Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Similar documents
Driver Operator Pumps: Basic Pump Operations

Fire Apparatus Operator: Pumper

Fire Apparatus Operator: Pumper

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Fire Service Training The University of Kansas. Fire Apparatus Driver/Operator Study Guide June National Certification Program

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition)

Apparatus Operator Refresher Training Program

Fire Apparatus Operator: ARFF

Fire Apparatus Operator Aircraft Rescue and Fire Fighting

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

Emergency Vehicle Driver

Apparatus Operator/Pumper

Driver Releasal Manual

Florissant Valley Fire Protection District Monthly Training Schedule

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019

State of Oregon Department of Public Safety Standards and Training. Driver Task Book. Task Book Assigned To:

Colorado Division of Fire Prevention & Control Driver Operator JPRs (NFPA 1002, 2014 Edition)

Topic: Forward Lay/Offensive Fire Attack Reference #: DG 16-6 orig Level of Instruction: In service personnel Time Required: 3 hours

Firefighter Code of Ethics

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

Chapter 14 Water Shuttle Operations

KILGORE FIRE DEPARTMENT

Rescue Technician: Confined Space Rescue I/II

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

Apparatus Driver/Operator Evaluation Form Rosenbauer Tanker:

The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus.

Wilton Fire Protection District. TRAINING DIVISION New apparatus

Northeastern Illinois Public Safety Training Academy. Course Syllabus 103

APPARATUS DRIVER / OPERATOR PUMPER

Des Plaines Fire Dept. Engineer Program

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

FIRE FIGHTER II JPR: FFII-1A

TECHNICAL RESCUE JPR s ROPE RESCUE TECHNICIAN SKILLS LEVEL I

STUDENT SUPPLEMENT. Approved and Adopted by the Office of State Fire Marshal

Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010

FSRS Relative Point Value Guide

Certification Guide Fire Fighter I

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES

**ALL SHADED SKILLS MUST BE SIGNED OFF BEFORE LIVE FIRE TESTING MAY OCCUR**

Rescue Core Prerequisites NFPA 1006, Chapter 5, 2008 Skills Completion

Topic: Equipment Scramble Reference #: DG14-03 Date: March 10, 2014 Level of Instruction: In service personnel Time Required: 3 Hours

Essentials of Fire Fighting 6 th Edition Firefighter I

Pump Stages. By Tom Murray

ENGINE 260 REVISED

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program

Essentials of Fire Fighting

FIREFIGHTER II. STUDENT Task Book. Agency/Department:

Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet

September 2018 Pressure Test

Rapid Intervention Crews. 11 Skills Total

CITY OF CHICAGO FIRE DEPARTMENT FIRE ENGINEER PROMOTIONAL PROCESS STUDY GUIDE UPDATE FOR THE PROFICIENCY TEST

Varying pump capacity affects the required hoseline diameter

Rescue Technician: Rope Rescue I

2017 Volunteer Week - Course Descriptions

TECHNICAL RESCUE NFPA 1006, Chapter 5, 2013 Edition

DRIVER/OPERATOR - PUMPER NFPA 1002

Industrial Fire Brigade: Interior Structural

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM HYDRA ASSIST VALVE

TRAINING HUMAN RESOURCE DEVELOPMENT

Donning Personal Protective Equipment

SKILL VERIFICATION BOOK FIREFIGHTER I MODULE I FIRE PROTECTION BUREAU. Assigned to: Name:

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION FIREFIGHTER 2 PERFORMANCE EVALUATION

Fauquier County Fire Rescue Association. Driver Release Policy

Technical Rescuer Rope Rescue Level I NFPA 1006

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

Rescue Technician: Rope Rescue II

Piped Air SCBA Refilling System Standard

TurboDraft Fire Eductor

Alabama Smoke Diver Policies

Poudre Fire Authority Driver/Operator Manual Third Edition March 2006

Colorado Division of Fire Prevention and Control Firefighter I JPR's (NFPA 1001, 2013 Edition)

PERFORMANCE CRITERIA AND INSTRUCTIONS

Skill Sheet 17-I-2. Attack a structure fire above, below, and at ground level Interior attack. (NFPA 1001, , )

DIMERSAR TECHNICAL RESCUE. Ice Rescue Technician Level I & II

Reverse Osmosis System Installation Guide and Operation Manual.

September 2017 Safety Meeting Conducting Regulator Performance Tests

Structural Firefighting Review: Fire Attack

PENTICTON FIRE DEPARTMENT AUXILIARY FIRE FIGHTER INFORMATION PACKAGE

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Technical Rescuer Rope Rescue Level II NFPA 1006

TurboDraft. Fire Eductor Operating Instructions.

PUMP OPERATIONS SAN FRANCISCO FIRE DEPARTMENT

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES

Volunteer Firefighter Applicant Information Package

NFPA Standard on. Training for Initial Emergency Scene Operations Edition

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Rescue Technician: Cave Rescue I/II

Fire Service Training & Measuring Competency. Colin Murray Head of Airside Operations, Edinburgh Airport, UK.

Table of Contents. I. General Instructions. II. Task Information. III. Operator Qualification Checklist. IV. Railroad Commission/Employer Record

Water Rescue Course (Surface- and Swift- Levels I&II) Task Book

Fire Fighter I Skill Station Menu NFPA Edition

Method Statement: Testing Dry Riser System

NEVADA STATE RAILROAD MUSEUM

How many intakes can I operate from the control center? Up to 4 intakes can be controlled from the control center.

Transcription:

Driver Operator Pumps: Water Supplies 2 Skills Total NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Driver Operator Pumps: Water Supplies Skills Book JPR NFPA 1002 Task: Driver Operator: Pumps Water Supplies 1 Relay pumping from a Hydrant 5.2.2 2 Relay pumping from a Static Water Source 5.2.2

SKILL SHEET # 1 Relay Pumping from Hydrant Performance Evaluation: The evaluator shall verify the candidate has the ability to pump a supply line of 2½ or larger so that the correct pressure and flow are provided to the next pumper in the relay. JPR: 5.2.2 NFPA 1002, 2014 Edition Instructor s Statement STEPS FOR SKILL COMPLETION 1. Properly positions apparatus and sets apparatus park brake. 2. Correctly shifts pump transmission to pump operation. 3. Places truck transmission in proper gear. 4. Accesses the water supply source. 5. Checks transfer valve for correct position (if applicable). 6. Effectively switches from internal water source to hydrant source. C7. Builds pump pressure to the correct pressure for the relay supply line. C8. Correctly adjusts pressure on the supply line after checking with receiving pumper for a 20 to 50 psi intake pressure on the receiving pumper if necessary. 9. Correctly sets the pressure control device. Tasks: Position a fire department pumper to operate at a fire hydrant, set up for relay operations, appropriately make the transition between internal and external water sources, provide correct pressure and flow to the next pumper in the relay. The candidate, given a relay pumping evolution, the length and size of the line, and the desired flow and intake pressure, shall pump a supply line of 2½ or larger so that the performance steps are completed. Equipment Required: Fire department pumping apparatus, relay pumping evolution parameters, 2½ or larger supply hose for relay operations, fire hydrant Critical Skills are identified by a bold type C. Any candidate that fails to complete a critical skill shall receive an unacceptable completion for the entire Practical Skill Sheet. Safety: A safety violation is grounds for automatic failure. All proctors present shall review the safety violation. 10. Monitors the pump operation for potential problems checks for excess heating of pump and engine, demonstrates use of pump cooling valve and auxiliary cooling valve. Total Initial Retest Yes No Yes No Score needed to pass 6

SKILL SHEET #2 Relay Pumping from Static Water Source Performance Evaluation: The evaluator shall verify the candidate has the ability to pump a supply line of 2½ or larger so the correct pressure and flow are provided to the next pumper in the relay. JPR: 5.2.2 NFPA 1002, 2014 Edition Instructor s Statement Tasks: Operate a fire apparatus in compliance with applicable state & local laws and departmental rules & regulations. Position a fire department pumper to operate from a static water source, set up for relay operations, appropriately make the transition between internal and external water sources, provide correct pressure and flow the next pumper in the relay. Equipment Required: Fire department pumping apparatus, relay pumping evolution parameters, 2½ or larger supply hose for relay, static water source and appropriate equipment for operating from static water source. Critical Skills are identified by a bold type C. Any candidate that fails to complete a critical skill shall receive an unacceptable completion for the entire Practical Skill Sheet. Safety: A safety violation is grounds for automatic failure. All proctors present shall review the safety violation. STEPS FOR SKILL COMPLETION 1. Properly positions apparatus and sets apparatus park brake. 2. Correctly shifts pump transmission to pump operation. 3. Assembles hard suction hose as necessary. 4. Operates primer and primes centrifugal pump. 5. Operates auxiliary cooling system. 6. Assembles hose lines, nozzles, valves, and appliances as necessary. 7. Checks position of transfer valve if applicable (multi-stage pumps). C8. Builds pump pressure to correct pressure for relay supply line. C9. Correctly adjusts pressure on supply line after verifying with receiving pumper for a 20 to 50 psi intake pressure on the receiving pumper if necessary. 10. Correctly sets the pressure control device. 11. Monitors the pump operation for potential problems. Total Initial Retest Yes No Yes No Score needed to pass 8

Relay Pumping/Static Relay Pumping/Hydrant CERTIFICATION SKILLS SIGN-OFF NFPA 1002 Fire Apparatus Operator-Pumps Water Supplies Skill Sheet Number 1 2 3 4 5 6 7 8 9 10 11 12 13 Skill Sheet Title Text Reference: IFSTA Pumping and Aerial Apparatus Driver Operator Handbook, 3 rd edition Candidate s Names 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20.

VERIFICATION Test Location: Test Date: Evaluator Name (Print) Evaluator Signature: Delivery Agency Verification (Printed) (Signature)