INSTALLATION GUIDE FIRST STEPS MOUNTING OF THE SENSOR HANDLING THE WIRE ROPE

Similar documents
Draw-wire system SZG165

DRAW WIRE SENSOR. Series SX draw wire mechanics for encoder assembly. Content: Key-Features:

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Mass Flow Controller (MFC) for Gases

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Mass Flow Controller (MFC) for Gases

FTC130 Transmitter. Operating Manual

Mass Flow Controller (MFC) for Gases

Bypass Mass Flow Controller (MFC) for gases

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Instruction Manual BA90 Precision Barometer

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW

Pneumatic spool valve islands

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

LIFTING PIN VDI3366. Item code: B Use and maintenance manual complete of EC conformity declaration. San Maurizio C.

03/07/2014 V

OXY 3690 MP. Measuring transducer for air oxygen

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Gas density monitor With integrated transmitter Model GDM-100-TI

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Manual Power relay SR853

Technical Data. Dimensions

Transmitter CS 21 Operation Manual

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

DK46 - DK800 Supplementary instructions

Miniature controls. Contactors. Overload relays. Starters. Control relays

RPS900W Redundant Power Supply. Installation Guide.

Transmitter CS 21 Operation Manual

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

STAGE, STADIUM & X-TREME SHOT.

DK48 - DK800. Quick Start. Variable area flowmeter

Pressure transmitter PASCAL Ci4

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Mass Flow Meter (MFM) for gases

Mass Flow Controller (MFC) for Gases

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

Technical Data. Dimensions

TECHNICAL CHARACTERSTICS

Technical Data. Dimensions

Norrsken Family Booklet

OPTIBAR P 1010 C Technical Datasheet

Operating Instructions Temperature Measuring System MF420-5T-100

Operating Instructions

Preferred Instruments Danbury, CT USA

APPLICATION NOTES. WIND MEASURING SYSTEMS using XDi-N indicators. Document no.: B

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Installation and Operation Manual

AutoChanger Installation & User Guide Issue 2

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

RTD temperature probes

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Instruction and Maintenance Manual

GEMS SENSORS & CONTROLS

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Vibrating Wire Load Cell (3, 4, 5 And 6 Gauge Cells) User Manual

Operating Instructions Melt Pressure Sensor

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Pre-filter for Brushless Blower Instruction Manual

bikespeed-key Classic with plugable cable set

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

Prewired position switches FA series

High-performance submersible pressure transmitter For level measurement Model LH-10

INSTRUCTION MANUAL Pressure Relief Device LPT

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Operating Instructions

! Warning, refer to accompanying documents.

COOPER POWER SERIES. 600 A 15, 25, and 35 kv class PUSH-OP bushing adapter cap installation instructions. Deadbreak Apparatus Connectors MN650050EN

Polymer Electric. Product information. Normally Closed Safety Edges SL/NC II. GmbH & Co. KG. Polymer Electric

Electronic load cell HF 50

Supplementary Operator s Manual 42/24-14 EN Rev. 3

ELECTRIC ACTUATORS for continuous underwater use

Instruction Manual Differential Pressure Transmitter

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Operating Instructions

High-performance submersible pressure transmitter For level measurement Model LH-20

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

Operating Manual VSA100A. tina29e1 ( )

Digital Melting Point Apparatus

Operating instructions Capacitive sensor KIA (M30) / / 2010

GEMS SENSORS & CONTROLS

Technical Data. Dimensions

Instruction and Maintenance Manual

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

Operating Instructions Part No

Operating instructions Binary level sensor LI / / 2013

Electronic gas volume corrector model DGVC-04

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

e.do Gripper Safety requirements, technical features and assembly and integration instructions

INSTALLATION / USER MANUAL Wallom2 mobile lift HEY YOU, LET ME HELP! Share, inspire, have fun! With CTOUCH by your side.

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Transcription:

INSTALLATION GUIDE Draw wire sensors series SX0, SX80, SX0 For further information please see the data sheet at www.waycon.biz/products/draw-wire-sensors FIRST STEPS WayCon Positionsmesstechnik GmbH would like to thank you for the trust you have placed in us and our products. This manual will make you familiar with the installation and operation of our draw wire sensors. Please read this manual carefully before initial operation! Unpacking and checking: Carefully lift the device out of the box by grabbing the housing. Do not pull the rope. After unpacking the device, check it for any visible damage as a result of rough handling during the shipment. Check the delivery for completeness. If necessary consult the transportation company, or contact WayCon directly for further assistance. MOUNTING OF THE SENSOR Please start by mounting the encoder to the SX draw wire mechanics. A description is given on the following pages. Next mount the sensor at the designated place, before extracting the rope and before attaching the rope to the measuring target. Depending on the sensor model it can be installed either by using the boreholes in the mounting plate,or by using the supplied T-slot nuts/clamp brackets. You will find a detailed description of both installation methods in this installation guide. Open the rope clip after the sensor is fully mounted and carefully extract the measuring rope. Hook the rope clip on the measuring target and close the bracket of the clip. For safety reasons put a screw driver trough the clip to extract the rope HANDLING THE WIRE ROPE When installing or operating the sensor, take care not to let the rope snap back by mistake or extract the rope over the specified measurement range, as this might destroy the sensor. The rope must be extracted from the sensor vertically. The maximum variation from the vertical is. Avoid carefully extracting the rope at an inclination, since the durability of the instrument would shorten considerably. If it is not possible to keep the limit of, a deflection pulley has to be used. Guide the rope preferably in corners or guarded in channels to prevent pollution or accidental touch. Avoid guiding the rope over edges or corners. Use a deflection pulley instead. Do not operate the sensor if the rope is buckled or damaged. A ripping of the rope may lead to injuries or a damaging of the sensor.

MOUNTING SX0 Mounting: standard rope outlet, rope outlet sideways top (S) The sensor is usually installed by using the regular mounting plate. By disassembling the mounting plate, there are threads ( x M, x M) in the sensor housing for alternative installation: Mounting: rope outlet sideways bottom (S), rope outlet bottom (S) Sensors with option rope outlet S and S have a modified base plate: MOUNTING SX80 Mounting: standard rope outlet, rope outlet sideways top (S) The sensor is usually installed by using the regular mounting plate. By disassembling the mounting plate, there are x M threads in the sensor housing for alternative installation: Mounting: rope outlet sideways bottom (S), rope outlet bottom (S) Sensors with option rope outlet S and S have a modified base plate:

MOUNTING SX0 Mounting: standard rope outlet, rope outlet sideways top (S) The sensor is usually installed by using the regular mounting plate. By disassembling the mounting plate, there are x M threads in the sensor housing for alternative installation: Mounting: rope outlet sideways bottom (S), rope outlet bottom (S) Sensors with option rope outlet S and S have a modified base plate:

ELECTRICAL CONNECTION SSI Electrical connection SSI, SX0, cable output tangential Signals 0 V +V C+ C- D+ D- SET DIR Status H Cable colour white brown green yellow grey pink blue red purple GND Electrical connection SSI, SX80, SX0, SX, connector output M, poles Signal 0 V +V C+ C- D+ D- SET PIN 6 7 Signal DIR Status n.c. n.c. n.c. H PIN 8 9 0 shield Electrical connection SSI, SX80, SX0, cable output radial 9 8 0 6 7 Signal 0 V +V C+ C- D+ D- SET DIR Status H Cable colour white brown green yellow grey pink blue red black shield (Isolate unused wires individually before initial start-up) ELECTRICAL CONNECTION CANopen Electrical connection CANopen, SX0, cable output tangential Signal +V 0 V CAN_GND CAN_H CAN_L Cable colour brown white grey green yellow (Isolate unused wires individually before initial start-up) Electrical connection CANopen, SX80, SX0, connector output x M Signal 0 V +V CAN_L CAN_H CAN_GND 0 V +V CAN_L CAN_H CAN_GND PIN Electrical connection CANopen, SX80, SX0 with cable gland radial (removable bus terminal cover) Signal CAN_GND CAN_L CAN_H 0 V +V 0 V +V CAN_L CAN_H CAN_GND Abbreviation CG CL CH 0 V +V 0 V +V CL CH CG

ELECTRICAL CONNECTION PROFIBUS Electrical connection Profibus with cable gland radial (removable bus terminal cover) Power supply Electrical connection EtherCAT x M connector output Power supply ELECTRICAL CONNECTION EtherCAT Signal Transmit data + Receive data + Transmit data - Receive data - Abbreviation TxD+ RxD+ TxD- RxD- PIN Signal Voltage + n.c. Voltage - n.c. Abbreviation +V n.c. 0 V n.c. PIN Signal Transmit data + Receive data + Transmit data - Receive data - Abbreviation TxD+ RxD+ TxD- RxD- PIN D-codiert Electrical connection Profibus, x M connector output Signal n.c. PB_A n.c. PB_B shield PIN Signal +V n.c. 0 V n.c. PIN Signal BUS_VDC* PB_A BUS_GND* PB_B shield PIN * for supplying an external Prof ibus termination resistor Power supply Power supply Signal B A 0 V +V 0 V +V B A Terminal 6 7 8 The shield of the connection cable must be connected over a large area via the cable gland. D-codiert

ELECTRICAL CONNECTION PROFINET Electrical connection Profinet x M connector output Signal Transmit data + Receive data + Transmit data - Receive data - Abbreviation TxD+ RxD+ TxD- RxD- PIN Power supply Signal Voltage + n.c. Voltage - n.c. Abbreviation +V n.c. 0 V n.c. PIN Signal Transmit data + Receive data + Transmit data - Receive data - Abbreviation TxD+ RxD+ TxD- RxD- PIN Power supply D-codiert D-codiert HANDLING THE WIRE ROPE The rope must be extracted from the sensor vertically. Do not pull on the rope directly. This will buckle the rope. Do not operate the sensor if the rope is buckled or damaged. A ripping of the rope may lead to injuries or a damaging of the sensor.

HANDLING THE WIRE ROPE When installing or operating the sensor, take care not to let the rope snap back by mistake or extract the rope over the specified measurement range, as this might destroy the sensor. Avoid guiding the rope over edges or corners. One, or if needed many deflection pulleys can be used to change the extraction direction. The maximum variation from the vertical is. Avoid carefully extracting the rope at an inclination, since the durability of the instrument would shorten considerably. If it is not possible to keep the limit of, a deflection pulley must be used. >

WARNING NOTICES Do not try to open the device. The stored energy of the spring drive may lead to injuries when being mishandled. Do not touch the rope when operating the sensor. When mounting outdoors protect the sensor and the rope from icing at temperatures below 0 C. The usage of a deflection pulley may help defrosting the wire rope. When operating the sensor in a humid environment, install the sensor with the rope outlet downwards. Otherwise water will gather inside the housing, which leads to corrosion. Where applicable use option S. MAINTENANCE The devices are maintenance-free. If however, the rope is soiled due to adverse environmental conditions, it can be cleaned with a cloth drenched in resin-free machine oil. DECLARATION OF EC-CONFORMITY Manufacturer WayCon Positionsmesstechnik GmbH Mehlbeerenstrasse 80 Taufkirchen / Germany This is to certify that the products Classification Product series draw wire sensors SX fulfill the current request of the following EC-directives: EMC-directive 00/08/EC (until April 9th, 06) 0/0/EU (from April 0th, 06) applied harmonized standards: IEC 66-:0 The declaration of conformity loses its validity if the product is misused or modified without proper authorisation. Taufkirchen,.0.06 Andreas Täger CEO