HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

Similar documents
HYDRAULIC MOTORS MV APPLICATION GENERAL

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

DISC VALVE HYDRAULIC MOTORS

DISC VALVE HYDRAULIC MOTORS

OMS Technical Information Technical data

OMS Technical Information. Versions OMS. Versions

HYDRAULIC MOTORS MM APPLICATION CONTENTS GENERAL MOTORS

HYDRAULIC MOTORS MR APPLICATION GENERAL

HYDRAULIC MOTORS MR APPLICATION GENERAL

OMS, OMT and OMV Orbital Motors. Technical Information

Orbital Motors Type OMP X and OMR X

OMS, OMT and OMV Orbital Motors. Technical Information

Orbital Motors OMS, OMT and OMV

Orbital Motors Type OMP, OMR and OMH. Technical Information

Fixed Displacement Motor A4FM

HYDRAULIC MOTORS MS APPLICATION CONTENTS OPTIONS GENERAL. » Conveyors. » Model- Disc valve, roll-gerotor 80,5 564,9 [ ] Max.

HYDRAULIC MOTORS MS APPLICATION CONTENTS OPTIONS GENERAL. » Agriculture machines »»»» Special vehicles etc. » Model- Disc valve, roll-gerotor

APPLICATION»» Conveyors Metal working machines» Agricultural machines Road building machines Mining machinery Food industries Special vehicles etc.

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Fixed Displacement Plug-In Motor A2FE

Fixed Displacement Motor A4FM

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

PVQ 13 A2 R SE 1 S 20 C-11 D

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

MAKING MODERN LIVING POSSIBLE. Technical Information. Orbital Motor VMP. powersolutions.danfoss.com

Orbital Motors OMSW with brake nose

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Orbital Motors Type VMP. Technical Information

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

DENISON HYDRAULICS T6 industrial application

DENISON HYDRAULICS high performance hydraulic vane pumps single, double, triple T7 and T67 industrial application

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Variable Displacement Pump A10VO

HYDROSTATIC STEERING UNITS AND ACCESSORIES

PLD 03 T A CASAPPA S.p.A.

420 Mobile Piston Pump Design Code B

Pressure reducing valve, pilot operated, Model 3DR

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Pressure reducing valve, direct operated

RCOe 1806/ PARKER CALZONI Radial Piston Motor Type MR, MRE

PVK OPEN LOOP PUMPS. Bulletin E

Axial piston pumps type PVC

Axial piston pumps type PVC

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Directional Controls

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

Pressure reducing valve, direct operated

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

GEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Introduction INDEX. INTRODUCTION HSE

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Axial Piston Variable Pump A10V(S)O (US-Version)

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

MECHANICALLY OPERATED DIRECTIONAL VALVES Rotary Type : DRT/DRG-02 Cam Operated : DCT/DCG-01, 03 Threaded Connection/Sub-plate Mounting

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Cooler-Bypass Thermostat Valve, Size 16

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

Axial piston-variable motor A10VM Plug-in version A10VE

Directional Controls

PRESSURE SEQUENCE VALVE TYPE UZK

Full Range Pressure Compensating Variable Flow Control

directional control valve series cv691

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

Pilot Operated Check Valves

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

Pressure relief valve, direct operated

Industrial Hydraulic Pumps T6EDC. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

Directional Control Valves Technical Information Model 1500

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Cover headline. Cover subheadline. Check Valves

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Check valve hydraulically pilot operated

Monoblock directional control valves ML - Directional control valve

005 Series Modular Valves

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Pressure relief valve, direct operated

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

SDM to 8 sections monoblock valve D1WWDA02A

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

420 Mobile Piston Pump Design Code B

Monoblock Directional Control Valve RMB 202

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

Variable displacement vane pump (with mechanical pressure compensator)

HIGH PRESSURE DRILLING FLUID PUMP

Pressure relief valve, direct operated Type DBD

Transcription:

HYDRAULIC OORS APPLICAION» Skid Steer Loaders» etal working machines» renchers» Augers» Agricultural machines» Road building machines» Special vehicles» ine machines» Woodworking and sawmill machinery» Conveyors etc. CONENS Specification data... 18 Function diagrams... 19 21 Dimensions and mounting... 22 24 Shaft extensions... Permissible shaft loads... Dimensions and mounting- V... 26 Dimensions and mounting- 6V... 27 Internal Spline data... 28 Order code... 28 GENERAL A B OPIONS A B» odel - Disc valve, roll-gerotor» Flange with wheel mount» Short motor» Side ports» Shafts - straight, splined and tapered» BSPP ports;» Other special features. EXCELLENCE» High torque and pressure drop» High inlet pressure» High starting torque» Improved efficiency at high pressure drop» Smooth operation at low speed ax. Displacement, ax. Speed, ax. orque, ax. Output, ax. Pressure Drop, ax. Oil Flow, in. Speed, cm /rev [in /rev] [RP] danm [ lb-in] kw [HP] bar [PSI] lpm [GP] [RP] Permissible Shaft Loads dan [lbs] Pressure fluid O O emperature range, C [ F] 2 Optimal Viscosity range, mm /s [SUS] Filtration 724,3 [ 44.2] 75 cont.: 183 [ 162] int.: 229 [227] 7 [94] cont.: [ 36] int.: 35 [58] 15 [4] 5 P= 1 [ 2] a ineral based- HLP(DIN 51524) or H(ISO 6743/4) -4 14 [-4 284] 2 75 [ 98 347] ISO code 2/16 (in. recommended fluid filtration of micron s) Oil flow in drain line Pressure Losses Pressure drop bar [ PSI] 14 [ 23] 21 [ 345] Viscosity Oil flow in drain line 2 mm /s [ SUS] lpm [ GP] 2 [ 98] 35 [ 164] 2 [ 98] 35 [ 164] 2,5 [.66] 1,5 [.396] 5 [ 1.321] 3 [.793] 35 3 2 15 1 5 2 15 1 5 5 75 1 1 Q, lpm 5 1 15 2 3 Q, GP 17

OORS SPECIFICAION DAA ype 2 315 4 47 5 63 7 Displacement, cm /rev [ in /rev] ax. Speed, [RP] 21,4 [ 12.29] 6 75 1,8 [ 15.36] 5 6 326,3 [ 19.9] 38 46 41,9 [.6] 35 365 475 [ 28.97] 26 315 523,6 [ 31.95] 24 285 631, 2 [ 38. 52] 19 23 724 [ 44.2] 17 215 ax. orque 72 [ 6375] 9 [ 7965] 116 [ 1265] 147 [ 131] 171 [ 15135] 172 [ 152] 183 [ 162] 16[ 1416] danm [ lb-in] Peak** 12 [ 93] 128 [ 1133] 163 [ 144] 26 [ 18232] 215 [ 163] 215[163] 229 [ 227] 192[ 17] 115 [ 118] 144 [ 12745] 186 [ 1646] 235 [ 28] 24 [ 2124] 24 [ 2124] 274 [ 24] 24 [ 2124] ax. Output kw [ HP] ax. Pressure Drop bar [ PSI] ax. Oil Flow Peak** 41 [ 55] 7 [94] [ 36] 35 [ 58] 4 [ 58] 1 [ 33] 41 [55] 7 [ 94] [36] 35[58] 4[58] 1[33] 41 [55] 7 [94] [36] 35[58] 4[58] 1[33] 41 [55] 7 [94] [36] 35[58] 4[58] 1[33] 41 [55] 55 [ 74] [36] 315 [ 457] 35 [ 58] 1[33] 37,5 [ 5] 51 [ 68] 23 [ 334] 28 [ 46] 32 [ 464] 1[33] 28 [ 37,5] 42 [ 56] 2[ 29] [ 36] 3[ 435] 1[33] 26 [ 35] 4 [ 54] 16 [ 232] 21[ 345] 26[ 377] 1[33] lpm [ GP] 15 [ 4] 15[4] 15[4] 15[4] 15[4] 15[4] 15[4] 15[4] ax. Inlet Pressure bar [ PSI] ax. Return Pressure Peak** 27 [ 392] 37 [ 537] 42 [ 61] -1 RP 75 [11] 27[392] 37[537] 42[61] 75 [11] 27[392] 37[537] 42[61] 75 [11] 27[392] 37[537] 42[61] 75 [11] 27[392] 37[537] 42[61] 75 [11] 27[392] 37[537] 42[61] 75 [11] 27[392] 37[537] 42[61] 75 [11] 27[392] 37[537] 42[61] 75 [11] without Drain Line or 1-3 RP 4 [58] 4 [58] 4 [58] 4 [58] 4 [58] 4 [58] 4 [58] 4 [58] ax. Pressure >3 RP 2 [29] 2 [29] 2 [29] 2 [29] 2 [29] - - - in Drain Line, bar [ PSI] -max. RP 75 [11] 75 [11] 75 [11] 75 [11] 75 [11] 75 [11] 75 [11] 75 [11] ax. Return Pressure with Drain Line bar [ PSI] Peak** 14 [ 2] 14 [ 2] 14 [ 2] 14 [ 2] 175 [ ] 175 [ ] 175 [ ] 175 [ ] 21 [ 3] 21 [ 3] 21 [ 3] 21 [ 3] 14 [ 2] 14 [ 2] 14 [ 2] 14 [ 2] 175 [ ] 175 [ ] 175 [ ] 175 [ ] 21 [ 3] 21 [ 3] 21 [ 3] 21 [ 3] ax. Starting Pressure with Unloaded Shaft, bar [ PSI] 6 [9] 6 [9] 6 [9] 6 [9] 6 [9] 6 [9] 6 [ 9] 6 [ 9] in. Starting orque danm [ lb-in] 6 [ 531] 75 [ 664] 97 [ 8585] 122 [ 18] 142 [ 17] 143 [ 12655] 145 [ 1283] 148[ 131] in. Speed***, [RP] 5 5 5 5 5 5 5 5 Weight, kg [ lb] 26,9 [ 59.3] 27,3 [ 6.2] 28,1 [ 62] 29 [ 64] 29,7 [ 65.5] 3,2 [ 66.6] 29, 7 [ 65. 5] 31 [ 68.4] W 27,4 [ 6.4] 27,8 [ 61.3] 28,6 [ 63.1] 29,5 [ 65.1] 3,2 [ 66.6] 3,7 [ 67.7] 3, 2 [ 66.6] 31,5 [ 69.5] V 15,7 [ 34. 6] 16,1 [ 35. 5] 16,9 [ 37.3] 17,8 [ 39.3] 18,5 [ 4.8] 19 [ 41.9] 18,5 [ 4.8] 19,8 [ 43.7] * Intermittent operation: the permissible values may occur for max. 1% of every minute. ** Peak load: the permissible values may occur for max. 1% of every minute. *** For speeds lower than given, consult factory or your regional manager. 1. Intermittent speed and intermittent pressure must not occur simultaneously. 2. Recommended filtration is per ISO cleanliness code 2/16. A nominal filtration of micron or better. 3. Recommend using a premium quality, anti-wear type mineral based hydraulic oil, HLP(DIN51524) or H(ISO6743/4). If using synthetic fluids consult the factory for alternative seal materials. 4. Recommended minimum oil viscosity 7 SUS [13 mm²/s] at 5 C [122 F]. 5. Recommended maximum system operating temperature is 82 C [18 F]. 6. o assure optimum motor life fill with fluid prior to loading and run at moderate load and speed for 1-15 minutes. 18

OORS FUNCION DIAGRAS lb-in 12 danm 14 Q=1 l/min 2.65 GP 2 l/min 5.3 GP 4 l/min 1.6 GP 6 l/min 15.85 GP 8 l/min 21.2 GP 1 l/min 26.4 GP 1 l/min 33 GP 15 l/min 39.6 GP 1 8 6 4 2 12 1 8 6 4 2 cont. int. N=2,5 kw 1 kw 5 kw 2 kw 4 kw 3 kw 85% t=86% 83% 8% 6 kw 5 kw 78% cont. 7% 75% 6% int. p=35 bar 575 PSI 3 bar 4715 PSI 3 bar 435 PSI 275 bar 399 PSI bar 36 PSI 2 bar 3265 PSI 2 bar 29 PSI 16 bar 232 PSI 12 bar 174 PSI 8 bar 116 PSI 4 bar 58 PSI n -1 5 1 15 2 5 4 45 5 55 6 min (rpm) 315 lb-in 16 danm 175 Q=1 l/min 2.65 GP 2 l/min 5.3 GP 4 l/min 1.6 GP 6 l/min 15.85 GP 8 l/min 21.2 GP 1 l/min 26.4 GP 1 l/min 33 GP 15 l/min 39.6 GP 14 12 1 8 6 4 2 15 1 1 75 5 cont. int. 5 kw N=2,5 kw 1 kw 2 kw t=88% 87% 5 kw 4 kw 85% 83% 3 kw -1 5 1 15 2 5 4 45 5 min (rpm) cont. 8% 75% 7% 6% he function diagrams data was collected at back pressure 5 1 bar (72.5PSI 145PSI) O and oil with viscosity of 32 mm²/s [15SUS] at 5 C [122 F]. int. p=35 bar 575 PSI 3 bar 4715 PSI 3 bar 435 PSI 275 bar 399 PSI bar 36 PSI 2 bar 3265 PSI 2 bar 29 PSI 16 bar 232 PSI 12 bar 174 PSI 8 bar 116 PSI 4 bar 58 PSI n 19

OORS FUNCION DIAGRAS 4 lb-in 2 danm 2 Q=1 l/min 2.65 GP 2 l/min 5.3 GP 4 l/min 1.6 GP 6 l/min 15.85 GP 8 l/min 21.2 GP 1 l/min 26.4 GP 1 l/min 33 GP 15 l/min 39.6 GP 18 16 14 12 1 8 6 4 2 2 175 15 1 1 75 5 cont. int. 6 kw 4 kw 5 kw 3 kw t=87% 1 kw 2 kw 5 kw 86% 85% 78% N=2,5 kw 83% 8% 75% 7% 6% cont. int. p=35 bar 575 PSI 3 bar 4715 PSI 3 bar 435 PSI 275 bar 399 PSI bar 36 PSI 2 bar 3265 PSI 2 bar 29 PSI 16 bar 232 PSI 12 bar 174 PSI 8 bar 116 PSI 4 bar 58 PSI n -1 5 1 15 2 5 4 min (rpm) 47 lb-in 22 2 18 16 14 12 1 8 6 4 2 danm 2 2 175 15 1 1 75 5 cont. int. Q=1 l/min 2.65 GP 2 l/min 5.3 GP 5 kw 4 l/min 1.6 GP N=2,5 kw 6 l/min 1 kw 2 kw t=87% 15.85 GP 8 l/min 85% 21.2 GP 1 l/min 26.4 GP 3 kw 4 kw 83% 8% 1 l/min 33 GP 75% 5 kw cont. 78% 6% 15 l/min 39.6 GP 7% int. p=35 bar 575 PSI 3 bar 4715 PSI 3 bar 435 PSI 275 bar 399 PSI bar 36 PSI 2 bar 3265 PSI 2 bar 29 PSI 16 bar 232 PSI 12 bar 174 PSI 8 bar 116 PSI 4 bar 58 PSI n -1 5 1 15 2 5 min (rpm) he function diagrams data was collected at back pressure 5 1 bar (72.5PSI 145PSI) and oil with viscosity of 32 mm²/s [15SUS] at 5 C [122 O F]. 2

OORS FUNCION DIAGRAS 5 lb-in 2 18 16 14 12 1 8 6 4 2 danm 2 2 175 15 1 1 75 5 cont. int. Q=1 l/min 2.65 GP 2 l/min 5.3 GP 4 l/min N=2,5 kw 1.6 GP 1 kw 5 kw 6 l/min 15.85 GP 8 l/min 21.2 GP 2 kw 3 kw t=86% 83% 4 kw 5 kw -1 5 1 15 2 3 min (rpm) 1 l/min 26.4 GP 1 l/min cont. 33 GP 78% 75% 15 l/min 8% 7% 6% int. 39.6 GP p=3 bar 4715 PSI 3 bar 435 PSI 275 bar 399 PSI bar 36 PSI 2 bar 3265 PSI 2 bar 29 PSI 16 bar 232 PSI 12 bar 174 PSI 8 bar 116 PSI 4 bar 58 PSI n 63 lb-in 22 danm Q=1 l/min 2.65 GP 2 l/min 5.3 GP 4 l/min 1.6 GP 6 l/min 15.85 GP 8 l/min 21.2 GP 1 l/min 26.4 GP 1 l/min 33 GP 15 l/min 39.6 GP 2 18 16 14 12 1 8 6 4 2 2 2 175 15 1 1 75 5 cont. int. 1 kw N=2,5 kw 5 kw t=87% 85% 3 kw 4 kw 2 kw 78% 83% 8% 75% 7% 6% bar 36 PSI 2 bar 3265 PSI 2 bar 29 PSI 16 bar 232 PSI 12 bar 174 PSI 8 bar 116 PSI 4 bar 58 PSI cont. int. n -1 5 75 1 1 15 175 2 2 min (rpm) he function diagrams data was collected at back pressure 5 1 bar (72.5PSI 145PSI) and oil with viscosity of 32 mm²/s [15SUS] at 5 C [122 O F]. 21

OORS DIENSIONS AND OUNING DAA - and C K Shaft C,CO Shaft SH Shaft Shaft Dim. See Page K Shaft C,CO Shaft SH Shaft 4...4,4 [1.575...1.59] 82 [3.228] 82 [3.228] Flange Dim. See Page 24 3,8...31,2 [1.212...1.228] P (A,B) 21±,15 [.827±.59] 82 [3.228] 82 [3.228] 55,4 [2.181] 82,5 [3.248] max L L2 L1 max L L1 L2 42±,15 [1.653±.59] 42±,15 [1.653±.59] P (A,B) Port A F Port B - Drain port G1/4 +,4 ø21 [.827 +.157] F 139 12 [.472] 1 [.394] Warning: Drain line should always be used. 72 [2.834] Standard Rotation Port A Pressurized - CW Port B Pressurized - CCW Reverse Rotation Port A Pressurized - CCW Port B Pressurized - CW 22 P (A, B) : 2xG3/4-17 mm [.669 in] depth : G1/4-12 mm [.472 in] depth (plugged) ype L, mm [in] L, 2 mm [in] ype L, mm [in] L 2, mm [in] L, 1 mm [in] 2 188 [ 7.4] 142,3[ 5.6] C 2 198 [ 7.79] 153 [ 6.2] [.98] 194 [ 7.64] 148,6 [ 5.85] 315 23 [ 7.99] 157,8 [ 6.21] C 24,5 [ 8.5] 159,3 [ 6.27] 31,3 [ 1.23] C 315 213,5 [ 8.4] 168,5 [ 6.63] 4,5 [ 1.59] 4 214 [ 8.43] 168,3 [ 6.63] 47 222 [ 8.74] 176,3 [ 6.94] 5 228 [ 8.98] 182,3 [ 7.18] 63 224 [ 8.82] 178,3 [ 7.2] 7 233 [ 9.17] 187,3 [ 7.37] C 4 C 47 C 5 C 63 C 7 224 [ 8.82] 232 [ 9.13] 238 [ 9.37] 234 [ 9.21] 243 [ 9.56] 179 [ 7.4] 187 [ 7.36] 193 [ 7.6] 189 [ 7.44] 198 [ 7.79] 51 [ 2.1] 59 [ 2.32] 65 [ 2.56] 61 [ 2.4] 7 [ 2.76] mm [in]

OORS DIENSIONS AND OUNING DAA - W K Shaft C, CO Shaft SH Shaft Shaft Dim. See Page 99,2...99,8 [3.95...3.929] 82 [3.228] 82 [3.228] Flange Dim. See Page 24 L3 L2 L1 Port Dim. See Page 22 max L P (A,B) Port A Port B Warning: Drain line should always be used. P (A, B) : 2xG3/4-17 mm [.669 in] depth : G1/4-12 mm [.472 in] depth (plugged) ype W 2 W W 315 W 4 W 47 W 5 W 63 W 7 L, mm [in] 129 [ 5.8] 135 [ 5.32] 144 [ 5.67] 155 [ 6.1] 163 [ 6.42] 169 [ 6.65] 165 [ 6.5] 174 [ 6.85] L, 1 mm [in] [.98] 31,3 [ 1.23] 4,5 [ 1.59] 51 [ 2.1] 59 [ 2.32] 65 [ 2.56] 61 [ 2.4] 7 [ 2.76] L, 2 mm [in] L, 3 mm [in] 83,8 [ 3.3] 111,1 [ 3.37] 9,1 [ 3.55] 117,4 [ 4.62] 99,3 [ 3.91] 126,6 [ 4.98] 19,8 [ 4.32] 137,1 [ 5.4] 117,8 [ 4.64] 145,1 [ 5.71] 123,8 [ 4.87] 151,1 [ 5.95] 119,8 [ 4.72] 147,1 [ 5.79] 128,8 [ 5.7] 156,1 [ 6.15] Standard Rotation Port A Pressurized - CW Port B Pressurized - CCW Reverse Rotation Port A Pressurized - CCW Port B Pressurized - CW mm [in] 23

OORS OUNING 4-Bolt flange spigot diameter ø16 mm [6.3 in] - BC ø2 [7.874 in] mm 4xø18±,15 [.78±.59] ø2±,4 [7.874±.157] 9 [.354] 4,2 [1.582] C 4-Bolt flange spigot diameter ø1 mm [4.921 in] - BC ø16 mm [6.3 in] 4xø14 +,3 +,1 +.39 [.551 +.118] ø16±,4 [6.3±.157] R16 [.63] 9±,5 [.354±.197] 21±,5 [.827±.197] W 4-Bolt flange, Wheel otor spigot diameter ø16 mm [6.3 in] - BC ø2 mm [7.874 in] 4xø18±,15 [.78±.59] ø2±,4 [7.874±.157] 7 [.275] 42 [1.653] 18 [7.86] ø172 -,63 [6.772 ] -. ø1 -,1 [4.921 ] -.39 ø16 -,63 [6.299 ] -. 147 [5.787] ø1 -,1 -,5 -.4 -.19 [4.921 ] 18 [7.86] ø98±,5 [3.858±.197] ø16 -,63 [6.299 ] -. 24 [.945] 4 21 [.157] [.827] mm [in] 24

OORS C - ø4 straight, Parallel key A12x8x7 DIN 6885 ax. orque 132,8 danm [11755 lb-in] SHAF EXENSIONS SH - ø1½" splined 17, DP 12/24 ANSI B92.1-1976 ax. orque 132,8 danm [11755 lb-in] R2±,2 [.787±.78] 45 R2±,2 [.787±.78] R2±,2 [.787±.78] 45 R2±,2 [.787±.78] Pitch 12/24 eeth 17 Pressure angle 3 12 -,43 [.472-.17] 82-,2 [3.228 ] -.79 5:1 82-,2 [3.228 ] -.79 ø5 [1.968] ø4 +,18 -,2 +.7 -.1 [1.575 ] ø5 [1.968] 12 min [.984] Deep 12 min [.984] Deep 56 [2.] K - tapered 1:1, Parallel key B12x8x28 DIN 6885 ax. orque 21,7 danm [1865 lb-in] ø5 [1.968] 82-,2 [3.228 -.79] 4 B [.157] 6 [.236] 3x2 ø56 [2.] 12 +,1 -,5 [.472 +.4 -.19 ] B-B 54±,4 [2.126±.157] aper 1:1 B ø6 [.236] S=46 ightening orque 5±3 danm [44±265 lb-in] 16,15-,2 43 -,2 [1.693 ] -.79 ø38,1-, [1.5 ] -.1 -ø1½" straight, Parallel key 3 "x 3 CO 8 8 "x 2¼" BS46 ax. orque 132,8 danm [11755 lb-in] R2±,2 [.787±.78] 9.545 -,2 [.379 ] -.8 45 R2±,2 [.787±.78] 82-,2 [3.228 ] -.79 42,4 -,2 [1.669 ] -.79 3/8-16 UNC min [.984] deep ø5 [1.968] ø38,1-,5 [1.5 ] -.19 [.634 ] -.79 mm [in] PERISSIBLE SHAF LOADS he curves apply to a B1 bearing life (ISO281) of 2 hours at 2 RP. Pr Pr lbs dan 56 12 5 Pr Pr lbs dan 56 12 5 C 1 4 8 1 4 8 3 6 3 6 2 4 2 4 2 1 2 1-8 -6-4 -2 2 4 6 8 1 12 14 16 mm -8-6 -4-2 2 4 6 8 1 12 14 16 mm -3-2 -1 1 2 3 4 5 6 7 in Pr Pr lbs dan 56 12 5 1 4 8 3 6 2 4 2 1 W -3-2 -1 1 2 3 4 5 6 in -8-6 -4-2 2 4 6 8 1 12 14 16 mm -3-2 -1 1 2 3 4 5 6 7 in

OORS DIENSIONS AND OUNING DAA - V 45,6-1 [1.795 -.394] 14 max [.551] 21±,2 [.827±.78] ø11±,1 [4.33±.39] Port B 9x12 [5.472 ] -,2 -.79 84±,3 [3.37±.118] 139 Port A P (A,B) L3 L1 L2 max L 72 [2.834] P (A, B) mm [in] Warning: Drain line should always be used. : 2xG3/4-17 mm[.669 in] depth : G1/4 12 mm [.472 in] depth (plugged) Standard Rotation Port A Pressurized - CW Port B Pressurized - CCW Reverse Rotation Port A Pressurized - CCW Port B Pressurized - CW ype L, mm [in] L, 1 mm [in] V 2 151 [ 5.945] [.98] V 157 [ 6.181] 31,3 [ 1.23] V 315 167 [ 6.575] 4,5 [ 1.59] V 4 177 [ 6.968] V 47 185 [ 7.283] V 5 191 [ 7.52] V 63 187 [ 7.362] V 7 196 [ 7.717] 51 [ 2.1] 59 [ 2.32] 65 [ 2.56] 61 [2.4] 7 [2.76] L, 2 mm [in] L, 3 mm [in] 16,5 [ 4.193] 27,8 [ 1.94] 112,8 [ 4.441] 26,5 [ 1.43] 122, [ 4.83] 22,3 [.878] 132,5 [ 5.217] 21,8 [.858] 14,5 [ 5.531] 23,8 [.937] 146,5 [ 5.768] 27,8 [ 1.94] 142,5 [ 5.61] 21,8 [.858] 151,5 [ 5.965] 22,8 [.898] DIENSIONS OF HE AACHED COPONEN F +,5 47 +.197 [1.85 ] +,4 17 [.669 +.157] K 16DP 12/24 ANS B92.1-76 min ø55 [2.165] ø9 [3.543] J I F: Oil circulation hole J: 9x12-3 mm [1.181 in] depth, 4, ø11±,1 [4.33±.39] I: O- Ring 93x1,5mm [3.661x.59 in] : Drain connection G1/4 26

OORS DIENSIONS AND OUNING DAA - 6V 45,6-1 [1.795 -.394] 14 max [.551] 21±,2 [.827±.78] 4 1 ø11±,1 [4.33±.39] Port B -,2 -.79 [5.472 ] 84±,3 [3.37±.118] 6x12 2 2 139 Port A L3 L2 L1 max L P (A,B) 4 1 Fig.1 72 [2.834] mm [in] Warning: Drain line should always be used. P (A, B) : 2xG3/4-17 mm[.669 in] depth : G1/4 12 mm [.472 in] depth (plugged) Standard Rotation Port A Pressurized - CW Port B Pressurized - CCW Reverse Rotation Port A Pressurized - CCW Port B Pressurized - CW ype L, mm [in] L, 1 mm [in] 6V 2 151 [ 5.945] [.98] 6V 157 [ 6.181] 31,3 [ 1.23] 6V 315 167 [ 6.575] 4,5 [ 1.59] 6V 4 177 [ 6.968] 6V 47 185 [ 7.283] 6V 5 191 [ 7.52] 6V 63 187 [ 7.362] 6V 7 196 [ 7.717] 51 [ 2.1] 59 [ 2.32] 65 [ 2.56] 61 [2.4] 7 [2.76] L, 2 mm [in] L, 3 mm [in] 16,5 [ 4.193] 27,8 [ 1.94] 112,8 [ 4.441] 26,5 [ 1.43] 122, [ 4.83] 132,5 [ 5.217] 14,5 [ 5.531] 22,3 [.878] 21,8 [.858] 23,8 [.937] 146,5 [ 5.768] 27,8 [ 1.94] 142,5 [ 5.61] 21,8 [.858] 151,5 [ 5.965] 22,8 [.898] DIENSIONS OF HE AACHED COPONEN FOR 6V F +,5 47 +.197 [1.85 ] +,4 17 [.669 +.157] J K 16DP 12/24 ANS B92.1-76 min ø55 [2.165] ø9 [3.543] I F: Oil circulation hole J: 9x12-3 mm [1.181 in] depth, 4, ø11±,1 [4.33±.39] or 6x12-3 mm [1.181 in] depth, situated in accordance with the bolts 12, shown on Fig.1, ø11±,1 [4.33±.39] DRAIN CONNECION A drain line ought to be used when pressure in the return line can exceed the permissible pressure. It can be connected to the drain connection of the attached component. he maximum pressure in the drain line is limited by the attached component and its shaft seal. he drain line must be possible for oil to flow freely between motor and attached component and must be led to the tank. he maximum pressure in the drain line is limited by the attached component and its seal. 27 I: O- Ring 93x1,5mm [3.661x.59 in] : Drain connection G1/4

OORS INERNAL SPLINE DAA FOR HE AACHED COPONEN Standard ANS B92.1-1976, class 5 [m=2.1166; corrected x.m=+1,] Fillet Root Side Fit Number of eeth Diametral Pitch Pressure Angle Pitch Dia. ajor Dia. inor Dia. Circular Space Width Fillet Radius Dimension Between wo Pins Pin Dia. z DP D Dri Di Lo R L d inch mm 16 16 12/24 12/24 3 3 1.3333,8656 +,4 1.5118 1.5275 38,4 +,4 1.2657 1.2672,15.1763.1791 4,516±,37.2,5 +,1 1.63 1.59 26,9.1926.1934 4,835±,1 L Hardening Specification: HV=75±5 on the surface. HV=56 at,7±,2 [.35.19] case depth aterial: 2 ocr4 EN 184 or SAE862. ORDER CODE 1 2 3 4 5 6 7 Pos.1 - ounting Flange omit - 4-Bolt flange, spigot dia. ø16, BC ø2 C - 4-Bolt flange, spigot dia. ø1, BC ø16 W - Wheel motor V - Very short mount, 9x12 mounting bolts 6V - Very short mount, 6x12 mounting bolts Pos.2 - Displacement code 2-21,4 cm /rev [12.29 in /rev] - 1,8 cm /rev [15.36 in /rev] 315-326,3 cm /rev [19.9 in /rev] 4-41,9 cm /rev [.6 in /rev] 47-475, cm /rev [28.97 in /rev] 5-523,6 cm /rev [31.95 in /rev] 63-631,2 cm /rev [38. 52 in /rev] 7-724, 3 cm /rev [44.2 in /rev] Pos.3 - Shaft Extensions* C CO K SH - ø4 straight, Parallel key A12x8x7 DIN6885 - ø1½ straight, Parallel key / x / x2¼ BS46 - ø45 tapered 1:1, Parallel key B12x8x28 DIN6885 - ø1½" splined 17 ANSI B92.1-1976 Pos.4 - Check Valves omit - without check valves 1 - with check valves Pos.5 - Ports omit - BSPP (ISO 228) Pos.6 - Special Features (see page 48) Pos.7 - Design Series omit - Factory specified 8 8 NOES: * he permissible output torque for shafts must not be exceeded! he hydraulic motors are mangano-phosphatized as standard. 28