Installation Instructions

Similar documents
RG1200 Service and Repair Manual

DS05C,D,G Dial Set Pressure Regulating Valves

INSTALLATION INSTRUCTIONS

D05 Pressure Regulating Valves

Installation Instructions

MAINTENANCE PROCEDURE FOR X 650

DS06D,G Dial Set Pressure Regulating Valve

TECHNICAL DATA CAUTION

Installation, Operation and Maintenance Manual for Back Pressure Regulator

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

SCUBAPRO. Balanced Power Inflator

Model VR6 System. Installation, Operation & Maintenance

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Service and Repair Manual

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

D05T Compact Design Pressure Regulating Valves

Pressure Dump Valve Service Kit for Series 2300 Units

PAPR Flow Tester. instructions. part no WARNING

Pressure Dump Valve Service Kit for Series 3000 Units

TECHNICAL INSTRUCTIONS

Halsey Taylor Owners Manual STOP!

12S 1st Stage. -Maintenance Procedure-

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Installation Instructions

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

Installation of Your SprayMaster System

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Installation Troubleshooting Maintenance Instructions Installation / Start-up

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

SCUBAPRO Repair Guide. S600-S550 Second Stages

Installation, Operation, and Maintenance Manual

T1-Titanium HVLP Pressure Feed Spray Gun

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

V43 Pressure Actuated Water Regulating Valve

LEAK TROUBLESHOOTING

Bermad Model:

Beverage Systems. Component Inspection and Service TSB-Y Date: Subject: Products Affected: Description: July Inspection of CO 2

Model 420-HY Pressure Regulating Hydrant Valve

Installation S Gallon Tank (ASME rated) with Eyewash and Hose Spray

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

Hydraulic Punch Drivers

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

Installation, Operation, and Maintenance Manual

TECHNICAL DATA ACCELERATOR MODEL E-1

Product Information News September 26, 2003

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Flexi-pro Aerosol Delivery System (FADS) Manual

1200B2 Series Service Regulators. Instruction Manual

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

GM Series Dual-Block Multi-Function Gas Control Valves

Freedom8 ShoeBox Compressor Manual

LRS(H)4 Pressure-Reducing Regulator User Manual

Booster Pump PB4-60 Replacement Kits

1805 Series Relief Valves

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Operating Instructions Model and Hydrostatic Test Pump

Type CT88 Backpressure Regulator

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

THE KEENEY MANUFACTURING COMPANY

Type FEQ Slam-Shut Valve

Speed control assembly model A-1

Installation, Operation, and Maintenance Manual

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

TECHNICAL DATA OBSOLETE

Model MC Circuit Setter Hose Kits Supply Valve Options: Ball Valve, UBY

Model: 43T. Bermad Pressure Relief Valve

1800C and 1800C-HC Series Service Regulators

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Anti-flood device Model B-1

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

WW-720. Pressure Reducing Control Valve

Hydraulic Piston Accumulators

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

GM-7000 Series CE Approved Gas Control Valve

MEGR-1627 Instruction Manual

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

WW-730. Pressure Sustaining/Relief Control Valve

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

WW-720. Pressure Reducing Control Valve

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Operating Instructions Models and Hydrostatic Test Pumps

2.0 INSTALLATION & SERVICE

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

RS(H)20, 25 USER MANUAL

H4802, H4802-1, H , and Pole Tampers

Adjustable. Unloader Valve. O&M Manual. Part #

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

PANACEA P100 LOW PRESSURE USER MANUAL

PANACEA P200 STAINLESS STEEL USER MANUAL

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series

Transcription:

Installation Instructions S65-135 (Circular) S65-136 (Semi-Circular) Air Valve Retrofit For Non-Sectional Classic Washfountain Table of Contents.......................2-6 Metering Air Valve Parts List....................6 Metering Air Valve Troubleshooting.............. 7 215-1184 Rev. F; EN 06-915B 2007 Bradley Corporation Page 1 of 7 4/6/2007 P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-Bradley FAX 262-251-5817 http://www.bradleycorp.com

Air Valve Retrofit Step 1: Replace valve parts Note: Shut off water supply before making any improvements to the unit. Note: Units with one actuator do not require tee S53-046, Check Valve 269-1140 or Adapter 198-008 1. Remove all parts above existing volume control valve. 2. Assemble new parts as shown in Figure 1a (Circular Washfountain) or 1b (Semi-Circular Washfountain) and Figure 3a or 3b. Note: Do not install the tubing from the sprayhead or actuators at this time. 1/8" TUBE CONNECTOR (169-890) CHECK VALVE (269-1140) ADAPTER (198-008) TUBING FROM SPRAYHEAD 1/8" O.D. TEE (S53-046) 1/8" O.D. TUBING TO ACTUATORS 3/8 NPT x 1/2" O.D. TUBE CONNECTOR (269-626) 3/8 NPT NIPPLE (113-006AL) AIR VALVE (S07-044) REDUCER (169-059) STOP-STRAINER-CHECK VALVE (S60-003) VOLUME CONTROL VALVE (S02-045) Figure 1a TMA (OPTIONAL) (S01-525) TAILPIECE NUT (110-005) FIBER WASHER (124-001AF) TAILPIECE (129-007) MANUAL MIXING VALVE (S01-038) Circular Washfountain (2 Actuators) 2 Bradley Corporation 215-1184 Rev. F; EN 06-915B 4/6/2007

Air Valve Retrofit continued... 1/8" O.D. TUBING TO ACTUATOR TUBING FROM SPRAYHEAD 3/8 NPT x 1/2" O.D. TUBE CONNECTOR (269-626) 3/8 NPT NIPPLE (113-006AL) AIR VALVE (S07-044) REDUCER (169-059) STOP-STRAINER-CHECK VALVE (S60-003) VOLUME CONTROL VALVE (S02-045) Figure 1b TMA (OPTIONAL) (S01-525) TAILPIECE NUT (110-005) FIBER WASHER (124-001AF) TAILPIECE (129-007) MANUAL MIXING VALVE (S01-038) Semi-Circular Washfountain (1 Actuator) Step 2: Install the module onto the sprayhead Note: Refer to Figure 1a or 1b, Figure 2, 3a or 3b, and 4 when assembling the module to the sprayhead. Assembly shown in Figure 3a or 3b is for units with one actuator. 1. Remove all accessories above the sprayhead (soap dispenser, infrared module, etc.). 2. Remove the old supply line from the sprayhead. Bradley Corporation 215-1184 Rev. F; EN 06-915B 4/6/2007 3

Air Valve Retrofit continued... 3. To install one end of the new 1/2" supply tubing and make the connection to the sprayhead, follow the instructions outlined below (Figure 2). Using a sharp razor, cut 1/2" tubing squarely and remove any burrs. DO NOT pinch or crush end of tubing. Insert the tubing into the male connector: loosen the nut on the fitting until three threads are exposed. Moisten the end of the tube and push it into the fitting until it is firmly seated. Hand tighten the nut to secure the tube to the fitting. If the connector leaks, reset the tubing according to the above procedure. If leaking persists, replace the male connector, or call your Bradley representative for assistance. 4. Connect the other end of the 1/2" supply tubing to the male connector on the air valve assembly (Figure 1a or 1b). Figure 2 NUT SPRAYHEAD TUBING MALE TUBE CONNECTOR 1/2 TUBING 4 Bradley Corporation 215-1184 Rev. F; EN 06-915B 4/6/2007

Air Valve Retrofit continued... 5. Place the push button module over the sprayhead (Figure 3a or 3b). If the 1/8" tubing is not connected to the push button assembly, connect the 1/8" tubing to the tube connector (located at the back of the push button assembly) at this time (Figure 4). 6. Feed the 1/8" tubing down the inside of the support tube to the air valve assembly. (See Figure 3a or 3b). FOR UNITS WITH TWO ACTUA- TORS: connect the 1/8" tubing from the actuators to the tee, then connect the 1/8" tubing from the tube connector on the air valve to the tee (Figures 1a and 4). FOR UNITS WITH ONE ACTUATOR: connect the 1/8" tubing from the actuator to the tube connector on the air valve (Figures 1b and 4). NOTE: Insert the end of the tubing into the connector until it is firmly seated on the tube stop. 7. Turn the water supply back on and check for leaks. 8. Push the button(s) to activate the sprayhead. Water should flow out from the entire sprayhead. If this does not happen, refer to the air valve troubleshooting instructions found on page 7 and follow the procedure outlined there until the water is flowing properly. 9. When the retrofit assembly is complete, reassemble the washfountain. Pushbutton Module Tubing Sprayhead Figure 3a Pushbutton Module Drain Type A/O Tie Rod, 4-1/4" Long (176-118) Coupling Nut (110-051D) & Set Screws (160-208) Support Tube RELEASE BUTTON SEALING RING 1/8 TUBING LOCKING SLOPE GRIPPING RIDGE Tubing Sprayhead Figure 3b Drain Type B/H Support Tube Figure 4 TUBE STOP Bradley Corporation 215-1184 Rev. F; EN 06-915B 4/6/2007 5

Air Valve Retrofit continued... Step 3: Adjust the air valve metering time Note: The air valve timer is located next to the tube connector on the air valve body. The timer is capped with a filter to prevent dirt build-up on the timer. The air valve timing can be adjusted from 5-45 seconds. Refer to Figure 5 when adjusting the air valve. 1. Remove the filter cap. Use a screwdriver to tighten or loosen the timer. Turning the timer clockwise increases the time, turning the timer counterclockwise decreases the time. 2. Continue to adjust the timer until it is set at the desired length. 3. Replace the filter cap. Figure 5 Metering Air Valve Repair Kits and Parts List LOWER VALVE BODY 118-226A VALVE SEAT 117-036 RUBBER DIAPHRAGM 269-665 PLASTIC DISK 269-664 STAINLESS STEEL DISK 179-082 SPRING 135-053 PARTS INCLUDED IN KIT S65-110 REPAIR KIT S73-054A (Note: This repair kit also includes kit S65-110) LOCKWASHER 142-002CR SCREW 160-313 6 Bradley Corporation 215-1184 Rev. F; EN 06-915B 4/6/2007

Air Valve Retrofit Metering Air Valve Troubleshooting Problem: Valve will not shut off. Cause: Timing mechanism is clogged. Solution: Clean and inspect timing mechanism: 1. If compressed air is available, blow water and debris from perforated metal sleeve of timing mechanism. 2. Turn adjusting screw in all the way but do not force screw. 3. Turn adjusting screw out to desired cycle time. Problem: Valve will not turn on. Cause: Water is not being supplied to unit. Solution: Open all stops on mixing valve. Problem: Timing can not be adjusted for more than 5 seconds. Cause: There is an air leak Solution: Check the valve assembly: 1. Check all tubing and fittings for proper assembly. 2. Tighten all screws which hold valve together. Problem: Push button does not work properly. Cause: Air volume may not be sufficient to operate valve. Solution: Check for leaks and lubricate U-cup: 1. Check all fittings for air leaks. 2. Disassemble pushbutton and lubricate U-cup seal. Problem: Water is dripping from the streamformers. Cause: Debris has accumulated on valve seat or orifices. Solution: Clean and inspect valve seat. 1. Remove screws and disassemble metering valve. 2. Clean valve seat and inspect for deep gouges or scratches. Replace if necessary. 3. Remove all debris that may be clogging center hole of plastic diaphragm assembly. 4. Remove any debris clogging off-center hole in rubber diaphragm. Bradley Corporation 215-1184 Rev. F; EN 06-915B 4/6/2007 7