PRAHER PLC-MP AQUASTAR MANAUL 2009

Similar documents
Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Easy Nest Kits. Installation Suggestions

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

New AQF Filter Polymer Filtration System

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Installation and Operating Instructions Bypass Flow Meter DST

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

USER MANUAL. JET TST and JET TST S.

Installation and commissioning instructions 255 series and 256 series

Installation and Operating Manual

Vessel Installation and Operating Manual

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Spirax Compact FREME Flash Recovery Energy Management Equipment

Safety instructions and operating manual

Declaration of Conformity as per Directive 97/23/EC

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Siphon vessel / Priming aid

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

GAS FUEL VALVE FORM AGV5 OM 8-03

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

SEMEM3-73 Maintaining medical gas pipeline systems and equipment

Airbrush Diaphragm Compressor AS06

Pressure maintenance valve SDV-P / SDV-P-E

Operating and maintenance manual Filter and reducing station Series / 1.0

)RU FHUWLILHG FRPSDQLHV ROTEX 509 +HDWLQJ FLUFXLW GLVWULEXWRU 2SHUDWLQJ LQVWUXFWLRQV

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Manual Actuated Boiler Blowdown Valves

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

R E D I C O N T R O L S

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

CAST IRON SAFETY VALVE TYPE 6301

Instrument Operating Manual

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Magnetic level switch type MR783 Instruction Manual

Type BBS-03, BBS-05, BBS-06, BBS-25

Gemini Owner s Manual

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

INSTALLATION & MAINTENANCE INSTRUCTION

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

Suction lance SLP / SLP Operating instructions SLP Manufacturer: Keep the operating instructions for future use!

1 DRIVE INDUSTRIAL IMPACT WRENCH

Operating Instructions in accordance with the Machines Directive 2006/42/EC

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

GM Series Dual-Block Multi-Function Gas Control Valves

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Operating Instructions Temperature Measuring System MF420-5T-100

Booster Pump PB4-60 Replacement Kits

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Operation Manual Airbrush Compressor AS196A ARTICLE 34207

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Instruction Manual Contact Pressure Vacuum Gauge

Air operated valve. VGA342R Series

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

INSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION

Angled Sign Light with Shade

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Budget Range Operators Handbook

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

OPERATION MANUAL PNEUMATIC VALVES

TITAN FLOW CONTROL, INC.

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Operation Manual ARTICEL SunSun CUF SunSun CUF SunSun CUF-6000

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

INTENDED USE TECHNICAL SPECIFICATIONS

Operating instructions - Translation of the original -

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

INSTALLATION OPERATION MAINTENANCE

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Official Journal of the European Union L 92/3

Operation Manual. Hand tool for AMP DUOPLUG Customer Manual PN: en (Translation of the original German version)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

12 Inch Barn Light. Owner s Manual

Sand Dollar Filter Owner s Manual IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Operating Manual. Diaphragm Seals Models , 107, , 207,

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

SAFETY PRECAUTIONS FOR THE BLACK BEARD S BEACH WATER PARK

Transcription:

PRAHER PLC-MP AQUASTAR MANAUL 2009 1. Copyrights This Operating Manual contains copyright-protected information. All rights reserved to Praher Kunststofftechnik GmbH. This Operating Manual is designed to use by operating personnel. Copying, reproduction or translation of the present document into other languages in whole or in part is subject to express written permission by Praher Kunststofftechnik GmbH. 2006PRAHERKunststofftechnikGmbH This Operating Manual has been specifically designed to be read, understood and complied within every respect by the person responsible for operating of the Aqua star Knowledge of the instruction contained in this Operating Manual is indispensable for preventing failure and ensuring faultless operating of the Aqua star. Therefore, it is essential that the person in charge of operating the equipment are familiar with the present documentation. 2. Introduction to operation manual This Operating Manual is intended to facilitate familiarization with the Aqua star and utilization of the same for the intended purpose. This Operating Manual contains important information for safe, proper and economical Operation of the Aquastar.Compliance with these instructions will contribute to, - preventing danger, - reducing repair costs and equipment failure, and - increasing the liability and service life of the Aqua star This Operating Manual supplements the instruction provided by existing accident prevention and environmental protection regulations. It must be available at the place of utilization of the equipment at any time and must be read by each person intending to use the Aqua star.this means - operating, including - Correction measures in case of faulty operation and - Maintenance In addition to the Operating Manual and the compulsory accident prevention regulations applicable at the place of utilization of the equipment, the generally recognize subject specific and technical rules must be taken into account. 3 Warranty and liability Warranty and liability claims in the context of damage to person or property shall be excluded where such damage results from one or several of the causes listed below. Improper use of the Aqua star Improper installation, putting into operation, operation and maintenance of the Aqua star Operation of the Aqua star with defective safety devices or improperly mounted or non-functional safety and protective devices.

Non-compliance with the instruction contained in the Operation Manual for Installation, putting into operation, operation and maintenance of the Aqua star Unauthorized modification of the Aqua star Insufficient monitoring of components subject to wear and tear inadequately performed repair of the Aqua star Damage of the Aqua star resulting from foreign matter or Force Majeure Enduring damage due to neglect of the Operating Manual or due to damaging sealed parts lead to a lapse of the warranty. We do not take an liability for thus resulting damages! Please read the Operating Manual carefully before starting. GB 4. Instruction for safety at work Each person involved in the user s facility, in the installation, dismantling, putting into operation, operation or maintenance of the Aqua star must have read and understood the entire Operating Manual and, in particular, the chapter Safety instructions. The instruction and warning signs calling attention to dangers must be taken into account Dangerous voltage This is for your own safety 5. Safety instructions This equipment has been built and examined according to safety precaution for electronic devices and has left the plant in a perfect safety-related condition. To keep this status and to guarantee a safe operating, the user must observe the safety instructions, which are included in these operating instructions. This installation work may only be undertaken by an authorized and licensed installer or electrical business. The electrical installations must be carried out according to the respective local and regional regulations (e.g. OEVE, VDE,...) and possible official regulations. The electrical connection must have seperating device built into the permanently installed electrical installation, which enables the disconnection of all electrical contacts with a contact space of minimum 3 mm from the mains. Pay attention that the supply voltage is correctly protected and an earthleakage circuit breaker < 30 ma is installed. Only use the equipment in dry rooms, in which no combustible gases and vapors are present. Do not operate the equipment immediately if it has been taken from a cold into a warm area. The thereby developing condensation water could destroy your equipment If the equipment has visible damages doesn t work anymore or has been stored for a longer periods under adverse conditions then it is to be expected that a safe operation is not possible anymore.

In this case the equipment is to be secured against unintentional start-up and if necessary to be decommissioned. Live parts can be uncovered when opening the cover or removing parts. Before an alignment, maintenance, a repair or a change of parts or devices, the equipment must be separated from all voltage supplies, if opening the equipment is necessary. If after that an alignment, maintenance or a repair on the opened equipment under voltage is inevitable, it may only be done by experienced skilled personnel, who have knowledge of the associated dangers and/or the relevant regulations. Capacitors in the equipment can be still charged, even if the equipment is separated from all voltage supplies. Assembly and/or disassembly of the armature only in a pressure-free status (i.e. empty piping beforehand). Armature flow and/or direction or flow must be considered. Each person involved in the operation and maintenance of the equipment must have read and understood the present Operating Manual This is for your own safety! 6. Residual Risk 6.1 Hazard generated by current Manipulation of the Aqua star by operating personnel is strictly prohibited and may only be performed by duly authorized personnel qualified for electrical work. Compliance with the corresponding instruction and prohibition signs is required. 6.2 Hazard generated by human error The operating personnel must be instructed with regard to the residual danger from electricity and familiarized with correct operation. Efficiency of the safety training must be verified. 6.3 Hazard generated by current during cleaning work Cleaning of the Aqua star may only be performed after disconnection from the power supply (level switch). 7. General PRAHER Aqua star controls are significant technical products, which are manufactured with high accuracy to the most modern technical production methods. Entitled complaints will naturally be rectified as far as possible if they occur. The equipment has a warranty after valid European right. The warranty begins on the purchase date. ATTENTION! For the discharge of the seal the valve stands on an Intermediate position and is not tight! Before use the electric drive must be

8. Assembly Device installation - installation of the valve: Install the valve into the piping system according to the labeling and the sketch below. Use GB Adapter unions. Threaded connections should be sealed only with Teflon tape. Although the device works in any position, it should not be mounted actuator down, if possible. If the difference in level between system and tank exceeds 3 meters, stop valves or non-return valves (check valves) should be installed to prevent severe damage to the actuator and the valve due to excessive pressure and flow. Install flow reducing valves in the backwash line in order to prevent sand wash out.. Otherwise a stuck valve diverter can adversely affect the flawless functioning of the Aqua star. Polluted or grainy filtering media require the use of adequate pre-filters or strainers. IMPORTANT! The PUMP must be SHUT OFF during actuator travel between positions!! 8.1 Function and installation pump I FILTER II WASTE filter top Filtration of medium (i.e. Water) filter top drain Pool Pump Valve (to filter) Valve (from filter) Pool pump drain Drainlage of with pump Pool Pump Valve Drain III Pump CLOSED filter top drain No circulation. Do not operate pump Pool Pump Valve IV pump BACKWASH filter top drain Cleaning up filter medium (i.e. Sand) in upstream (reversed flow in filter) Pool Pump Valve (from filter) Filter Valve (to filter) Waste V RECIRCULATE filter top pump drain Recirculation of fluid without filter (Bypass filter) Pool Pump Valve Pool VI RINSE Cleaning of filter medium filter top (i.e. Sand) after backwash pump drain Pool Pump Valve (to filter) Filter Valve (from filter) Waste 6-way valve type: 1,5, 2 and 3 Connections : Thread or stick (all connectors open) Max. Operating pressure : ABS 1,5,2 and 3" 3,5 GFK 1,5,2 6 bar GFK 3 5 bar bar Pump from pump Top to the filter Bottom from filter Return to the Waste to the drain

9. Wiring diagram motor S1.. Limit switch CLOSED S2.. Limit switch FILTER S3.. Limit switch BACKWASH S4.. Limit switch RINSE S5.. Limit switch WASTE S6.. Limit switch PUMP S7.. Limit switch RECIRCULATE Travel times in seconds filter- backwash:40 backwash- rinse:30 rinse filter :22 filter drain: 22 motor only 3" valve 6 3 1 7 5 2 4 8 24 / 230V AC U~ 50/60Hz Power supply for pump 24/230 VAC 50/60Hz 0,5A Pump Attention: Only one position can be triggered, for example "FILTER" or "BACKWASH" but not "FILTER" and "BACKWASH" together! Technical Data: Operating voltage: 24 / 230 VAC 50 / 60 Hz Max. operating power during change over:11,5,2-11va/3-22va Type of protection: IP 65

10. Exploded drawing 10.1 Aqua star MP6 1 1/2 230/24V 1 2 4x 8 4x 3 1 3 9 4x 10 4 11 4x 5 11 6x 6 12 7 1. Inspection glass + O-Ring 2. Cover for Aqua star 3. Screw 4. Emergency handle 5. 1 1/2 valve cover 6. O-ring 7. 1 1/2 valve 8. circuit board 9. Pump limit switch 10. Motor 11. O-Rings-diverter 12. Valve diverter 13. cover gasket

10.2 Aquastar MP6 2 230/24V 1 8 4x 4x 3 2 1 3 4x 9 10 4 11 4x 5 10x 11 6 12 1. inspection glass + O-ring 2. cover for Aqua star 7 3. screw 4. emergency handle 5. 2 valve cover 6. O-ring 7. 2 valve 8. circuit board 9. pump limit switch 10. motor 11. O-Rings 12. valve diverter 13. cover gasket

10.3 Aquastar MP6 3 230/24V GB 8 4x 4x 1 2 3 1 3 9 4x 10 10 4x 11 4 11 6x 5 12 14x 6 7 1. inspection glass + O-ring 2. cover for Aqua star 3. screw 4. emergency handle 5. 3 valve cover 6. O-ring 7. 3 valve 8. circuit board 9. pump limit switch 10. motor 11. O-Rings 12. Valve diverter 13. cover gasket

11. Emergency manual override Operating with power failure or control system problems 1. Before any use of the hand emergency, seperate valve from the electric circuit - interrupt control cables to the valve. 2. Lower system pressure in the valve (switch pump off, take care of possibly existing water pillars and close ball valve). 3. Operation of the manual emergency see sketch Note: Before any emergency operation the system pressure of the valve must be lowered The hand emergency operation is not meant to replace the electrical drive. To ensure a longstanding function of the hand emergency operation, this should be continuously used. 11.1 Dismantling

11.2 Installation GB 23