AVEMS & UNICLIMA joint Position paper on Regulation (EU) No.1253/2014 Paris, June 8 th

Similar documents
USER MANUAL. JET TST and JET TST S.

01 18/11/2013 correction of the reference of the product 1 4 5

The routine maintenance and inspection of local exhaust ventilation (LEV)

2017 Edition GUIDANCE NOTE GN 8 INVERTER DRIVES FOR FANS AND PUMPS GN 8 - INVERTER DRIVES FOR FANS AND PUMPS

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

CJTX-C 15/15 0,75 (2V) F-400. Impeller size 2-speed fan. Installed power. (r/min) 230 V 400 V 690 V (kw) m3/h db(a) (kg)

TExT Thorough Examination & Test of LEV Local Exhaust Ventilation Systems

Duration: 4 hours Type: self-learning 2h and class room lectures 2 hours. Dr.sc.ing. Anatolijs Borodiņecs

Lecture 11 Natural Ventilation (Passive Cooling)

SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA

INDICATIONS FOR CHOICE OF ATEX FANS

Building air tightness

ESTATES OFFICE OPERATIONS WORKS INSTRUCTIONS WI 6. Fume Cupboards, Ventilated Cabinets, Local Exhaust Ventilation

REASONS FOR THE DEVELOPMENT

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Gas Injection Systems

Domestic ventilation systems

Automatic extractor outlet

Jennifer Hatfield FSPA Government Relations Consultant J. Hatfield & Associates, PL

Overview ASTATT2. Prepare building for air tightness. testing

Part 1: General principles

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Installation and Operation Manual

Measuring range Δp (span = 100%) Pa

Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA)

Aquavar SOLO 2 Frequently Asked Questions

PLEA th Conference, Opportunities, Limits & Needs Towards an environmentally responsible architecture Lima, Perú 7-9 November 2012

INDICATIONS FOR CHOICE OF ATEX FANS

AIRFOIL PROFILE OPTIMIZATION OF AN AIR SUCTION EQUIPMENT WITH AN AIR DUCT

Vertex VP Operation and Maintenance

LENNOX SLP98UHV DIAGNOSTIC CODES

AXIAL FLOW FANS GENERAL INFORMATION

VENTILATOR OPTIONS. Please visit our web page to view all the available options and for a specification.

Report on the Acceptance Air Leakage Testing of Rectory Cottage in Langattock, Powys, in compliance with ATTMA TSL1 (2010)

MANAGEMENT PROCEDURE FOR LABORATORY VENTILATION

60HZ XIANDAI PUMP. CDL/CDLF Vertical Multistage Pump ZHEJIANG XIANDAI PUMP CO.,LTD. ZHEJIANG XIANDAI PUMP CO.,LTD.

SECTION TESTING ADJUSTING AND BALANCING FOR HVAC

Air Eliminator Series

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

Performance of Duct Leakage Measurement Techniques in Estimating Duct Efficiency: Comparison to Measured Results

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS

CALMO

B. Diagnostic Equipment Information 01 Number of Manometers Used to Measure Home Pressurization Manometer Make. Manometer Serial Number

REAL LIFE GRAPHS M.K. HOME TUITION. Mathematics Revision Guides Level: GCSE Higher Tier

SOFTWARE. Sesam user course. 12 May 2016 HydroD Hydrostatics & Stability. Ungraded SAFER, SMARTER, GREENER DNV GL 2016

Declaration of Performance (DOP)

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Fan and air movement essentials

Committee on NFPA 85

CROSS CONTAMINATION OF IN-SUITE MURB VENTILATION SYSTEMS

Automatic Isokinetic Sampler. ST5 Evo

B. Diagnostic Equipment Information 01 Number of Manometers Used to Measure Home Pressurization Manometer Make. Manometer Serial Number

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Introduction to Pumps

6-5 Maintenance Manual

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Cover Page for Lab Report Group Portion. Pump Performance

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

Fig 2.17: Topographic model: snow-free area (Snow boundary = red) Contour interval of 1 m.

Air Pressure Test to EN13829:2000

The process of measuring air

Understanding Centrifugal Compressor Capacity Controls:

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

Installation, commissioning and servicing instructions

Agile Manager widget descriptions

TESTING AT VERY LOW FLOWRATE

10 December 2010 GUIDANCE FOR WATERTIGHT DOORS ON PASSENGER SHIPS WHICH MAY BE OPENED DURING NAVIGATION

Instruction manual. D-Range. Negative Pressure Unit D 60 E D 60 D 100 D 305 D 610 D 910 D 1200

Operation of WinVent 4.0

Deborah Houssin-Agbomson, Jean-Yves Letellier, Philippe Renault, Simon Jallais

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

High Efficiency SO2 Scrubber Design to Reduce Caustic Consumption

Ventam 85 Installation & Commissioning Instructions

6. EXPERIMENTAL METHOD. A primary result of the current research effort is the design of an experimental

PX400 P L A S T I C PX400 PERFORMANCE WIL T-02

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

INGROUND OR ABOVE GROUND POOL. APPROVALS REQUIRED (Check here if): Well Septic

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

PX4 P L A S T I C PX4 PERFORMANCE WIL T-02

Air Leakage of Furnaces and Air Handlers

Robotic Pool Cleaners

Thorough Examination and Test of Local Exhaust Ventilation Systems to Regulation 9 of the COSHH Regulations 2002 (as amended)

GM Series Dual-Block Multi-Function Gas Control Valves

Pressure Differential Systems

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Air Leakage Detailing & Awareness Services

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

ACCUMULATION OF HYDROGEN RELEASED INTO A VENTED ENCLOSURE - EXPERIMENTAL RESULTS

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

SUMMARY STEPS TO CERTIFY AIRFLOW MEASUREMENT PERFORMANCE UNDER AMCA INTERNATIONAL S CERTIFIED RATINGS PROGRAM

Installation, commissioning and servicing instructions

ERTC PETROCHEMICAL Conference 20 st -22 nd February 2002, Amsterdam, The Netherlands

PORTABLE GAS FREEING FAN

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

The system design must obey these constraints. The system is to have the minimum cost (capital plus operating) while meeting the constraints.

Air Amplifiers & SYSTEMS

ME 449/549 Lab Assignment 2 Spring 2006 due 25 April Background. 2 Apparatus

LABORATORY FUME HOOD SPECIFICATION AND MAINTENANCE PROGRAM

Transcription:

AVEMS & UNICLIMA joint Position paper on Regulation (EU) No.1253/2014 Paris, June 8 th Considerations about hybrid and low pressure ventilation fans in the regulation 1253/2014 1) Definition of hybrid fans The hybrid fans are in general roof fans designed to complement the natural forces, thermal draught and wind effect. The wind effect is described in EN 13141-5: when the wind crosses the cowl it induces a negative pressure at the top of the duct that gives suction effect and produces vertical flow in the duct. The thermal draught depends on the temperature difference (indoor outdoor) and of the vertical height of the duct. Hybrid ventilation fans are generally characterised by the following facts: Hybrid fans are dual products: cowls and fans. They provide additional pressure to the one generated by the thermal draught and wind effect They have a dual working mode : mechanical and natural Their specific consumption is quite good They have a very low pressure loss when they are off, and have a wind effect. They produce very low mechanical pressure, between 5 to 15 Pa, when they are on, and still benefit from the wind effect and thermal draught (EN 13141-5 is under revision to include correctly this additional effect). Figure 1: Sketch of hybrid ventilation system (E = hybrid fans, other letters = components of the system)

Wind Wind effect: Additional pressure is provided thanks to the wind. Figure 2: Wind effect 2) Definition of low pressure ventilation fans The low pressure ventilation fans are casing fans. Low pressure ventilation fans are generally characterised by the following facts: Their specific consumption is quite good They produce very low mechanical pressure between 15 to 30 Pa, and benefit from the thermal draught. Figure 3 : Sketch of low pressure ventilation system (A = low pressure fan, other letters = components of the system)

Advantages: Hybrid ventilation enables to reuse without any modification (no need to reinforce the airtightness) the duct formerly used in PSV (Passive Stack Ventilation) as it keeps the pressure level ( from 5 to 15 Pa ) Low pressure ventilation system enables to reuse without any modifications (no need to reinforce the airtightness) the duct formerly used in PSV (Passive Stack Ventilation) as it keeps the pressure level ( from 15 to 30 Pa ) SPI of hybrid fans is very good thanks to low pressure and intermittent working although their efficiency is poor (typically less than 15%). For example, an average of 6 W/dwelling is generally measured, which is much lower than most other ventilation systems. These fans have a real and great interest in retrofitting the 50 s to 70 s collective buildings in several countries of Europe as they are directly compatible with the existing ductwork and roof outlets. Hybrid ventilation and low pressure ventilation in Eco-design regulation: Up to 1000 m3/h hybrid fans could be considered as RVU (residential ventilation units) if declared by the manufacturers, and their SEC could match the requirements. However the regulation doesn t allow the assessment of hybrid ventilation systems due to the pressure level which is lower than the ones required in the regulation (100 and 50 Pa for ducted units). Above 250 m3/h (if not declared as RVU) or above 1000 m3/h they would be considered as NRVU and will never match the efficiency requirements due to very low pressure level. These products would hardly fulfil the requirements of the directive as it is written today although they respect the spirit of the text, as offering a very good energy performance along the year.

There are several issues on the regulation on the table in annex to justify the exemption of hybrid fans from the scope. N Part of n 1253/2014 Commission Regulation Comment Proposal 1 Article 2 1) ventilation unit (VU) means an electricity driven appliance equipped with at least one impeller, one motor and a casing and intended to replace utilised air by outdoor air in a building or a part of a building; 2 Article 2 4) maximum flow rate is the declared maximum air volume flow rate of a ventilation unit that can be achieved with integrated or separately cosupplied controls at standard air conditions (20 C) and 101 325 Pa, where the unit is installed complete (e.g. including clean filters) and according to the manufacturer's instructions, for ducted RVUs the maximum flow is related to the air flow at 100 Pa of external static pressure difference, and for non-ducted RVUs to the air flow at the lowest achievable total pressure difference to be chosen from a set of values of 10 (minimum)-20-50-100-150-200-250 Pa, whichever is equal or just below the measured pressure difference value; 3 Annex I 1. Définitions 9) external leakage rate means the leakage fraction of the reference air volume flow to or from the inside of the casing of a unit to or from the surrounding air when it is subjected to a pressure test; the test shall be performed at 250 Pa for RVUs and at 400 Pa for NRVUs, for both under and over pressure; 5 Annex I 1. Définitions 14) flow rate/pressure diagram means a set of curves for flow rate (horizontal axis) and pressure difference of a unidirectional RVU or the supply side of a bidirectional RVU, where each curve represents one fan speed with at least eight equidistant test-points and the number of curves is given by the number of discrete fan speed options (one, two or three) or, in the case of a variable fan speed drive, includes at least The meaning of «casing» explained in the discussion document is not clear, especially the figure 14. Hybrid extractor, assisting natural ventilation, are not composed by a «casing» because ventilation has to be possible when motor is turned off. For ducted RVUs, how to declare the maximum flow rate for hybrid extractors or low pressure ventilation systems whose maximal pressure is under 100Pa? For hybrid extractors which are not composed by a casing, it is not possible de measure the external leakage rate. It is not clear if the pressure difference has to be done in total pressure (p f ) or static pressure (p sf ). Clarify the definition in the FAQ or hybrid extractors have to be excluded from the scope. Clarify in the FAQ how to deal with other pressures for ducted RVUs Clarify in the FAQ Clarify in the FAQ

N Part of n 1253/2014 Commission Regulation Comment Proposal a minimum, maximum and appropriate intermediate curve close to the reference air volume and pressure difference for SPI testing; 6 Annex I 1. Définitions 15) reference flow rate (expressed in m3/s) is the abscissa value to a point on a curve in the flow rate/pressure diagram which is on or closest to a reference point at 70 % at least of the maximum flow rate and 50 Pa for ducted units and at a minimum pressure for non-ducted units. For bidirectional ventilation units, the reference air volume flow rate applies to the air supply outlet; 7 Annex I 2. Definitions for NRVU 4) reference configuration of an UVU means a product configured with a casing and at least one fan with variable speed or multi-speed drive, and in case the product is intended to be equipped with a filter on the inlet-side this filter shall be a clean fine filter; The reference flow rate, as defined, is not a flow rate possible for hybrid extractors and low pressure ventilation systems because 50 Pa cannot be reached. Same comment as n 1 Clarify in the FAQ how to deal with other pressures for ducted RVUs 8 Annex VIII «ta» value «ta» value has a default value not taking into account hybrid extractors specificity. Indeed, hybrid extractor s motors run in an intermittent way (depending external temperature and wind velocity) and not continuously. 9 Annex VIII Some hybrid extractors can control motor s rotation speed depending the external temperature. In that case, the Specific Energy Consumption (SEC) gain is not taken into account in the formula and «CTRL» «x» parameters are not suitable. Take into account hybrid extractor s natural mode (indeed with the motor turned off). Clarify SEC formula to take into account this kind of hybrid extractor, or hybrid extractors have to be excluded from the scope.

Consideration about scope of Regulation 327/2011 and Regulation 1253 for hybrid ventilation fan units: Are the ventilation product related to the regulation n 1253/2014? Figure 4: Hybrid product 1 Figure 5 : Hybrid product 2 Figure 6: Hybrid product 3