dpd Seattle Permits Tip Getting a Grip on Handrails PURPOSE OF HANDRAILS

Chapter 5. General Site and Building Elements

CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS

Small. Regulation Reference: (see page 23 for link to the regulation)

CTC Area of study Climbable Guards 2007/2008 Code Changes SECTION GUARDS

ADA Library Accessibility Checklist

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 8 RECREATION FACILITIES

TOWN of CHEEKTOWAGA Permit Application for Swimming Pools, Hot Tubs, or Personal Spas

i. f ;->s- Handrails & Railings Safe Stairs LD ~ V.P.I. & S.U. LIBRARY RECOMMENDATIONS: from the series Design for Safe Habitat

ACCESSIBILITY STANDARDS for the BUILT ENVIRONMENT

FINDLAY TOWNSHIP BUILDING INSPECTION DEPT

BP 344 IMPLEMENTING RULES AND REGULATIONS (IRR) AMENDMENTS MINIMUM REQUIREMENTS FOR ACCESSIBILITY

Town of Poughkeepsie Received: Permit # Aboveground/Inground Pool Building Permit Application

Location: Cariboo, One Hundred Mile House, Cariboo Chilcotin Coast - Provincial : Park (Heritage Discovery Circle Route)

Advanced Code Requirements for Residential Construction Internet Course

FINAL EXPRESS TERMS FOR PROPOSED BUILDING STANDARDS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HELATH

PEAK ALUMINUM FENCING AQUATINE Review for compliance with 2015 International Swimming Pool and Spa Code

IBC: 404.1, 404.9, , , , , , TABLE

MSC Guidelines for Review of Emergency Evacuation Plans (Subchapter K)

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Why Update. OSHA updated Walking Working Standard. Who & What it Covers. Housekeeping (a) 6/25/ nd Leading cause of Workplace fatalities

NEW ZEALAND BUILDING CODE. In relation to Tredsafe

Residential Swimming pools

AMITY TWP POOL REQUIREMENTS

Field guide for Accessible Public Rights-of-Way Edition

ADA COMPLIANCE CHECKLIST (RESTAURANT) Meet Fail N/A. Parking Lot

Norton Shores Building Division 4814 Henry Street, Norton Shores, Michigan Telephone: (231) Pool Requirements

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

RESIDENTIAL BUILDING PLAN REVIEW CHECKLIST

Segment Number Quick Pathways Accessibility Tool. Name of Street: Segment Identification:

PERMANENT POOLS. Location

*A Certificate of Survey for the property may be on file at City Hall if the house was built after 1984.

CITY OF CORNER BROOK SWIMMING POOL REGULATIONS

TOWN OF AURORA. Pool Enclosure Permit Guide. PLANNING AND BUILDING SERVICES Building Division

CPWR - The Center for Construction Research and Training. Fall Hazard Identification and Control Audit of the Aria Building. City Center Project

OSHA 29CFR 1910 Subpart D Walking-Working Surfaces Content

RESOLUTION A.1045(27) RECOMMENDATION ON PILOT TRANSFER ARRANGEMENTS

FALL PROTECTION LADDERS ACCESSWAYS

RESIDENTIAL SWIMMING POOL REQUIREMENTS

Palmer township, Pennsylvania. Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

Swimming Pools, Hot Tubs and Spas

Check with local zoning official for property line distance requirements.

Swimming Pool Installation

REAR YARDS - There shall be a rear yard no less than forty (40) feet.

Subparts D and I Walking-Working Surfaces & Personal Protective Equipment Final Rule

Pool Barrier, Fence, Gate, Closer and Alarm Requirements

ARTICLE V - AGRICULTURAL SUBURBAN ESTATE RESIDENTIAL - A- SER

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

WORKPLACE SAFETY INSPECTIONS TABLE OF CONTENTS INTRODUCTION...2 OBJECTIVE...2 REFERENCES...2 PREREQUISITES...2 PRECAUTIONS...2 CHECKLISTS...

Swimming Pool Requirements

Palmer township, Pennsylvania. Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

Building Code Guidelines for Residential Pools

Accessible Swimming Pools and Spas

SWIMMING POOL REQUIREMENTS

BULLETIN SP b. All doors providing direct access from the home to the pool must be equipped with a self

THE CORPORATION OF THE TOWN OF GREATER NAPANEE BY-LAW NO

Design Overview. Section 4 Standard Plans for Design. Pedestrian Access Routes. Pedestrian Access Routes. Overview. Cross Slope

Three Springs Design Guidelines Fencing and Wall Standards

PEAK ALUMINUM FENCING AQUATINE Review for compliance with 2014 Florida Building Code and 2014 Florida Building Code Residential

POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS

Van Ness Avenue Bus Rapid Transit

Walking-Working Surfaces

Walking Working Surfaces Compliance Checklist

CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER MISSION VIEJO, CA (949)

BUILDING CODE COMMISSION

Safety barriers surrounding a swimming pool area at 60A Goldflats Lane, Coatesville, Rodney

MSC Guidelines for Review of Emergency Evacuation Plans (NVIC 8-93)

Whitehall Township Swimming Pool, Spa and Hot Tub Code Guide

Preventing Falls on Stairs

ADA Design Overview. Section 2. ADA Design Overview. Pedestrian Access Routes. Pedestrian Access Routes. Overview

Homeowner s Safety Guidelines for Home Pools

Model Rollguard A-Frame Safety Ladder

Building Code Guidelines For Home Pools

ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW

VISUAL AIDS FOR DENOTING OBSTACLES

MSC Guidelines for the Review of Mobile Offshore Drilling Unit (MODU) General Arrangement Plans Procedure Number: C2-36 Revision Date: 10/18/2016

National Grain and Feed Association. NGFA Guidance Document for OSHA Walking-Working Surfaces (D)

Swimming Pool Fence Guide Kodiak Iron

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

Building Code Guidelines For Home Pools

RESIDENTIAL SWIMMING POOL

Information Required on Building Permit Applications and Building Plans for the Installation of Swimming Pools, Spas, and Hot Tubs

Park Inspection Details From 7/21/2013 To 7/21/2013

Overview. Identify fall hazardous areas Describing potential fall hazards How appropriate portable and extension ladders are used

Swimming Pool Barrier 2015 International Swimming Pool and Spa Code

Requirements for Swimming Pools

ZONING ORDINANCE UPDATE (ZOCO DRAFT ): ADMINISTRATIVE PRACTICES AND DETERMINATIONS RELATED TO BULK, COVERAGE AND PLACEMENT

X-PRESS STAGE SYSTEM OWNER S MANUAL. TOOLS REQUIRED Allen Wrench (provided)

SAFETY PROGRAM MANUAL INJURY & ILLNESS PREVENTION PROGRAM

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

Welcome to the AccessibilityOnline Webinar Series

1/2 METER FLYTE-DECK II FIBERGLASS STAND (6' BOARD) (8' BOARD) (10' BOARD)

VISUAL AIDS FOR DENOTING OBSTACLES

Swimming Pool Requirements

Fall Protection Resource Guide P AGE 1

City of Naperville Transportation, Engineering & Development (T.E.D.) Services Team

RULES PUBLICATION NO. 44//P PILOT TRANSFER ARRANGEMENTS July

KERN COUNTY PUBLIC HEALTH SERVICES DEPARTMENT ENVIRONMENTAL HEALTH DIVISION

Chapter 10 SWIMMING POOLS

Transcription:

SINGLE FAMILY DWELLING STAIRWAYS, GUARDS HANDRAILS INFORMATION GUIDELINE 19 January 2017 CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA 92025 (760) 839-4647 PLEASE NOTE: THIS GUIDELINE IS INTENDED FOR USE IN SINGLE-FAMILY DWELLINGS ONLY. REQUIREMENTS DIFFER FOR OTHER OCCUPANCIES AND SOME STAIRWAY TYPES ARE NOT ALLOWED. Single Family Dwellings. Stairways Guards & Handrails Guideline19.doc Page 1 of 5

Width Stairways shall not be less than 36 inches wide. The handrail may project a maximum of 4 ½ inches into this dimension. 2016 CRC R311.7.1. SINGLE FAMILY DWELLING Stairways/Guards/Handrails Dimensional Tolerances The largest tread depth or riser height within any stairway shall not exceed the smallest by more than 3/8 inch. 2016 CRC R311.7.5.1. 2016 CRC R311.7.5.3 Risers & Treads If you are building a new standard residential stairway (not a spiral), each step (or riser) shall not be more than 7 ¾ inches high. Treads are the flat surfaces that you step onto. For new stairs, the treads shall be a minimum of 10 inches deep from front to back (not counting the part underneath the nosing of the tread above). The exposed edge of the tread is called nosing. The nosing must project at least 3/4 inch, but not more than 1 ¼ inches. The steps in a flight of stairs need to be uniform to avoid tripping. The code allows only 3/8-inch difference between the largest and the smallest rise, and only 3/8- inch difference between the largest and smallest tread measured from front to back. 2016 CRC R311.7.5.(1)(2). Headroom``````````````````````````````````````````````````````````````````````````````````````````````` `````````````````````````````````````````````````````````````````````````````````````````````````` Every stairway shall have a headroom clearance of not less than 6 feet 8 inches. This is measured vertically from the sloped plane adjoining the tread nosings or from the floor surface of the landings. Guideline19.doc Page 2 of 5

Handrails Required at four or more risers. The top shall be placed not less than 34 inches, nor more than 38 inches above the nosing of the treads. Ends shall be returned or terminated in newel posts or safety terminals. All required handrails shall be continuous for the full length of the stairs from a point directly above the top riser. Exceptions: Handrails may be interrupted by a newel post at a turn. A volute, turnout or newel post is allowed over the lowest tread. Summary: Stairways shall have a handrail if the stairway has four or more risers. Handrails may project over stairs by 4 ½ inches maximum on each side of the stairway. Handrails shall be continuous for the full length of the stairs. They must return into the wall or butt into a post, or be continuous into an adjacent stair flight. Handrails attached to the wall shall have a space between the wall and the rail of at least 1 ½ inches to provide a graspable surface. Handrails on the open side of a stairway shall meet guard requirements. 2016 CRC R312.1. For occupancies in Group R-3 guards whose top rail also serves as a handrail shall have height not less than 34 inches and not more than 38 inches measured vertically from the leading edge of the stair tread nosing. The height of handrails is measured vertically from the nosing of the tread to the top of the handrail. A handrail along a wall must be between 34 to 38 inches high. A round handrail shall have a diameter no smaller than 1 ¼ inch and no larger than 2 inches, so that it can be easily and securely gripped. Other handrail shapes are allowed if the perimeter dimension is at least 4 inches and not more than 6 ¼ inches, with a cross section dimension not more than 2 ¼ inches. Guideline19.doc Page 3 of 5

Illumination All interior and exterior stairways shall be illuminated. 2013 CRC R303.7 2016 CRC R303.7 Guards A guard is required to minimize the possibility of falling from a balcony, deck, landing, etc., more than 30 inches above the floor or ground below. Guards shall be at least 42 inches high, except that a guard may be 34 inches minimum and 38 inches maximum in R-3 occupancies where the top rail also serves as a stair handrail. 201 CRC R312.1.2(2) Guards on the open side of stairs in R-3 occupancies must have some kind of a pattern, so that a 4 3/8 inch sphere cannot pass through. However, all exterior guards along raised floors, landing, porches, decks, and balconies shall have intermediate rails or ornamental closures that do not allow passage of a 4 inch sphere. At the bottom edge of a guard along a series of steps, the space between the tread, riser and the guard shall be small enough to prevent a 6 inch sphere from passing through. Landings Any exterior entry/exit door shall have a landing at least 3' x 3' inside the door before a step occurs. The interior landing must not be more than 1 ½ inch below the top of the threshold. On the outside of the door, the step down may be 7 ¾ inches before another 3' x 3' minimum landing is required and the door does not swing over the stairs. After the landing there may be additional steps. Guideline19.doc Page 4 of 5

Winder Stairs Spiral Stairs Stairways that turn a corner, with treads that are narrow on one end and wider at the other, are called winder stairs. Winder stairs shall be at least 6 inches deep at their narrowest point. All treads shall be at least ten inches wide, measured 12 inches from where they are the narrowest. Although the tread size varies on winder stairs, there may not be more than 3/8 inch variation between the largest and smallest rise. Spiral stairway treads shall be at least 7 ½ inches deep measured 12 inches out from where they are the narrowest. The risers shall not be more than 9 ½ inches high. The minimum width of a spiral stairway from the center pole to the outside edge of the tread is 26 inches. Each spiral stair tread shall be identical. Headroom may be 6 feet 6 inches minimum. Guideline19.doc Page 5 of 5