CAPIOX FX Advance. Oxygenator with Integrated Arterial Filter and Hardshell Reservoir

Similar documents
CAPIOX SX Family of Oxygenators

CAPIOX SX Family of Oxygenators

CAPIOX SX Family of Oxygenators

Prescriptive Oxygenation

Patients come in a range of sizes. Now your oxygenator does, too.

CDI System 500. Blood Parameter Monitoring System. Continuous blood parameter monitoring for improved blood gas management

A complete family of Pediatric Perfusion Systems

Blood Parameter Monitoring System 550

OxygenatOrs QUaDrOx-i adult QUaDrOx-i small adult

QUADROX-i Neonatal & Pediatric Maximum safety for the smallest patients.

INSPIRE Oxygenator Family

INSPIRE Min.I. Redefining minimally invasive approach to perfusion. Expand your choices with INSPIRE Min.I.

INSPIRE TM Inspired choice

INSPIRE TM C The integrated closed system oxygenator for gentle perfusion

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists

Optimized Perfusion Management and Patient Outcome

Considerations in Circuit Miniaturization

INSPIRE TM8 PH.I.S.I.O.

Min.I. Mini Maxi Me. The proven safe and reliable, world-leading perfusion system, now optimized for minimally invasive and pediatric surgery

CDI Blood Parameter Monitoring System 500 A New Tool for the Clinical Perfusionist

Adult All Integrated Mini Bypass System

INSPIRE 6 PH.I.S.I.O.

Emboli Production in Hardshell Venous Reservoirs at Low Reservoir Levels Devin Eilers, BS, Willie Glaze, BS, & David Holt, MA, CCT Clinical Perfusion

S5 TM. Min.I. Mini Maxi Me. The proven safe and reliable, world-leading perfusion system, now optimized for minimally invasive and pediatric surgery

Clinical Engineering. Equipment (Heart-lung machines)

ENT 318/3 Artificial Organ. Artificial Lung. Lecturer Ahmad Nasrul bin Norali

What is optimal flow?

Point-of-Care Testing: A Cardiovascular Perfusionist s Perspective

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

Citation for published version (APA): Somer, F. M. J. J. D. (2003). Strategies for optimisation of paediatric cardiopulmonary bypass s.n.

(12) United States Patent (10) Patent No.: US 6,524,267 B1

Clinical Gaseous Microemboli Assessment of an Oxygenator with Integral Arterial Filter in the Pediatric Population

An In Vitro Study of the Effectiveness of Carbon Dioxide Flushing of Arterial Line Filters

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

PERFUSION SYSTEMS MECC SMART SMART SUCTION SYSTEM

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

Oxygenator Safety Evaluation: A Focus on Connection Grip Strength and Arterial Temperature Measurement Accuracy

INTERNATIONAL MARKETING. 61, avenue Tony Garnier Lyon France Tel.: 33 (0) Fax: 33 (0)

Effects of Purge-Flow Rate on Microbubble Capture in Radial Arterial-Line Filters

Errors in Flow and Pressure Related to the Arterial Filter Purge Line

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Perfusion Safety Review in Japan

Contacts. Quick Start Guide

Equipment and monitoring for cardiopulmonary bypass

ila ACTIVVE SYSTEM PLATFORM

InFlow Modular perfusion bioreactor

Evaluation of Blood Cardioplegia Administration Systems

Kieron C. Potger, CCP, BSc, Dip Perf, MClinN; Darryl McMillan, CCP, Dip Perf; Mark Ambrose, CCP, BNurs, Dip Perf

PRODUCT CATALOGUE OF

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

DONOR TM Pre-Evacuated Post-Operative Autologous Blood Reinfusion System

Effect of Normobaric versus Hypobaric Oxygenation on Gaseous Microemboli Removal in a Diffusion Membrane Oxygenator: An In Vitro Comparison

An In-Vitro Study Comparing the GME Handling of Two Contemporary Oxygenators

Limitations Using the Vacuum-Assist Venous Drainage Technique During Cardiopulmonary Bypass Procedures

O 2 Star - Oxygen Therapy Accessories Consumables and Accessories

The next generation of Blood and Fluid Warming

MEDAP-MOBILE GAS SUPPLY

Airox Supportair Ventilator

User Manual. Model 3930 Vacuum Assisted Venous Drainage Controller w/ WAGD Suction Flowmeter

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER

Dräger coaxial breathing circuits Consumables and Accessories

CMZ Series. Combination. FRZ Series. A combination to reliably remove water is now available!! ib-cyclone FRZ Series BK-P027- Filter regulator

Dräger Pendula Medical Supply Units

Your Life. Your Adventure. Triton Family of Products

INTERVENTIONAL CARDIOLOGY

OxyLine The customised pressure reducer

The next generation of Blood and Fluid Warming

VentStar Oxylog Breathing Systems Consumables and Accessories

Dräger RZ 7000 Test Equipment

Dräger Quaestor 7000 Test Equipment

Development of a Practical Membrane Lung System

VACUUM REGULATORS CONTENTS

Series IRV1000/2000/3000

healthy volunteers were included in the study.

Used with Dissolution Tester for Fraction and Flow Measurements

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule

Bloodlines, Tubing Systems, Accessories

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

URGENT FIELD SAFETY NOTICE

Kieron C. Potger, CCP, BSc, Dip Perf, MClinN ; Darryl McMillan, CCP, Dip Perf ; Mark Ambrose, CCP, BNurs, Dip Perf

User Manual. Model 3930 Vacuum Assisted Venous Drainage Controller w/ WAGD Suction Flowmeter

Dräger ERS-Chamber Refuge Chambers

Standard Flexel 3D bioprocessing bags for Palletank

Boehringer Model Vacuum Assisted Venous Drainage. Frequently Asked Questions

D Reliability goes XL

6. Transport gases in blood

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

DIAGNOSTIC CARDIOLOGY

Dräger Secor 7000 Diving Equipment and Systems

SEPAREL. Hollow Fiber Membrane Module INSTRUCTION MANUAL (For IJ) EF External Flow Small Size Series. EF-MICRO EF-G2 Series EF-G3 Series EF-G5 Series

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435

Dräger X-plore 9000 and PAS X-plore Airline breathing equipment

MyoSure Setup Simplified

Making Life Easier Easypump II

Dräger TSW Elephant Diving Equipment

Industrial Filter. FGD series

Innovative cap to reduce the noise raised by bubbling activity drainage working (vent close)

D Beyond essentials DRÄGER SAVINA 300 SELECT

Transcription:

CAPIOX FX Advance Oxygenator with Integrated Arterial Filter and Hardshell Reservoir Enhanced flow dynamics. Expanded patient range. Advanced outcomes.

Advance to the next level. Terumo has led the way in oxygenator innovation and quality for more than 3 years and was the first and is the only company to manufacture its own hollow fiber. The new CAPIOX FX Advance Oxygenator advances your oxygenator to the next level by enhancing flow dynamics, 1 resulting in lower minimum operating levels and increased maximum blood flow rates. Now, you can expand your options and choose a smaller, lower prime oxygenator for even more patients. Working together with your surgery team, Terumo Cardiovascular Group helps save lives every day. That s why we never compromise quality. And it s why we constantly strive to deliver new technologies that advance patient outcomes and deliver exceptional clinical value. Choose the oxygenator that expands your options and advances patient outcomes. Choose the CAPIOX FX Advance Oxygenator.

terumo-cvgroup.com 2

Introducing the CAPIOX FX Advance Oxygenator with improved flow dynamics. Patients come in all shapes and sizes so do CAPIOX FX Oxygenators. Now, you can expand the use of CAPIOX FX Oxygenators through the enhanced flow dynamics offered on the CAPIOX Advance Hardshell Reservoir. Advancements include an increased blood flow rate on the 3, ml reservoir available on the CAPIOX FX15 Advance Oxygenator and a lower minimum operating level on the 4, ml reservoir available on the CAPIOX FX15 and FX25 Advance Oxygenators. 3, ml Hardshell Reservoir Advantage: Increased maximum blood flow to 5 L/min on the CAPIOX FX15 Advance Oxygenator* Benefit: Flexibility to use on a wider range of patients and the lowest prime adult oxygenator available today 4, ml Hardshell Reservoir Advantage: Reduced minimum operating level of 15 ml on the CAPIOX FX15 and FX25 Advance Oxygenators Benefit: Further helps minimize hemodilution with the lowest-prime full-size oxygenator2 *Use of Vacuum Assisted Venous Drainage may be required to achieve flow rate of 5 L/min. 3

CAPIOX FX15 Advance Oxygenator 4

Advancing Outcomes Built around Terumo CV Group s integrated arterial filter with self-venting technology, the CAPIOX FX Advance Oxygenator helps clinicians reduce prime volume and lower hemodilution. 2 The unique design of the CAPIOX FX Advance Oxygenator contributes to fewer blood transfusions 4 and reduced hospital costs. 2 Low prime volume oxygenators reduce hemodilution, blood transfusions and the risk of Acute Kidney Injury It is well known, with a high level of evidence (Class 1 level a), that excessive hemodilution during cardiopulmonary bypass (CPB) can lead to an increased incidence of red blood cell transfusions and other patient risks, including post-operative Acute Kidney Injury (AKI). A recent study demonstrates that reducing hemodilution with a low prime volume oxygenator, by as little as 15 ml, is associated with fewer blood transfusions and reduced risk of postoperative AKI. 3 CAPIOX FX Advance Oxygenators allow you to minimize hemodilution, resulting in fewer blood transfusions and may decrease the risk of AKI. Enhanced flow dynamics. Expanded patient range. Advanced outcomes. Curved venous inlet enhances flow dynamics 3/8" - 1/4" adapters for the CAPIOX FX15 Oxygenator with 3, ml reservoir 5

Hardshell Reservoir Enhanced flow dynamics Improved flow dynamics reduces blood turbulance and enhances gaseous microemboli removal Rotating, curved venous inlet enhances ease-of-use Increased maximum blood flow to 5 L/min on the CAPIOX FX15 Advance Oxygenator, with 3, ml reservoir, for use on a wider range of patients* Decreased minimum operating level of 15 ml on the CAPIOX FX15 and FX25 Advance Oxygenators, with the 4, ml reservoir, reduces hemodilution Elongated shape provides stable, smooth blood flow path Volume indicators on three sides enhances visibility at all levels and angles Built-in positive pressure relief valve increases convenience and safety CAPIOX FX Oxygenator Proven performance and fully integrated arterial filter Features self-venting technology Low priming volume, high gas exchange and low pressure drop are optimally balanced for superb performance Terumo s exclusive hollow fiber technology enables total process control from raw materials to finished product Woven fiber bundle design provides consistent and high-performance gas exchange Less foreign surface area contact minimizes systemic inflammatory response Multiple blood outlet port configurations allow easy access and circuit flexibility *Use of Vacuum Assisted Venous Drainage may be required to achieve flow rate of 5 L/min. 6

CAPIOX FX15 Advance Oxygenator The CAPIOX FX15 Advance Oxygenator significantly lowers prime volume for patients at risk for a higher rate of blood transfusions. With the CAPIOX FX15 Advance Oxygenator, smaller patients can have surgery with an oxygenator that best fits their unique metabolic needs. And now, the increased blood flow rate available with the 3, ml hardshell reservoir expands the use of a smaller oxygenator to more patients. Maximum blood flow: 5. L/min Oxygenator priming volume: 144 ml Reservoir storage capacity: 3, ml: 7 ml minimum operating level 4, ml: 15 ml minimum operating level FX15 Advance 3, ml FX15 Advance 4, ml 7

CAPIOX FX25 Advance Oxygenator The unique design of the CAPIOX FX25 Advance Oxygenator provides a full-size oxygenator with a low prime volume, and the hardshell reservoir offers a reduced minimum operating level. Maximum blood flow: 7. L/min Oxygenator priming volume: 26 ml Reservoir storage capacity: 4, ml Minimum operating level: 15 ml CAPIOX FX5 Oxygenator The CAPIOX FX5 Oxygenator offers exceptionally low prime volume and high performance. 5 Your most delicate patients deserve the lowest prime volume possible. Maximum blood flow: 1.5 L/min Oxygenator priming volume: 43 ml Reservoir storage capacity: 1, ml Minimum operating level: 15 ml FX5 1, ml FX25 Advance 4, ml 8

CAPIOX FX15 Advance Oxygenator Performance Data 1 O 2 Transfer Rate (ml/min) CAPIOX FX25 Advance Oxygenator Performance Data 1 O 2 Transfer Rate (ml/min) CAPIOX FX5 Oxygenator Performance Data 1 O 2 Transfer Rate (ml/min) O 2 Transfer Rate (in vitro) 4 3 2 1. 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 O 2 Transfer Rate (in vitro) 16 14 AAMI standard 12 1 8 6 4 2 ph = 7.4 O 2 Transfer Rate (in vitro) 6 5 4 3 2 1 ph = 7.4 ph = 7.4 SvO 2 = 65 ± 5% PvCO 2 = 45 ± 5 mm Hg B.E. = ± 5 meq/l V/Q = 1. SvO 2 = 65 ± 5% PvCO 2 = 45 ± 5 mm Hg B.E. = ± 5 meq/l V/Q = 1. SvO 2 = 65 ± 5% PvCO 2 = 45 ± 5 mm Hg B.E. = ± 5 meq/l V/Q = 1. CO 2 Transfer Rate (ml/min) CO 2 Transfer Rate (ml/min) CO 2 Transfer Rate (in vitro) 4 3 2 1 CO 2 Transfer Rate (in vitro) 16 14 V/Q = 2. V/Q = 1. 12 AAMI standard 1 V/Q =.5 8 6 4 2 V/Q = 2. V/Q = 1. V/Q =.5 ph = 7.4 ph = 7.4 ph = 7.4 SvO 2 = 65 ± 5% PvCO 2 = 45 ± 5 mm Hg B.E. = ± 5 meq/l SvO 2 = 65 ± 5% PvCO 2 = 45 ± 5 mm Hg B.E. = ± 5 meq/l SvO 2 = 65 ± 5% PvCO 2 = 45 ± 5 mm Hg B.E. = ± 5 meq/l Tbo-Tbi Twi-Tbi Performance Factor Tbo-Tbi Twi-Tbi Performance Factor Tbo-Tbi Twi-Tbi Performance Factor Heat Exchanger Performance Factor (in vitro) 1..9.8.7.6.5.4.3.2.1 Tbi = 3 ± 1ºC Twi = 4 ± 1ºC Water Flow Rate = 15 L/min. 2 4 6 8 2 4 6 8 2 4 6 8 Heat Exchanger Performance Factor (in vitro) 1..9.8.7.6.5.4.3.2.1 Blood Side Pressure Drop (in vitro) 12..5 1. 1.5 2. 2.5.5 1. 1.5 2. 2.5.5 1. 1.5.5 1. 1.5 Holder Systems CO 2 Transfer Rate (ml/min) CO 2 Transfer Rate (in vitro) 6 5 4 3 2 1 V/Q = 2. V/Q = 1. V/Q =.5 Heat Exchanger Performance Factor (in vitro) 1..9.8.7.6.5.4.3.2.1 Tbi = 3 ± 1ºC Twi = 4 ± 1ºC Water Flow Rate = 15 L/min Tbi = 3 ± 1ºC Twi = 4 ± 1ºC Water Flow Rate = 15 L/min Pressure Drop (mm Hg) Pressure Drop (mm Hg) Pressure Drop (mm Hg) Blood Side Pressure Drop (in vitro) 15 1 5 1 5 1 8 6 4 2 1 2 3 4 5 B.E. = ± 5 meq/l Blood Side Pressure Drop (in vitro) 15 15 1 2 4 6 8 B.E. = ± 5 meq/l 5 15 1 5 12 8 4 (kpa) (kpa) (kpa) XX*CXH18R/8184 XX*XH32/81139 XX*CXH15 XX*CXH18 XX*CXH5R 9

Specifications Oxygenator and Heat Exchanger Housing Polycarbonate Material Oxygenator fibers Microporous polypropylene Heat Exchanger Stainless steel Oxygenator FX15 FX25 FX5 Fiber bundle surface area Approx. 1.5 m 2 Approx. 2.5 m 2 Approx..5 m 2 Heat exchanger surface area Approx..14 m 2 Approx..2 m 2 Approx..35 m 2 Blood flow range.5-5. L/min.5-7. L/min.1-1.5 L/min Priming volume (static) 144 ml 26 ml 43 ml Blood inlet port (from pump) 3/8" (9.5 mm) 1/4" (6.4 mm) Blood outlet port 3/8" (9.5 mm) 1/4" (6.4 mm) Cardioplegia port 1/4" (6.4 mm) N/A Luer port (for recirc. or blood cardioplegia) N/A One luer lock on blood outlet port Gas inlet port 1/4" (6.4 mm) Gas outlet port 1/4" (6.4 mm) 5/16" (7.9 mm) Water ports 1/2" (12.7 mm) Hansen quick connect fitting Maximum pressure blood inlet 1. mm Hg (133 kpa) (1.36 kgf/cm 2 ) Maximum pressure water inlet 1,47 mm Hg (196 kpa) (2 kgf/cm 2 ) Arterial Filter Filter material Polyester screen type Pore size 32 µm Surface area 36 cm 2 6 cm 2 13 cm 2 CAPIOX Advance Hardshell Reservoir Material Housing Polycarbonate Venous filter Polyester screen type, pore size 47 µm Cardiotomy filter Defoamer Polyester depth type Polyurethane foam Hardshell Reservoir FX15 FX25 FX5 Blood flow range Venous flow Cardiotomy inlet Combined flow R3C.5-5. L/min Max. 4. L/min Max. 5. L/min R4C.5-5. L/min Max. 5. L/min Max. 5. L/min.5-7. L/min Max. 5. L/min Max. 7. L/min.1-1.5 L/min Max. 1.5 L/min Max. 1.5 L/min Blood storage capacity 3, ml 4, ml 4, ml 1. ml Minimum operating volume 7 ml 15 ml 15 ml 15 ml Venous blood inlet port 3/8" (9.5 mm) Rotatable 1/2" (12.7 mm) Rotatable 1/2" (12.7 mm) Rotatable 1/4" (6.4 mm) Rotatable Blood outlet port (to pump) 3/8" (9.5 mm) 1/4" (6.4 mm) Suction ports Six, 1/4" (6.4 mm) Vertical port to CR filter 3/8" (9.5 mm) N/A Quick prime port Vent port Auxiliary port Luer ports Maximum sustainable negative pressure in reservoir 1/4" (6.4 mm) 1/4" (6.4 mm) 1/4" - 3/8" (6.4 mm - 9.5 mm) Five, 3/16" - 1/4" (4.8 mm - 6.4 mm) Rotatable Three filtered luer locks to cardiotomy filter. One non-filtered luer lock. Two luer locks on venous inlet. -15 mm Hg (-2 kpa) Positive pressure relief valve - 8 mm Hg (1.1 kpa) N/A Xcoating Surface Coating. Terumo s biocompatible amphiphilic polymer surface coating is a standard feature on all CAPIOX FX Advance Oxygenators. 1

Ordering Information West Outlet Port Oxy inlet on right when outlet is facing away from user. East Outlet Port Oxy inlet on left when outlet is facing away from user. Catalog # Description Units/Case CAPIOX FX15 Advance Oxygenator 1CX*FX15W + With integrated arterial filter, west orientation 4 1CX*FX15E + With integrated arterial filter, east orientation 4 3CX*FX15RW3C # With integrated arterial filter, 3, ml hardshell reservoir, west orientation 4 3CX*FX15RE3C # With integrated arterial filter, 3, ml hardshell reservoir, east orientation 4 3CX*FX15RW4C With integrated arterial filter, 4, ml hardshell reservoir, west orientation 4 3CX*FX15RE4C With integrated arterial filter, 4, ml hardshell reservoir, east orientation 4 CAPIOX FX25 Advance Oxygenator 1CX*FX25W With integrated arterial filter, west orientation 4 1CX*FX25E With integrated arterial filter, east orientation 4 3CX*FX25RWC With integrated arterial filter, 4, ml hardshell reservoir, west orientation 4 3CX*FX25REC With integrated arterial filter, 4, ml hardshell reservoir, east orientation 4 CAPIOX FX5 Oxygenator 1CX*FX5RW^ With integrated arterial filter, 1, ml hardshell reservoir, west orientation 4 1CX*FX5RE^ With integrated arterial filter, 1, ml hardshell reservoir, east orientation 4 Holders for CAPIOX FX Oxygenators 81139 FX15/25 Advance oxygenators with hardshell reservoir, short arm 1 8184 FX15/25 Advance oxygenators with hardshell reservoir, long arm 1 1XX*CXH15 FX15/25 Advance oxygenators 1 1XX*CXH18 FX15/25 Advance oxygenators when separated from reservoir 1 XX*CXH18R FX15/25 Advance oxygenators with hardshell reservoir 1 XX*XH32 FX15/25 Advance oxygenators with hardshell reservoir, short arm 1 XX*CXH5 FX5 oxygenator 1 XX*CXH5R FX5 oxygenator with hardshell reservoir 1 XX*CXH5AD Adapter for SX holder for FX5 1 Accessories for CAPIOX FX Oxygenators 1CX*BP21 Blue thermistor wire 1 1CX*BP22 Red thermistor wire 1 + Contains two 1/4" - 3/8" adapters # Contains four 1/4" - 3/8" adapters ^ Contains four 3/16" - 1/4" adapters, one 1/4" - 3/8" adapters, and a recirculation line REFERENCES: 1. Internal testing, data on file. 2. Bronson, S., et al. Prescriptive Patient Extracorporeal Circuit and Oxygenator Sizing Reduces Hemodilution and Allogeneic Blood Product Transfusion during Adult Cardiac Surgery. JECT. 213; 45:167-172. 3. Ranucci, M., et al. Effects of priming volume reduction on allogeneic red blood cell transfusions and renal outcome after heart surgery. Perfusion. March 215; 3(2). 4. Lahanas, A., et al. A retrospective comparison of blood transfusion requirements during cardiopulmonary bypass with two different small adult oxygenators. Perfusion. July 213; 28(4). 5. Deptula, J., et al. Clinical Evaluation of the Terumo CAPIOX FX5 Hollow Fiber Oxygenator with Integrated Arterial Line Filter. JECT. 29; 41:22-225. For information on Terumo Cardiovascular Group products: Terumo Cardiovascular Group 62 Jackson Road Ann Arbor, MI 4813-93 USA Tel: +1.734.663.4145 Fax: +1.734.663.7981 www.terumo-cvgroup.com Terumo Corporation 44-1, 2-chome, Hatagaya Shibuya-Ku, Tokyo 151-72 Japan Tel: +81.3.3374.8111 Fax: +81.3.3374.8399 www.terumo.co.jp Terumo Europe N.V. Authorized EC Representative Interleuvenlaan 4, 31 Leuven Belgium Tel: +32.16.38.12.11 Fax: +32.16.4.2.49 www.terumo-europe.com Terumo Europe N.V. Cardiovascular Division Ludwig-Erhard-Strasse 6 6576 Eschborn Germany Tel: +49.6196.823. Fax: +49.6196.823.555 Terumo Latin America Corporation 875 NW 36th Street, Suite 6 Miami, FL 33178 USA Tel: +1.35.477.4822 Fax: +1.35.477.4872 Terumo Corporation Dubai Branch Al Masraf Tower, 22nd Floor P.O. Box 2291, Dubai UAE Tel: +971.4.221222 Fax: +971.4.221333 Terumo India Pvt. Ltd. Unit No. 161 & 162 Tower B 16th Floor, Unitech Cyber Park Sector-39 Gurgaon, Haryana 1221 India Tel: +91.124.47187 Fax: +91.124.4718718 Terumo Asia Holdings Pte. Ltd. 3 Beach Road #33-3 The Concourse 199555 Singapore Tel: +65.6.295.1792 Fax: +65.6.294.2329 Terumo and CAPIOX are registered trademarks and Xcoating is a trademark of Terumo Corporation. 215 Terumo Cardiovascular Systems Corporation. December 215. 863551