Instructions for Use. advanced air AF-100

Similar documents
Instructions for Use. Electric Motor MF-100

Restoration & Prosthetics. We ve harnessed air. NEW. Constant removal rate without loss of speed.

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

SC505 Sof Care Inflator. Operating Instructions and Service Manual

User Manual PTW-DensiX. D / Di/Zi

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Digital Melting Point Apparatus

Pressure Automated Calibration Equipment

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

Instrument Description and Operating Instructions OXYMAT 2. Its own oxygen source

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Paradise Pump Series Operator s Manual

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

PROCESS ANALYSERS. SERVOPRO PureGas. Gas Purifier. Operator Manual. Part Number: A Revision: 0 Language: UK English

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Pressure Regulator. Instructions for Use

Instructions for use Compressed air injector with water trap

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Operating Manual VSA100A. tina29e1 ( )

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Oxygen Dialflow Meter. Instructions for Use

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Ritter AquaBottleSystem

The Univentor 1250 Anaesthesia Unit

USER MANUAL. JET TST and JET TST S.

DECLARATION OF CE CONFORMITY DECLARATION OF CE CONFORMITY

Instructions for use INTRA LUX motor K REF INTRA LUX motor K 200 F - REF

Med Aire Alternating Pressure Pump and Pad System

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Operating Instructions. ATMOS Chair Comfort. English GA1GB Index 01

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

453 Series Steam Heated Vaporizing Regulator

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Pressure Regulators. Instructions for Use

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

KMW3000C. User Manual. Water Chiller for Xcalibur and Gemini systems. Version 1.6, September 2010

Digital Inflation Equipment

STAGE, STADIUM & X-TREME SHOT.

SkillGuide. User Guide. English

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Oxygen Dialflow Meter. Instructions for Use

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Regalia Oxygen Concentrator

Instruction Manual for Configura Cushionair Portable Pump

Instruction Manual BA90 Precision Barometer

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Dual Solenoid Gas Valve Installation

Siphon vessel / Priming aid

INSTRUCTION MANUAL & PARTS BREAKDOWN

200 PSI FAST-FILL AIR SOURCE KIT

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Mark 5 Nuvo(OCSI) Lite

Operating Instructions

Model No Product Name Handpiece Only Complete System

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

Digital Inflation Equipment 89XDA 89XDD 89XDB 89XDE.

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

KERN EG/EW Version /02

444C DUAL PERFORMANCE VALUE PACK

200 PSI COMPRESSORS - MODEL NUMBERS

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATION INSTRUCTIONS

Operating Instructions in accordance with the Machines Directive 2006/42/EC

LC-SPE. Organizer 3.0 User Manual. Innovation with Integrity. Version 001 NMR

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

A17W49_MASEM_F_EN MANUAL

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

100C Air Compressor Kit

Dialflow Regulator. Instructions for Use

Operating Instructions

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

30000 Series Treatment Tables

Control units. Installation and operating instructions Series: DP-Control

Getting to know your Sureshotgps micro V3

DYNAMIC COMPRESSION THERAPY

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Instructions for Cleaning & Maintaining Air Compressor

OPERATOR s MANUAL AHCON PCI 3000

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Digital Inflation Equipment 89XDZ 89XDX. Please read this manual before carrying out any installation or service procedures.

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Micro Dial-Flowmeter. Instructions for Use

Gas plug-in hose, straight-through form. Instructions for Use. suitable for gas socket model G2019T, G2016T. G2023 from 01/1990.

Transcription:

Instructions for Use advanced air AF-100

Contents Symbols... 3 5 1. Introduction...6 7 2. Electromagnetic compatibility (EMC)...8 3. Unpacking...9 4. Scope of delivery...10 5. Safety notes...11 13 6. Guide to display...14 7. Installing the support...15 8. How to remove the display Installing the display / display holding...16 9. Overview of the rear...17 10. Start-up General...18 20 11. Factory settings / keys...21 12. Operation Changing / saving the speed and mode...22 13. Operation General set-up menu...23 14. Operation Back to original program...24 15. Reset factory settings...24 16. Operation Set-up menu...25 17. Deactivate standby mode...26 18. Active resuction stop...26 19. Error messages...27 20. Functionality test Primea Advanced Air turbine handpiece...28 21. Operation standard turbine...29 22. Hygiene and maintenance... 30 31 23. W&H accessories...32 24. Service...33 25. Technical data...34 26. Disposal...35 Explanation of warranty terms...36 Authorised W&H service partners... 37 2

Symbols in the Instructions for use WARNING! (risk of injury) ATTENTION! (in cases where something could be damaged) General explanations, without risk to persons or property Call customer service 3

Symbols on the medical device Consult instructions for use Catalogue number DataMatrix code Follow instructions for use Serial number V Supply voltage of the medical device Date of manufacture Do not dispose of with domestic waste Type B applied part (not suitable for intracardiac application) Medical General medical equipment with respect to electrical shock, fire and mechanical hazards only in accordance with UL 60601-1:2006, CAN/CSA-C22.2 No. 601.1-M90:2005, CAN/CSA-C22.2 No. 60601-1:2008, ANSI/AAMI ES 60601-1:2005. 25UX (Control No.) 4

Symbols on the packaging XXXX CE marking with identification number of the Notified Body This way up DataMatrix Code for product information including UDI (Unique Device Identification) Data structure in accordance with Health Industry Bar Code Fragile, handle with care Permitted temperature range Keep dry Humidity, Limitation»Der Grüne Punkt«(The Green Dot) trademark of Duales System Deutschland GmbH Trademark of RESY OfW GmbH for identification of recyclable transport and outer packaging of paper and cardboard Caution! Federal law restricts this device to sale by or on the order of a dentist, physician or any other practitioner licensed by the law of the state in which he or she practices to use or order the use of the device. 5

1. Introduction For your safety and the safety of your patients These Instructions for use explain how to use your medical device. However, we must also warn against possible hazardous situations. Your safety, the safety of your team and, of course, the safety of your patients are of paramount importance to us. Observe the safety notes on pages 11 to 13. Intended use Air drive system including supply with media for dental handpieces and dental air motors, which are intended for general dental use e.g.: removing carious materials, preparing cavities and crowns, removing fillings, finishing tooth and restoration surfaces, polishing, prophylaxis and endodontics. Misuse may damage the medical device and hence cause risks and hazards for patient, user and third parties. Qualifications of the user We have based our development and design of the medical device on the dentists, dental hygienists, dental employees (prophylaxis) and dental assistants target group. 6

1. Introduction Production according to EU Directive The medical device meets the requirements of Directive 93/42/EEC. Responsibility of the manufacturer The manufacturer can only accept responsibility for the safety, reliability and performance of the medical device when it is used in compliance with the following directions: > The medical device must be used in accordance with these Instructions for use. > The medical device has no components that can be repaired by the user. Assembly, modifications or repairs must only be undertaken by an authorised W&H service partner (page 37). > The electrical installation at the premises must comply with the regulations laid out in IEC 60364-7-710 (»Installation of electrical equipment in rooms used for medical purposes«) or with the regulations applicable in your country. > Unauthorised opening of the equipment invalidates all claims under warranty and any other claims. 7

2. Electromagnetic compatibility (EMC) Medical electrical equipment is subject to particular precautions with regards to EMC and must be installed and put into operation in accordance with the EMC notes included. W&H guarantees the compliance of the device with the EMC requirements only when used with original W&H accessories and spare parts. The use of accessories and spare parts not approved by W&H can lead to an increased emission of electromagnetic interference or to a reduced resistance against electromagnetic interference. You can find the current EMC manufacturer s declaration on our website at http://wh.com or request a copy directly from the manufacturer. HF communication equipment Do not use any portable and mobile HF communication equipment (such as e.g., mobile telephones) during operation. These may affect medical electrical equipment. 8

3. Unpacking Remove the turbine handpiece and the Roto Quick coupling. Remove the power supply unit and the hose. Lift out the complete insert. Remove the insert of the hose and the protective packaging for the supply unit. Remove the power supply unit, mains cable and the air supply hose. W&H packaging is environmentally friendly and can be disposed of by industrial recycling companies. However, we recommend that you keep the original packaging. 9

4. Scope of delivery REF 30242000 REF 07883900 REF 06700100 Primea control unit Power supply unit Air supply hose Mains cable REF 01343700 (EU) REF 04280600 (CH) REF 05901800 (DK) REF 02821400 (USA, CAN, J) REF 03212700 (UK, IRL) REF 02909300 (AUS, NZ) REF 05333500 (BR) 10

5. Safety notes > Before using the medical device for the first time, store it at room temperature for 24 hours. > Only use the mains cable REF 07883900. > Only connect the mains cable to grounded socket outlets. > Check the medical device with cable and the turbine handpiece for damage and loose parts each time before using. Correct any faults or refer to an authorised W&H service partner (see page 37). > Check the settings every time the medical device is restarted. > Do not operate the medical device if it is damaged. > Always ensure the correct operating conditions and cooling function. > Always ensure that sufficient and adequate cooling is delivered and ensure adequate suction. > Never pull the air supply hose from the medical device while the compressed air is turned on. > Perform a test run each time before using. > Run the rinse function for the dental unit once per day. > Follow the recommendations of the transmission instruments and rotary instrument manufacturers. > Operation is only permitted on dental units that conform to the IEC 60601-1 (EN 60601-1) und IEC 60601-1-2 (EN 60601-1-2) standards. Inappropriate use In addition to unauthorised assembly, installation, modification or repairs to the medical device and non-compliance with our instructions, invalidates all claims under warranty and any other claims. 11

5. Safety notes Danger zones M and G In accordance with IEC 60601-1 / ANSI/AAMI ES 60601-1, the medical device is not suitable for use in potentially explosive atmospheres or with potentially explosive mixtures of anaesthetic substances containing oxygen or nitrous oxide. The medical device is not suitable for use in oxygen enriched atmospheres. Zone M, also referred to as the»medical environment«, includes the part of a room in which potentially explosive atmospheres may occur as a result of the use of analgesics or medical skin cleaning or disinfectant agents, but only in small quantities and only for a short time. Zone M comprises a truncated pyramid below the operating table which is tilted outwards at a 30 angle. Zone G, also referred to as an»enclosed medical gas system«, comprises not necessarily fully enclosed cavities in which permanent or temporary potentially explosive mixtures may be generated, supplied or used in small quantities. Risks due to electromagnetic fields The functionality of implantable systems, such as cardiac pacemakers and implantable cardioverter defibrillator (ICD) can be affected by electric, magnetic and electromagnetic fields. > Find out if patient and user have implanted systems before using the medical device and consider the application. > Weigh the risks and benefits. > Keep the medical device away from implanted systems. 12

5. Safety notes > Make appropriate emergency provisions and take immediate action on any signs of ill-health. > Symptoms such as raised heartbeat, irregular pulse and dizziness can be signs of a problem with a cardiac pacemaker or ICD. Medical device The medical device is classed as»conventional equipment«(closed equipment without protection against the ingress of water). Power supply unit Only use the power supply unit supplied. Mains cable Only use the mains cable supplied. Plug the mains cable only into a earthed power socket. Disconnect the medical device in dangerous situations from the power supply. > Pull the power plug out of the socket. System failure A total system failure does not constitute a critical fault. > Simply disconnect the medical device and then connect again. 13

6. Guide to display Program 1 Power Speed display in rpm PLUS / MINUS keys Tactile Program keys MODE key 14

7. Installing the support Installation example Instrument tray Support (optional) horizontal attachment 15

8. How to remove the display Installing the display / display holding Display holding Cable duct (Cable length 70 cm) 16

9. Overview of the rear Connection for power supply unit Connection for air supply hose Standard 4-hole connection for dental unit s supply hose (in accordance with ISO 9168 Type 3) Optional: Adaptor for Borden 2(3)-hole connection 020399000 Adaptor for Borden 2(3)-hole connection (in accordance with ISO 9168 Type 4) 17

10. Start-up General Ensure that the medical device can be disconnected from the power supply at any time. Screw on dental unit s supply hose (in accordance with ISO 9168 Type 3). Pay attention to the positioning! Optional: Adaptor for Borden 2(3)-hole connection Connect/remove the air supply hose (independent of direction): > Turn off the central air supply! > Use only the filtered, oil-free and cooled air supplied by dental compressors (maximum particle size 25 μm). Insert the air supply hose until back stop. Pull the ring back. At the same time, pull out the air supply hose. Outer diameter of supply hose: Inlet pressure air supply hose: Air consumption: 6 mm 600 800 kpa (6 8 bar, 87 116 psi) maximum 75 Nl/min > Before using check the inlet pressure of the air supply hose to the specified values. 18

10. Start-up General Connect the mains cable to the medical device. Connect the mains cable to the power supply unit. Plug the mains cable into a earthed power socket (90 264 V AC, 47 63 Hz). Pull the power plug out of the socket. 19

10. Start-up General Connect the Roto Quick coupling and turbine handpiece (see Primea Advanced Air Instructions for use). All products which are approved for the operation with a supply hose according to ISO 9168 and an operating pressure of 3 bar can be used. > W&H does not guarantee the proper function of the lighting (halogen, LED) for these products! > Products approved for a standard operation below 3 bar may be damaged and therefore may not be used! 20

11. Factory settings / keys Program 1 Display shows P1: Power 320,000 rpm Program 2 Display shows P2: Power 160,000 rpm Program 3 Display shows P3: Tactile 60,000 rpm PLUS key Increase speed, maximum 320,000 rpm, possible during use MINUS key Reduce speed to minimum 60,000 rpm, possible during use MODE key Switch between»power«and»tactile«modes. Power: In»Power«mode, the set speed is also constantly maintained when pressure mounts on the rotary instrument, which translates to a higher removal rate. Tactile: The»Tactile«mode permits a reduction in the removal rate when pressure mounts on the rotary instrument. 21

12. Operation Changing / saving the speed and mode The speed can be set at P1, P2, P3 from minimum 60,000 rpm to maximum 320,000 rpm. Press the program key (P1, P2 or P3). Press the MODE key to change from»power«to»tactile«mode.»tactile«appears on the display. Increase speed r Reduce speed t Press program key (P1, P2 or P3) for approximately 2 seconds to save. The set values flash and an acoustic signal is emitted to confirm that all the settings have been saved. 22

13. Operation General set-up menu You can return to the set-up menu from any program by pressing on the PLUS and MINUS keys at the same time. Press the PLUS and MINUS keys simultaneously for approximately 3 seconds.»setup«appears on the display. Press program key P1 to navigate in the set-up menu. Press the PLUS / MINUS key to change the settings in the respective set-up menu item. r Press program key P1 for approximately 2 seconds to save. The set values flash and an acoustic signal is emitted to confirm that all the settings have been saved. 23

14. Operation Back to original program Press the PLUS and MINUS keys simultaneously for approximately 3 seconds to exit the set-up menu. The original program appears on the display. 15. Reset factory settings Press program keys P1, P2 and P3 simultaneously for approximately 3 seconds (see page 21). 24

16. Operation Set-up menu»pedalsoundled«> Pedal: ON/OFF > Pedal: STEP: variable from 60,000 rpm to value set (maximum 320,000 rpm) > Sound: ON > Sound: OFF > Setting for fade-out time: from 0 to maximum 60 seconds Factory setting = 5 seconds 25

17. Deactivate standby mode You can exit standby mode by actuating the foot control or pressing the keys. 18. Active resuction stop The Primea medical device has an active resuction stop. During slowing down of the rotary instrument the active resuction stop creates an overpressure in the head of the Primea turbine handpiece. This prevents aerosol particles from being sucked into the Primea turbine handpiece as the rotor slows down. This function is only activated with the Primea turbine handpieces. 26

19. Error messages Display Description of error Solutions Error 1 Overheating/overloading of electronics > Disconnect medical device from power supply Wait 5 minutes and allow the system to cool Switch the medical device back on again and restart the function Error 2 Pedal of the foot control pressed during switching on > Do not press the pedal of the foot control Error 4 Display keys pressed during switching on > Do not press the display keys Error 5 Error 6 Error 7 Reboot Running time limiter as a result of 15 minutes of continuous operation Error with»primea Advanced Air«applied part Operating error»primea Advanced Air«> Check the pedal of the foot control > Do not press the pedal of the foot control any more (release completely) > Check that the turbine handpiece is correctly attached to the coupling Replace the turbine handpiece > Check supply air pressure > Operation standard turbines mode (see page 29) > Switch the power supply off and on again > Restart system Error e. g.: 05 6303 > Immediately contact an authorised W&H service partner If the error messages described cannot be resolved a check by an authorised W&H service partner is required (see page 37). 27

20. Functionality test Primea Advanced Air turbine handpiece Operate foot control. System checks the functioning of the Primea Advanced Air turbine handpiece. Operate foot control during check. Wait until the check has finished (maximum 8 seconds).»bar«appears on the display. Primea Advanced Air turbine handpiece detected or ready for use: Advanced Air mode starts. Primea Advanced Air turbine not detected or ready for use:»bar«and»!«flash 6 times on the display.»error 7«appears on the display. r Check supply air pressure. Check, if any modifications in the supply line have to be made (e.g., connection, elimination of bottlenecks) or Press»P1«and»Mode«key simultaneously for approximately 3 seconds to access the standard turbines mode. 28

21. Operation standard turbine Standard turbines also can be used with the Primea medical device. Operate foot control.»error 7«appears on the display. Press»P1«and»Mode«key simultaneously for approximately 3 seconds to access the standard turbines mode. An acoustic signal is emitted. Standard turbines mode»p1«and»mode«permanently flash. Standard turbines mode is indicated by a dotted line and»basic«. Primea Advanced Air is no longer enabled! It is no longer possible to set the speed / mode. Press»P1«and»Mode«key simultaneously for approximately 3 seconds to return to Primea Advanced Air Mode. An acoustic signal is emitted. 29

22. Hygiene and maintenance Follow your local and national laws, directives, standards and guidelines for cleaning and disinfection. > Wear protective clothing. > Clean and disinfect the medical device immediately after every treatment. Medical device > The medical device is not approved for mechanical cleaning (thermo washer disinfector) and sterilization. > Do not immerse the medical device in water or clean it under running water. Pre-disinfection > If heavily soiled, clean first with disinfectant cloths. Only use disinfectants that have no protein-fixing effects. Manual cleaning and disinfection The display of the medical device is sealed and can be wiped. W&H recommends wiping down with disinfectant. Use only disinfectants which do not contain chlorine and which are certified by officially recognized institutes. Note the manufacturer s specifications for the use of the disinfectants. 30

22. Hygiene and maintenance Before resuming operation > Wait until the medical device is completely dry. Moisture in the plug can lead to a malfunction. (Risk of short circuit) Cable, hose Do not twist or kink the cable! Do not coil it too tightly! The supply hose is not approved for mechanical cleaning (thermo washer disinfector) and sterilization. Pre-disinfection > If heavily soiled, clean first with disinfectant cloths. Only use disinfectants that have no protein-fixing effects. Use only disinfectants which do not contain chlorine and which are certified by officially recognized institutes. Note the manufacturer s specifications for the use of the disinfectants. 31

23. W&H Accessories Use only original W&H accessories and spare parts or accessories approved by W&H. Suppliers: W&H Partner REF 07883900 REF 10402400 REF 10403400 REF 30222000 REF 30221000 REF 07912400 Power supply unit Roto Quick coupling RQ-24 Roto Quick coupling RQ-34 Primea Advanced Air turbine handpiece RG-97 L Primea Advanced Air turbine handpiece RK-97 L Screw kit 020399000 Adaptor for Borden 2(3)-hole connection 07712700 Display holding with screw kit 07842200 Support with screw kit 07944590 Tray 32

24. Service Regular checking of the medical device and accessories Regular servicing including the accessories is necessary and should be carried out at least once every three years, unless shorter intervals are prescribed by law. The inspection must be undertaken by a qualified organisation and must include the following procedures: > Visual inspection for external damage > Check for any changes which could jeopardise safety > Measurement of the device leakage current > Measurement of the patient leakage current > Visual inspection of internal components on suspicion of safety interference, e.g., mechanical damage of the enclosure or indicators of overheating > Check of whether the correct power supply unit is being used The regular service must only be performed by an authorised W&H service partner (see page 37). Repair If a defect occurs, always return all the equipment, as it is also necessary to inspect all of the control electronics! Returns > Refer all questions to an authorized W&H service partner (see page 37). > Always return equipment in the original packaging! > Do not twist or kink the cable! Do not coil it too tightly! (Risk of damage) 33

25. Technical data Model AF-100 Power supply: 30 32 V Mains voltage: 100 240 V Dimensions in mm (WxDxH): 156 x 211 x 92 ISO 9168 supply connection Forced air pressure: 3 ± 0.3 bar Water pressure: 0.7 2 (1.5) bar Chip air pressure: 3 ± 0.3 bar Ambient conditions Temperature during storage and transport: -40 C to +70 C Humidity during storage and transport: 8% to 80% (relative), non-condensing Temperature during operation: +10 C to +35 C Humidity during operation: 15% to 80% (relative), non-condensing Permitted ambient pressure: 70 106 kpa Pollution level: 2 Overvoltage category: II Altitude: up to 3,000 m above sea level Classification according to Paragraph 6 of the General Specifications for the Safety of Medical Electrical Equipment according to IEC 60601-1 / ANSI/AAMI ES 60601-1 34 Type B applied part (not suitable for intracardiac application)

26. Disposal Ensure that the parts are not contaminated on disposal. Follow your local and national laws, directives, standards and guidelines for disposal. > Waste electrical equipment > Packaging 35

Explanation of warranty terms This W&H medical device has been manufactured with great care by highly qualified specialists. A wide variety of tests and controls guarantees faultless operation. Please note that claims under warranty can only be validated when all the directions in the Instructions for use have been followed. As the manufacturer, W&H is liable for material or manufacturing defects within a warranty period of 24 months from the date of purchase. Accessories and consumables (RM seal) are excluded from the warranty. We accept no responsibility for damage caused by incorrect handling or by repairs carried out by third parties not authorized to do so by W&H! Claims under warranty accompanied by proof of purchase must be sent to the vendor or to an authorized W&H service partner. The provision of service under warranty extends neither the warranty period nor any other guarantee period. 24 months warranty 36

Authorised W&H service partners Visit W&H on the Internet at http://wh.com You can find your nearest W&H service partner at»service«in the menu. If you do not have Internet access, please contact: W&H (UK) LIMITED, 6 Stroud Wood Business Centre, Park Street, St Albans, Hertfordshire AL2 2NJ, United Kingdom t + 44 1727 874990, f + 44 1727 872254, E-Mail: technical.uk@wh.com W&H Impex Inc., 6490 Hawthorne Drive, Windsor, Ontario, N8T 1J9, Canada t + 1 800 2656277, 1 519 9446739, f + 1 519 9746121, E-Mail: service.ca@wh.com A-DEC AUSTRALIA CO. INC., Unit 8, 5-9 Ricketty Street, Mascot NWS 2020, Australia t + 61 2 83324000, f + 61 2 83324099, E-Mail: a-dec@a-dec.com.au 37

Manufacturer W&H Dentalwerk Bürmoos GmbH Ignaz-Glaser-Straße 53, 5111 Bürmoos, Austria t +43 6274 6236-0, f +43 6274 6236-55 office@wh.com wh.com Form-Nr. 50852 AEN Rev. 000 / 24.08.2016 Subject to alterations