Introduction Advantages of cooperating with Our service - our conditions Our standard central control valve

Similar documents
INSTRUCTION MANUAL. Automatic Water Softener System. Model: PSE-08. Xsential Water Filtration Systems

UsER manual for Watersens ph -REDOX

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

GENO -Flushing Compressor Product Data Sheet F 02

WatMan WATER RO SYSTEMS FOR DESALINATION

swimming pool technology

Softeners Clack Model V125DTH Medical / Industrial Series Operation and Service Manual

The ultimate in water softening

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

TECHNICAL ACCESSORIES

Prestige Water Equipment Ltd.

Flamco Flamco-Fill STA Flamco-Fill STM

CCT-7320/ROC-2313 Reverse Osmosis Controller

ScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Hot Water Stationary Unit

Prestige Water Equipment Ltd.

Installation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14

CO 2 and O 2 scrubbers

SOFTENER D-DF & D-UF Series

Variable Area Flow Meters

Used with Dissolution Tester for Fraction and Flow Measurements

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

The best water for your pool from a single source.

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

Autotrol Performa ProSoft

Reverse Osmosis System Installation Guide and Operation Manual.

RAC 2200-X/Y-MV DOMESTIC WATER METER TEST BENCH UP TO DN 50 ( 2 ) MANUALLY OPERATED

Integral type Differential pressure flowmeter VNT Series

Date September 2017 Order no inter. Operation Manual GENO-mat FE-Z Deferrisation system

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

High Pressure Breathing Air Compressors

CAPITAL CONTROLS SERIES NXT3000

Device must be installed immediately downstream of an AS/NZS backflow prevention valve! Please contact your plumber!

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

VACCUPERM Vacuum chlorine gas dosing systems

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Product Range. High performance and economic high pressure solutions Made in Germany

POOL BACKWASH SYSTEM. Installation manual. Proudly manufactured by

Workshop Compressors CLASSIC Series

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Easy Nest Kits. Installation Suggestions

Pool and Spa. Water Testing

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Municipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Measurement of Low GAS & Liquid Flows

CNG FILLING STATIONS

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

829S1 Series Flexflo Pilot

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

/ /

Davey Pool & Spa New Products Launch

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Highest Quality. Gas Chlorination Systems

V230 VALVE OPERATING MANUAL

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

V230 VALVE OPERATING MANUAL

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

Recirculating Coolers

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

hth EASIFLO SYSTEM New Generation for 2015 Feeder specifications hth EASIFLO The perfect solution for treatment of commercial swimming pools

S A W A Y G E N E R A L T R A D I N G L L C. Page 1- FLOATING DISPENSERS CHLORINE AND ph TEST KIT TEST KIT REFILL BOTTLE 123

Technical Service Bulletin March 2015 TSB142.01

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Workshop Compressors CLASSIC Series

AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

Control Valves, Fittings and Accessories

We measure it. For gas and water installers. testo hpa. bar

Self-supporting hot water high pressure cleaner on trailer Hudson 315

SonoMeter 30 Energy Meters

Pneumatic retractable fitting for simple commercially available control units or process applications

Pressure Reducing Valve DMV 755

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

WATER SOFTENER. Instructions Manual Use and Maintenance

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

Single-pass and Double-pass Osmosis

1- CHLORINE 2- NEUTRALIZER 3- BROMINE 4- FLOCCULANT. 5- ph MINUS. 6- ph PLUS 7- WASP REPELLENT 8- NET'BORD 9- ALGAECIDE 10- WINTERIZING

WORKHOLDING APPLICATION BOOKLET

Best Practice Guide, Servomex 2700

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Ultrasonic level transmitter and indicator

6200 Isoperibol Calorimeter Model Number: 6200

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Pressure Reducing Valve DMV 750 set range: bar

RAM 4021-DPX Operation Manual

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

ELADOS EDP L Diaphragm Metering Pump Type

safety shut-off Valve HON 703 / HON 704

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS

Transcription:

Introduction Advantages of cooperating with Our service - our conditions Our standard central control valve Gravel-Filter Deferrisation Systems Pressure filter EKF, made of stainless steel (V4A) Pressureless filter type OKF, made of plastic (PP) and V4A Oxidation-air-compressor, oxidator Backwash device type RSL/DPR-EKF, pressure-cushion-regulation OKF controls: Level control, backwash control, complete control Level control, automatic backwash device type RSL/DPR-OKF Industrial gravel filter systems KFE (single) and KFD (double) Pressureless industrial gravel-filter systems type OKF-2500-PE and type OKFI Compact-Deferrisation Systems Dirt filtration type SFZ Compact-deferrisation type BM and type BM-AIR Compact-deferrisation / demanganesation type MG Compact-deferrisation type ES (increase of ph-value) Compact-deferrisation / softening type MEV-CR1 and type MEV -CR2 Double-tank deferrisation / softening type DEW-CR1 and type DEW-CR2 Removal of humic acid (yellow colour) type MWO Softening Systems Information on soft water Cabinet softening type KAWK-D and type KAWK Double-tank cabinet softening system type KAP Single softening system type MWK-D and type MWK Hot-water softening type HMZK Double-tank softening system type DWK and type DWK-1/-2/-3 Industrial double-tank softening system type DWKI Automatic hardness-control device Information on DVGW-certification mark for water treatment systems Nitrate-Reduction Systems Information on nitrate Cabinet nitrate-reduction system type KAWN Single nitrate-reduction system type MWK Double-tank nitrate-reduction systems type DWN and type DWN-1/-2 Dosing Systems/Disinfection Compact-proportional system type NG5R and type NG10R Container-proportional dosing system type BD Dosing chemicals Information on UV-Oxidation UV-disinfection type UV11 UV60 Ultra-filtration filter candles type INDUWA Fresh Reverse Osmosis/Full Desalination Information on reverse osmosis Small-osmosis system type RO-5T50 Compact system type ROC, l/h Full-desalination system type VEM (heater filling) Reverse-osmosis system type ROW 400 l/h (wall system) Reverse-osmosis system type RO 400 l/h (standing system) Reverse-osmosis system type RO 600 1500 l/h (standing system) 12 34 56 Extras Backwash protection filter 1 2 type RF Plastic protection filter for 9 ¾ and 20 filter candles Connection/blending mountings, connecting hoses Membrane-pressure-container, pressure container Measuring instruments 02.16 7

Type: KAWK-D Fully automated, time-/water-meter-controlled single system, incl. features according to DVGW guidelines, with integrated cabinet for regeneration fluid Cabinet for salt storage, incl. brine valve and shield tube, with integrated pressure tanks made of corrosion-resistant GFRP, with distribution system Easy-to-maintain central control valve in a robust plastic design, with excellent performance values (6m³/h at Δp1 bar), water meter turbine, integrated mixing valve and bypass valve, and integrated check valve on inlet side Special control features according to DVGW guidelines, with extended options, incl. chlorine cell, surveillance of regeneration and salt deficiency, alarm signal Economical upflow regeneration with proportional brining for optimal capacity utilization Forced regeneration after a maximum of 4 days for optimal system hygiene (DVGW guidelines) Prograable for up to 9 regeneration cycles, with free choice of duration and sequence Illuminated display indicating either time, current water flow (l/min), or remaining capacity (m³) Regeneration initiation additionally possible via time control, remote control, or manually Diverse data (water use, number of regenerations, etc.) available for diagnosis Maintenance reminder with customized display showing seller s contact data Connection: R 1 outside Operating pressure: 2-8 bar 230 V / 50 Hz System Type: INDUWA- KAWK-D FN18 KAWK-D FN30 KAWK-D FN36 Amount of Resin Liter 6 12 25 Capacity dh x m 3 20 42 87 Salt Consumption / Full-Regen. ca. kg 1,0 1,9 4,0 Water Consumption / Regen. ca. Liter 70 90 160 Nominal Flow * m 3 /h 2,0 2,6 3,5 System Height (total) 660 970 1120 Cabinet Width Cabinet Depth System Weight (dry) ca. kg 15 22 36 Item Number 901415 901416 901416 * nominal flow for raw water blended from 20 dh to 8 dh

Type: KAWK Fully automated, time-/water-meter-controlled single system, with integrated cabinet for regeneration fluid Cabinet for salt storage, incl. brine valve and shield tube, with integrated pressure tank made of corrosion-resistant GFRP, with distribution system Easy-to-maintain central control valve in a robust plastic design, with excellent performance values (6m³/h at Δp1 bar), with water meter turbine, integrated mixing valve, and integrated bypass valve Upstream dirt filter not always necessary because the central control valve is insensitive Prograable for up to 9 regeneration cycles, with free choice of duration and sequence Illuminated display indicating either time, current water flow performance (l/min), or remaining capacity (m³) Regeneration control with self-learning mode for optimal capacity utilization Regeneration initiation additionally possible via time control, via remote control, or manually Divers data (water use, number of regenerations, etc.) available for diagnosis Economical salting prograable Connection: R 1 outside Operating pressure: 2-8 bar 230 V / 50 Hz Available features for retrofitting: Chlorine cell for improved system hygiene Extension to double-tank system Conversion for alternative applications Separate salt level detector Optional: Special control with extended options, incl. chlorine cell, surveillance of regeneration and salt deficiency, alarm signal, pre-selectable service reminders and proportional brining Upflow regeneration System Type: INDUWA- KAWK- SM KAWK- FN18 KAWK- FN30 KAWK- FN36 Amount of Resin Liter 3 6 12 25 Exchange Capacity dh x m 3 10 20 42 87 Salt Consumption / Full-Regen. ca. kg 0,7 1,4 2,9 6 Nominal Flow* m 3 /h 1,5 2,0 2,6 3,5 System Height (total) 660 970 1120 Cabinet Width Cabinet Depth 230 400 System Weight (dry) ca. kg 10 15 22 36 Item number 901014 901015 901016 901017 * nominal flow for raw water blended from 20 dh to 8 dh

Type: KADWK utility model protection!! Fully automated, water-meter-controlled double-tank system, with integrated container for regeneration agents, for a continuous water supply via alternating service Cabinet container for salt storage, incl. brine valve and protection tube, with two integrated pressure containers made of corrosion-resistant GFRP Easy-to-maintain central control valve with water-meter turbine in a robust plastic design, with excellent performance values, (6 m 3 /h at Δp1 bar), upflow regeneration Special control with multicolour display and many program and inquiry options, surveillance of regeneration and salt deficiency, maintenance reminder and alarm output Chlorine cell for improved system hygiene Integrated check valve on inlet side Filling of pressure containers with high-performance ion exchange resin Separate assembly/bypass block made of brass with integrated blending 2 highly flexible stainless-steel-reinforced hoses, optionally 500, 800 or 0 long Robust and compact model Operating pressure: 2-8 bar 230 V / 50 Hz Water temperature: max. 40 C Connection: R 1 inside Waste water connection: hose nozzle ½ NEW PRODUCT exclusively by INDUWA System Type: INDUWA- KADWK- 6 KADWK- 15 Nominal Flow* m 3 /h 2,0 2,5 Amount of Resin Liter 2 x 6 2 x 15 Capacity dh x m 3 2 x 20 2 x 52 Salt Consumption / Regeneration ca. kg 1,0 1,9 System Height (total) 560 1160 Container Width System Width Container Depth 460 460 Rinse Water / Regeneration ca. Liter 50 90 Salt Reserve ca. kg 40 90 System Weight (dry) ca. kg 25 48 Item Number 901018 901019 * nominal flow for raw water blended from 20 dh to 8 dh 05.16

Type: MWK-D Fully automated, time-/water-meter-controlled single system, incl. features according to DVGW guidelines, with separate cabinet for regeneration fluid Easy-to-maintain central control valve in a robust plastic design with excellent performance values [6 m 3 /h (1 valve) or 7,8 m 3 /h (1 ¼ valve) at Δp = 1 bar], with water meter turbine, integrated mixing valve and integrated bypass valve Separate salt storage container made of PE, with sieve bottom, brine valve, and shield tube Special control features according to DVGW-guidelines, with extended possibilities incl. chlorine cell, surveillance of salt regeneration and salt deficiency, and alarm signal Economical upflow regeneration with proportional brining for optimal capacity utilization Forced regeneration after a maximum of 4 days for optimal system hygiene (DVGW guidelines) Prograable for up to 9 regeneration cycles, with free choice of duration and sequence Illuminated display indicating time, current water flow (l/min), or remaining capacity (m³) Regeneration initiation additionally possible via time control, via remote control, or manually Divers data (water use, number of regenerations, etc.) available for diagnosis Maintenance reminder with customized display showing seller s contact data Operating pressure: 2-8 bar 230 V, 50 Hz Available features for retrofitting: Extension to double-tank system Additional filter material for odour elimination. External alarm notification System Type: INDUWA- MWK-D -0730 Image: MWK-D-1044 MWK-D -0844 MWK-D -1044 MWK-D -1248 MWK-D -1354 Amount of Resin Liter 12 25 37 50 75 Capacity dh x m 3 42 87 130 175 262 Salt Consumption/ Full-Regen. ca. kg 1,9 4,0 6,0 8,0 12 Nominal Flow * m 3 /h 1,2 1,8 2,7 3,6 4,8 Connection Entrance/Exit R outside 1 1 1 1 1 Waste Water Connection Nozzle Hose ½ ½ ½ ¾ ¾ Salt-/Brine-Cabinet Height Content Softening Pressure Tank Liter 190 970 210 1 600 260 1 310 1430 570 830 340 1570 System Height (total) System Weight (dry) ca. kg 21 33 41 52 82 Item Number 901430 901431 901432 901433 901434 * nominal flow for raw water blended from 20 dh to 8 dh

Typ: MWK Fully automated, time-/water-meter-controlled single system, with separate cabinet for regeneration fluid Easy-to-maintain central control valve in a robust plastic design with excellent performance values [6 m3/h (1 valve) or 7,8 m3/h (1 ¼ valve) at Δp = 1 bar], with water meter turbine, integrated mixing valve and integrated bypass valve Upstream dirt filter not always necessary because the central control valve is insensitive Prograable for up to 9 regeneration cycles, with free choice of duration and sequence Illuminated display indicating time, current water flow (l/min), or remaining capacity (m³) Regeneration control with self-learning mode for optimal capacity utilization Regeneration initiation additionally possible via time control, via remote control, or manually Divers data (water use, number of regenerations, etc.) available for diagnosis Pressure tank made of corrosion-resistant GFRP, with distribution system Separate salt storage container made of PE, with sieve bottom, brine valve, and shield tube Economical salting prograable Operating pressure: 2-8 bar 230 V, 50 Hz Available features for retrofitting: Chlorine cell for improved system hygiene Extension to double-tank system Conversion for alternative applications Separate salt level detector Optional: Special control with extended options, incl. chlorine cell, surveillance of regeneration and salt deficiency, alarm signal, pre-selectable service reminders and proportional brining Upflow regeneration Image: MWK-1044 System Type: INDUWA- MWK -0730 MWK -0844 MWK -1044 MWK -1248 MWK -1354 MWK -1465 MWK -1665 Amount of Resin Liter 12 25 37 50 75 125 Capacity dh x m 3 42 87 130 175 262 350 437 Salt Consumption / Regen. ca. kg 3 6 9 12 18 24 30 Nominal Flow (max.) * m 3 /h 0,5 1,0 1,5 2,0 3,0 4,0 5,0 Connection Entrance/Exit R außen 1 1 1 1 1 1 ¼ 1 ¼ Rinse Water Connection Schlauch ½ ½ ½ ¾ ¾ ¾ ¾ Salt-/Brine-Cabinet Height Content Softening Pressure Tank System Height (total) Liter 190 970 210 1 600 260 1 310 1430 570 830 340 1570 840 300 370 1840 840 300 410 1840 System Weight (dry) ca. kg 21 33 41 52 82 124 148 Item Number 901030 901031 901032 901033 901034 901035 901036 * Nominal flow in long-term service, with a guaranteed final hardness of 0.1 H. For domestic households, soft water is mixed with hard water (blending) to gain a hardness of 5 8 dh. As a result, the nominal flow is significantly higher.

Type: HMZK for HOT WATER Fully automated, time-controlled single system, for the softening of hot water, with separate container for regeneration fluid for a temperature of up to 65 C Pressure tank made of corrosion-resistant GFRP, with distribution system Central control valve made of red brass with 5 fixed-time-cycles and adjustable brine-tank-fillingtime-cycle, with a 7-day-program, with integrated blending and bypass valve Regeneration initiation possible manually Separate salt storage container made of PE, with sieve bottom, brine valve, and shield tube Economical salting prograable Connection: Rp 1, inside Operating pressure: 2-8 bar 230 V, 50Hz Water temperature: max. 65 C Larger hot water systems, optionally water-meter-controlled, or systems for a water temperature of up to 82 C, are available on demand. Double-tank systems as hot water models also available. Optional: External chlorine cell for improved system hygiene External salt level detector Note Regular maintenance necessary at least 2x a year. System Type: INDUWA- HMZK- 0730 Image: HMZK 1044 HMZK- 0844 HMZK- 1044 HMZK- 1054 Amount of Resin Liter 12 25 37 50 Capacity dh x m 3 42 87 130 175 Nominal Flow (max.) * m 3 /h 0,5 1,0 1,5 2,0 Salt-/Brine-Cabinet Height Content Softening Pressure Tank Liter 800 105 System Height (total) 190 950 210 1310 260 1310 260 1570 Salt Consumption / Regen. ca. kg 3 6 9 12 System Weight (dry) ca. kg 22 34 42 52 Item Number 901050 901051 901052 901053 * Nominal flow in long-term service, with a guaranteed final hardness of 0.1 H. For domestic households, soft water is mixed with hard water (blending) to gain a hardness of 5 8 dh. As a result, the nominal flow is significantly higher. 800 105 800 105 800 105

Type: DWK Fully automated, water-meter-controlled double-tank system, with integrated cabinet for regeneration fluid, for a continuous supply of soft water via alternating service Easy-to-maintain central control valve in a robust plastic design on one pressure tank, tank adaptor with connecting tubes on other pressure tank, with microprocessor control incl. water meter turbine and added bypass, without blending High flow performance: 6 m 3 /h at Δp1 bar Upstream dirt filter not always necessary because the central control valve is insensitive Prograable for up to 9 regeneration cycles, with free choice of duration and sequence Illuminated display indicating either time, current water flow performance (l/min), or remaining capacity (m³) Regeneration initiation additionally possible via time control or manually Divers data (water use, number of regenerations, etc.) available for diagnosis 2 pressure tanks made of corrosion-resistant GFRP, with distribution system Separate salt storage container made of PE, with sieve bottom, brine valve, and shield tube Filling of pressure tanks with high-performance special-filter-material Economical salting prograable Connection (in-/outlet): R 1 outside Operating pressure: 2-8 bar 230 V / 50 Hz Waste water connection: ½ or ¾ nozzle hose External mounting necessary for blending. Available features for retrofitting: Chlorine cell for improved system hygiene Conversion for alternative applications Separate salt level detector Optional: Special control with extended options, incl. chlorine cell, surveillance of regeneration and salt deficiency, alarm signal, pre-selectable service reminders Upflow regeneration Image: DWK-1044 System Type: INDUWA- DWK- 0730 DWK- 0844 DWK- 1044 DWK- 1248 DWK- 1354 Amount of Resin per Tank Liter 12 25 37 50 75 Capacity per Pressure Tank dh x m 3 42 87 130 175 262 Salt Consumption / Regen. ca. kg 3 6 9 12 18 Nominal Flow (max.) * m 3 /h 0,5 1,0 1,5 2,0 3,0 Salt-/Brine-Cabinet Height Content Softening Pressure Tank System Height (total) Liter 800 190 950 800 210 1290 570 830 260 1290 570 830 310 1410 570 830 340 1540 System Weight (dry) ca. kg 40 62 89 111 155 Item Number 901240 901241 901242 901243 901244 * Nominal flow in long-term service, with a guaranteed final hardness of 0.1 H. For domestic households, soft water is mixed with hard water (blending) to gain a hardness of 5 8 dh. As a result, the nominal flow is significantly higher.

Type: DWK 1/2 Fully automated, water-meter-controlled double-tank system, consisting of 2 complete single systems that are connected via an automatic valve and a tube system, for a continuous, fail-safe water supply via alternating service 2 easy-to-maintain central control valves in a robust plastic design, with excellent performance values [6 m 3 /h (1 valve) or 7,8 m 3 /h (1 ¼ valve) at Δp1 bar], with water meter turbine, if required with integrated mixing valve and integrated bypass valve Motor valve and prefabricated tube system made of Noryl, with plug-in wiring Upstream dirt filter not always necessary because the central control valves are insensitive Prograable for up to 9 regeneration cycles, with free choice of duration and sequence Illuminated display indicating either time, current water flow performance (l/min), or remaining capacity (m³) Regeneration initiation additionally possible via time control or manually Divers data (water use, number of regenerations, etc.) available for diagnosis 2 pressure tanks made of corrosion-resistant GFRP, with distribution system 2 salt storage containers made of PE, with sieve bottom, brine valve, and shield tube Economical salting prograable Operating pressure: 2-8 bar 230 V / 50 Hz Waste water connection: 2 x ¾ or 1 hose nozzle Available features for retrofitting: Chlorine cell for improved system hygiene Conversion for alternative applications Separate salt level detector Optional: Special control with extended options, incl. chlorine cell, surveillance of regeneration and salt deficiency, alarm signal Upflow regeneration Image: DWK1-1354 Amount of Resin per Tank Liter 50 75 125 Capacity per Full Salting dh x m 3 190 286 381 477 Pressure Tank Economical Salting dh x m 3 150 228 304 380 Nominal Flow (max.) * m 3 /h 2,0 3,0 4,0 5,0 Connection In-/Outlet R 1 1 1 ¼ 1 ¼ Salt-/Brine-Cabinet x Height x x 570 x 830 570 x 830 Content per Container Liter Softening Pressure Tank 310 340 370 410 System Height (total) 1590 1740 1990 1990 System Weight (dry) ca. kg 122 166 225 269 Salt Consumption / Full Salting ca. kg 10 15 20 25 Regeneration Economical Salting ca. kg 5 7,5 10 12,5 Item Number 901143 901144 901145 901146 * nominal flow in long-term service, with a guaranteed final hardness of 0.1 H System Type: INDUWA- DWK1-1248 DWK1-1354 DWK2-1465 DWK2-1665

Type: DWK 3 Fully automated, water-meter-controlled double-tank system, consisting of 2 complete single systems that are connected via an automatic valve and a tube system, for a continuous fail-safe water supply via alternating service Softening of iron- and manganese-free service and drinking water 2 easy-to-maintain central control valves with microprocessor control, in a robust brass design with excellent performance values (13,6 m 3 /h at Δp1 bar) 3/2-way motor valve and water meter made of brass, pre-piped with a pre-made PVC tube system, incl. 3 PVC ball valves and plug-in wiring Upstream dirt filter not always necessary because the central control valves are insensitive Prograable for up to 9 regeneration cycles, with free choice of duration and sequence Regeneration initiation additionally possible via time control or manually Illuminated display for standby/operating mode, indicating e.g. time, current water flow performance (l/min), remaining capacity (m³) Divers data (water use, number of regenerations, etc.) available for diagnosis 2 pressure tanks made of corrosion-resistant GFRP, with distribution system 2 salt storage containers made of PE, with sieve bottom, brine valve, and shield tube Economical salting prograable Operating pressure: 2-8 bar 230 V / 50 Hz Waste water connection: 2 x 1 hose nuzzle or 1 ½ muffle External mounting needed for blending. Available features for retrofitting: Chlorine cell for improved system hygiene Conversion for alternative applications Separate salt level detector Optional: Special control with extended options, incl. chlorine cell, surveillance of regeneration and salt deficiency, alarm signal and pre-selectable service reminder Image: DWK3-1465 System Type: DWK3-1465 1665 1865 2160 2469 Amount of Resin per Tank Liter 125 150 250 350 Capacity per Full Salting dh x m 3 477 572 763 954 1335 Pressure Tank Economical Salting dh x m 3 380 456 608 760 1064 Nominal Flow (max.) * m 3 /h 5,0 6,0 8,0 10,0 13,0 Connection (PVC sleeve) R 1 ½ 1 ½ 2 2 2 Salt-/Brine-Cabinet x Height Content per Container Liter 570 x 830 570 x 830 740 x 0 400 740 x 0 400 790 x 1060 500 Softening Pressure Tank System Height (total) 370 2 410 2 2220 550 2080 610 2330 System Weight (dry) ca. kg 260 310 390 640 Salt Consumption / Full Salting ca. kg 25 30 40 50 70 Regeneration Economical Salting ca. kg 12,5 15 20 25 35 Item Number 901160 901161 901162 901163 901164 * nominal flow in long-term service, with a guaranteed final hardness of 0.1 H

Type: DWKI Fully automated, water-meter-controlled double-tank system, with separate container for regeneration fluid, for a continuous fail-safe water supply via alternating service 2 pressure tanks made of corrosion-resistant GFRP, with distribution system Tube system with butterfly valves made of GGG/VA with double-acting pneumatic drive, with separate pilot valve each, manually controlled 2 manually operated butterfly valves each at entry and exit of the system Water jet injector with water rate indicator for dilution water and hand valves Manually operated drain valve and vent valve Sample trough made of stainless steel, with manometer and drain cocks PVC-tube system with wired automatic valves and contact water meter Switchboard with integrated SPS-control and control-touch-panel Stainless steel frame for storage of the mentioned components Salt storage containers made of PE, with sieve bottom, brine valve, and shield tube Operating pressure: 2-10 bar 230 V, 50 Hz Optional: Upflow regeneration Special filter material with minimal salt- and waste-water-consumption with simultaneous reduction of iron and mangenese Image: DWKI-3678 System Type: DWKI- 2469 3072 3678 4278 4882 Amount of Resin per Tank Liter 350 550 800 0 1400 Capacity per Full Salting dh x m 3 1335 2 3050 3815 5370 Pressure Tank Economical Salting dh x m 3 1064 1670 2430 3040 4255 Nominal Flow (min./max.) * m 3 /h 2,1-13 3,3-22 4,6-32 6,0-40 8,4-56 Connection (PVC flange) DN 50 80 80 Salt-/Brine-Container Height Content per Tank Liter 1055 1 0 1055 1 0 1055 1 0 1260 1535 1750 1260 1535 1750 Softening Pressure Tank Height 610 2 770 2 930 2300 1075 2600 1230 2650 Salt Consumption / Full Salting ca. kg 70 110 160 280 Regeneration Econimical Salting ca. kg 35 55 80 140 Item Number 901174 901175 901176 901177 901178 * nominal flow in long-term service, with a guaranteed final hardness of 0.1 H

- SUPPLIES Hardness Tester - Testomat Eco For the identification of remaining hardness via automatic titration Ideal for the qualitative surveillance of water softening systems, water blending systems, and drinking water systems. The microprocessor monitors the functional processing sequence and reports errors like reagent shortage, missing sample water, or measuring-chamber-pollution via alarm relay. The whole analysis sequence, including the filling and rinsing of the measuring cell, is controlled by a microprocessor. Additional features: Highly precise titration via piston dosing pump LCD-text-display for self-explaining menu-guided control surface Two selectable dh-threshold-values for the activation of external devices Analysis initiation via automatic interval mode (0-99 minutes), quantity-contingent via contact water meter, or via external activation Minimal indicator- and water-consumption Analogue exit 0/4 20 ma 230 V / 50 Hz Power intake: max. 30 VA Protection category: IP 65 Display: LCD-text-display, 2 rows Power exit: 0/4-20 ma Dimensions: 480(H)x380(W)x280(D) Sample water: Pre-pressure: 1-8 bar Temperature: 10-40 C Chemical requirements: ph 4-10, Fe < 0,5 mg/l, Cu /Al < 0,1 mg/l Process: depressurised Item number: 757025 Indicator Type 500 ml TH 5 TH 2025 TH 2 TH 2250 Measuring Range dh 0,05-0,5 0,25-2,5 1,0-10 2,5 25 Resolution dh 0,01 0,05 0,2 0,2 Consumption per Analysis, ca. ml 1,0 0,166 0,066 1,0 per dh Item Number 101070 101071 101072 101073 With one single device the listed measuring ranges and values of hardness can be measured through choice of indicator type. Available on demand: Testomat 0. With this device the carbonate hardness, the minus-mvalue, or the p-value can be measured through choice of indicator type. Additionally, devices are available for blending-regulation, for the measuring of dissolved iron, and for the measuring of free chlorine or total chlorine.

Central Control Valve INDUWA IMP Our Standard Central Control Valve Your advantages: Versatile, conversion to other system types easy and possible retroactively Excellent performance values - low pressure loss Insensitive to dirt, also used in dirt filtration Protection filter - which is usually necessary - not needed in most cases Corrosion-resistant against almost all chemicals Single systems expandable to double-tank-system without problem Illuminated display indicating either current flow rate, time, or remaining capacity Divers regeneration options, e.g. iediate, water-meter-controlled regeneration with motor valve (available for retrofitting) to avoid hard water in the system Self-learning microprocessor control for optimized regeneration Up to 9 different regeneration cycles prograable, with free choice of duration and sequence Time-controlled systems can be easily converted to time-/water-meter-controlled systems Chlorine cell for optimal system hygiene easily available for retrofitting Optional upflow regeneration, also available for retrofitting History data available for diagnosis (water amount, number of regenerations, etc.) Prograing lockable, i.e. protection against unauthorized access Same control also with double-tank-valve and 1 ¼ / 1 ½ / 2 valves Valve labels also available with your individual lettering and logo And many more Option of model with special control IMP Pro and chlorine cell Alarm message with external contact in case of salt deficiency Alarm message with external contact in case of deficient regeneration via injector blockage or control-piston-blockage Service reminder prograable after pre-selectable time period or after certain amount of water Display information available in English, German, Italian, Spanish, French If forced regeneration after 4 days according to DVGW-guidelines (only for upflow regeneration) is active, proportional salting is activated depending on previously used amount of water, i.e minimal salt consumption with optimal hygiene Diverse relay exits, e.g. after pre-selectable amount of water etc. And many more

SOFTENING SYSTEMS - SUPPLIES System Controller For individual central control of multiple single systems with INDUWA central control valves - Ideal for strongly fluctuating water usage - For ion-exchangers and filter systems - Existing systems are expandable retroactively without problem - Universally applicable for INDUWA valves IMP and IMP Pro (with chlorine cell) - For valve sizes 1, 1 ¼, 1 ½ and 2 Control possibilities: Progressive flow rate Automatic activation and deactivation of up to 6 single water-meter-controlled entities according to the current flow rate. (Single system regeneration after depletion.) Alternating service Switches two water-meter-controlled single systems alternately (shuttle service). Chance service Up to 6 single water-meter-controlled systems are in service at the same time, unless they regenerate via water-meter-control. (Only one system can regenerate at the same time.) Serial service Up to 6 systems, either individually or collectively water-meter-controlled, regenerate consecutively after automatic initiation. (Only one system can regenerate at the same time.)