Bottled Gas. Using LPG safely. for the way you want to live

Similar documents
Using propane cylinders safely

User Information Sheet 028

CODE OF GUIDANCE. For the Storage of Full & Empty LPG Cylinders and Cartridges. Page 1

LPG TANK INFORMATION An energy company that puts

Working Environment Safety Assessment

Welcome to your new Firepod It will only work properly on Propane Gas (Also known as LPG and Patio Gas) with the special regulator supplied

USE AND ASSEMBLY INSTRUCTIONS

LPG SAFETY INFORMATION. Kwik-Gas. Safety Manual. Less talk more energy

Portable Gas Barbeque and L P Gas Cylinder

Summary of the MRA LPG Codes of Practice

Technical Publication. Cylinder Cage - Instructions for Use

Drum / cylinder handling

Liquefied Petroleum Gas Market Regulations S.L

Cylinder Exchange Training Manual

Safety Data Sheet. Chlorine trifluoride. Version : 1.05

A little technical and safety...

Installation and Operation Instructions

WARNING: FOR OUTDOOR USE ONLY

STORAGE OF COMPRESSED GAS CYLINDERS (SAF-SPI-15)

User Information Sheet 015

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Important: Retain these instructions for future use.

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

CRAFTSMAN EXAMINATION, NOVEMBER 2007 GASFITTING ANSWER SCHEDULE

USER S INFORMATION MANUAL

ASSEMBLY INSTRUCTIONS HOODED GAS GRILL. Model:KYQ-BFT402

PRODUCT SAFETY DATA SHEET BUTANE AND MIXTURES. Specific risk: EXTREMELY FLAMMABLE

WLPGA East African Summit

Safety data sheet Code MAP-Pro Page 1 of 5 Issue Date Feb 26, SECTION 1: Identification of substance/preparation and company

MATERIAL SAFETY DATA SHEET. Oxygen, Refrigerated Liquid DOT Hazard Class: 2.2

APPROVED FOR USE IN SOUTH AFRICA STAINLESS STEEL STOVE

GAS BBQ 4 burner. instructions for. model no: BBQ10

PRODUCT SAFETY DATA SHEET BUTANE AND MIXTURES. Specific risk: EXTREMELY FLAMMABLE

DSEAR- Storage, Use and handling of gas cylinders guidance.

5.0 Store. safely IN THIS SECTION: 5.1 Decanting or transferring

LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH

Label 2.2: Non-flammable, Non-toxic gas 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

PRODUCT SAFETY DATA SHEET BUTANE AND MIXTURES. Specific risk: EXTREMELY FLAMMABLE

13kW Patio Heater. Assembly & User Instructions

Welcome to Calor Information on your business gas supply

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

Owner s Manual for Assembly, Operating & Maintenance of

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Emergency Procedures for Forecourt Sites Storing and Dispensing LPG

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

Examples of pressure systems and equipment are:

Safety Data Sheet. Ammonia. Version : 1.03

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

User Information Sheet 013

KENYA STANDARD KS 2386: PART 8: 2018 Emergency procedure guide- Transport (Road, Rail) Part 8: Gases

Training Program 1A Filling 1 lb. Refillable Propane Cylinders

MSDS (MATERIAL SAFETY DATA SHEET) north sea BUTANE. MSDS Nr: BOC(A) Page: 1/5

Black Dragon Forge MKI Post Box Forge MKII Damascus Forge

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

PRODUCT SAFETY DATA SHEET BUTANE AND MIXTURES. Specific risk: EXTREMELY FLAMMABLE

LIQUEFIED PETROLEUM GAS (LPG) AND NATURAL GAS (NG) - FIRE PREVENTION ISSUES

Propane Conversion Kit Instruction

There are three fuelling systems which use LNG/CNG and which may be found in vehicles today:

PRODUCT SAFETY DATA SHEET BUTANE AND MIXTURES. Specific risk: EXTREMELY FLAMMABLE 1. IDENTIFICATION OF THE SUBSTANCE AND OF THE COMPANY/ UNDERTAKING

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

In Vessel Composter Installation & Commissioning Manual

MATERIAL SAFETY DATA SHEET

CALGARY BBQ MODEL#GB7540S

OWNER S MANUAL 28" GRIDDLE COOKING STATION

SAFE HANDLING OF CYLINDERS Information for Customers Handling Gas Cylinders

Compressed Gasses Safety

ENGLISH. KLASEN gas barbecue WARNING

Section 1.3: PRESSURE VESSEL COMPONENTS AND SYSTEMS AND COMPRESSED GAS CYLINDERS

ACS.CoNGLP1 SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC NATURAL GAS TO LPG GENERIC

MATERIAL SAFETY DATA SHEET

CNG/LPG Vehicles Emergency First Response Guide

PROVISIONAL TECHNICAL GUIDELINES FOR LPG OPERATIONS

Safety Data Sheet RS-52 (R428A) Version : 1

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT. Number: 2015 IFC Effective Date: February 1, 2017 Page 1 of 5

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

part seven lpg installations

G AS BBQ GRILLS INSTALLATION INSTRUCTIONS

Propane Conversion Kit Instruction

Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices. Unit Objectives. Pressure Vessels and Piping (1 of 2)

POTENTIAL HAZARDS OF VARIOUS SUBSTANCES

OPERATING INSTRUCTIONS AND OWNER S MANUAL READ AND FOLLOW ALL INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS

TURBO SET 1000 E D $'9 5(9

Handling and Storage of Gases

SPECIFICATION SHEET. OMEGAFLEX, Ltd. TracPipe Flexible Gas Piping Specification Sheet Specification date. ProjectName

Safety Data Sheet. Nitrous oxide. Version : see paragraph 16 "OTHER INFORMATION" see paragraph 16 "OTHER INFORMATION"

CERTIFYING GASFITTER

Annual Report on Liquefied Petroleum Gas (LPG) Related Accidents

Contractors' Code of Safe Practice

VERTICAL AIR COMPRESSORS

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

DATA SHEET Revised edition no : 0 MÁM M«MÅ. : Industrial and professional. Perform risk assessment prior to use. Company identification

SAFETY SHEET. (D.M. nr /01/92 - S.O.G.U. nr /02/92) Product: GAS CONTROL Sheet 4050 v. 0 Page

CERTIFYING GASFITTER

Material Handling and Storage of compressed gases and Air equipment

Not an expected route of exposure.

SAFETY DATA SHEET PRODUCT NAME Sulfur hexafluoride 1.2 RELEVANT IDENTIFIED USES OF THE SUBSTANCE OR MIXTURE AND USES ADVISED AGAINST :

Propane Conversion Kit Instruction

The following instructions were provided by the manufacturer.

Transcription:

Bottled Gas www.jsygas.com Using LPG safely for the way you want to live

Using LPG safely An introduction This guidance is aimed at small-scale users of LPG in cylinders. It does not apply to LPG from bulk tanks. It contains notes on good practice, which you may find helpful in deciding what you need to do. For the purposes of this sheet the term cylinders includes disposable cartridges. Propane - External use only Propane is generally used for fixed installations, Patio Heaters and larger Barbecues. The connection to the cylinder is via a left-hand threaded connection (POL). Regulators are connected and tightened using a correctly sized spanner and tested for leaks using leak detection solution. A propane safety pack is available from Jersey Gas and Kosangas, which include a spanner, leak detection solution and an instruction leaflet. Butane - Indoor use only (heaters & cookers) Butane is primarily used for domestic applications. The connection is on the top of the cylinder and is a clip on type (27mm). Hazards LPG (propane or butane) is a colourless liquid, which readily evaporates into a gas. It has no smell, although it does have an odour added to it. It is heavier than air, so it tends to sink towards the ground. It can flow for long distances along the ground, and can collect in drains, gullies and cellars. LPG is supplied in pressurised cylinders to keep it liquefied. The cylinders are strong and not easily damaged. Leaks can occur from valves and pipe connections, most likely as a gas. LPG liquid can cause cold burns to the skin. Precautions Fixed cylinder installations If you have one or more cylinders fixed in position for connection to an appliance, the installer must ensure that they are located in a safe place and have all the necessary safety devices to protect the hoses, pipework and appliances attached to them. However you need to look after the installation. In particular you should: Ensure the cylinders are kept secured in position and are not tampered with. Don t let anyone work on the installation unless they are suitably trained and competent to do the work. Don t do any modifications, which may affect the safety of the installation, such as altering firewalls, or erecting sheds or fences or installing electrical equipment near the cylinders. If in doubt, ask your LPG supplier for advice. If you suspect that the LPG hoses are deteriorating, contact us on 755550. Cylinders not fixed in position Keep all cylinders in a safe, well-ventilated place, preferably in the open air, and away from occupied buildings, boundaries and sources of ignition and heat. Make sure the cylinders are properly secured and are kept upright. In all cases: Report any equipment failure or damage to us on 755550 without delay, and ask them for advice about what you should do. If you smell gas, call us immediately on 755555

Where to locate your Propane cylinder - Outdoor use only Cylinders must be: Located against a wall or structure of the building with at least 30 minutes fire resistance Positioned on firm level ground in a well ventilated area. Positioned where they remain accessible at all times Where they do not obstruct any means of access to and from the property. Sited where they are reasonably protected from accidental damage or interference by persons, animals or vehicles etc. Cylinders must not be located: In any cellars, basements, sunken areas or indoors. Less than 1 metre measured in the horizontal plane from the nearest cylinder valve from: Fixed sources of ignition, readily ignitable materials, excessive heat sources, oil tanks. Unprotected electrical equipment. Apertures in the property, doors, airbricks, ventilation ducts, flue terminals, open able windows, doors etc. Less than 0.3 metres measured vertically above the cylinder valve(s) from the items listed above. Unless a non-combustible weatherproof hood, which does not impair access to the valves, is provided. Closer than 2 metres measured in the horizontal plane from: Untrapped drains. Unsealed gullies. Openings to cellars. Unless an intervening diversion wall not less than 250mm high is provided. Within 3 metres of any corrosive, toxic or oxidising materials unless a fire resistant barrier is interposed. The area around the cylinders should be kept clear of litter, vegetation or other flammable materials. 2x450mm x 450mm paving slabs, or 1000mm x 450mm x 50mm concrete base 4x450mm x 450mm paving slabs, or 2000mm x 450mm x 50mm concrete base

Where to locate your Butane cylinder Butane cylinders should only be used with: 1. Certified mobile or portable appliances, which incorporate a cylinder compartment and are certified for use inside domestic premises. 2. Fixed appliances in which case: Cylinders are located in a safe place, secure against interference Cylinders shall not be used, or stored, in basements or cellars. Cylinders supplying fixed installations shall be located in a housing with a half hour fire resistance. Not more than 15kg of butane shall be in use per unit dwelling. No sill exists which is higher than the base on which the cylinder rests Cylinders shall be located so as not to impede any means of escape. Where an internal housing is provided for butane cylinders, the housing shall have a fire resistance of not less than 30 min. The housing shall be of adequate size to cover the number of cylinders necessary to serve the installation and allow for easy operation of any valve. It shall also allow access to connections and regulating devices and allow replacement of cylinders with a minimum of disturbance to the installation and ancillary equipment. Adequate vents shall be provided direct to the outside at high and low level, as large as is practicable and each not less than 1/100 of the floor area of the housing. Adequate vents shall be provided direct to the outside at high and low level, as large as is practicable and each not less than 1/100th of the floor area of the housing The housing shall have a fire resistance of not less than 30 minutes Max 15kg No sill exists which is higher than the base on which the cylinder rests

Cylinder connections Your LPG cylinder connections will give years of trouble free service. They do not however, last forever and will require replacing from time to time. If you suspect the connections are showing signs of deterioration, please call Jersey Gas on 755550 and we will arrange to replace them. Connections on most fixed installations will be replaced FREE OF CHARGE. Choosing the correct cylinder and regulator Suitable for 901, 904 and 907 Camping Gaz cylinders Not suitable for use in Jersey Suitable for 13kg and 7kg Butane cylinders

Bottled Gas Collect bottled gas from our agents St Brelade Falles Garage Airport Road St Brelade 7.00am - 9.00pm daily Tel 745665 Jacksons Yacht Services Le Boulevard, St Aubin 8.00am - 5.30pm Mon - Sat 9.00am - 5.30pm Wed Tel 743819, PROPANE & CAMPING GAZ St Clement Roberts Garage Greve D Azette 6.30am - 10.30pm daily Tel 789772 & PROPANE St Helier Kufra Marina Shop New North Quay 5.30am - 5.00pm Mon - Sat 8.00am - 1.00pm Sun Tel 736955, PROPANE & CAMPING GAZ Roberts Garage Springfield Road 6.00am - 1.00am daily Tel 752222, PROPANE & DEPOSITS St Lawrence Bel Royal Motors Bel Royal 8.30am - 5.00pm Mon - Fri 9.00am - 1.00pm Sat Tel 722556 & CAMPING GAZ Roberts Garage Bel Royal 6.00am - 1.00am daily Tel 720644, PROPANE & CAMPING GAZ St Mary Co-op En-Route Rue Des Buttes, St Mary 7.00am - 10.00pm daily Tel 484572 & PROPANE St Ouen St Ouens Motorworks La Grande Route de St Ouen 7.00am - 8.00pm Mon - Fri 9.00am - 6.00pm Sat Tel 481870, PROPANE & CAMPING GAZ St Peter St Peters Garden Centre L Avenue de la Reine Elizabeth II 5.30am - 6.00pm Mon-Sat 8.30am - 7.00pm Thu St Peter Tel 745903, PROPANE & DEPOSITS Co-op, En-Route Beaumont, St Peter 7.00am - 10.00pm daily Tel 484572 St Saviour Falles Service Station Longueville Road 7.00am - 9.00pm daily Tel 888441 Checkers Express La Grande Route de St Martin, Five Oaks 6.30am - 10.30pm Mon - Sat 7.30am - 10.30pm Sun Tel 811049, PROPANE & DEPOSITS JFTU La Rue du Trot 8.00am - 4.30pm Mon - Fri 9.00am - 12.30pm Sat Tel 865304, PROPANE & CAMPING GAZ Trinity JFTU Sion 8.00am - 5.30pm Mon - Fri 9.00am - 5.00pm Sat Tel 733277, PROPANE, CAMPING GAZ & DEPOSITS Spar Hautes Croix 7.00am - 10.00pm daily Tel 765685 for the way you want to live 02/18