Oxylog VE300 Emergency & Transport Ventilation The straightforward and user-friendly Dräger Oxylog VE300 is built to face your challenges in preclinical emergency services With reliable ventilation technology, robustness and intuitive operation, it provides you with reliable and safe assistance in an emergency
02 Oxylog VE300 Benefits Simple, ergonomic, robust and economical: Reliable even under extreme operating conditions (-20 to +50 C) Device start in three steps, takes less than 10 seconds Device check takes less than a minute Preset parameters for fast ventilation start Replaceable and rechargeable battery for up to 9 hours of operation Low oxygen consumption thanks to DuroFlow technology* Clear user guidance with moderate training time Easily accessible documentation with Bluetooth and USB interface: patient data, system test, screen shots Wall mount permits flexible positioning Practical extras available as options: belt, stretcher mounting, accessory bag, battery charger Ergonomic carrying handle directly above the device s centre of gravity Easy to carry, quick-start ventilation Clear colour touch screen Flip-screen button rotates the display 180 Volume-controlled ventilation: VC-CMV / VC-AC, VC-SIMV Spontaneous breathing support: SPN-CPAP/PS with NIV Pressure support: PS CPR mode can be selected with a single keystroke Capnography: main-stream CO₂ measurement Logbook supports documentation *DuroFlow technology: based on the Venturi-Principle without additional base flow
Oxylog VE300 03 Related Products Oxylog 1000 The Oxylog has been the natural choice of emergency care ventilator for more than 25 years The Oxylog 1000 is the most compact ventilator in the Oxylog range MT-4300-2007 MT-8906-2009 Oxylog 2000 plus Step up your performance with Oxylog 2000 plus The Oxylog 2000 plus supports you in your daily challenge of saving peoples lives, no matter where the call takes you Invasive or non-invasive, Oxylog 2000 plus can meet this challenge by putting essential ventilation tools at your fingertips The Oxylog 2000 plus can make all the difference Dräger Oxylog 3000 plus Offering high ventilation performance with features such as AutoFlow integrated capnography and non-invasive Ventilation, the compact and robust Oxylog 3000 plus helps you transport your patients safely and provides feedback on correctness of intubation and ventilation effectiveness The Oxylog 3000 plus gives you confidence to master even the most demanding situations D-9219-2009
04 Oxylog VE300 Technical Data Device specifications Dimension (W x H x D) Basic device Basic device, with carrier system Weight Basic device, without battery Basic device, with battery Basic device, with carrier system, battery and bag Screen Technology Size External connections USB Sound pressure level (SPL) Average sound pressure level Leq(A) (Free-field measurement at 1 m distance according to ISO 3744, with typical ventilation): Sound pressure level L(A) of alarm signals (measured according to IEC 60601-1-8) 399 x 153 x 160 mm (157 x 68 x 63 inches) 580 x 222-245 x 160 mm (228 x 87-96 x 63 inches) Approx 33 kg (73 lb) Approx 36 kg (79 lb) Approx 56 kg (124 lb) TFT colour screen 43 inch 20 Only passive, ie do not connect storage media without an independent electrical power supply 45 db (A) Approx 60 to 70 db(a), depending on alarm priority Ambient conditions Operating conditions Temperature (device) Temperature (power supply) Ambient pressure (device) Height above sea level Ambient pressure (power supply) Relative humidity -20 C to +50 C (-4 to +122 F) 0 C to +50 C (+32 F to +122 F) 620 to 1,100 hpa (899 to 1595 psi) Automatic ambient pressure compensation within this pressure range Up to 4,000 m (13,123 feet) 700 to 1,200 hpa (1015 to 1595 psi) 5 to 95% (without condensation) Settings Ventilation modes Optional Respiratory rate RR VC-CMV, VC-AC, SPN-CPAP VC-SIMV/PS, SPN-CPAP/PS 2 to 50 /min (VC-SIMV) 5 to 50 /min (VC-AC, VC-AC) Maximum airway pressure Pmax 20 to 60 mbar (20 to 60 cmh 2 O) Ratio of inspiration time to expiration time I:E 1:4 to 4:1 Inspiration time Ti Tidal volume VT O 2 concentration 03 to 10 s 01 to 20 L, BTPS Measured values based on patient's lung conditions, body temperature 37 C (986 F), ambient pressure, water vapour-saturated gas 100% O 2 and O 2 /air mixture Actual value depends on inspiratory flow and mean airway pressure Positive end-expiratory pressure PEEP 0 to 20 mbar (0 to 20 cmh 2 O) Trigger sensitivity (flow trigger) Trigger sensitivity (pressure trigger) 1 to 15 L/min 1 to 15 steps
Oxylog VE300 05 Technical Data Pressure support ΔPsupp 0 to 35 mbar (0 to 35 cmh 2 O) (relative to PEEP) Pressure rise time for pressure support slow (1 s), standard (04 s), fast Regions of alarm limits MVe high MVe low RR high etco 2 high etco 2 low 2 to 60 L/min 05 to 40 L/min 10 to 99 /min 5 to 99 mmhg / 05 to 132 kpa / 05 to 132 vol% 0 to 94 mmhg / 0 to 127 kpa / 0 to 127 vol% Performance characteristics Control principle Maximum inspiratory flow 100 L/min 1 Device compliance Time-controlled, constant volume, pressure monitored with 15 m breathing tube < 15 ml/mbar (15 cmh 2 O) with 30 m breathing tube < 2 ml/mbar (2 cmh 2 O) Inspiratory and expiratory resistance of the device with breathing tube system, with Plus option Inspiratory and expiratory resistance of the device with breathing tube system, without Plus option Emergency air valve Safety valve < 6 mbar (6 cmh 2 O) at 60 L/min < 4 mbar (4 cmh 2 O) at 30 L/min < 2 mbar (2 cmh 2 O) at 5 L/min < 6 mbar (6 cmh 2 O) at 60 L/min < 4 mbar (4 cmh 2 O) at 30 L/min < 2 mbar (2 cmh 2 O) at 5 L/min Opens breathing system if there is insufficient gas and enables spontaneous breathing with room air Opens breathing system if device fails at about 80 mbar (80 cmh 2 O) 1 At supply pressure > 350 kpa (5076 psi) At a supply pressure < 350 kpa (5076 psi), the maximum inspiratory flow is reduced to 80 L/min, at a supply pressure < 280 kpa (4061 psi) to 39 L/min Values displayed Airway pressure measurement 0 to 100 mbar, BTPS Resolution 1 mbar (1 cmh 2 O) Accuracy ±(2 mbar (2 cmh 2 O) +2% of measured value) Flow Measurement Minute volume MVe Resolution Accuracy Tidal volume VTe Resolution Accuracy CO 2 measurement (option) Measurement basis Resolution 0 to 100 L/min, BTPS 01 L/min ± 20% of measured value or ± 04 L/min, the larger value applies 0 to 5,000 ml, BTPS 1 ml ± 20% of measured value or ± 20 ml, the larger value applies (adults-breathing tube) Main-stream method 0 to 100 mmhg / 0 to 132 vol% / 0 to 133 kpa 1 mmhg / 01 vol% / 01 kpa
06 Oxylog VE300 Technical Data Respiratory rate measurement Resolution Accuracy 0 to 99 /min 1 /min ±1 /min Graph Airway pressure Paw (t) 0 to 90 mbar (0 to 90 cmh 2 O) CO 2 0 to +100 mmhg / 0 to +15 vol% / 0 to +15 kpa Monitoring Expiratory minute volume MVe (option) Alarm, upper alarm limit If the upper alarm limit has been exceeded 2 to 60 L/min Alarm, lower alarm limit Apnoea Alarm Respiratory rate RR Alarm, upper alarm limit End expiratory CO 2 concentration - etco 2 (option) Alarm, upper alarm limit Alarm, lower alarm limit Leakage Alarm Disconnection Alarm Data communication (option) Exported data If the value has fallen below the lower alarm limit 05 to 40 L/min 40 seconds after start of ventilation If no respiratory phase change for > 15 seconds is detected If the upper alarm limit has been exceeded 10 to 99 /min 30 seconds after start of ventilation If the upper alarm limit has been exceeded 5 to 99 mmhg / 05 to 132 kpa / 05 to 132 vol% 30 seconds after connection and calibration If the value has fallen below the lower alarm limit 0 to 94 mmhg / 0 to 127 kpa / 0 to 127 vol% 30 seconds after start of ventilation, connection and calibration Only for Plus option in VC modes and with NIV switched off in CPAP: If VTe < 45% of VTi 30 seconds after start of ventilation If disconnection of the breathing tube system is detected 30 seconds after start of ventilation Measurements Curves Alarm messages Alarm settings User settings System test information Screenshots
Oxylog VE300 07 Technical Data Operating characteristics Power supply Input Voltage Operating time Power consumption Battery type Charging time 19 V + 5/-3 VDC Power supplies (power supply and DC voltage converter) are specified as parts of the Oxylog VE300 With new and fully charged battery, without external power supply: 8 hours with typical ventilation (VC-CMV, RR = 12/min, VT = 500 ml, PEEP = 5 mbar (5 cmh 2 O), I:E = 1:2) 9 hours (without CO 2 sensor and low screen brightness) While charging: max 20 A at 19 VDC With typical ventilation: max 08 A at 19 VDC Lithium-ion battery Approx 5 hours The indicated charging time refers to full charging of the battery after discharge Power supply unit Protection class (according to IEC 60601-1) Protection class Input Class II IP22 100 to 240 V~ / 50/60 Hz / 10 A Output 19 V / 447 A (0 to +40 C (32 to +104 F)) / 357 A (+40 to +50 C (+104 to 122 F)) Fuses F1 and F2 T 25 A / 250 V~ To disconnect the ventilator from the mains, pull the power cable out of the mains socket The power supply unit is designed for indoor use (eg in hospitals or fire stations) Gas supply Oxygen supply pressure Gas characteristics Connection to the oxygen supply: From a central gas supply system or an oxygen cylinder 270 to 690 kpa (3916 to 10008 psi) Medical oxygen, 93% oxygen NIST (Non-Interchangeable Screw-Threaded) according to EN 739 / ISO 5359 or DISS (Diameter Index Safety Systems) according to CGA V5-1989 or NF (Norme française) S90-116 Specific quick connection
08 Oxylog VE300 Notes Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status 91 04 149 1705-1 HQ PP Subject to modifications 2017 Drägerwerk AG & Co KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co KGaA Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom Manufacturer: Drägerwerk AG & Co KGaA Moislinger Allee 53-55 23558 Lübeck, Germany REGION DACH Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION EUROPE Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION MIDDLE EAST, AFRICA Dräger Safety AG & Co KGaA Branch Office PO Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draegercom REGION ASIA PACIFIC Draeger Singapore Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asiapacific@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL Complejo Business Park, V tower, 10th floor Panama City Tel +507 377-9100 Fax +507 377-9130 contactcsa@draegercom Locate your Regional Sales Representative at: wwwdraegercom/contact