Operation of Oxylog 3000 ventilator

Similar documents
O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

Oxylog. Emergency and transport ventilator Instructions for Use Software 1.n. Because you care

Oxylog 3000 plus Emergency & Transport Ventilation

Oxylog Emergency and transport ventilator Instructions for Use Software 1.n. Because you care

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Dräger Savina Sub-Acute Care Ventilation

Instructions for Use Oxylog 2000 plus

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

e700 Automatic Transport Ventilator User Manual e700 User Manual (15PL Rev.14 28_8_2017)

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

Instructions for Use Oxylog 3000 plus

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

Dräger Medical. Savina. Intensive Care Ventilator. Instructions for Use Software 2.n. mt78799

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Complex Care Hub Manual: Pressure Ventilation on the LTV 1200

e600 Automatic Transport Ventilator User Manual e600 User Manual (15PL Rev.7 28_8_2017)

Ventilator Training Module

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Automatic Transport Ventilator

ASSISTANCE. Cardinal Health Pulmonetic Systems Medina Rd., Suite 100 Minneapolis, Minnesota

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Oxylog VE300 Emergency & Transport Ventilation

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

DATA SHEET. VENTILATION SERVO-s

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Tafonius. Auxiliary Mode Operating Manual A USERS GUIDE

Using Common Ventilator Graphics to Provide Optimal Ventilation

Technical Data and Specifications

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

Ventilators. Dr Simon Walton Consultant Anaesthetist Eastbourne DGH KSS Basic Science Course

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

e500 Automatic Transport Ventilator User Manual e500 User Manual (15PL Rev.7 6_6_2017)

IMPACT. Uni-Vent. Eagle. Model 754 Portable Ventilator

Understanding and comparing modes of ventilation

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

S/5 Aespire. Quick Reference Guide

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity

Babylog 8000 plus. Intensive Care Ventilator for Neonates Software 5.n Instructions for Use

Software enhancements

Operator s Manual Addendum

Better to have one OXYLOG 3000

SLE5000 Neonatal Ventilator with High Frequency Oscillation

Evita 4 Intensive Care Ventilator

A9600 Anesthesia Workstation. Your healthcare, we care.

Tafonius Junior A USERS GUIDE. v10mar2011

Apollo Safety Features

How Ventilators Work. Chapter 3

Oxylog 2000 plus Emergency & Transport Ventilation

Operation and Maintenance of the EPV200 Portable Ventilator

AV-S Ventilator User Manual


AUTOVENT 4000 VENTILATOR

Mechanical Ventilation

Siesta i Whispa Integrated technology

SLE5000 Infant Ventilator with HFO

SERVO-s v8.0 Data sheet

Anesthesia Workstation

Hospital and Transport for Controlled Breathing

Technical Documentation Oxylog 2000 Emergency Ventilator

2 OVERVIEW OF VENTILATOR

The Merlin Small Animal Ventilator by Vetronic Services Ltd. Contents page. Introduction.2. Features of Merlin. 3

Emergency Transport and Ventilation

The SAV04 Small Animal Ventilator. Contents Page

AV-S Ventilator. Service Manual. Partnership for Life. Remote Display Module and Interface for use with A200SP Absorber

An intuitive and innovative answer to your anaesthesia challenges

Your patients, our primary focus

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Oxylog Emergency Ventilator Instructions for Use Software 3.n. Because you care

Draft Copy July AV-S Ventilator. Partnership for Life. Service Manual. Remote Display Module and Interface for use with A200SP Absorber

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

Indications for Mechanical Ventilation. Mechanical Ventilation. Indications for Mechanical Ventilation. Modes. Modes: Volume cycled

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

FLIGHT 50 Ventilator

Selecting the Ventilator and the Mode. Chapter 6

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

Guide to Understand Mechanical Ventilation Waveforms

Blease900 Ventilator PATIENT CENTERED VENTILATION

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Aims&and&objec5ves& The&Basics&of&Mechanical& Ven5la5on& 30/01/2012&

Ventilation modes in intensive care

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

Dameca MRI 508. State-of-the-art MRI technology

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

LP6 Plus Volume Ventilator -And- LP10 Volume Ventilator With Pressure Limit

Airox Supportair Ventilator

e360t and e360t+ Model

Transcription:

Operation of Oxylog 3000 ventilator Overview Suitable for patients from approximately 7Kg body weight upwards (smallest tidal volume 50mls). Entirely power dependant- will not ventilate if no available internal or external power source. Internal battery has approximately 4 hour life when fully charged. Figure 1 Oxylog 3000 control panel A Screen with screen pages for the specific application B Alarms Key C Settings Key D Key for ventilation mode CPAP ASB E Key for ventilation modes IPPV F Key for ventilation mode SIMV ASB G Key for ventilation mode BIPAP ASB H Red and yellow lamps as alarm indicators I Alarm silence Key (muting the alarm tone for 2 minutes) J Alarm Reset (acknowledging alarm messages) K 100% O2 button (deliver 100% oxygen for 3 minutes). L Inspiratory Hold Key M Power Key (On/Off) N Display symbols for the power supply (Mains power/ Charge capacity of the internal battery) O Central rotary knob for making selections / settings and for confirming these P Control knob for setting the O2 concentration to between 40 % or 100 % Q Control knob for setting the maximum inspiratory pressure R Control knob for setting the ventilation frequency S Control knob for setting the tidal volume T Explanation of colour codes for quick setting tidal volume/ventilation frequency U Curves Key (zooming the curve display and changing over between "Flow" and "Paw" curves) V Values Key (displaying measured values)

Setting up the Oxylog 3000 1. Connect the gas supply The ventilator is gas-driven, so needs a pressurised supply of oxygen to make it work. Make sure oxygen supply is connected and turned on. If Oxygen not connected/turned off the ventilator will not cycle. 2. Connect disposable hose set Connect the blue flow measuring hose to the blue socket and transparent flow measuring hose to the other socket. Ensure correct placement or measured volumes may be inaccurate. Currently using Dräger disposable hose and so select Paediatric Disposable Hose [DISP] on hose selection screen- see below. NB: Dead space volume (i.e. gas not contributing to ventilation) may be 30-40 mls using disposable hoses and may lead to re-breathing of CO 2 if using Oxylog with lower Tidal Volumes. End Tidal CO 2 monitoring should be used at all times. 3. Turning on the ventilator Turn on the ventilator by briefly pressing the power key (M). The device will run through a short self-test and prompt a device check by displaying Press rotary knob for device check and configuration. If required press the rotary knob to confirm. Select Device check and follow the on screen instructions.

If the rotary button is not pressed during the self-test the Hose selection page is displayed. Select Paediatric Disposable Hose by rotating the rotary knob (O) and confirm by pressing the rotary knob (O).

Using the Oxylog 3000 Display operating controls B C D E Key Values to change screen pages in the Measured Values window. Key Curves to change between the pressure or flow curves in small and large presentation. Key Settings to display ventilation parameters (ventilation screen) in the Settings and Alarms window. Key Alarms to display alarm settings in the Settings and Alarms window. Ventilation Modes Having completed the self-test the ventilator will default to the manufacturers default settings (IPPV (CMV)). To select a different ventilation mode either press the key for the ventilation mode for 3 seconds or briefly press key for ventilation mode and confirm by pressing the rotary knob. Modes of ventilation available 1. IPPV or IPPVAssist- Intermittent Positive Pressure Ventilation is volume controlled mode with a fixed minute volume adjusted by changing Tidal Volume and Frequency Trigger value (under settings) can be adjusted to allow synchronisation with patient s respiratory effort with a lower value resulting in higher sensitivity i.e. easier triggering. Trigger values below 3 L/min and over 15 l/min will deactivate triggering. Successful triggering is briefly indicated by an asterisk (*) appearing in the middle of the top line of the screen. 2. SIMV or SIMV/ASB- Synchronised Intermittent Mandatory Ventilation, with or without, Assisted Spontaneous Breathing is a fixed mandatory minute volume set with tidal volume and frequency. The patient can breathe between mandatory breaths and this can be assisted with ASB. 3. BIPAP or BIPAP/ASB- Biphasic Positive Airway Pressure, with or without, Assisted Spontaneous Ventilation is pressure controlled ventilation coupled with spontaneous breathing throughout and variable pressure support at CPAP level.

4. CPAP or CPAP/ASB- Continuous Positive Airway Pressure, with or without, Assisted Spontaneous Ventilation is a spontaneous breathing mode at an elevated pressure to maintain lung volume. Can also assist spontaneous breaths with ASB. NB if no spontaneous effort then will deliver SIMV breaths as per Apnoea ventilation settings on screen. Can adjust Apnoea time (range 15-60 seconds), tidal volume and frequency. To end Apnoea ventilation press the Alarm reset key. Mode Controls below screen Controls on screen IPPV or IPPVAssist SIMV or SIMV/ASB BIPAP or BIPAP/ASB CPAP or CPAP/ASB Tidal Volume Frequency (minimum 5/min) Tidal Volume Frequency (minimum 5/min) Frequency (minimum 5/min) I:E ratio PEEP Plateau Time (IPPVAssist) Inspiration time PEEP Pressure Support (ASB) Plateau Time Pressure Rise time/ramp Inspiration time Inspiratory Pressure PEEP Pressure Rise time/ramp Pressure Support (ASB) Pressure Rise time/ramp Table 1 Control parameters by mode of ventilation Pressure Support (ASB)

Alarms Error messages are classified according to three priority levels as indicated by exclamation marks!!! Warning =Message with top priority!! Caution =Message with medium priority!advisory =Message with low priority In the event of an alarm the indicator lights (shown as H on Figure 1) will either flash red/yellow or light yellow A message will appear on the upper right corner of the screen An audible alarm will sound When the fault is remedied the audible alarm will be silenced but the message will remain on screen until either acknowledged by pressing the alarm reset key or replaced by a new alarm message. Alarm tones can be suppressed for 2 minutes by pressing the alarm silence key. After use The Oxylog 3000 can be turned off by pressing and holding the power key for approximately 3 seconds. An audible high priority alarm will sound to check that ventilation has stopped. Either then press the rotary know to confirm power off or press the power button to restart ventilating at the last settings. Dispose of all hoses and filters and ensure that device is left plugged in to charge the internal batteries.