The Influence of Elliptical Chainrings on 10 km Cycling Time Trial Performance

Similar documents
The Reliability of a Laboratory-based 4 km Cycle Time Trial on a Wahoo KICKR Power Trainer

Congress Science and Cycling 29 & 30 june 2016 Caen. Théo OUVRARD, Julien Pinot, Alain GROSLAMBERT, Fred GRAPPE

ABSTRACT THE INFLUENCE OF BODY COMPOSITION ON CADENCE EFFICIENCY IN COMPETITIVE CYCLISTS. by Tate Bross Devlin

WHITE PAPER THE SCIENCE BEHIND NON-CIRCULAR CHAINRINGS

Myths and Science in Cycling

Innovation Report. Physiological and Biomechanical Testing of EasyPedal Pedal Prototypes. Jan 2012

Physiological demands of road sprinting in professional and U23 cycling. A pilot study

Anaerobic and aerobic contributions to 800 m and 8 km season bests

Validity and Reproducibility of the Garmin Vector Power Meter When Compared to the SRM Device

Summary of Preliminary Report on the Performance Enhancements provided by ROTOR Q-Rings Foreword

PRELIMINARY REPORT ON Q-RINGS

Assessment of an International Breaststroke Swimmer Using a Race Readiness Test

A Novel Gear-shifting Strategy Used on Smart Bicycles

Changes in a Top-Level Soccer Referee s Training, Match Activities, and Physiology Over an 8-Year Period: A Case Study

Influence of crank length on cycle ergometry performance of well-trained female cross-country mountain bike athletes

Available online at Prediction of energy efficient pedal forces in cycling using musculoskeletal simulation models

Effect of Pedaling Technique on Mechanical Effectiveness and Efficiency in Cyclists

INFLUENCE OF PEDALING TECHNIQUE ON METABOLIC EFFICIENCY IN ELITE CYCLISTS

PEDALING ANALYSIS Pedaling Analysis monitor the power output variations coordinated action the smoothness of the pedaling

Journal of Human Sport and Exercise E-ISSN: Universidad de Alicante España

Using Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking

Know your movement. Enhance your performance through biomechanics with Q RINGS & 2INpower

INVESTIGATION OF POWER OUTPUT ON A NOVEL BICYCLE DRIVE IN COMPARISON WITH THE COMMON BICYCLE DRIVE

Competitive Performance of Elite Olympic-Distance Triathletes: Reliability and Smallest Worthwhile Enhancement

Joint Torque Evaluation of Lower Limbs in Bicycle Pedaling

Comparison of Ventilatory Measures and 20 km Time Trial Performance

EFFECTS OF CHAINRING DESIGN ON PERFORMANCE IN COMPETITIVE CYCLISTS

University of Canberra. This thesis is available in print format from the University of Canberra Library.

MINERVA MEDICA COPYRIGHT

Journal of Human Sport and Exercise E-ISSN: Universidad de Alicante España

Article Title: Relationships Between Triathlon Performance and Pacing Strategy During the Run in an International Competition

OPTIMIZATION OF PEDALING POWER THROUGH NON-CIRCULAR CHAIN RING: A SYSTEMATIC REVIEW

T he multidisciplinary sport of triathlon comprises three

Evaluation of the Cyclus ergometer and the Stages power meter against the SRM crankset for measurement of power output in cycling

Relationships Between Triathlon Performance and Pacing Strategy During the Run in an International Competition

What Determines The Optimal Cadence?

External Feedback Does Not Affect Running Pace in Recreational Runners

S everal studies involving trained cyclists or triathletes

Journal of Exercise Physiologyonline (JEPonline)

JEPonline Journal of Exercise Physiologyonline

Chapter 5 Is gross efficiency lower at acute simulated altitude than at sea level?

HPA Power Transmission. Everardo Uribe

Tests of Cycling Performance

Pedaling effectiveness. Jon Iriberri & Javier Sola WKO4

Triathlon cycle-run transition: seated versus alternating seated and standing cycling

A Description of Variability of Pacing in Marathon Distance Running

Previous research has shown that the preferred

Vertical hand force and forearm EMG during a High-step Rock-on climbing move with and without added mass

The running economy difference between running barefoot and running shod

The Optimal Downhill Slope for Acute Overspeed Running

Specificity of training is perhaps the most significant

Effect of cadence selection on peak power and time of power production in elite BMX riders: A laboratory based study.

Optimization of an off-road bicycle with four-bar linkage rear suspension

Article published in: ACSM s Medicine & Science in Sports & Exercise Vol. 27, No. 4, April 1995

A Comparison of Observed Collegiate Female Cyclists to Elite Female Cyclists from a Meta-Analytic Review

Monitoring of performance an training in rowers

Practical aspects of tapering for competition in athletics. Iñigo Mujika

A Re-Examination of Running Energetics in Average and Elite Distance Runners

MUSCULOSCELETAL EFFICIENCY IN CYCLING. Dr. Harald Böhm Orthopaedic Hospital for Children Aschau im Chiemgau, Germary

Influence of Angular Velocity of Pedaling on the Accuracy of the Measurement of Cyclist Power

Kent Academic Repository

Energy Output. Outline. Characterizing Wind Variability. Characterizing Wind Variability 3/7/2015. for Wind Power Management

Unpacking Interval. Lisa A. Workman

COMPARISON OF BIOMECHANICAL DATA OF A SPRINT CYCLIST IN THE VELODROME AND IN THE LABORATORY

International Journal for Life Sciences and Educational Research. School of Physical Education, Karpagam University, Coimbatore, Tamilnadu, India

Grip Force and Heart Rate Responses to Manual Carrying Tasks: Effects of Material, Weight, and Base Area of the Container

Changes in Relative Exercise Intensity during a Two Hour Endurance Race Using a Tandem-Bicycle for Exercise

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

Journal of Exercise Physiologyonline (JEPonline)

On a track where the goal is to run a given distance

Analysis of energy systems in Greco-Roman and freestyle wrestlers participated in 2015 and 2016 world championships

Field Testing the Upright Versus the Aero Cycling Position

Purpose: Materials: Method:

Biomechanical analysis of the medalists in the 10,000 metres at the 2007 World Championships in Athletics

Variability of pacing in marathon distance running

The role of fitness testing in the evaluation of primary school running programmes

Technical Report: Accuracy Testing of 4iiii Innovations PRECISION Powermeter Technology

Validity and Reliability of the Axiom Powertrain Cycle Ergometer When Compared with an SRM Powermeter

Application Note 183. Page 1 of Aero Camino, Goleta, CA Tel (805) Fax (805)

WHAT CAN WE LEARN FROM COMPETITION ANALYSIS AT THE 1999 PAN PACIFIC SWIMMING CHAMPIONSHIPS?

For optimal performance in team sports like soccer,

Model based automated cycling ergometer

Bicycling Simulator Calibration: Proposed Framework

Influence of cycling cadence on subsequent running performance in triathletes

Training Tip of the Week. MILK: It does the body builder good!

Temporal Activity in Particular Segments and Transitions in The Olympic Triathlon

BODY FORM INFLUENCES ON THE DRAG EXPERIENCED BY JUNIOR SWIMMERS. Australia, Perth, Australia

Training Program. Definitions. Preparation for Training

Crawley, Western Australia, AUSTRALIA; 2 School of Mathematical Sciences, The University of Western Australia, Crawley, Western Australia, AUSTRALIA

Work Wearing Protective Clothing in Hot Environments: Lessons Learned from the Development of Firefighter Personal Protective Clothing Standard Test

DIFFERENCES IN PHYSICAL FITNESS IN KUMITE AND KATA PERFORMANCE BETWEEN FEMALE KARATE ATHLETES

The Match Demands of Australian Rules Football Umpires in a State-Based Competition

Metabolic production of carbon dioxide in simulated sea states: relevance for hyperbaric escape systems.

Thermal stress on firefighters in extreme heat exposure

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

SELECTION OF ROAD TRACK TO DETERMINE OPTIMIZED VALUE OF WHEEL DIMENSION AND SPEED RATIO BETWEEN CRANK AND WHEEL FOR CYCLE RICKSHAW

ScienceDirect. Long-distance, short-distance: triathlon. One name: two ways.

iworx Sample Lab Experiment HE-4: Respiratory Exchange Ratio (RER)

LEVEL OF VO2 MAX CAPACITY VOLLEYBALL PLAYERS

7 th International Conference on Wind Turbine Noise Rotterdam 2 nd to 5 th May 2017

Transcription:

Edith Cowan University Research Online ECU Publications Pre. 2011 2010 The Influence of Elliptical Chainrings on 10 km Cycling Time Trial Performance Jeremiah Peiffer Edith Cowan University Christopher Abbiss Edith Cowan University 10.1123/ijspp.5.4.459 Accepted author manuscript version reprinted, by permission, from Peiffer, J., & Abbiss, C. (2010). The Influence of Elliptical Chainrings on 10 km Cycling Time Trial Performance. International Journal of Sports Physiology and Performance, 5(4), 459-468. Original article available here.. Human Kinetics, Inc. This Journal Article is posted at Research Online. http://ro.ecu.edu.au/ecuworks/6376

International Journal of Sports Physiology and Performance, 2010, 5, 459-468 2010 Human Kinetics, Inc. The Influence of Elliptical Chainrings on 10 km Cycling Time Trial Performance Jeremiah J. Peiffer and Chris R. Abbiss The use of elliptical chainrings (also called chainwheels or sprockets) has gained considerable interest in the amateur and professional cycling community. Nevertheless, we are unaware of any scientific studies that have examined the performance benefits of using elliptical chainrings during an actual performance trial. Therefore, this study examined the influence of elliptical chainring use on physiological and performance parameters during a 10 km cycling time trial. Nine male cyclists completed, in a counterbalanced order, three 10 km cycling time trials using either a standard chainring or an elliptical chainring at two distinct settings. An attempt was made to blind the cyclists to the type of chainring used until the completion of the study. During the 10 km time trial, power output and heart rate were recorded at a frequency of 1 Hz and RPE was measured at 3, 6, and 8.5 km. Total power output was not different (P =.40) between the circular (340 ± 30 W) or either elliptical chainring condition (342 ± 29 W and 341 ± 31 W). Similarly, no differences (P =.73) in 2 km mean power output were observed between conditions. Further, no differences in RPE were observed between conditions measured at 3, 6, and 8.5 km. Heart rate was significantly greater (P =.02) using the less aggressive elliptical setting (174 ± 10 bpm) compared with the circular setting (171 ± 9 bpm). Elliptical chainrings do not appear to provide a performance benefit over traditional circular chainrings during a mid-distance time trial. Keywords: cycling, performance, cadence, testing Advancements in cycling equipment can have major implications for overall cycling performance. For instance, the progression from single and double speed bicycles to the multigeared bicycles of the present have allowed greater speeds and the ability to transverse terrains that were once impassable. With the evolution of composite materials, lighter and more aerodynamic bicycles provide performance advancements irrespective of a cyclist s ability. 1,2 Nevertheless, beyond a greater selection of gear ratios, changes to the drive train of the bicycle (chain, gears, and Jeremiah J. Peiffer is with the School of Chiropractic and Sports Science, Murdoch University, Murdoch, WA, Australia, and the School of Exercise, Biomedical, and Health Sciences, Edith Cowan University, Joondalup, WA, Australia. Chris R. Abbiss is with the School of Exercise, Biomedical, and Health Sciences, Edith Cowan University, Joondalup, WA, Australia; the Department of Physiology, Australian Institute of Sport, Belconnen, ACT, Australia; and the Division of Materials Science and Engineering, Commonwealth Scientific and Industrial Research Organisation, Belmont, VIC, Australia. 459

460 Peiffer and Abbiss crank) have be relatively nonexistent, despite the presences of biomechanically measured dead spots within the normal pedal stroke. 3 For example, during the normal pedal stroke the majority of torque is produced with the crank parallel to the ground (90 ) with very low or zero forces produced at crank positions of topdead-center (0 ) and bottom-dead-center (180 ). 3 One such attempt to reduce the time spent at top- and bottom-dead-center and increase the time in the downstroke has involved the use of elliptical chainrings (also called chainwheels or sprockets). Elliptical chainring configurations provide a greater effective ring diameter during the down stroke, theoretically resulting in greater power production during this period of the pedal stroke. 4 7 Indeed, in vitro calculations by Rankin and Neptune 6 suggest that elliptical chainrings can increase cycling power, by approximately 2.9%, over a range of cadences (60, 90, and 120 rpm). The physiological assessment of elliptical chainrings has primarily focused on cycling economy, with no differences observed between circular and elliptical chainrings in trained 4,7 or highly trained 5 cyclists. To date, no study has examined the influence of elliptical chainrings on performance in trained or untrained individuals using actual performance testing; thus, providing the need for research in this area. Therefore, the purpose of this study was to examine the submaximal physiological parameters and 10 km cycling time trial performance of cyclists while cycling with both circular and elliptical chainrings. Based on a theoretical increase in power production of 2.9% 6 we hypothesized that the use of elliptical chainrings would increase cycling performance. Participants Methods Nine trained male cyclists (age: 31 ± 6 y; body mass: 78.6 ± 4.8 kg; VO 2 max: 64.1 ± 4.4 ml kg 1 min 1 ; peak power: 450 ± 34 W) volunteered to participate in this study. Participants were required to complete four 10 km cycling time trials separated by no less than five and no greater than 10 d. Participants were asked to avoid strenuous physical activity in the 24 h before the trial and to consume a similar diet the day before and day of testing. The possible risks and benefits of participation in this study were explained to each participant and written consent was obtained before data collection. Approval from the necessary institution s Human Ethics Research Committee was obtained before the commencement of this study. 10 km Time Trials Participants were required to complete four 10 km cycling time trials using one of three chainring configurations (standard, elipitcal 1, and eliptical 2 ). All time trials were conducted on the Velotron cycle ergometer (Racermate, Seattle, USA) in an environmental chamber maintained at 24 C and 40% relative humidity. A large fan providing a wind speed of 32 km h 1 was placed directly in front (approx. 1 m) of the subjects, to provide an accurate simulation of wind speed and was started upon commencement of each trial. Before the start of each time trial participants completed a standardized 10 minute warm-up (5 min at 150 W followed by 5 min at 200 W) at a fixed cadence (90 rpm). During the warm-up expired gases were collected, each second, using a metabolic cart (Parvo TrueOne, Utah, USA). The

Elliptical Chainrings and Performance 461 average oxygen consumption for the final 2 min of each stage were recorded and used to calculate the participants cycling economy (W L 1 O 2 ). 8 This method of assessment was selected as this measure is consistent with a lower coefficient of variability (3.3%) compared with measures of gross (4.2%) and delta efficiency (6.7%). 8 In addition, heart rate was recorded at 30 s intervals and ratings of perceived exertion (RPE) were obtained at 5 min and 10 min during the warm-up. At the completion of the warm-up, participants were allowed 5 min of recovery before the start of the 10 km time trial. Information regarding the chainring use and performance times for the 10 km time trials were withheld from the participants until the completion of all four trials. In addition, a guard was affixed to the cycle ergometer that did not allow the participants to see the chainring during the time trials (Figure 1). All time trials were started from a standing start at a fixed gear ratio (53 16) and participants were instructed to finish the time trial in the shortest time possible. Participants were not provided feedback except the distance completed. During the time trials, ratings of perceived exertion were recorded at 3, 6, and 8.5 km using visual analog scales. 9 The initial 10 km time trial was completed using a standard circular chainring (53 tooth; Durace, Shimano, Japan) and was used for familiarization purposes; therefore, this data was not included in the analysis. The remaining three time trials were conducted in a counterbalanced order using one of three chainring configurations (normal, elliptical 1, or elliptical 2 ; Figure 1). The elliptical chainring used during Figure 1 Guard used to limit participant visibility of chainring (top-right and top-left) and orientation of the elliptical chainring in the elliptical 1 (bottom-left) and elliptical 2 (bottom-right) settings.

462 Peiffer and Abbiss this study (Q-rings, Rotor-Cranks, Spain) were selected as their use has gained acceptance in the amateur and professional cycling community. The design of the elliptical chainrings provided for multiple positioning of the rings and a constant eccentricity (ratio major to minor axis) of 1.10. During the trial in the elliptical 1 setting, the major axis of the chainring was offset 110 counter clockwise to the crank arm. While during the elliptical 2 trial, the major axis of the chainring was offset 100 counter clockwise to the crank arm. Data Processing During the time trial, power output (Velotron Coaching software, Racermate, USA) and heart rate (810i, Polar, Finland) were recorded at a frequency of 1 Hz. For comparison purposes, raw power output and heart rate data were converted to 2.0 km averages. Further, the mean power output for the entire 10 km time trial was recorded for analysis. Statistical Analysis Differences in the 2.0 km average power output, heart rate and the RPE measures at 3, 6, and 8.5 km between conditions were analyzed using a two-way ANOVA with repeated measures. Significant main effects or interactions were analyzed using Tukey s HSD post hoc test. In addition, differences between the submaximal variables collected during the warm-up (economy, heart rate, and RPE) were analyzed between conditions 150 W and 200 W using a two-way ANOVA. Further, the percent change in performance between the standard circular chainrings and the two elliptical chainrings were compared with the smallest worthwhile change in performance (1%), calculated from previously published coefficient of variation measurements of sustainable power during a time trial using the Velotron cycle ergometer, 10,11 as outlined by Hopkins et al. 12 All statistics were completed using Statistica (Version 7; StatSoft, USA) with the level of significance set to P <.05. Data are presented as means ± standard deviations unless otherwise noted. Submaximal Performance Results The differences in cycling economy, heart rate and RPE recorded at 150 W and 200 W are presented in Table 1. No differences were observed for cycling economy (P =.26), heart rate (P =.75) or RPE (P =.42) between the three conditions at either 150 W or 200 W. 10 km Time Trial Performance No differences in the mean power output (P =.40) were observed between conditions (Table 2). In addition, neither cycling with Elliptical 1 or Elliptical 2 improved performance beyond the smallest worthwhile change in performance (1.0%). A significant main effect for time was observed for the 2.0 km average power measures (P =.001), with greater power recorded in the first 2.0 km compared with all

Elliptical Chainrings and Performance 463 Table 1 Cycling economy, heart rate, and ratings of perceived exertion (RPE) measured during submaximal exercise at 150 W and 200 W using circular, elliptical 1 (offset 110º), and elliptical 2 (offset 100º) chainrings Circular Elliptical 1 Elliptical 2 150 W 200 W 150 W 200 W 150 W 200 W Economy (W L 1 O 2 ) 67.8 ± 3.2 73.0 ± 3.5 67.0 ± 2.5 72.5 ± 2.4 67.0 ± 2.4 73.0 ± 2.7 Heart Rate (bpm) 117 ± 12 132 ± 12 119 ± 12 134 ± 14 117 ± 12 132 ± 14 RPE 7.7 ± 1.7 8.8 ± 2.1 7.4 ± 1.7 9.1 ± 2.4 7.8 ± 1.8 9.0 ± 2.0 Table 2 Sustainable power output and completion time measured during a 10 km cycling time trial using circular, elliptical 1 (offset 110º), and elliptical 2 (offset 100º) chainrings Circular Elliptical 1 Elliptical 2 % C-E1 % C-E2 Power Output (W) 340 ± 30 342 ± 29 341 ± 31 0.67 ± 0.01 0.40 ± 0.02 Note. % = Percent change; C-E1 = Circular vs. Elliptical 1 ; C-E2 = Circular vs. Elliptical 2. other time points (Figure 2). The analysis of the 2.0 km average cadence produced a significant main effect for time (P =.001). Cadence was significantly greater at 2 km and 4 km compared with all other time points (Figure 2). Significant main effects for time (P =.001) and chainrings (P =.02) were observed for the 2.0 km average heart rate values. During cycling with the Elliptical 1 chainring, the average heart rate was significantly greater (174 ± 10 bpm) compared with the circular chainring condition (171 ± 9 bpm). Further, in all conditions the 2.0 km average heart rate was significantly less in the first 2.0 km compared with all other time points (Figure 2). No differences in the ratings of perceived exertion were observed between conditions; however, a main effect for time was observed (P =.001) with greater RPE values measured at 6 km (16.7 ± 1.7) compared with 3 km (14.9 ± 2.1), and greater RPE values at 8.5 km (18.0 ± 1.8) compared both the 6 km and 3 km measurement points. The individual percent change in power output between the elliptical chainrings and the normal chainring are presented in Figure 3. A performance enhancement was observed for most participants when using an elliptical chainring compared with the circular chainring. Nevertheless, only four of the nine participants increased performance beyond the smallest worthwhile performance change (1%). Discussion The purposes of this study were to examine the influence of elliptical chainrings on submaximal physiological responses to cycling and cycling performance during a 10 km time trial. The major findings from this study were: 1) average power output over the entire 10 km time trial was not different between chainring configurations, 2)

464 Peiffer and Abbiss Figure 2 Average 2 km power output, heart rate, and cadence measured during a 10 km cycling time trial using circular ( ), elliptical 1 ( ; offset 110 ) and elliptical 2 ( ; offset 100 ) chainrings. *Main effect for time, values less than all preceding; # main effect for time, values greater than all preceding; main effect for condition, elliptical 1 > circular.

Elliptical Chainrings and Performance 465 Figure 3 Individual percent change in sustainable power between circular and elliptical 1 (top) and circular and elliptical 2 (bottom) chainrings. Dash line = smallest worthwhile change to provide a performance enhancement; box and whiskers = mean percent change ± 95% confidence interval. heart rate was greater during the 10 km time trial with elliptical 1 setting, compared with the circular condition, and 3) when examining the smallest worthwhile change in performance a high between subject variability was observed when using elliptical chainrings. Previous elliptical chainring studies have focus primarily on the submaximal benefits associated with the use of these devices. 4,5,7 Similar to past research, 4,5,7

466 Peiffer and Abbiss this study examined the submaximal benefits of elliptical chainrings and observed no differenced in heart rate, cycling economy or RPE when using elliptical compared with circular chainrings (Table 1). In addition to measuring the submaximal influences of elliptical chainrings, we also examined the performance benefits of using elliptical chainrings during a 10 km cycling time trial. Our data indicates that elliptical chainrings provide no benefits to cycling performance over existing circular chainrings during a 10 km time trial. In this study we observed similar sustainable power output and completion times for the 10 km time trial during all trials (Table 2). In addition, when compared with the smallest worthwhile performance enhancing change in sustainable power, 12 neither elliptical chainring provided benefits. It is possible that our results were influenced by our selection of elliptical chainrings. Rankin and Neptune 6 modeled the performance benefits of using elliptical compared with circular chainrings at 60, 90, and 120 rpm and observed a significant increase in power of 2.9% when using the elliptical chainrings. Further, Rankin and Neptune 6 determined the most optimal elliptical chainring shape to have an eccentricity of 1.29. In the present study, we used commercially manufactured elliptical chainrings with a predetermined eccentricity of 1.10. It is possible that the eccentricity of our elliptical chainring was too small and therefore responsible for the lack of differences in sustainable power output observed between the three conditions. While no differences in sustainable power output (Table 2), 2 km average power output (Figure 2) or RPE was observed between conditions, significantly higher heart rates were recorded during the elliptical 1 trial when compared with the circular trial (Figure 2). This finding indicates a greater cardiovascular strain when using the elliptical 1 setting. 13 We speculate that the positioning of the chainrings major axis (110 counter clockwise to crank arm) might have been responsible for the increase in heart rate. During the elliptical 1 setting, the influence of the major axis would have occurred later within the greatest power producing zone of the pedal stroke (90 180 ), possibly requiring greater muscle activation, 6 thus promoting a higher heart rate. 14 Nevertheless, we did not measure muscle activity and therefore cannot confirm or deny this hypothesis. Further, we did not measure hydration status before each time trial; therefore, we cannot deny that a greater level of pretrial hypohydration was present which could have influenced heart rate. Although we did not observe a statistical increase in performance during cycling with either the elliptical 1 or elliptical 2 setting, we cannot entirely refute the efficacy of the chainrings. Analysis of the individual changes in sustainable power between the two elliptical chainrings and the circular chainring indicate a highly variable performance effect (Figure 3). For instance, four of the nine participants recorded a performance enhancement greater than the smallest worthwhile change in sustainable power 12 needed to enhance performance when using at least one of the elliptical chainrings. Further, only two individuals did not demonstrate a positive change in sustainable power when using at least one of the elliptical chainrings. For this reason, we suggest that the influence of elliptical chainrings on cycling performance is dependent on the individual and further studies are needed to highlight the interpersonal differences that can influence the effectiveness of elliptical chainrings.

Elliptical Chainrings and Performance 467 Conclusion In conclusion, we demonstrated that the use of elliptical chainrings does not increase sustainable power during a 10 km cycling time trial in a group of trained male cyclists. Further, no noticeable differences were observed in cycling economy or heart rate at two submaximal workloads. Nevertheless, considerable variability in the percent change of sustainable power for the elliptical and circular chainring settings was observed between participants. These findings indicate that the use of elliptical chainrings do not enhance cycling performance; however, this should be determined on a cyclist to cyclist basis. Practical Application The margin for victory in professional and amateur cycling can often be measured in seconds. For this reason, specialized equipment that has the potential to improve performance should be a welcomed addition to both athletes and coaches. Although the use of elliptical chainrings did not enhance 10 km cycling performance in our group of trained cyclists, the between subject variability in performance should be considered by those interested in using this device. Therefore, we suggest that cyclists should individually assess the efficacy of using elliptical chainrings to enhance their cycling performance. References 1. Faria EW, Parker DL, Faria IE. The science of cycling: factors affecting performance - part 2. Sports Med. 2005;35:313 337. 2. Jeukendrup AE, Martin J. Improving cycling performance: how should we spend our time and money. Sports Med. 2001;31:559 569. 3. Rossato M, Bini RR, Carpes FP, Diefenthaeler F, Moro AR. Cadence and workload effects on pedaling technique of well-trained cyclists. Int J Sports Med. 2008;29:746 752. 4. Hull ML, Williams M, Williams K, Kautz S. Physiological response to cycling with both circular and noncircular chainrings. Med Sci Sports Exerc. 1992;24:1114 1122. 5. Cullen LK, Andrew K, Lair KR, Widger MJ, Timson BF. Efficiency of trained cyclists using circular and noncircular chainrings. Int J Sports Med. 1992;13:264 269. 6. Rankin JW, Neptune RR. A theoretical analysis of an optimal chainring shape to maximize crank power during isokinetic pedaling. J Biomech. 2008;41:1494 1502. 7. Ratel S, Duche P, Hautier CA, Williams CA, Bedu M. Physiological responses during cycling with noncircular Harmonic and circular chainrings. Eur J Appl Physiol. 2004;91:100 104. 8. Peiffer JJ, Abbiss CR, Chapman D, Laursen PB, Parker DL. Physiological characteristics of masters-level cyclists. J Strength Cond Res. 2008;22:1434 1440. 9. Borg GA. Psycholphysical bases of perceived exertion. Med Sci Sports Exerc. 1982;14:377 381. 10. Abbiss CR, Levin G, McGuigan MR, Laursen PB. Reliability of power output during dynamic cycling. Int J Sports Med. 2008;29:574 578.

468 Peiffer and Abbiss 11. Sporer BC, McKenzie DC. Reproducibility of a laboratory based 20-km time trial evaluation in competitive cyclists using the Velotron Pro ergometer. Int J Sports Med. 2007;28:940 944. 12. Hopkins WG, Hawley JA, Burke LM. Design and analysis of research on sport performance enhancement. Med Sci Sports Exerc. 1999;31:472 485. 13. Earnest CP, Jurca R, Church TS, Chicharro JL, Hoyos J, Lucia A. Relation between physical exertion and heart rate variability characteristics in professional cyclists during the Tour of Spain. Br J Sports Med. 2004;38:568 575. 14. Taylor JA, Chase PB, Enoka RM, Seals DR. Cardiovascular adjustments to rhythmic handgrip exercise: relationship to electromyographic activity and post-exercise hyperemia. Eur J Appl Physiol Occup Physiol. 1988;58:32 38.