Quick Neck. User Manual. Photo: Jonas Dahm / Deep Sea Productions

Similar documents
Glove Lock QCP. User Manual. Photo: Anders Salesjö, Lysekil

VIRGO. User Manual. Photo: Jonas Wall

ANTARES. User Manual ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH. Photo: Jonas Andersson, Lysekil

QCS Oval. User Manual. A MODULAR QUICK CHANGE SOLUTION BY SI TECH Prepared for the ANTARES Dry Glove System. Photo: Johanna Strömgren

Gluing Guide QCS Oval & Quick Cuff

Photo: Jonas Wall ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH.

SI TECH Product Guide

Latex & Silflex Wrist & Neck Seals

Waterproof Drysuit Manual

Dry Glove Systems & Quick Change Systems

DRYSUITS DRYSUIT OPTIONS SANTI 2014 RETAIL PRICING GUIDE COLOR OPTIONS: ZIPPER OPTIONS: BOOTS OPTIONS:

WETSUIT OWNER S MANUAL

Congratulations! You own an R9 Cobra! A compact, fast handling and powerful crossbow for your serious shooting enjoyment!

Drysuit Care Information

Read where you love to read the pool, the tub, or the beach with the waterproof Guardian Case for Kindle!

PREMIUM PROTECTIVE SUITS AND EQUIPMENT FOR MARITIME OPERATIONS - V.2 - Q AMPHIBIOUS SOLUTIONS BY NEPTUNUS. distributed by

ZipSeals. NECK Installing a Neck ZipSeal 1.Your drysuit must be equipped with a ZipRing on the neck.turn the suit inside out.

USER MANUAL. All rights reserved

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

Dry Gas Couplings. Service Instruction 3 Tank Unit. Subject to design changes Art. nr: PR Version:

User manual STARLOCK. Careways International - Innovation Quality Performance

SMA2100 Series CONSTANT WEAR LIFE PRESERVER VEST (CWLP) SMA2160 OWNERS MANUAL

User instruction Trellchem Bayonet Ring System mark III with locking pin

User's Manual. MixRite TF 10. Edition 05.08

Underwater Fiber-Optic Plane Irradiance Collector

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS HELMET AND EMERGENCY GAS SYSTEM DAILY SET-UP AND FUNCTIONAL CHECKLIST APPENDIX A2.

1 waterp wa r te o rp o r f o - of us us a a..com co m Waterproof Wetsuit Manual

PIRATE SHIP. Ahoy Matey

DIVATOR RS4 USER MANUAL

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

INSTRUCTION MANUAL FOR USE OF BABY WALKER FLOWER

For Salvo Primary Dive Lights

Objectives (1 of 3) List at least two types of materials and designs used in rope manufacture. Define and describe the following: Dynamic rope Static

"HAND, WRIST AND FINGER SAFETY IN CONSTRUCTION ENVIRONMENTS"

"HAND, WRIST AND FINGER SAFETY"

Rapid Survival System

1. Unlimited, so long as adequate facility, supplies and time are provided to ensure comprehensive and complete training of subject matter

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

AR251/AR251-B. Venepuncture and Infusion Arm. Instruction Manual

Instructions for use: Of adhesive ski skins and cut-to-size sets

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

Inflatable Stand Up Paddle Board Manual

Fantasea F580EX Mark II Flash Housing for Canon 580EX Mark II Speedlite

Flashlight. Hand Lanyard. 36 Super Bright LED Bulbs. Sensor

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Underwater Housing for Canon EOS M

B.C.D. Buoyancy Compensator Device User Manual

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

Contents: 1. Introduction

FUCILI GUNS FUSILS FUSILES

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

SERVICING MULTI-PIECE AND SINGLE PIECE RIM WHEELS

Chapter 1 General Information KMDSI Products

DRYSUIT USER S MANUAL

Chapter 1 General Information KMDSI Products

Owner s Guide. ElevateSUP.com

Part # Balanced SCUBA Regulator Assembly for M-48 SuperMask and MOD-1 Installation Guide

Model 23H Hand Crank Seamer

Introduction to Ecoseal

Flexi-pro Aerosol Delivery System (FADS) Manual

Installation instructions for the Yepp Maxi Easyfit

BUTTERFLY VALVES Series 800

Santa Fe Cycles Assembly Guide Introduction

ROHO QUADTRO SELECT CUSHION ADJUSTMENT INSTRUCTIONS

SOTR Special Operations Tactical Respirator

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

1. Introduction Why use the Flow-Through Cell? Component Identification... 1

X-Tech CLV User Manual. English

FLEXIBLE SHAFTING (Wet & Dry)

TURF BROOM ATTACHMENT ASSEMBLY KIT

STOP. Chapter 1 General Information KMDSI Products. 1.1 Introduction. EXO Full-Face Mask Manual

1. Bridge 2. Frontal straps (RFS / LFS) 3. Thick sponge padding 4. Occipital mesh 5. Scaled rubber strap 6. Suspension arm 7. Adaptor A 8.

60 Drum Style Spike Aerator

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

15ME-014 INSTRUCTION MANUAL OF STERN TUBE SEALING TYPE EVK2RV. URL

Combination Breathing Apparatus

AIR/OVER HYDRAULIC JACK 20 TON

NORTHERN DIVER WETSUIT MANUAL

12S 1st Stage. -Maintenance Procedure-

Telefon (+45) Telefax (+45)

Regulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1

HIGH RATE BASKET STRAINER

ROPV R40 E Series User Manual

Technical Service Bulletin June 2015 TSB122.06

Thank you for choosing Xuma.

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TYPE BV2-LD

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

All rights reserved 2010 Les Fabrications TJD inc.

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

INSTRUCTIONS AND WARNING FOR SAFETY USE OF AIR TOOLS GENERAL RECOMMENDATIONS

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

THE OWNER'S MANUAL IS IN TWO VOLUMES: VOLUME 2 TECHNICAL SPECIFICATIONS - ASSEMBLY PROCEDURE ZODIAC

Right-Angle Tube Roller Model

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

Measurement Guide

SIMPLAIR PIPING TOOL. JXT Company

1.0 - OPENING AND CLOSING THE DOOR

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Transcription:

Quick Neck User Manual Photo: Jonas Dahm / Deep Sea Productions www.sitech.se

Quick Neck User Manual We want to congratulate you on your purchase of the Quick Neck system, a Dynamic and Modular Quick Change Solution developed and manufactured by SI TECH in Sweden. The Quick Neck system is designed as a modular seal attachment platform providing the opportunity to quickly change a broken, torn or aged seal. It provides you with the flexibility to choose from a variety of seals made from silicone or latex, each with different properties. Silicone Options of the seals 1. Mounting seal 1.1 Place the Lock Ring on the inside of the seal. Ensure that approximately 1,5 cm of the seal is pulled over the Lock Ring. 1.2 Put the seal in position over the Neck Ring (mounted on your drysuit) with the Lock Ring on top of the tapered groove in the Neck Ring. Seal Quick Neck Ring Latex Neck Ring Tool (old) Combi Tool (new) Components Lock Ring The system itself consist of four components: Quick Neck Ring Lock Ring Neck Ring Tool Neck Seal (silicone or latex) Benefits You can choose from a variety of seals; fabrics and sizes. If a seal breakes, you will be able to quickly solve the problem without ruining the activity of the day. A suit used by several people can easily be adjusted with correct size of seal within minutes. This manual does not address the topic of gluing/attaching the Neck Ring to your drysuit. Please visit: www.sitech.se for information. 1.3-1.4 Put the Neck Ring Tool in position as image displays. By applying force, press the Lock Ring down into the tapered groove of the Neck Ring so that the Lock Ring enters the groove and locks into position. Use a flat surface when performing this operation. 1.5 Push the Neck Ring Tool forward along the Lock Ring until all of it has been forced into the groove in the Neck Ring. (Strive to get the same amount of excess part of seal around the entire assembly, see image 1.6.)

Important information Before donning the drysuit it is of great importance to check that the Lock Ring is still fixed in its position. This must be checked every time before entering the drysuit. Make this a standard routine! Excess part of seal A A B 1.6 Ensure that the excess part of the seal is similar throughout the entire dressing. We recommend between 1,5-2 cm. 2. Detaching seal 1.7 Check that the Lock Ring is in position by following the groove 360. 1.8 After completing the seal attachment section, perform a security check: Grab the end of the seal as the image shows and pull it gently away from the joint to ensure that it is seated properly. Do not use excessive force! Simulate the same force as used when donning suit. If you notice that the Lock Ring accidently comes out of its position in the groove of the B Quick Neck Ring you must check if there is eventual damages to the Quick Neck Ring or the Lock Ring. Images marked A displays that a section of the Lock Ring of some reason have been released from its proper position. Check the Quick Neck Ring for damages before mounting the seal again. Images marked B displays the Lock Ring in its proper position fixed into the groove of the Quick Neck Ring. These are suggested instructions only Whatever method chosen, be certain the neck seal, be it latex or silicone, is properly treated. Always make a leakage and stress test on your drysuit seals before diving. 2.5 The Quick Neck Ring is designed for dynamic flexibility and will not demand tools for release of the Lock Ring and seal. You can easily release the Lock Ring by using your fingers. Grab the neck seal with one hand and bend (open) the Quick Neck Ring with the other hand. Pull firmly until the seal and Lock Ring comes loose. NOTE: Be aware of the fact that sharp finger nails might damage the seal.

3. Donning When donning a drysuit with a Quick Neck System mounted it is of great importance that you do not create unnecessary force to the Quick Neck assembly. This might cause the seal to come out of its position putting the user in danger. Find, Learn and Evolve at www.sitech.se CORRECT Grab the seal with your fingers and support with enough force to ease for your head to come through the seal. Note: INCORRECT Do not use this method when donning your drysuit. You will expose your drysuit, Quick Neck and seal to uneccessary force that might break the seal or force the seal to come loose from the Quick Neck assembly. When packing the drysuit it is of great importance that the Quick Neck assembly ends up in a flat position. If the Quick Neck assembly is packed in a twisted position it might force the Lock Ring out of the locking groove. Welcome to www.sitech.se, a powerful resource center from where you will be able of finding information about SI TECH and related products! The website contains technical specifications, articles and information not to be found in this manual. CORRECT INCORRECT

Our products have been trusted by divers for more than 40 years Maintenance and Storage Avoid exposing the seals to direct sunlight. Always clean your seals from sweat and salt water. Use talc on seals to extend the lifespan. Remove seals during long periods of storage. Spare Parts Item no. Item 60175 Quick Neck Ring 60172 Lock Ring 60160 Neck Ring Tool (old) 60165 Combi Tool (new) 61630 Silicone neck seal, circumference 28-37 cm 61631 Silicone neck seal, circumference 22-30 cm 61655-S Latex neck seal, circumference 24-32 cm 61655-M Latex neck seal, circumference 28-37 cm 61655-L Latex neck seal, circumference 35-43 cm SI TECH is a Swedish company focusing on manufacturing and marketing of components for protective suits such as; drysuits, rescue suits and garments designed for diverse hostile environments. SI TECH is rooted in the diving industry which is still the company s core market. The company was founded in 1971 by the diving pioneer Stig Insulán. Core products Modular Quick Change Solutions, Drysuit Valves, Drysuit seals, Dry Glove Systems, Gas Inflation Systems and special compoents for military purposes Inhouse capabilities Development and production is made in-house at our facilities in Brastad, Sweden. Inhouse competencies include: CAD construction, Injection Molding, CNC Machining, EMD Machining, Assembly, Sales and Marketing, Logistics and Administration. Our team of engineers, sales and marketing personell have close co-operation with the distributors and end-users of our products.

FREEDOM OF CHOICE COST EFFICIENT NO MORE REPAIRS DO IT YOURSELF ENJOY YOUR DIVING Neck Area Neck Tite Complete Solutions Large assortment of seals and gloves Quick Neck Quick Glove - Dry Glove System Quick Cuff Attachment platform Glove Lock QCP - Dry Glove System Wrist Area QCS Oval Attachment platform ANTARES - Dry Glove System

SI TECH AB Quick Neck manual Version: 1.0 April 9, 2014 www.sitech.se