Design Change Notification

Similar documents
APPS-160 Gen 2 User Manual

CRYOGENICS & LNG Application Guide

PERMA-CYL 230/450/1000/1500/2000. Installation Manual Manual # Revision B

Trifecta High-Pressure Systems

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Specialty Products. Specialty Products Index

GREIG FILTERS, INC. OPERATION MANUAL

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

MEDICAL EQUIPMENT CATALOG

CASH VALVE TYPE KP BACK PRESSURE VALVES

Product Manual APPS-160. Designed and Built by: Chart Inc th Street NW New Prague, MN USA (800)

KFI Approved. High Pressure CO2 System Technical Datasheets

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

2 Sentry MCL Installation, Operation & Maintenance

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

MHE Model 2010 Air Packer Manual

CRYOGENIC SERIES Regulators, Pressure Gauges, Shut-off Valves, Relief Valves Technology for a Better Future

Glove Box Installation Manual

Oxygen Usage Best Practice Guide

FILTER BYPASS CONTROL

NGP-250/500 Nitrogen Generator Quick Start Guide

EXPERIMENT 2 LEVEL CONTROL SYSTEM

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Product Manual. Perma-Max MicroBulk CO 2 Systems 1400 XHP, 2200, 3300, 4400, 6000 HP & 12,000 VHP. Designed and Built by: Chart Inc.

Product Manual. Cyl-Tel and Tank-Tel Liquid Level Gauges. Designed and Built by: Chart Inc th Street NW New Prague, MN USA (800)

Description Advanced Features Typical Applications

BACK PRESSURE / SUSTAINING

BAILEY CASH VALVE. Other cryogenic fluids include liquefied natural gas, fluorine, krypton, neon, methane and ethane.

Avenger Model 33M Installation & Operation Instructions

BACK PRESSURE / SUSTAINING

v. Size shall be specified on drawings.

LNG Regulator Test Kit

VT-0017 CWH OVERVIEW. intended provide PARTS NEEDED. a cryogenic tank. avoid gas from. proper PPE tanks & testing. LNG. Review.

Test Report # Rev 0. Adiabatic Compression With Constant Bleed Valve

Liquid Gas Cylinder (LGC)

CASH VALVE CRYOGENIC CONTROLS

Medical Gas Control Panel

TECHNICAL BULLETIN CRYOGENIC APPLICATION SERVICES. website:

Bermad Pressure Reducing. Model: 42T

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Installation Instructions for NP100 Series Nitrogen Control Panels

4-W GAS ODORIZER WITH POSITIVE ACTION INDICATOR GAUGE (300 PSIG) 2014 INFORMATION MANUAL SUBMITTED BY:

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

Instruction Manual Updated 7/26/2011 Ver. 2.2

MATHESON s LaserPro Gases and Gas Delivery Equipment

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Pressure Regulator B-95

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Storage Systems and Accessories

Installation & Operating Instructions for Genesys Analog Series Manifolds

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Complying with NFPA 58 Transfer Area and Bulk Plant Liquid Opening Requirements

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Rate of Flow Valve Series 120

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No

Type 92S Pilot-Operated Steam Regulator

VB-7263 Series. Application. Features. Applicable Literature

TECHNICAL DATA. than the water inlet pressure to the concentrate

Jerry Martin s Co 2 Snow Apparatus

Refrigerant Gases Valves

MFP14-PPU (Vented) Automatic Packaged Pump Units

Optimizing Gas Supply for Industrial Lasers

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

NTF-230 OPERATION MANUAL

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

Installation & Operating Instructions for Genesys Analog Series Manifolds

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

R-410A 50% R-32 50% R-125.

TECHNICAL DATA. Page 1 of 12

GasTrak Pro TM Delivery/Control Systems

SD 1520C SERIES 2000 DIRECT & REVERSE ACTING TYPE 2050 THREE WAY. DIRECT & REVERSE ACTING DIMENSIONS inches (mm) AND WEIGHTS pounds (kg)

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Pressure Equalising Valves Model , for Differential Pressure Gauges

Universal Valve Company Inc

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

Unit 24: Applications of Pneumatics and Hydraulics

CRYOGENIC PRESSURE REGULATOR

Universal Valve Company Inc

NTF-515. Operation Manual

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

DynaPak Gas Sampler S Y S T E M S U P P O R T M A N U A L DP-2000

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

ABRASIVE REGULATOR II

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Transcription:

Design Change Notification Date: November 15, 2017 Document #: DCN-112-Trifecta Gas Supply System Subject: Revised design of Trifecta 600 PSIG systems Background: Chart s continuous attention to product improvement and customer satisfaction has resulted in the design modification. The revised design is a culmination of improvements recommended by a number of customers and technicians. These same improvements will be officially released on the other Trifecta models starting in January 2018, along with a redesigned control panel. These new models will be referred to as the Trifecta Pro Series. This new design of the X- Series 600 PSIG Trifecta will be an interim product until the new Pro-Series design is released next year. The addition of a new control panel will be the only change that takes place to this 600 PSIG unit. This unit will only be available in the 15K design. Specification drawing D-21072145 is available upon request as are specific component data sheets. Products Affected: Trifecta 600 PSIG systems: Old Part Numbers 20679790 FNL Trifecta X15 600 PSI 120V X-Series 20538067 FNL Trifecta X10 600PSI 120V X-Series New Part Number FNL Trifecta X/Pro Lin- 20900990 600 15K Description: The following improvements were made to the design: o More isolation valves were added to aide in troubleshooting, preventive maintenance, and component replacement. There will now be a high flow extended stem cryogenic ball valve at the inlet of the PB (pressure building) vaporizer. Also, a 4-way valve was added to isolate the Rosemount transmitters and analog liquid level gauge. Refer to photos on next page. Page 1 of 6

High flow, extended stem, cryogenic ball valve 4-way isolation valve for transmitter and liquid level gauge Page 2 of 6

o The size of the pallet frame was increased to create more clearance for the cylinders and components. This frame is about 4 wider and 6 deeper (refer to front view picture) than the previous design. The height of the frame is unchanged. See specification drawing D-21072145 (shown in top view drawing). FRONT VIEW PICTURE TOP VIEW DRAWING o Flex hoses will now be used to connect the cylinder to the PB vaporizer inlet and on the liquid use line (see photo below). This will help reduce the stress on this section of piping caused by icing and during shipping. Stainless steel lined, stainless steel braided flex hose Page 3 of 6

o The liquid use line (Trifecta outlet) exits the cylinder from the bottom instead of through a dip tube (as shown in photo). This was done as a part of an effort to move the liquid lines lower to reduce ice build-up near the solenoids. The extra pressure from the weight of the liquid will also benefit overall performance. Liquid use line withdraws from the bottom of the tank instead of a dip tube o Needle valves (shown in photo) were added to the safety tree circuit to allow users to vent trapped pressure after cycling the safety diverter valve. Bleed valves on safety tree Page 4 of 6

o Replaced screwed bonnet Rego extended stem globe valve on the liquid use outlet with a Rego bolted bonnet globe valve (as shown in photo) that has a higher flow capacity and a longer lasting seat design. Rego bolted bonnet globe valve, Chart part number 20990231 o Flex hoses will now be used to connect the cylinder high/low phase lines to the cylinder transmitters and liquid level gauge via the 4-way isolation valve (as shown in photo). This will simplify the piping to allow for easier connections to be made when servicing the transmitters. Teflon lined, stainless steel braided flex hoses. Page 5 of 6

o Analog differential pressure gauge (shown in photo) to measure each cylinder s liquid level as a reference to the digital reading coming from the Rosemount transmitters into the PLC. Analog liquid level gauge, Chart part number 20923160 Contact: If you have questions or concerns relative to this action, please contact your Chart Customer Service Representative at (800) 400-4683. Thank you for depending on Chart to provide high product quality and service. Page 6 of 6