Precision Liquid Settlement Array Manual

Similar documents
Vibration isolation system 1VIS10W. User manual

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

VW Liquid Settlement System VWLSS-200

USER S MANUAL. Model TES-SM-30V

RST INSTRUMENTS LTD.

Pressure Dump Valve Service Kit for Series 2300 Units

SSM0019 G. D Aerator SS6000 Liquid Settlement System Flushing Tool User s Manual

DTG - LCD Digital Temperature Gauge USER MANUAL

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

PURA. Pure Gas Dewpoint Transmitter. Users Guide

Vibrating Wire Load Cell (3, 4, 5 And 6 Gauge Cells) User Manual

Pressure Dump Valve Service Kit for Series 3000 Units

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

GILMONT ACCUCAL FLOWMETERS

Instruction Manual. Model Multipoint Settlement System

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

PP-1, PP-1W, PP-2, & PP-3

Wellhead Mast. Installation and Operation Guide. Nanometrics Inc. Kanata, Ontario Canada

NCDOT S EXPERIENCE USING HYDRAULIC SETTLEMENT GAUGES. David L. Teague,P.E. NCDOT GEOTECHNICAL ENGINEERING UNIT

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

MANUAL. Sesame. Thermoplastic Tank Technologies

Installation, Operation, and Maintenance Manual

Fiber Cable Puller with Tuf-Lugger lite

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Backboard and Rim Owners Manual

BUTTERFLY VALVES Series 800

Installation, Operation, and Maintenance Manual

Universal Elevator Mount Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.

Vented VW Settlement Cell

Installation, Operation, and Maintenance Manual

Agilent 1290 Infinity Pump Head Maintenance

Preferred Instruments Danbury, CT USA

Further technical information is available on

Instruction Manual Model 4615

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

AIR/OVER HYDRAULIC JACK 20 TON

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Installation, Operation & Maintenance Manual

BGA244 Binary Gas Analyzer

Supplementary Operator s Manual 42/24-14 EN Rev. 3

OEM Manual. MODEL ½ Digit DRUM SCALE

Improving distillation tower operation

MODEL SWH10 1,000 LB CAPACITY SWIVEL HOIST

Marine 6-Boat Free-Standing Racks SKU: Updated November 2011

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Instruction Manual Model 4675

H-LEVEL _ H-LEVEL LIQUID LEVEL SYSTEM SETTLEMENT GAUGES

UltraLo 1800 Alpha Particle Counter

Installation and commissioning instructions 255 series and 256 series

MODEL WEIGH MODULE

Model PSI Compressor with 3-Gallon Air Tank 12VDC

PANACEA P200 STAINLESS STEEL USER MANUAL

SCOUT DECK ANCHOR 3 1/4" BONDING SCREW

200 PSI COMPRESSORS - MODEL NUMBERS

Level MEASUREMENT 1/2016

KERSPLASH POOL CLIMBING WALL INSTALLATION INSTRUCTIONS

Tripod Setup Guide (M-TPx)

UsER manual for Watersens ph -REDOX

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

Installation, Operating, Inspection and Maintenance Instructions Ladder Climber s Safety System. Warning

WKM Model 320F Floating Ball Valve

Instrumentation & Data Acquisition Systems

_ pressure transducers. User Manual

PANACEA P100 LOW PRESSURE USER MANUAL

Rapidmain Installation Guide

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

Differential Pressure Transmiter

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

PH01 Perfusion Cannula Manual

PANACEA P125 USER MANUAL

BPS-2, Rev TABLE OF CONTENTS

T EK-SUB 4800C 19 mm Submersible Level Transmitter

CO2 Tank Conversion Kit P.N , P.N , and P.N

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Hydrostatic & Submersible. Level instruments. for the Australian market

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

Constant Pressure Crude Oil Container Model CPCCP

Quick Installation Guide Doc nr.: C Date:

ENERGY BLADE 3K4. Energy Blade Installation Instructions

Torque Tube TB300 Digital Transmitters

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Preliminary filter Precision measurement chamber Flow meter Instruction manual

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

100C Air Compressor Kit

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Coriolis Mass Flow Meter

SEMIC05 Installing mechanical equipment

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

Installation, operating and maintenance Instructions for Seemag bypass level indicator

User s Guide. Pressure Controller for liquid delivery systems

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

TABLE OF CONTENTS FRAME FEATURES INTRODUCTION

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Transcription:

Precision Liquid Settlement Array Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change the information at any time and assumes no liability for its accuracy. Copyright 2017. RST Instruments Ltd. All rights reserved. Document Number: SSS00067 A Release Date: April 27, 2017 RST INSTRUMENTS LTD. 11545 Kingston St., Maple Ridge, BC CANADA V2X 0Z5 SALES + SERVICE + MANUFACTURING: 604 540 1100 info@rstinstruments.com TOLL FREE (USA & Canada) 1-800-665-5599 SSS00067 A www.rstinstruments.com

TABLE OF CONTENTS 1 INTRODUCTION... 3 2 PRACTICAL THEORY... 4 3 SAFETY... 4 4 INSTALLATION... 4 4.1 Installation Tools and Components... 4 4.2 Installation Preparation... 5 4.3 Installation Procedure... 6 4.3.1 Mounting the Precision Liquid Sensors... 6 4.3.2 Mounting the Precision Liquid Reference Sensor... 7 4.3.3 Mounting Fluid Expansion Chamber... 7 4.3.4 Filling the System with Liquid... 8 5 OPERATION... 9 5.1 Survey the Reference Cell... 9 5.2 Collect Readings... 9 6 SERVICE AND REPAIR... 9 APPENDIX A PRECISION SENSOR DETAILS... 10 APPENDIX B FLUID EXPANSION CHAMBER DETAILS... 11 APPENDIX C SAMPLE CALIBRATION CERTIFICATE... 12 LIST OF FIGURES Figure 1-1 Precision Liquid Settlement System... 3 Figure 3-1 Precision Liquid Settlement Sensor... 7 Figure 3-2 Precision Liquid Settlement Fluid Expansion Chamber... 8 No table of figures entries found. LIST OF TABLES SSS00067 A RST Instruments Ltd. Page ii

1 INTRODUCTION The Precision Liquid Settlement Array provides reliable, real-time monitoring of relative settlement and heave which may occur at excavation sites, tunnelling projects, underground openings and related applications. It is ideal for monitoring structures near underfills, preloads, embankments, and grouting. The Precision Liquid Settlement Array provides wired or wireless remote monitoring. Users have real-time access through an internet connection on a computer and can also receive updates via email at chosen intervals. The system is comprised of a sensor connected to liquid pressure and air compensation tube and an electrical cable with M12 connectors. Three settlement measuring ranges (0.6, 1.2, and 3 m) are available for ordering and are chosen based on site conditions and anticipated settlement by the site engineer. Settlement is measured by comparing the changes in liquid pressure between the sensor at the zone of interest and to the reference sensor. All measured data is digitally received. Temperature compensation is possible. FIGURE 1-1 PRECISION LIQUID SETTLEMENT SYSTEM SSS00067 A RST Instruments Ltd. Page 3

2 PRACTICAL THEORY A series of chambers (vessels) are hydraulically connected together by means of a liquid line (water-filled tube). The system is normally isolated from air. A liquid leveling system requires two different types of sensors: settlement sensors installed at the different measurement locations, and a reference sensor that is acting as a reference and is coupled to the other sensors. All settlement data are obtained by subtracting the values of this reference sensor from the settlement sensor. For accurate measurement in the mm range, a compensation tube network is used to equalize the air pressure at the location of each sensor. Since the temperature affects the liquid density, changes in ambient temperature can influence the readings of the settlement. To minimize the effect of temperature changes, temperature is measured along with pressure in each sensor location. The fluid level change measurements are then compensated for temperature changes. 3 SAFETY WARNING: USED WHEN AN OPERATING PROCEDURE OR PRACTICE, IF NOT CORRECTLY FOLLOWED, COULD RESULT IN PERSONAL INJURY OR LOSS OF LIFE. CAUTION: USED WHEN AN OPERATING PROCEDURE OR PRACTICE, IF NOT STRICTLY OBSERVED, COULD RESULT IN DAMAGE TO OR DESTRUCTION OF EQUIPMENT. NOTE: USED TO HIGHLIGHT SPECIFIC NON-SAFETY RELATED INFORMATION. 4 INSTALLATION 4.1 INSTALLATION TOOLS AND COMPONENTS Ensure all tools and components required for the installation are present prior to installing the Precision Liquid Settlement System. Tools and equipment required for a typical installation include: Precision Liquid Settlement sensors and fluid reservoir. Campbell Logger or RST DT2485 data logger. Digital cable with M12 4-pin male cable connectors. SSS00067 A RST Instruments Ltd. Page 4

½" O.D. HDPE liquid tube. ¼" O.D. Nylon 11 air tubing. Anchor kit with 25 mm M8 anchors. Hilti Flush anchor HKD M8x25 or equivalent. Anchor setting tool (carbon steel). Hex wrench. Level. Hammer drill and 10mm hammer drill bit. 4.2 INSTALLATION PREPARATION Determine the installation location for the Precision Liquid Settlement System. The location must allow access for sensor connections after the system has been mounted. CAUTION: AVOID CHOOSING AN INSTALLATION LOCATION IN AREAS OF RAPID OR EXTREME CHANGES IN TEMPERATURE, SUCH AS IN DIRECT SUNLIGHT OR NEAR HEATING OR COOLING EQUIPMENT. SUN SHADES AND/OR EXTERNAL INSULATION IS RECOMMENDED FOR EXPOSED UNITS. TUBING SHOULD NOT BE INSTALLED IN AREAS WITH TEMPERATURES BELOW -10 C. General guidelines for installation planning include: Securely attach the mounting angles with the supplied hardware to a rigid structure that is free of vibration. The brackets are designed to be bolted to a wall or a pedestal and should be firmly attached with either anchor bolts or epoxy grouted studs. Minimize the height difference between the sensors. Remove unnecessary liquid tubing length to minimize the total height of the liquid column. Install the reference sensor in a location where minimal to no settlement is expected. Boil the 50% by volume ethylene glycol solution and then cool it down to less than 40 C before use. Maintain air in front of the liquid in the tubes by filling the network from its lowest point. Connect the precision liquid sensor electronics one by one, or section by section. Run the accompanying software to ensure the connected sensors are functioning properly. This step-by-step approach will eliminate the potential for lengthy troubleshooting should the entire network be installed without intermediate checks. The installation of the sensors must be well within the measuring range of the system to allow for precise settlement measuring without risking an overload of the sensors. SSS00067 A RST Instruments Ltd. Page 5

4.3 INSTALLATION PROCEDURE 4.3.1 Mounting the Precision Liquid Sensors NOTE: ALWAYS MOUNT THE SENSORS ON A FLAT SURFACE. 1 Mark the locations of where the precision liquid sensors will be mounted. Set the initial level of all points to be the same +/- 3 mm. 2 Place the concrete anchors for the sensors. Sensors should be vertical +/- 1.5 degrees. 3 Mount the sensors. Connect the liquid and air tubing. The tubing should be cleanly cut at 90º, and assembled by inserting about 10 mm into the fitting. 4 Install the connectors on 4 conductor cables. Assemble the connections. CAUTION: FAILURE TO FOLLOW STEPS 5 11 CORRECTLY WILL RESULT IN DAMAGE TO THE CONNECTOR AND STRING. 5 Tighten the coupling nuts to a tightening torque of 0.6 Nm (hand-tight) to ensure the connectors are properly sealed. Turn the nut one notch further to a tightening torque of 1.5 Nm (approximately another ⅛ turn using a 14 mm wrench). Only apply torque on the flats of the metal coupling nuts to prevent damage on the connectors. CAUTION: ONLY APPLY TORQUE ON THE FLATS OF THE METAL COUPLING NUTS TO PREVENT DAMAGE ON THE CONNECTORS. SSS00067 A RST Instruments Ltd. Page 6

FIGURE 4-1 PRECISION LIQUID SETTLEMENT SENSOR 4.3.2 Mounting the Precision Liquid Reference Sensor The reference sensor acts as a reference for all the other sensors in the system. It is mounted and tested in the same way as the other sensors, but preferably in a fixed location that does not allow for movement, or in a location that is frequently surveyed. 4.3.3 Mounting Fluid Expansion Chamber The fluid expansion chamber is typically installed near the reference sensor. 1. Use proper anchors to attach the mounting bracket to a flat surface. 2. Connect the liquid and air tubing to the reference sensor. SSS00067 A RST Instruments Ltd. Page 7

FIGURE 4-2 PRECISION LIQUID SETTLEMENT FLUID EXPANSION CHAMBER 4.3.4 Filling the System with Liquid The filling operation should be done very carefully to exclude air bubbles from the lines. 1. Fill the system from the non-reference end with 50/50% water ethylene glycol solution, siphoning from the non-reference end. Control the flow rate by raising the source tank up to 1m above sensors. 2. Purge all bubbles out of the system. Never exceed 10 kpa water pressure. Raise the liquid line ahead of the first settlement sensor and allow the liquid to flow, chase the air ahead of the liquid by manually controlling the elevation of the liquid line as the liquid flows. Make sure there are no air bubbles in the liquid line. CAUTION: NEVER EXCEED 10 KPA WATER PRESSURE. 3. Allow the system to stabilize. Close the fluid expansion chamber purge valve. SSS00067 A RST Instruments Ltd. Page 8

5 OPERATION 5.1 SURVEY THE REFERENCE CELL Ensure that the reference cell readings are stable and did not change since installation. 5.2 COLLECT READINGS Collect readings with a Campbell logger or a RST DT2485 data logger. The output of the Precision Liquid Settlement sensors are in mm H 2 0 and are corrected for temperature. 6 SERVICE AND REPAIR The product contains no user-serviceable parts. Contact RST for product service or repair not covered in this manual. SSS00067 A RST Instruments Ltd. Page 9

Appendix A PRECISION SENSOR DETAILS SSS00067 A RST Instruments Ltd. Page 10

Appendix B FLUID EXPANSION CHAMBER DETAILS SSS00067 A RST Instruments Ltd. Page 11

Appendix C SAMPLE CALIBRATION CERTIFICATE SSS00067 A RST Instruments Ltd. Page 12