended for external fill nor precious fluid applications.

7.0 Component Parts List Fig. 2 1, 3 and 6 Jet CN 24/1J Jet (1) CN 24 J Jet (3) CN 48 T Stem CN 25 J Jet (6) CN 49 O Ring CN 27 Bottle CN 50 Compression Nut CN 40 Precious Fluids Bottle CN 51 Conical Ferrule - TFE CN 39 O Ring - Silicone CN 52 Ferrule, Flat-SS CN 43 Plug Screw CN 53 Lid CN 44 O Ring CN 54 O Ring CN 47 Nut 24 Jet Only those parts unique to the 24 jet model, CN-60 are listed below (see figure 6). Other components are common with the 3 and 6 jet models. CN 61 O Ring - Lid CN 65 Lid CN 62 O Ring Body CN 66 Body Cover CN 63 Jar CN67 Jet Body CN 64 T Stem 8.0 Disclaimer The Collision Nebulizer is subject to all the terms of BGI Incorporated standard limited warranty. The nebulizer is a specialized article of research equipment intended for use by trained professionals. No liability is accepted by BGI Incorporated on account of misuse, misapplication or mishandling. BGI Incorporated specifically does not condone nor endorse any application or use which involves restricting emissions from the device and thus causing pressurizing of the jar. Further, BGI Incorporated accepts no liability for exposure to toxic, infectious or harmful substances resulting from the use of this apparatus. Limited Warranty BGI Incorporated warrants equipment of its manufacture and bearing its nameplate to be free from defects in workmanship and material. We make no warranty, express or implied, except as set forth herein. BGI s liability under this warranty extends for a period of one (1) year from the date of BGI s shipment. It is expressly limited to repairing or replacing at the factory during this period and at BGI s option, any device or part which shall within one year of delivery to the original purchaser, be returned to the factory, transportation prepaid and which on examination shall in fact be proved defecting. BGI assumes no liability for consequential damages of any kind. The purchaser, by acceptance of this equipment, shall assume all liability for consequences of its misuse by the purchaser, his employees or others. This warranty will be void if the equipment is not handled, installed, or operated in accordance with our instructions. If damage occurs during transportation to the purchaser, BGI must be notified immediately upon arrival of the equipment. The Equipment will be returned via collect shipment. A defective part in the meaning of this warranty shall not, when such part is capable of being repaired or replaced, constitute a reason for considering the complete equipment defective. Acknowledgment and approval must be received from BGI prior to returning parts or equipment for credit. No representative of ours has authority to change or modify this warranty in any respect. References: 1. May K.R. (1973) The Collison Nebulizer. Description, Performance & Application J. of Aerosol Science, Vol. 4, #3, P. 235. 2. Gussman, R.A. (1984) Note on the Particle Size Output of Collison Nebulizers, Am. Ind. Hyg. Assoc. J. (45).

Figure 1. Schematic Diagram of Collison Nebulizer

Figure 2. Exploded View of Collison Nebulizer

Figure 3. Submersion Depth of Nozzle Tip

Figure 4. View of Correct Installation of Precious Fluid Sleeve in Precious Fluid Jar

1743 Figure 5. Installation of External Fill Adapter

Figure 6. Exploded View of 24 Jet Collison