OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

Similar documents
Stainless Steel 142 mm Filter Holder YY

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Avenger Model 33M Installation & Operation Instructions

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

MEDICAL EQUIPMENT CATALOG

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

SC HYDRAULIC ENGINEERING CORPORATION

FLOW CONTROL & AIR PILOT SWITCH VALVES

CVS10 Sanitary Check Valves

ADAPTABILITY & PRECISION

Assembly and Installation Procedures

1020 Industrial Drive, Orlinda, TN fax

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

VERTICAL BLADDER TANK

Solvent Resistant Stirred Cells for Ultrafiltration and Filtration Applications

PLUMBING WATER & GAS TRADE CATALOGUE

HORIZONTAL BLADDER TANK

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Manual Solvent Purification System. Innovative Technology, Inc.

Low-pressure diaphragm pumps for product feeding Feeding

ANDERSON GREENWOOD. Provides reliable overpressure protection in a cost effective package. Flow Control

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

MATHESON s LaserPro Gases and Gas Delivery Equipment

DECLARATION OF INCORPORATION

1200 Series Pressure Regulators

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Filtration FILTRATION PRODUCT TIPS

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Models: C62/63/64-A/D

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Propor tional Re lief Valve s

FloWash. Industrial Filter Cart

Concentration and diafiltration of viral antigens with SmartFlow TFF

Constant Pressure Crude Oil Container Model CPCCP

Proportional Relief Valves

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

1805 Series Relief Valves

INSTRUCTIONS PARTS LIST

Tank Blanketing Pressure Regulators RHPS Series

Back Pressure Regulator

Horizontal Bladder Tanks

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

New AQF Filter Polymer Filtration System

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

DuraSite 3000 Sample Vessel User's Guide. Version Rev-1

Vertical Bladder Tanks

HP/UHP Spring-Loaded Regulator

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Mark 958 Series Sanitary Gas Back Pressure Regulators

CSA Sample Draw Aspirator Adapter Operator s Manual

Storage Systems and Accessories

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Directions for Use. Vivaflow 50 50R

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

GROUTEC SCOTT VICKERS. Grouting Equipment

TECHNICAL DATA. Trimpac 244a. September 16, 2013

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

TECHNICAL DATA. than the water inlet pressure to the concentrate

User Guide. Amicon Stirred Cells. Cat. No. UFSC05001, 50 ml UFSC20001, 200 ml UFSC40001, 400 ml

Summary of the MRA LPG Codes of Practice

NeoNatalie Resuscitator Oxygen kit

Operating Instructions

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Life Sciences. Pressure control solutions for your industry.

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Model MTB-ASME Vertical Bladder Tanks

PORTABLE AFTERCOOLER MODEL CA-700 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL ORIGINAL INSTRUCTIONS

User Manual. ECC-Opto-Gas. Release Electrochemical test cell EL-CELL GmbH

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Noth American 7347 High Pressure Gas Regulators

(AS AT 31 st MARCH, 2002)

Light Commercial Reverse Osmosis System. EE-1000 Manual

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

AIRMASTER SERIES RF AUTOMATIC DEWATERING VALVES. For the purging of water from compressed air systems WHERE DO YOU NEED AUTOMATIC DEWATERING VALVES

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

HIGH FLOW HIGH PRESSURE PUMP type BMS

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Freedom8 ShoeBox Compressor Manual

CASH VALVE TYPE KP BACK PRESSURE VALVES

Vertical and Horizontal Bladder Tanks

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

ACCU-MIX 1200 / / 26270

Transcription:

Lab scale nanofiltration equipment The METcell Range OVERVIEW METCELL SPECIFICATIONS The METcell range of equipment was designed by us to be an easy entry point for scoping separations process development at lab scale, using flat sheet membranes. The range includes the METcell System, for dead-end filtration, and the METcell CrossFlow System, for crossflow filtration. NOTE: The METcell System is sold without the magnetic plate and volumetric cylinder The METcell is a stainless steel, high-pressure stirred cell and is suitable for reverse osmosis (RO) and nanofiltration (NF) separations using aqueous and non-aqueous solvents. The MET Gas unit is supplied with the METcell to allow simple connection to a gas cylinder. All components of the assembled system are pressure rated to 69 bar (1000 psi). NOTE: The METcell System is pressurized with high pressure gas (usually N2). Please ensure that you have an adequate high pressure gas cylinder (200 bar) available and appropriate tubing to connect the cylinder to the METcell System. Evonik Resource Efficiency GmbH METcell April 2017 1/5

Technical Specification MET Gas Unit Operating Parameters Gas Unit frame: Pressure relief spring kit Membrane Size: 90 mm diameter (area = 63.6 cm²) Isolation valve: Vent valve Active Membrane Size: Processable Volume: 81 mm diameter (area = 51 cm²) 250 ml Pressure regulator: Inlet: Discharge: 0-69 barg 1/8 O.D. tube 1/4 O.D. hose (supplied) Hold-up Volume: ~5 ml Pressure relief valve: Set to relieve at 65 barg Maximum Pressure: Pressure: 69 barg (1000 psig) Pressure gauges for gas supply pressure and METcell pressure Pipework Kit (comprising tubing, elbow, tees and union) Maximum Temperature: Material Compatibility: Connections Permeate Outlet: Pressure Inlet: Feed Inlet: Wetted Materials Cell body: Dimensions The lower of 50ºC or the temperature at at which the vapour pressure of the solvent solvent exceeds exceeds 1.5 bar 1.5 absolute. bar absolute. The material is tolerant to all aqueous and The organic material solvents is tolerant compatible to all aqueous with and 316 organic stainless solvents steel compatible (SS) and Viton with or 316 Perlast. stainless steel (SS) and Viton or Perlast. 1/8 diameter 316 SS Tubing 1/4 NPT (female) 1/4 NPT (female) FEP Coated Viton and Perlast Stirrer bar: PTFE coated magnet with 316 SS support arms Cell Diameter: Cell Height: 64 mm, flaring to 120 mm 171 mm (including additional height of reinforced cell top) Features The key design features are described below: 1. The METcell System is designed to comply with the European Pressure Directive requirements, and the materials of construction are in compliance with FDA current good manufacturing practice (cgmp). 2. Easy-to-use design, with easily removable top to charge feed solution, and easily removable base for membrane replacement. 3. Safe operation up to 69 bar with high pressure mechanical couplings (ASME BPE 1997 compliant) and seals, enabling RO and NF separations to be carried out. 4. Provision of fittings for connection to a pressure source (gas cylinder-recommended). 5. Pre-assembled MET Gas unit including an isolation valve, vent valve, pressure regulator, pressure relief valve, and pressure gauges to allow safe and simple operation of a high pressure system. 6. Connection port for an HPLC pump, allowing charging of solutions into the METcell without opening the cell, particularly useful when solutes are oxygen/moisture sensitive or when continuous operation is required, e.g. permeate recycle. 7. A 35mm-wide removable PTFE coated stirrer bar is used to promote excellent mixing down to low liquid volume holdups. 8. All components can be sterilized or autoclaved as part of a cleaning procedure. Evonik Resource Efficiency GmbH METcell April 2017 2/5

9. The METcell can house membrane disks with diameter between 90 and 93 mm. A4 sheets from the PuraMem and DuraMem range of solvent nanofiltration membranes are available with various molecular weight cut-off (MWCO) grades (please ask for specifications). 10. Processing times will vary depending on membrane flux. As an indication, with a PuraMem membrane in methanol, giving a flux of 100 L.m-2.h-1, a METcell would process 100 ml in approximately 12 minutes. A comprehensive instruction manual in paper and electronic format is supplied with each METcell System. METCELL CROSSFLOW SPECIFICATION More choice - in addition to the dead-end filtration capability provided by the METcell System, the CrossFlow System lets you carry out, for example, crossflow filtrations for concentrating solutions up to 0.8 L or carrying out diafiltrations (adding fresh solvent with an HPLC pump). Greater flexibility the membrane area can be easily increased or decreased as required for your tests by changing the number of crossflow filtration cells connected in series. For instance, six 4 crossflow cells (with total area 306 cm2) or six 2.5 crossflow cells (with total area 84 cm2) can be connected in series with a system pressure drop of < 1 barg (based on a solution of 1 cp viscosity). More tests per experiment take advantage of having multiple crossflow cells available, so you can test either several discs of one membrane type or several types of membrane simultaneously with the same solution in just one experiment. NOTE: The METcell CrossFlow System is sold without the magnetic plate The METcell CrossFlow System uses the core components of the METcell System to upgrade the standard dead-end METcell filtration unit into a CrossFlow system. This system can be equipped with up to 6 crossflow cells in series with less than 1 bar pressure drop (1 cp solution viscosity). NOTE: (i) - The METcell CrossFlow System is pressurized with high pressure gas (usually N2). Please ensure that you have an adequate high pressure gas cylinder (200 bar) available and appropriate tubing to connect the cylinder to the METcell CrossFlow System. (ii) -The METcell CrossFlow System may be operated in continuous mode using a recirculation HPLC pump NOT included in this quote please contact us if this operating mode is required. More scalable data obtain results that provide a better prediction for scaling-up, particularly with concentrated or viscous solutions and solutions that generate significant concentration polarisation layers results from crossflow filtration experiments will provide flux and rejection data more consistent with process-scale membrane elements. Same high degree of safety - the METcell CrossFlow System, like the METcell System, is designed following EN13445 to fully comply with the requirements of the European Pressure Equipment Directive (97/23/EC) use of the crossflow kit will maintain the pressure rating and integrity of your METcell. Same ease of use like the METcell, the MET crossflow cells provide safe and easy operation up to 69 bar with high pressure mechanical couplings (ASME BPE 1997 compliant) and seals, as well as the flexibility of using swage process connections throughout. Easy installation Evonik MET will provide you with a complete set of hoses, fittings, clamps, etc. to get you up and running with crossflow. No annoying delays whilst specifying and waiting for ancillary parts to be delivered you can be running in crossflow on the same day you receive our kit! Evonik Resource Efficiency GmbH METcell April 2017 3/5

SYSTEM DESCRIPTION The METcell CrossFlow System contains the following: TECHNICAL SPECIFICATION System High-pressure crossflow filtration cells (316 stainless steel) Gear pump (organic solvent compatible) METcell tank base (316 stainless steel) All necessary flexible hoses and fittings A photograph and schematic of a METcell with the CrossFlow System installed are shown overleaf in Figures 1 and 2 respectively. The METcell tank base is used to replace the standard METcell base and converts the METcell into a reservoir for the filtration solution. Like in the METcell System, the filtration pressure is provided by gas pressure from a cylinder and is accurately controlled with the MET Gas Unit, as provided with the METcell System. The METcell CrossFlow System is particularly suited for reverse osmosis (RO) and nanofiltration (NF) separations, using aqueous or non-aqueous solvents. The MET crossflow cells feature a clamped design to allow quick and easy membrane changeover. All components of the assembled CrossFlow System are pressure rated to a minimum operating pressure of 69 barg (1000 psig). The standard METcell CrossFlow System is supplied with either: 3 x 4 crossflow cells (153 cm2 total membrane area), or 3 x 2.5 crossflow cells (42 cm2 total membrane area). Maximum/Minimum Working Volume: Maximum/Minimum Working Pressure: Maximum Operating Temperature: Hold-Up Volume: Pump Delivery Rate: Pump Motor: Maximum Filtration Cells in Series: Approximate System Dimensions: Materials of Construction METcell and METcell tank base: MET crossflow cells: MET crossflow cell 800/150 ml 69/5 barg (1000/70 psig) The lower of 50 ºC or the temperature at which the vapour pressure of the solvent exceeds 1.5 barg absolute. 60 ml for two 4 cells, 40 ml for three 2.5 cells 1.2 L/min 230V, 0.25 kw ATEX, NEMA and other motor types available on request Six 4 cells or six 2.5 cells (for <1 barg pressure drop with a 1 cp solution) For the two 4 or three 2.5 crossflow cells systems, the dimensions are 70 (w) x 70 (d) x 40 (h) cm FEP coated Viton and Viton or Perlast FEP coated Viton and Viton or Perlast Fittings: Flexible Hoses: and PTFE Pump wetted parts:, PTFE and Ryton (PPS) Evonik Resource Efficiency GmbH METcell April 2017 4/5

3 4 2 1 1- Gas inlet connected to METcell Top* 2 - Gas inlet connected to METcell Top* 3 - Gas Pressure Unit* 4 - METcell Tank Base 5 - Magnetic Stirrer and Hotplate (Provided by user) 6 - Permeate Collection (Provided by user) 7-2.5 Filtration Cells 8 - Gear Pump 5 6 7 7 6 8 Figure 1 - Assembled METcell CrossFlow System (* - Parts from METcell System) Disclaimer This information and all technical and other advice are based on Evonik s present knowledge and experience. However, Evonik assumes no liability for such information or advice, including the extent to which such information or advice may relate to third party intellectual property rights. Evonik reserves the right to make any changes to information or advice at any time, without prior or subsequent notice. Evonik disclaims all representations and warranties, whether express or implied, and shall have no liability for, merchantability of the product or its fitness for a particular purpose (even if Evonik is aware of such purpose), or otherwise. Evonik shall not be responsible for consequential, indirect or incidental damages (including loss of profits) of any kind. It is the customer s sole responsibility to arrange for inspection and testing of all products by qualified experts. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of the corresponding product, and does not imply that similar products could not be used. Figure 2- Schematic for METcell CrossFlow System Evonik Resource Efficiency GmbH High Performance Polymers Paul-Baumann-Straße 1 45772 Marl Germany Phone +49 02365 49-4800 emet@evonik.com www.puramem.com Evonik Resource Efficiency GmbH METcell April 2017 5/5