FLOW CALIBRATION RIG Mobile Calibration of In-line Flow Meters

Similar documents
PHARMA. Insatech Insacal and Insacal mk. II.

Improve Process Reliability

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

ISC40G(S) with external

C-Flow Coriolis Mass Flow Meters

Expert Hydrostatic Level Transmitters

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

General Accreditation Guidance. User checks and maintenance of laboratory balances

Online data sheet FLOWSIC30 GAS FLOW METERS

Drilling Efficiency Utilizing Coriolis Flow Technology

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

JOS 15 JOS 25 JOS 40. Manual and semiautomatic test benches from DN 25 to DN 40. Characteristics. Basic characteristics. Test bench using balances

Precision Mass Flow Meters / Controllers for Liquids and Gases

Cold-acclimatised pipelines

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

FPG8601 Force Balanced Piston Gauge

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

SV60 Safety valves. for use with steam, gas and liquids

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

Flow metering in gases Introduction to COMBIMASS family

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

SITRANS F C MASSFLO. MASS flowmeters Sensor type MASS MC1 DN 50 - DN 100. Manual, supplement *083R9505* Order no.: FDK:521H1145

AUTOMATIC HOSE TEST UNIT, TYPE SPU

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Thermal Mass Flow Controllers for High Accuracy Process Gas Applications

COMPANY TRICOR CORIOLIS MASS FLOW METERS

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Dead-weight tester High-pressure version Model CPB3800HP

Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

Improving distillation tower operation

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

CONTROL and INSTRUMENTATION

Ron Gibson, Senior Engineer Gary McCargar, Senior Engineer ONEOK Partners

Pure Process Latinoamerica S.A. de C.V. Distribuidor Exclusivo.

Technical Information Conducal CLY421

Service Calibration are you doing it properly?

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

TESTING BENCHES for watermeters

Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Vehicle- or rack-mounted liquefied gas meters, pump supplied

American made since 1954

K V A L I F I K. Our accreditation number: NAH /2015. Valid to:

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

Pneumatic high-pressure controller Model CPC7000

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Vehicle-mounted meters, pump supplied

Customer Responsibilities

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

Hydraulic pressure balance Model CPB5800

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

For the highest operational safety around the clock

deltaflowc deltaflowc Venturi or Probe

Valve test benches. Systems overview

Truck-mounted Mass Flow Metering for LPG Delivery

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Deadweight Tester / Pressure Balance High pressure up to 5,000 bar / 70,000 psi CPB5000-HP. Applications. Special features. Description. Rel.

Peak Biotech - Company & Product Presentation

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Hand-held pressure calibrator with integrated pump Model CPH6600

Flow Measurement SITRANS F C

Micro Motion 7812 Fiscal Gas Density Meter

Yokogawa Systems and PCI Training

Qi Litre Ultrasonic Cleaner

Differential Pressure Transmiter

Sales presentation. SITRANS P portfolio extension P310 P DS III P410

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Coriolis Mass Flow Meter

THERMAL MASS FLOW MEASUREMENT FOR GASES

Fisher DVI Desuperheater Venturi Inline

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

Model 130M Pneumatic Controller

Torque Tube TB300 Digital Transmitters

Company Profile.. About Sammi Machinery

Transcription:

FLOW CALIBRATION RIG Mobile Calibration of In-line Flow Meters People - Ideas - Solutions www.insatechpharma.com

The rig runs very well and swiftly finds the various set points. It means we are able to fit in more calibrations than before. Calibration Technician, Danish Pharmaceutical Company. 2

The Flow Calibration Rig Introduction The Insatech Flow Calibration Rig can be used to calibrate flow meters. The mobile calibration rig is easily maneuvered into the production area and allows calibration to be carried out in-line. The in-line calibration will eliminate costs from lost production and will save you hours on the calibration process. Furthermore the flow rig will minimize the risk of contamination by Active Process Ingredients (API). How it works After the rig is connected to the Unit Under Test (UUT) and a power supply, it is ready to calibrate. During calibration, water will be circulated through the flow meter as well as a master meter. The calibration rig uses highly accurate and stable Coriolis mass flow meters for exact measurements of the flow. The calibration can be skewed to target a flow range with more points to test this range more rigorously. Another added bonus of the in-line calibration is that you get a check of the total test loop, which eliminates uncertainties that could occur in the lab. Operation The Flow Calibration Rig has been developed with a special focus on the pharmaceutical industry. The user friendly and mobile rig is easily maneuvered into the production line where it can calibrate instruments in-line. The rig can be delivered with a traceable DANAK accreditation with an accuracy of < 0.3% of the measured value and covers a flow range from 5 to 40.000 kg/h at a temperature of up to 40 C. The rig is made with AISI 304 or AISI 316L materials and the piping is made from EN 1.4404/AISI 316L. This means, that cleaning can be performed according to industry practice and all wetted parts are CIP-able. Service and Support Maintenance is limited to a yearly inspection of critical parts, e. g. motor, pump, and the flow meter needs to be calibrated once a year. We can also offer training in the use of the Flow Calibration Rig as part of the delivery. If you choose to sign a service agreement with us, we will perform maintenance on the rig and ensure it functions correctly. Furthermore we will take responsibility for timely calibration of it. 3

MV006 10 mm TT TE 000 40.000 kg/h SG MV009 MV010 FE 002 FIC 500 4.500 kg/h MV007 MV008 FE 002 003 FV 50 500 kg/h MV011 FE 003 MV013 ½ FE 004 MV012 004 5 50 kg/h MV002 MV014 ½ SY PIT 5-40.000 kg/h MV003 MV Distance to floor: Min. 100 mm 4

INTRODUCTION A Tedious and Time Consuming Process Traditionally when calibrating your flow meter you would first need to remove it from the production line and then bring it to the calibration laboratory for validation. This is often a tedious and time consuming process and has a number of disadvantages. First of all the production is interrupted during the removal and replacement of the flow meter, and the replacement itself introduces some uncertainties in the readings, which are critical to a successful production. Furthermore you risk contamination by Active Process Ingredients (API) of both your production line and the surroundings. Maximizing Production Uptime and Cutting Costs With the Flow Calibration Rig from Insatech Pharma you will be able to validate Flow meters in line, eliminating the above mentioned disadvantages. The mobile rig is easily maneuvered to the flow meter that needs to be calibrated. After being connected to a power supply as well as to the pipework the rig is ready to calibrate. This will save you hours on the calibration process - maximizing production uptime, minimizing contamination risks and cutting costs to a bare minimum! 5

MV006 10 mm TT TE 000 40.000 kg/h SG MV009 MV010 FE 002 FIC 500 4.500 kg/h MV007 MV008 FE 002 003 FV 50 500 kg/h MV011 FE 003 MV013 ½ FE 004 MV012 004 5 50 kg/h MV002 MV014 ½ SY PIT 5-40.000 kg/h MV003 MV MV Distance to floor: Min. 100 mm 6

HOW IT WORKS Plug and Play Connection The Flow Calibration Rig works by connecting the rig to preinstalled flanged pipework on either side of the flow meter (Unit Under Test). This can be done using either flanges or Tri-clamps. Furthermore in order to gather data form the Unit Under Test (UUT) you need to connect it to the rig using ma, pulse or Foundation Fieldbus (FF-bus). Connecting the rig to the UUT is not unlike plug and play. Highly Accurate and Stable Calibration After being connected to the UUT and a power supply the calibration can begin. During the calibration, water from the rig s water tank is circulated through the flow meter as well as the Master Meter and the readings are then compared. The Flow Calibration Rig uses highly accurate and stable Coriolis mass flow meters for exact measurements of the flow. Skewed Distribution Helps Target Certain Flow Ranges Before calibration you can select any number of calibration points you need. The distribution of the calibration points can be skewed, which means that instead of a linear distribution you can target a flow range with more points. This is useful if you want to test e.g. the flow range you use the most. Readings from the UUT When connecting to the UUT via ma and Pulse the readings are only shown locally on the display. If the rig is connected via FF-bus the Flow Calibration Rig is able to sniff the FF values after which you can choose the UUT from a list. The FF-bus is not affected by this operation. Added Bonus: Check of the Total Test Loop As the rig is connected directly to the pipework you will get a check of the total test loop, which is made possible only under true production conditions. This means that any uncertainties created while reinstalling the flow meter after its verification are eliminated, as well as influences from inadequate straight pipework before and after the flow meter. Also the risk of contamination by Active Process Ingredients (API) is eliminated as the flow meter remains in the production string. 7

MV006 10 mm TT TE 000 40.000 kg/h SG MV009 MV010 FE 002 FIC 500 4.500 kg/h MV007 MV MV008 FE 002 003 FV 50 500 kg/h MV011 MV FE 003 MV013 MV ½ FE 004 MV012 004 5 50 kg/h MV002 MV014 ½ SY PIT 5-40.000 kg/h MV003 MV Distance to floor: Min. 100 mm 8

OPERATION The Flow Calibration Rig has been developed with special focus on operating costs, user friendliness, accuracy and documentation. Furthermore, the rig is a turn-key solution and is delivered tested and calibrated, ready for use. User Friendliness Connections, instruments, and handles are to the extent possible placed ergonomically correct and allowing operation from one side. Furthermore the software is designed with usability in mind making your operator s user experience easy and effective every time. During the calibration all results are presented on the Human Machine Interface (HMI) after each point of the calibration. Mobility The Calibration Rig is designed to be mobile and the wheels allow the rig to be moved to wherever it is needed. The compact design of the rig means it fits through standard industrial doors and elevators. Furthermore the rig can be lifted by crane using the supplied yoke. To facilitate easy attaching of straps to the yoke, lifting lugs can be mounted in each corner of the rig. Easy Cleaning The Flow Calibration Rig is built with materials that are AISI 304 or optionally AISI 316L. Flow meters are made from EN 1.4404/AISI 316L or C22, depending on flow. All piping is made from EN 1.4404/AISI 316L with a surface roughness better than Ra 0.8. This means that cleaning can be performed according to industry practice and all wetted parts are CIP-able (Cleaning-in-place). Specifications and Accuracy As a benchmark, the Flow Calibration Rig can calibrate a water flow ranging from 5 to 40,000 kg/h at a pressure of up to 5 bars and temperature of up to 40 C. Ambient temperature must be between +10 C and 40 C. The rig needs a power supply of 400 VAC, 16 A. Other design parameters can be specified. The Flow Calibration Rig can be delivered with a traceable DANAK accreditation with an accuracy of < 0.3 % of the measured value. Is the Standard Solution Insufficient? If the standard solution is insufficient for your specific use we can, as a pre-order, work out a User Requirements Specification (URS) in accordance with your requirements. Documentation from Basic to Full Validation Insatech documents the various components, the interaction between the components and the total delivery as agreed to with the customer. We work according to well recognized standards, e. g. Good Automation Manufacturing Practice (GAMP) and the rig is designed according to both the machinery directive and the low voltage directive. The extent of our documentation is as per agreement with the customer, and goes from the basic operations manual to full validation in accordance with common practice of the pharmaceutical industry. 9

TE MV006 10 mm TT 000 40.000 kg/h SG MV009 FE MV010 MV003 MV Distance to floor: Min. 100 mm 10

SERVICE AND SUPPORT Minimal Maintenance The Flow Calibration Rig is developed for pharmaceutical use and therefore easy maintenance and cleaning are of the essence and can be done according to industry standards. Maintenance is limited to a yearly inspection of critical parts, e. g. motor, pump, and the flow meter needs to be calibrated once a year. Maintenance and recommended spare parts may differ depending on the specifications, but will always be described in the delivered documentation. Service and Support is Readily Available We know that the after sales experience is important to you and your total product experience. This is why we have a well staffed service department ready to help you if challenges should arise. We perform repairs on location or at our workshop depending on what is most beneficial in the given situation. We also perform calibration on site as well as accredited calibration. The rig is built with standard components which makes spare parts easily obtainable. If you choose to sign a service agreement with us, we will perform maintenance on the rig and ensure it functions correctly. Furthermore we will take responsibility for timely calibration of it. Training The ever increasing complexity of measuring equipment makes proper training very useful. Insatech Pharma can offer equipment and application training either at your or our facilities. Furthermore the training will be targeted towards your various working situations ensuring that you get the highest benefit possible. 11

A TRUSTWORTHY AND COMPETENT PARTNER Over the years Insatech has become a trustworthy and competent partner, supplying technical solutions and giving advice to the process industry. We have great experience with the particular applications and high requirements for documentation in our primary market pharma, biotech, and food industry. Eng ine er in g n sig De Su nin g ducts Pro Train ing www.insatechpharma.com is or sio pp m t Co Docu 12 m e n t a ti o n m

OUR CUSTOMERS Our customers consist of a broad range of pharmaceutical production companies with both small and large capacity. Our main customers are Danish based, but our solutions have also reached diffent parts of Europe and South America. 13

MV006 10 mm TT TE 000 40.000 kg/h SG MV009 MV010 FE 002 FIC 500 4.500 kg/h MV007 MV008 008 FE 002 003 FV 50 500 kg/h MV011 FE 003 MV013 ½ FE 004 MV012 004 5 50 kg/h MV002 MV014 ½ SY PIT 5-40.000 kg/h MV003 MV Distance to floor: Min. 100 mm 14

WHAT WE DO At Insatech Pharma we develop, produce and sell products within the fields of measuring and calibration. Our products are highly customizable and we are certain that we can meet your User Requirements Specification (URS). We have, for example, delivered products with DANAK Accreditation, for use in hazardous areas (ATEX) as well as meeting Functional Safety requirements IEC 61508 and IEC 61511. If you want to know more please contact us and let us know what we can do for you. In addition to the Flow Calibration Rig you might be interested in the products below. Insacal and Insacacal mk. II The Insacal Conductivity Master is primarily used in the pharmaceutical industry to validate and accurately document conductivity sensors in-line. Insacal can be used for in-situ calibration in closed loop, weighing only 4 kg, it is easily transported and saves you hours on total calibration time. Insacal is cleanable for cleanroom use according to industry standards, all wetted parts are CIP (Cleaning-In-Place) and SIP-able (Steam-In-Place). It is calibrated under our accreditation CAL Reg. No. 484 issued by DANAK (Danish Accreditation and Metrology Fund). The Insacal is used by our customers and calibration technicians alike. Further product development and 20 years of experience has been pored into the Insacal mk. II providing you with the same handy instrument, but focuses on validating low conductivity, with intelligent software that aids decision making. Further the mk. II makes it possible to reach an uncertainty that is 4 times better than the 2% specified in United States Pharmacopeia (USP). Pressure Calibration Rig The Pressure Calibration Rig is the cost effective alternative to traditional calibration of transmitters in the laboratory. Use of the Pressure Calibration Rig eliminates costly transportation time between production and laboratory. It reduces calibration time to about half an hour while the accuracy of the in-situ calibration is increased to laboratory level. The rig is a plug and play solution: After being connected to the pressure gas, Unit Under Test (UUT) and a power supply, the rig is ready to calibrate. The highly accurate and stable pressure controller prevents over - and undershooting. The Pressure Calibration Rig, -1...20 Barg / 0...21 Barg has an accuracy of 0.2835 mbarg and 0.2838 mbara (K2) and assures one year stability of the calibration. The rig is build with materials that are AISI 304 or optionally AISI 316L which allows cleaning according to industry practice. Quantity Calibration Rig The Quantity Calibration Rig can be used for calibration of loading cells for level measurement equipment in e.g. production and fermentation tanks, by dispersing a pre-defined batch of fluid on the basis of volume or weight. The calibration is highly accurate and stable, the skewed distribution of calibration points helps target certain flow ranges. The rig is user friendly, mobile, and is easily maneuverable for in-line calibration, thereby reducing down time and the risk of contamination by Active Process Ingredients (API). The flow rig can be delivered with a traceable DANAK accreditation, accuracy of < 0.3% of the measured value, and covers a flow range from 5 to 17.000 kg/h. Cleaning can be performed according to industry practice and all wetted parts are CIP-able. The rig can be produced to operate in hazardous areas (ATEX Zone 1). Insatech Pharma has delivered several rigs to various pharmaceutical sites in Denmark, Brazil and France. 15

Contact Insatech Pharma Group Algade 133 DK-4760 Vordingborg Denmark +45 5537 2095 mail@insatech.com www.insatechpharma.com People - Ideas - Solutions www.insatechpharma.com