Detaillierte Fotodokumentation siehe Anlage zu diesem Bericht

Similar documents
TEST REPORT EN Degrees of protection provided by enclosures (IP Code)

Part I of II Auftrags-Nr.: Order No.: Unterschrift Signature. Date

IEC Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Consumer Products Services Germany GmbH Türkheim Germany

Guidelines to the standard IEC60601

to use the European Mark Licence No Date of issue: Wien, Rev. No. 03 Wien,

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

Prewired position switches FA series

VLT 2000 Series. How to size your VLT

IEC Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Key Comparison of Safety Requirements in Europe, North America and Australia for Electronic Products

Certificate of conformity Power generation unit PIKO 1.5 MP, 2.0 MP, 2.5 MP, 3.0 MP, 3.6 MP, 4.2 MP

Manual Power relay SR853

REPORT EN :2007+AC:2011 Low voltage switchgear and controlgear - Part 1:General rule

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

Position switches FP series

FMAC Sine FMAC Sine DCL

age 2 Of 4 List of Attachments (including a total number of pages in each attachment) Document No. Documents included / attached to this report (descr

K Nadelkränze / K Needle Roller Bearing

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

TEST REPORT IEC / EN Degrees of protection provided by enclosures (Ip code)

CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB Audio, video and similar electronic apparatus Safety requirements

Proportional Directional Valve System

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

INSTALLATION GUIDE Gas Rangetops

PIKO IQ 4.2, Plenticore plus 4.2 Rating: 10,0kW 8,5kW 7,0kW 5,5kW 4,2kW Rated voltage: PIKO IQ 8.5, Plenticore plus 8.5

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Intertek Testing Services Taiwan Ltd.

DC/DC Converter. Test item description...:

Prewired position switches FA series

Classification according to PED 97/23/EG results in categories, depending on:

Raising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

ASSE International Product (Seal) Listing Program

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Stand-Alone Bubble Detection System

Efficient EMC Solutions

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES

MAKING ELECTRICAL A GUIDE ON HOW TO INSPECT AND TEST PORTABLE APPLIANCES SAFELY AND EFFECTIVELY

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15

Types and approvals. Page 1/6. Data Sheet

Pressure switch KP-E. Data sheet

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Technical Data. Dimensions

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

Harmonised standards used IEC kg 0.95 kg 0.90 kg 1.34 kg

Technical Information Conducal CLY421

Test Report. No.: EM FE003 Date:Sep.02,2016 Page 1 of 6. : Aug.30,2016 ~ Sep.02,2016

Certificate of compliance

Photometric Test Report

Tightness controls TC 1 3 and TC 4

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

TEST REPORT IEC / EN Degrees of protection provided by enclosures (Ip code)

FEATURES AND BENEFITS. Meets UL/EN/IEC , 4Th ed. For EMC*

IEC :2012 Risk Management Client Completion Form

Technical Data. Dimensions

Differential pressure controls, Type MP 54, 55 and 55A

X2 Metallized Polypropylene Film Capacitor JFV

Medium voltage standard-duty, heavyduty, and extreme-duty single-phase, unfused capacitor units and accessories

SIGRAFLEX MF Approvals/Test reports

QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems

Operating Instructions

PECIMEN IMM6. Minor Electrical Installation Works Certificates. Amd 3: In accordance with BS 7671

MS52XX-C&T SMD Pressure Sensor

MULTILAYER CERAMIC CHIP CAPACITORS

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100

Zelio Relays RSL Slim Interface Plug-In Relays

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Gas density monitor With integrated transmitter Model GDM-100-TI

GENERAL APPLICATION NOTES

Customer Responsibilities

Qualification of Fastrak & First Gen Product to Railway applications Shock and Vibration Standard EN 61373

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

PRODUCT CONFORMITY CERTIFICATE

D62 - D63 Directional Control Valve l/min

COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW

GEMS SENSORS & CONTROLS

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Technical Standard Order

Spare parts list ( ) Spare parts list HD 1090

STAGE, STADIUM & X-TREME SHOT.

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Supplementary Certificate of Approval. No S433

EX-RECESSED CEILING LIGHT FITTINGS

Department of Electrical Engineering & Computer Science. Electrical Safety. for Staff and Students in EECS Instructional Laboratories

X2 Metallized Polypropylene Film Capacitor JFV

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Annex 01 to Certificate IECEx LCI X issue 10

Transcription:

Produkte Products Prüfbericht-Nr.: Test Report No.: Kunden-Referenz-Nr.: Client Reference No.: 16072518 002 Auftrags-Nr.: Order No.: N/A Auftragsdatum: Order date: 174051339 Seite 1 von 11 Page 1 of 11 15.06.2016 Auftraggeber: Client: Prüfgegenstand: Test item: Bezeichnung / Typ-Nr.: Identification / Type No.: Auftrags-Inhalt: Order content: Prüfgrundlage: Test specification: Wuxi Sans Electronic Co., Ltd. Industrial WuYi, DongGang Town, Wuxi, Jiangsu, P.R.China Li-ion Battery Charger SSLC084V42J, SSLC058V29J Alternative components for GS mark EN 60335-1:2012+A11:2014 EN 60335-2-29:2004+A2:2010 EN 62233:2008 AfPS GS 2014:01 Wareneingangsdatum: Date of receipt: Prüfmuster-Nr.: Test sample No.: Prüfzeitraum: Testing period: Ort der Prüfung: Place of testing: Prüflaboratorium: Testing laboratory: Prüfergebnis*: Test result*: geprüft von / tested by: 15.06.2016 A000379219-001 15.06.2016-27.06.2016 See page 3 TÜV Rheinland (Guangdong) Ltd. Pass Detaillierte Fotodokumentation siehe Anlage zu diesem Bericht Detailed photo documentation see appendix to this report kontrolliert von / reviewed by: 2016-6-29 Carpent Rao /Engineer 2016.06.29 Datum Name / Stellung Unterschrift Datum Date Name / Position Signature Date Sonstiges / Other: N/A Dono Zhou/Technical Certifier Name / Stellung Unterschrift Name / Position Signature Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Guangdong) Ltd. No.199 Kezhu Road, Guangzhou Science City, Guangzhou 510663, Guangdong Province P.R. China

Page 2 of 11 Report No.:< 16072518 002 > Test item description... : Trade Mark... : Li-ion Battery Charger Model/Type reference... : Ratings... : Copy of marking plate: SSLC084V42J, SSLC058V29J AC input: 100-240V, 47-63Hz, 1.8A, DC output: 42V, 2A for SSLC084V42J AC input: 100-240V, 47-63Hz, 1.4A, DC output: 29.4V, 2A for SSLC058V29J The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. Remarks: ID 1419033385

Page 3 of 11 Report No.:< 16072518 002 > Summary of testing: 1. The samples are tested and found to be complied with the requirements of standards listed on cover page 2. Tests of clause 22, 24, 29 have been carried out on model SSLC084V42J, Other tests could be covered by original report16072518 001. Therefore, this report must be read in conjunction with the original report 16072518 001. 3. For EMF requirements, all required tests have been performed and passed. Please refer to test report 16072518 001. 4. The appliances were tested according European harmonized standards. Testing location: TUV Rheinland (Guangdong) Ltd. No.199 Kezhu Road, Guangzhou Science City 510663, Guangzhou, CHINA Test item particulars... : Classification of installation and use... : Portable appliance and household indoor use Supply Connection... : Appliance inlet... :... : Possible test case verdicts: - test case does not apply to the test object...: N/A - test object does meet the requirement...: P (Pass) - test object does not meet the requirement...: F (Fail) Testing...: Date of receipt of test item...: See cover page Date (s) of performance of tests...: See cover page

Page 4 of 11 Report No.:< 16072518 002 > General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator. 1. This report is based on report 16072518 001 for the following changes: 1.1 Changing package of D4 and PCB layout for the changing package of D4 for all models, see photo documentation for detail. 1.2 Adding magnetic bead on pin of D4 for all models, see photo documentation for detail. 1.3 Adding alterative certified X capacitor and Y capacitor for all models as below: Object / part No. Manufacturer/ trademark X-Capacitor CX1 (alternative) X-Capacitor CX2 (alternative) Y-Capacitor CY1, CY2, CY5 Shenzhen Weidy Industrial Development Co., Ltd. Shenzhen Weidy Industrial Development Co., Ltd. Anshan Kei Fat Electronic Ceramic Technical Co., Ltd. Type / model Technical data Standard Mark(s) of conformity MKP 0.47uF, 310V, X2, 40/110/56/B MKP 0.1uF, 310V, X2, 40/110/56/B CT7 4700pF, 400Vac, Y1, 25/125/21 EN 60384-14 EN 60384-14 EN 60384-14 VDE VDE VDE 2. Construction for all alternative components listed in table 24.1 was considered in this report. 3. The requirements of AfPS GS 2014:01 have been considered in this report. The risk analysis, categorization and evaluation indicate that the product complies to AfPS GS 2014:01. For PAHs requirements, see material list for PAH risk assessment in test report 16072518 001 for detail. 4. EN 60335-1:2012/AC:2014 is considered and passed. 5. All relevant EK-decisions have been considered. 6. Foreseeable use was considered. Currently neither a safeguard clause procedure has been invoked nor is an increase in accidents known for this/these product(s). 7. Factory: Wuxi Sans Electronic Co,. Ltd. Industrial WuYi, DongGang Town, Wuxi, Jiangsu, P.R. China

Page 5 of 11 Report No.:< 16072518 002 > General product information: 1. The appliance is class I appliance and for household use only. 2. The differences between the two models are listed as below table A. Table A: No. Model Input Voltage (V) Rated frequency (Hz) Input current (A) Rated Output Voltage (V) Rated Output Current (A) Difference 1 SSLC084V42J AC100-240V 47-63Hz 1.8A DC42V 2A Output 2 SSLC058V29J AC100-240V 47-63Hz 1.4A DC29.4V 2A circuit

Page 6 of 11 Report No.:< 16072518 002 > 22 CONSTRUCTION P 24 COMPONENTS P 29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION P

Page 7 of 11 Report No.:< 16072518 002 > 29.1 TABLE: Clearances P Rated impulse voltage (V): Overvoltage category... : II Min. cl Basic Type of insulation: Supplementary Reinforced Functional Verdict / Remark 330 0,2* / 0,5 / 0,8** N/A N/A N/A N/A N/A 500 0,2* / 0,5 / 0,8** N/A N/A N/A N/A N/A 800 0,2* / 0,5 / 0,8** N/A N/A N/A N/A N/A 1 500 0,5 / 0,8** / 1,0*** N/A N/A N/A N/A N/A 2 500 1,5 / 2,0*** 4.2 3.6 N/A 2.6 P 4 000 3,0 / 3,5*** N/A N/A 6.5 N/A P 6 000 5,5 / 6,0*** N/A N/A N/A N/A N/A 8 000 8,0 / 8,5*** N/A N/A N/A N/A N/A 10 000 11,0 / 11,5*** N/A N/A N/A N/A N/A Supplementary information: *) For tracks on printed circuit boards if pollution degree 1 and 2 **) For pollution degree 3 ***) If the construction is affected by wear, distortion, movement of the parts or during assembly Basic 1): Difference pin of Y capacitors(cy1), Cr=Cl=4.2mm Functional 2): L/N in front of current fuse, Cr=Cl=2.6mm Supplementary 3): Difference pin of Y capacitors (CY2), Cr=Cl=3.6mm Reinforce 4): Primary winding to secondary winding (min), Cr=Cl=7.0mm Primary circuit to secondary circuit (min), Cr=Cl=8.1mm Primary circuit to accessible enclosure (min), Cr=Cl=6.5mm

Page 8 of 11 Report No.:< 16072518 002 > 29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P Working voltage (V) Creepage distance Pollution degree 1 2 3 Type of insulation I II IIIa/IIIb I II IIIa/IIIb* B** S** R** Verdict 50 0,18 0,6 0,85 1,2 1,5 1,7 1,9 N/A 50 0,18 0,6 0,85 1,2 1,5 1,7 1,9 N/A 50 0,36 1,2 1,7 2,4 3,0 3,4 3,8 N/A 125 0,28 0,75 1,05 1,5 1,9 2,1 2,4 N/A 125 0,28 0,75 1,05 1,5 1,9 2,1 2,4 N/A 125 0,56 1,5 2,1 3,0 3,8 4,2 4,8 N/A 250 0,56 1,25 1,8 2,5 3,2 3,6 4,0 4.2 N/A 250 0,56 1,25 1,8 2,5 3,2 3,6 4,0 3.6 N/A 250 1,12 2,5 3,6 5,0 6,4 7,2 8,0 6.5 N/A 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N/A 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N/A 400 2,0 4,0 5,6 8,0 10,0 11,2 12,6 N/A 500 1,3 2,5 3,6 5,0 6,3 7,1 8,0 N/A 500 1,3 2,5 3,6 5,0 6,3 7,1 8,0 N/A 500 2,6 5,0 7,2 10,0 12,6 14,2 16,0 N/A 630 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 N/A 630 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 N/A 630 and 800 3,6 6,4 9,0 12,6 16,0 18,0 20,0 N/A 800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N/A 800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N/A 800 and 1000 4,8 8,0 11,2 16,0 20,0 22,0 25,0 N/A 1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 N/A 1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 N/A 1000 and 1250 6,4 10,0 14,2 20,0 25,0 28,0 32,0 N/A

Page 9 of 11 Report No.:< 16072518 002 > 29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P Working voltage (V) Creepage distance Pollution degree 1 2 3 Type of insulation I II IIIa/IIIb I II IIIa/IIIb* B** S** R** Verdict 1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N/A 1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N/A 1250 and 1600 8,4 12,6 18,0 25,0 32,0 36,0 40,0 N/A 1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N/A 1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N/A 1600 and 2000 11,2 16,0 22,0 32,0 40,0 44,0 50,0 N/A 2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0 N/A 2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0 N/A 2000 and 2500 15,0 20,0 28,0 40,0 50,0 56,0 64,0 N/A 2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 N/A 2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 N/A >2500 and 3200 20,0 25,0 36,0 50,0 64,0 72,0 80,0 N/A 3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 N/A 3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 N/A 3200 and 4000 25,0 32,0 44,0 64,0 80,0 90,0 100,0 N/A 4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 N/A 4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 N/A 4000 and 5000 32,0 40,0 56,0 80,0 100,0 112,0 126,0 N/A 5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 N/A 5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 N/A 5000 and 6300 40,0 50,0 72,0 100,0 126,0 142,0 160,0 N/A 6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 N/A 6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 N/A 6300 and 8000 50,0 64,0 90,0 126,0 160,0 180,0 200,0 N/A

Page 10 of 11 Report No.:< 16072518 002 > 29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P Working voltage (V) Creepage distance Pollution degree 1 2 3 Type of insulation I II IIIa/IIIb I II IIIa/IIIb* B** S** R** Verdict 8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 N/A 8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 N/A 8000 and 10000 64,0 80,0 112,0 160,0 200,0 220,0 250,0 N/A 10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 N/A 10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 N/A 10000 and 12500 80,0 100,0 142,0 200,0 250,0 280,0 320,0 N/A Supplementary information: * ) IIIb is allowed if the working voltage does not exceed 50 V ** ) B = Basic insulation, S = Supplementary insulation, R = Reinforced insulation See table 29.1 29.2 TABLE: Creepage distances, functional insulation P Working voltage (V) Creepage distance Pollution degree 1 2 3 I II IIIa/IIIb I II IIIa/IIIb* Verdict / Remark 10 0,08 0,4 0,4 0,4 1,0 1,0 1,0 N/A 50 0,16 0,56 0,8 1,1 1,4 1,6 1,8 N/A 125 0,25 0,71 1,0 1,4 1,8 2,0 2,2 N/A 250 0,42 1,0 1,4 2,0 1) 2,5 2,8 3,2 P 400 0,75 1,6 2,2 3,2 4,0 4,5 5,0 N/A 500 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N/A 630 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 N/A 800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N/A

Page 11 of 11 Report No.:< 16072518 002 > 1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 N/A 1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N/A 1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N/A 2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0 N/A 2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 N/A 3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 N/A 4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 N/A 5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 N/A 6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 N/A 8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 N/A 10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 N/A Supplementary information: * ) IIIb is allowed if the working voltage does not exceed 50 V Remark: 1) L/N in front of current fuse:cr=2.6mm. -- End of test report --