Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Similar documents
Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Pressure Switch for DMV safety shutoff valves

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Butterfly Control Valve. DMK/6 Series

Valve Proving System VDK 200 A S06*

Gas Pressure Switch for DMV safety shutoff valves

Valve Proving System VDK 200 A S02

Pressure Switch for gas and air GGAO-A4

Pressure Switch for gas and air

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

Gas Pressure Switch for DMV safety shutoff valves

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

Ratio Regulator Zero Governor. FRG/6 Series

SPECIFICATIONS ATTENTION

Pressure switch for gas and air

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first O.K. IFGC CSA UL ANSI NFPA

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

SPECIFICATIONS ATTENTION

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first IFGC CSA UL ANSI NFPA

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Pressure Switch for gas and air

SPECIFICATIONS CAPACITY

Commonwealth of Massachusetts Approved Product Approval code G

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Commonwealth of Massachusetts Approved Product Approval code G

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

FRS 7../6 series are CSA Certified: ANSI Z21.80 / CSA 6.22 Class I. Commonwealth of Massachusetts Approved Product Approval code G

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

Old documentation - Only for your information! Product is not available anymore!

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

O.K. Safety first USA CDN. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA. MBC-VEF 1000/2500/4000 GasMultiBloc

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

BGA158 Series CE Approved Class A Shutoff Gas Valve

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

BGA158 Series CE Approved Class B Shutoff Gas Valve

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA. MBC-SE 1000/2500/4000 GasMultiBloc

GM Series Dual-Block Multi-Function Gas Control Valves

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

Compact pressure switches for gas and air

Slam Shut Valves SCN

Dual Solenoid Gas Valve Installation

SKPx5.xxxUx Gas Valve Actuator with Safety Shutoff Function. SKP15.xxxUx SKP25.xxxUx SKP55.xxxUx SKP75.xxxUx

GM-7000 Series CE Approved Gas Control Valve

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

VMR VMR-OTN VMR 6 bar

SKPx5.xxxUx Gas Valve Actuator with Safety Shutoff Function. SKP15.xxxUx SKP25.xxxUx SKP55.xxxUx SKP75.xxxUx

G95 Series BASOTROL Single Operator Valve

Tightness controls TC 1 3 and TC 4

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Tightness control TC. Product brochure GB 3 Edition AGA

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

RR 16 Commercial & Industrial Regulator

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Pressure Regulator 133 / 233

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

Gas Pressure Regulator HON 200

Slam Shut Valves SBC 782

RB 4700 Commercial & Industrial Regulator

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

North American Pressure Switches

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

Transcription:

Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I File # 0989 FM Approved Class 7411 File # J.I.1Z6A0.AF Commonwealth of Massachusetts Approved Product Approval code G1-1107-35 Gas Safety Shutoff Valve DMV/602 Sales Brochure P/N 226377 Ed. 08/16 US, Canadian and EU Models DMV-D 701/602, 702/602, 703/602 DMV-DLE 701/602, 702/602, 703/602 1/2 in. NPT - 2 in. NPT Rp1/2 - Rp2 Codes and Standards This product is intended for installations covered by but not limited to NFPA 37, NPFA 86, ANSI Z83.4, ANSI Z83.18, ANSI Z21.13, CSD-1, UL 795, CSA B149.1 and CSA B149.3. DUNGS is an ISO 9001 manufacturing facility. Description The Dual Modular Valve (DMV) combines two automatic shutoff valves in one compact housing, which can be wired independently or in parallel. Valve 1 (V1) of the DMV-D and DMV-DLE series is fast opening and fast closing. Valve 2 (V2) of the DMV-D is fast opening, while V2 of the DMV-DLE is slowopening for smoother light-off. Max. flow adjustment on V2 provides variable main flow on both models. Internal profiles and compact design optimize flow and provide a low pressure drop. Three body styles reduce inventory. Directly mounting the following accessories creates a compact valve train without additional piping: - Pressure regulator - High and low gas pressure switches - Valve proving system - Vent line adapter Application The DMV is recommended for industrial and commercial heating applications that require two safety shutoff valves. The DMV is suitable for dry natural gas, propane, butane, air and inert gases. A dry gas has a dew point lower than +15 F and its relative humidity is less than 60 %. 1 6

DMV-D /602 Two normally closed safety shutoff valves in one housing. V1 and V2 are fast opening, fast closing. Adjustable max. flow with V2. DMV-DLE /602 Two normally closed safety shutoff valves in one housing. V1 fast opening, fast closing. V2 is slow opening, fast closing. Adjustable max. flow and adjustable initial lift with V2. Specifications Body sizes DMV 701 DMV 702 DMV 703 Pipe size / Thread 1/2-1 NPT or Rp 1-2 NPT or Rp 1-2 NPT or Rp Max. operating pressure 7 PSI (500 mbar) UL, FM 5 PSI (360 mbar) CSA Max. body pressure 15 PSI (1000 mbar) Max. close off pressure 7 PSI (500 mbar) UL, FM 5 PSI (360 mbar) CSA Electrical ratings (+10 % / -15 %) 110-120 VAC @ 50-60 Hz 24 VAC @ 50-60 Hz; 24 VDC Power ratings DMV 701: VA DMV 702: 65 VA DMV 703: 80 VA Ratings shown are total power consumption for both valves inclusive. Inrush and full load current have the same VA rating. Enclosure rating NEMA Type 12 Electrical connection DIN-connector with 1/2 NPT conduit adapter (order separately) Operating time 100 % duty cycle Closing time < 1 s Opening time (to max. flow) DMV-D V1 & V2 < 1 s DMV-DLE V1 < 1 s; V2 Adjustable to approx. 10 to 20 s at 70 F Initial lift adjustment Adjustable on V2 DLE only; 0 to 70 % of total flow; 0 to 35% of stroke Max. flow adjustment Adjustable on V2 <10 to 100 % of total flow; <10 to 100% of stroke Materials in contact with gas Housing: Aluminium, Steel; free of non-ferrous metals Sealings on valve seats: NBR-based rubber Ambient temperature rating -40 F to +150 F (-40 C to +65 C) Installation position Safety shutoff valve from vertically upright to horizontal Gas filter (optional) Replaceable integral gas filter (50 micron) in inlet of DMV or Pre-Mount Filter Block for DMV 702 and 703. (Cannot be used with FRI directly mounted to the DMV) Gas strainer (standard) Installed in the housing upstream V1 (23 mesh) Position indication (order separately) Test ports / Pressure switch mounting ports Valve proving system CPI 400 with indication lamps and SPDT interlock switch or Visual indicator (VI) G 1/8 ISO 228 ports available on both sides. Each side has one port upstream V1, one between V1 and V2, one downstream V2, and one on each flange. Requires VPS 504; mounts directly to either side of DMV FRI Gas pressure regulator Mounting the FRI series gas pressure regulator directly to the DMV dual safety shutoff valve is possible with a mounting kit. The FRI pressure regulator can be installed upstream or downstream of the DMV dual safey shutoff valve depending on application requirements. Replacement FRI to DMV mounting kit FRI 705-707/6 to DMV 701/602 Order No. 219967 FRI 710-712/6 to DMV 702/602 & 703/602 Order No. 219968 Additional Accessories VPS 504 Valve proving system (approved by some authorities having jurisdiction in lieu of vent valve and proof of closure ). Integral gas filter (optional) 50 micron gas filter Pre-Mount Filter (optional) 50 micron gas filter GAO/GMH/GML A2 gas pressure switch Position indication CPI 400 with indication lamps and SPDT interlock switch, or visual indicator (VI) DMK butterfly control valve Mounts directly downstream of DMV to modulate gas flow. Requires actuator. Use DMA actuator with DMK butterfly valve. DMV D(LE) 7xx/602 VL (with vent line adapter) Factory installed vent line adapter which integrates a vent line connection with the DMV series. Adapters 1/4 NPT adapter (225047) 1/2 NPT Pilot gas adapter; Check flow requirements. (225043) G 1/8 Test nipple (219008) Port 3 Pressure switch mounting adapter (273777) 2 6

DMV dual safety shutoff valve modular system Optional mounting system shown, other configurations possible DMV dual safety shutoff valve with upstream FRI pressure regulator P max. = 7 PSI Pressure switch can be mounted on flange High gas pressure switch Low gas pressure switch Valve proving system (VPS 504) Position Indicator: CPI 400 interlock switch on V1 or V2 Visual Indicator (VI) on V1 or V2, or on both DMV dual safety shutoff valve with downstream FRI pressure regulator P max. = 7 PSI When an accessory is added to the DMV, it may not be possible to mount other devices. Low gas pressure switch Valve proving system (VPS 504) High gas pressure switch Position Indicator: CPI 400 interlock switch on V1 or V2 Visual Indicator (VI) on V1 or V2, or on both Valve Description Flange NPT Part No. Rp Part No. O-ring and bolt kit P/N* FRI mounting Kit P/N** DMV-701/602 1/2 222371 222341 224093 219967 230440 DMV-701/602 3/4 222368 222342 224093 219967 230440 DMV-701/602 1 221999 222001 224093 219967 230440 DMV-702/602 & 703/602 1 222369 222343 224094 219968 230441 DMV-702/602 & 703/602 1 1/4 222370 222344 224094 219968 230441 DMV-702/602 & 703/602 1 1/2 222003 221884 224094 219968 230441 DMV-702/602 & 703/602 2 221997 221926 224094 219968 230441 Integral filter & strainer replacement 3 6 Accessories/Adapters P/N DIN-Electrical Connector 210319 CPI 400 valve switch 266968 Visual indicator 266949 1/4 NPT adapter 225047 Accessories/Adapters P/N 1/2 NPT Pilot gas adapter: 225043 Check flow requirements G1/8 Test nipple 219008 Port 3 Pressure switch mounting adapter 273777

Dimensions inch (mm) Please order flanges, position indicators and gas filters separately Type 110-120 VAC @ 50-60 Hz Order No. 24 VAC 50-60 Hz Order No. 24 VDC Order No. Power* [VA] DMV-D 701/602 224842 228220 226990 3.7 93 DMV-D 702/602 224843 228221 226991 65 4.9 DMV-D 703/602 224844 228222 226992 90 4.9 DMV-DLE 701/602 2248 228223 226993 3.7 93 DMV-DLE 702/602 224846 228224 226994 65 4.9 DMV-DLE 703/602 224847 228225 226995 90 4.9 Dimensions [inch] Dimensions [mm] a b** c**** d e 5.6 141 5.6 141 * Inrush current and full load current have the same VA rating. ** DMV 702/703 with 1 or 1-1/4 flange: 6.9 / DMV 702/703 with 1-1/2 or 2 flange: 8.1 *** When using the CPI Closed Position Indicator switch add. 3. When using with the vent line adapter assembly, add 1.65 to dimension c. (see vent line adapter information sheet) 1.4 35 1.4 35 5.3 134 5.9 150 7.5 190 6.4 160 6.7 179 8.6 218 2.9 73 2.9 73 Weight [lbs] [kg] 4.6 2,1 10.1 4,6 12.1 5,6 4.8 2,2 10.3 4,7 12.3 5,7 Flow (CFH) of natural gas, s.g. 0.65 at 60 F with 1 in. W.C. pressure drop @ 1.25 psi inlet pressure. 1/2 3/4 1 1-1/4 1-1/2 2 DMV 701 3 429 7 DMV 702 1065 1277 1368 1430 DMV 703 1230 1532 1698 1795 4 6

DMV-D(LE) /602 sectional drawing 1 Strainer 2 Flange 3 Valve V1 4 Housing 5 Closing spring V1 6 Plunger V1 7 Solenoid V1 8 Electrical connection 9 Max flow adjustment 10 Initial lift adjustment (DMV-DLE) 11 Hydraulic brake (DMV-DLE) 12 Valve V2 13 Closing spring V2 14 Plunger V2 15 Solenoid V2 16 Solenoid housing 17 Visual indicator (VI) 18 CPI 400 interlock switch Pressure drop for other gases To determine the pressure drop when using a gas other than natural gas, use the flow formula below and f value located in the table below to determine the corrected flow rate in CFH through the valve for the other gas used. For example, when using propane, divide the volume (CFH) of propane required for the application by the calculated value f (f = 0.66 for propane). Use this corrected flow rate and the flow curve on the next page to determine pressure drop for propane. Determining equivalent flow through valves using another gas f = V gas used = V Natural gas x f Density of Natural gas Density of gas used Type of gas Density [kg/m 3 ] s.g. f Natural gas 0.81 0.65 1.00 Butane 2.39 1.95 0.58 Propane 6 1.50 0.66 Air 1.24 1.00 0.80 5 6

Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Flow curve Pressure drop (in. W.C.) Based on 60 F 14.65 psia, dry Flow (CFH) of natural gas; s.g. 0.65 at 60 F 20 in W.C. We reserve the right to make any changes in the interest of technical progress. Karl Dungs, Inc. 3890 Pheasant Ridge Drive NE Suite 150 Blaine, MN 55449, U.S.A. Phone 763 582-1700 Fax 763 582-1799 e-mail info@karldungsusa.com Internet http://www.dungs.com/usa/ Karl Dungs GmbH & Co. KG P.O. Box 12 29 D-73602 Schorndorf, Germany Phone +49 (0)7181-804-0 Fax +49 (0)7181-804-166 e-mail info@dungs.com Internet http://www.dungs.com 6 6