Model Description

Similar documents
LEAKHUNTER Plus Model 8066

IRwin Methane Leak Detector. Innovation makes the difference

The New PHD 4 Portable Helium Detector

MATHESON s LaserPro Gases and Gas Delivery Equipment

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Columbus Instruments

Agilent Flowmeter ADM1000

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

780S Ultra High Purity Series

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Discovery HP-TGA 75/750. Site Preparation Guide

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Model Instrument User Manual MINT-0313-XX

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Your local gas generation partner. Precision series Modular gas generation solution for GC.

PRECISION GAS MIXTURES

Constant Pressure Inlet (CCN) Operator Manual

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Mass Flow Controllers

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

This test shall be carried out on all vehicles equipped with open type traction batteries.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Phosgene Sensor. Sensoric COCl2 3E 1

Pneumatic high-pressure controller Model CPC7000

Oxygen & Binary Gas Measurement and Analysis

VIC offers a variety of Calibrated Gas Leaks

RGC-IR Remote Gas Calibrator for IR400

GasLab SAN-102 Micro Oxygen Monitor User Manual

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Gas-Detection Instruments

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

Verification Of Calibration for Direct-Reading Portable Gas Monitors

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

PM105 PRESSURE METER USER S MANUAL

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Portable Gas Analyzers

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

Advanced Test Equipment Rentals ATEC (2832)

h2000 plus HyDROGEN LEAk DETECTOR

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Protec P3000 (XL) Helium Sniffer Leak Detector

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Autocalibration Systems For In Situ Oxygen Analyzers

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

We measure it. For gas and water installers. testo hpa. bar

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Application Note AN-107

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

GasLab SAN-102 Micro Oxygen Monitor User Manual

MODEL CALIBRATION GAS DELIVERY SYSTEM

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Major Design Features

MODEL 9061 ULTRASONIC LEAK DETECTOR INSTALLATION & MAINTENANCE

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Workhorse-15 Oxygen Generator

Working in Gas Hazard Areas

Operating Instructions for

OPERATING INSTRUCTIONS FOR PRO HE HELIUM ANALYZER DANGER

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

All Purpose AP-Series Operation Manual

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

BASCOM-TURNER INSTRUMENTS

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

159 mm 154 mm. Subject to changes 10/2012

Emergency Transport and Ventilation

SAUTER FK Version /2016 GB

Ultra High Purity Model 780S

Ozone. Sensoric O3 3E 1

Gases and welding distributors continue

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

Using the UltraRAE. Firmware 2.35

Canadian Light Source Inc. Vacuum Component Leak Test Technical Procedure

HumiSys HF High Flow RH Generator

Features. Description

THERMAL MASS FLOW MEASUREMENT FOR GASES

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Autocalibration Systems for In Situ Oxygen Analyzers

HI 2314 HI 2315 HI 23151

Additel 761 Automated Pressure Calibrators

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Neil Kane Managing Director EMT UK

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

2018 National Metal and Nonmetal Mine Rescue Contest. Technician Team Competition Written Test (Dräger BG-4) Good Luck!

Transcription:

LEAKHUNTER Plus

LEAKHUNTER Plus Model 8066 Description The MATHESON LEAKHUNTER Plus is a truly universal leak detector. Extensive R&D has produced a multi-functional leak detector engineered to perform superbly in both portable and benchtop applications. It has been designed to locate and measure a wide variety of gas leaks quickly, precisely and cleanly. The LEAKHUNTER Plus is highly sensitive and will locate leaks too small to bubble with a soap solution. And, with the detector cell in the probe itself, the Model 8066 exhibits excellent response and recovery times. Great attention has been paid to ergonomics and durability. And, the Model 8066 s controls have been kept simple so that it can be operated with little or no training.

Applications In the Laboratory: Instruments, such as chromatographs and GC/MS, reaction vessels, sampling cylinders, research apparatus, manifolds, regulators and valves. In the Plant: Pressurized containers and storage vessels, piping, process and gas transfer lines, pilot plant reactions, tracer studies and refrigeration systems. manufacturing, welds, seals and connectors, valves, waterproof enclosures, refrigeration and air conditioning units and military equipment. In the Hospital: Medical gas systems and piping, fittings and apparatus. In the Field: Tracer studies, helium and CO2 pipelines and refrigeration lines. LEAKHUNTER Plus On Production Lines: Quality assurance procedures in Environmental Compliance: Fugitive Emissions CAUTION: The LEAKHUNTER Plus is not designed as intrinsically safe and should not be used to detect leaks of combustible gases which may exceed their lower explosive limit (LEL). The LEAKHUNTER Plus will detect Gases Detected any gas which has a thermal conductivity different from that of the ambient air on which it was zeroed. The larger the difference, the greater the sensitivity. As the instrument will normally be zeroed in ambient air comprised mostly of nitrogen and oxygen, the LEAKHUNTER Plus will not be highly sensitive to leaks of these gases. A gas may have a higher or lower thermal conductivity than air and therefore will produce a positive or negative reading on the display. The LEAKHUNTER Plus groups gases with similar thermal conductivities into one of four Gas Groups. Each of the Groups has a calibration curve stored in memory. While the LEAKHUNTER Plus will detect any gas with a thermal conductivity different from air, the twelve gases below have been tested for sensitivity and assigned to a particular Gas Group. Minimum Detectable Leak Concentration Group Gas Pos/Neg cc/sec cc/min ft 3 /min ppm 1 Hydrogen + 8.10E-06 4.9E-04 1.7E-08 1.3E+02 Helium + 1.00E-05 6.0E-04 2.1E-08 1.6E+02 2 Neon + 5.80E-05 3.5E-03 1.2E-07 9.3E+02 Xenon - 5.81E-05 3.5E-03 1.2E-07 9.3E+02 3 R11-6.84E-05 4.1E-03 1.5E-07 1.0E+03 R12-7.90E-05 4.7E-03 1.7E-07 1.3E+03 R21-7.98E-05 4.8E-03 1.7E-07 1.3E+03 R22-9.46E-05 5.7E-03 2.0E-07 1.5E+03 4 Methane + 1.06E-04 6.4E-03 2.2E-07 1.8E+03 Argon - 1.37E-04 8.2E-03 2.9E-07 2.2E+03 CO2-1.53E-04 9.2E-03 3.2E-07 2.4E+03 Water Vapor - 1.75E-04 1.1E-02 3.7E-07 2.8E+03 Example: 1.00E-05 = 1 x 10-5

Specifications Detection Principle: Dual cell micro volume thermal conductivity Power: 1 x size 9V NiCad battery (alkaline battery, not included, may be substituted) Charger/Adapter: 115V: Combination charger/ac adapter 220V: Charger only Operating Time: NiCad: 4 hours Alkaline: 9 hours Response Time: Approximately 1 second Recovery Time: Approximately 1 second Audio: Fixed volume, variable frequency proportional to leak rate Diagnostics: Low battery indicator Detector cell failure alarm Model Numbers Model Description Temperature: Operating: 0 to 45 C (32 to 113 F) Storage: -10 to 50 C (14 to 122 F) Humidity: 0-90% RH non-condensing Size: Console: 6.75"L x 3"W x 1"D 172mm x 77mm x 26mm Probe: 8"L x 1.75"Diameter 204mm x 28mm Weight: 15.5 ounces (440 gm) (Including case:) 3.3 lb (1.5 kg) Warranty: One year 8066 LEAKHUNTER Plus complete with standard and flex-and-stay extension probes, combination 115VAC adapter/ charger with NiCad battery, durable carrying case 8066-220 Same as above except with 220VAC charger in lieu of charger/ adapter 8066-02 Calibrated leak hardware 8066-03 Replacement standard probe 8066-04 Replacement extension probe 8066-05 Replacement 115VAC charger/adapter 8066-06 Replacement 220VAC charger

T he LEAKHUNTER Plus is so universal that it replaces three previous MATHESON models by combining the best features of the Model 8065 Leak Hunter, the Model 8067 Quantitative Leak Detector and the Model 8017 Benchtop Leak Detector. Moreover, its advanced electronics improves upon these products by providing more sensitive, more stable and more accurate readings. PORTABLE APPLICATIONS The LEAKHUNTER Plus offers the convenience and flexibility of either one or two-handed operation. The following features make it an excellent portable detector. Probe easily attaches to the body of the instrument giving you a free hand. Detachable probe permits access to even the most difficult to reach places. An extension flex-and-stay probe is also included to extend your reach. Precise probe tip can pinpoint leaks in areas where several connections are grouped together. Rechargeable NiCad batteries (included with charger) provide hours of portable operation. QUANTITATIVE APPLICATIONS The LEAKHUNTER Plus can be used to simply locate leaks so they can be corrected, or it can be used to measure the size of a leak. Features which make it an excellent quantitative leak detector include: Calibration data for twelve gases is stored in memory. At the touch of a button, the appropriate calibration data is selected depending upon the target gas to be detected. Leak rates are displayed in a large LCD readout. The user easily switches between units of cc/sec, cc/min, ft 3 /min or ppm. A peak hold function freezes the display at the maximum leak rate encountered as the probe passes through the suspect leak area. Built-in autoranging automatically adjusts the instrument s sensitivity to the size of the leak. BENCHTOP APPLICATIONS By removing the detachable probe, the LEAKHUNTER Plus can be used as a benchtop detector. The following features make it an excellent benchtop detector. Console can sit on benchtop to perform leak detection procedures with just the probe in hand. Console s no-slip feet and built-in incline stand make for a stable setup with easy viewing. AC power adapter provides continuous operation with no need to recharge batteries.

National reach. Local values. www.mathesongas.com 800-416-2505 Copyright 2012 Matheson Tri-Gas, Inc. All Rights Reserved. All contents of this document are subject to change without notice and do not represent a commitment on the part of Matheson Tri-Gas, Inc. Every effort is made to ensure the accuracy of this information. However, due to differences in actual and ongoing operational processes and product improvements and revisions, Matheson Tri-Gas, Inc. cannot guarantee the accuracy of this material, nor can it accept responsibility for errors or omissions. This document is intended to serve as a general orientation and cannot be relied upon for a specific operation. No warranties of any nature are extended by the information contained in these copyrighted materials. All names, products, and services mentioned herein are the trademarks or registered trademarks of their respective organizations and are the sole property of their respective owners. Matheson and the Matheson logo are registered trademarks of Matheson Tri-Gas, Inc. BR41-R06/12 Printed in USA