BODYGUARD 2CH TWIN CHANNEL INFUSION PUMP

Similar documents
Multi Channel Solutions

Alaris Pump module FAQs

CONTENTS DESCRIPTION INTENDED USE. WARNINGS & NOTES. PRECAUTIONS. INSTALLATION & SET-UP (Including battery charging & powering up)

Volumat Agilia _Volumat_Presentation_customer.ppt

Making Life Easier Easypump II

Nimbus II PainPRO Ambulatory Infusion Pump

Negative Pressure Wound Therapy

CADD-Micro. Model 5900 Operator s Manual. Note: Colors are Black and Cyan (as second color) Deltec. Ambulatory Infusion Pump

Nimbus II PainPRO Ambulatory Infusion Pump

Compatible Baxter IV Sets

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Portable Oxygen Concentrator. Give your patients more freedom with mobile oxygen on demand

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

Precision digital pressure gauge Model CPG1000


Peristaltic Infusion Pump AP 31P OPERATOR S MANUAL

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

DATA SHEET. VENTILATION SERVO-s

Description. Measuring Device 3760XBI USP. Balancing

A9600 Anesthesia Workstation. Your healthcare, we care.

Digital pressure gauge Model CPG500

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

Infusion. 1 evercare inline

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

SLE5000 Infant Ventilator with HFO

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Crono PAR. Ambulatory infusion pump NEW MODEL USER GUIDE

Instructions for Use

Hand-held pressure calibrator with integrated pump Model CPH6600

Optical Dissolved Oxygen Meter

Pneumatic high-pressure controller Model CPC7000

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

CYTO. Safe Preparation and Administration of Cytostatics

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

Industrial pressure controller Model CPC4000

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

The next generation of Blood and Fluid Warming

PUMP WITH FIXED FLOW RATE. Instructions for Use

The Univentor 1250 Anaesthesia Unit

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides

Optical Dissolved Oxygen Meter

Introduction. Medley TM Medication Safety System. Alaris Medical Systems

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management

User Manual Article number: I

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Contents. 6. Infusion Mode...10

Panther 5 Acute Care Ventilator

NIMBUS range. with people in mind

DYNAMIC COMPRESSION THERAPY

SF 6 Product Guide. Gas Analysis Instruments and Accessories

Oxygen Dialflow Meter. Instructions for Use

Oxymax COS61/COS61D. Technical Information

User Manual for use with the

BETTER SAMPLE CARE. Spark Holland introduces. SPH1299 UHPLC Gradient Pump

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Rad-57 Pulse CO-Oximeter

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM

User manual CF8-D/W-IN

V8800 Ventilator System. Your healthcare, we care.

Anesthesia Workstation

Clinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

CRONO S-PID 30 Ambulatory infusion pump

MANY REQUIREMENTS - ONE SOLUTION: SCENTY control

Oxygen Dialflow Meter. Instructions for Use

INTRODUCING CARDIOSAVE Hybrid MORE THAN A PUMP. A REVOLUTION. SPECIFICATIONS

Digital Inflation Equipment

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Digital pressure gauge Model CPG500

DIAGNOSTIC CARDIOLOGY

Manifolds & pressure reducing sets

PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES

Visualize Nitrogen Gas Consumption

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

The next generation of Blood and Fluid Warming

SERVO-s v8.0 Data sheet

Portable Oxygen Concentrator. Introduction

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Table of Contents. isleep 20 clinician s manual

Additel 761 Automated Pressure Calibrators Selection Guide

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

Oxylog 3000 plus Emergency & Transport Ventilation

WARNING: EXPLOSION HAZARD

Instruction Manual for Configura Cushionair Portable Pump

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

INSTRUCTION MANUAL & PARTS BREAKDOWN

Defibtech s Latest Advancement The Lifeline ARM Automated Chest Compression (ACC) Device for Professionals

FPG8601 Force Balanced Piston Gauge

The safe use of infusion devices

DIGITAL AUTOMATIC TYRE INFLATOR

Additel 761 Automated Pressure Calibrators Selection Guide

THE UNIVENTOR 400 ANAESTHESIA UNIT

Additel 761 Automated Pressure Calibrators

Transcription:

BODYGUARD 2CH TWIN CHANNEL INFUSION PUMP The BodyGuard 2CH Twin Channel Infusion Pump is an ambulatory multi-therapy pump suitable for hospital and homecare environments with five infusion programs (continuous, dose, step, TPN and intermittent).

Main Features: The piston pump mechanism ensures unparalleled accuracy and linearity of infusion, even at lowest rates to meet the standards of the most demanding specialities Configurable modes of operation which can be set to a speciality or patients understanding - TPN, continuous, step, intermittent and dose Adjustable air-in-line detection. The cumulative ultrasonic counter can be set according to local protocols Variable occlusion pressure settings, configurable to the route of infusion/ patient type A delayed start infusion option means no reminder and no additional clinical intervention needed once pump has been set up for general infusion Automatic occlusion alarm cancelling and infusion restart on resolution of inadvertent simple line kinking episodes Designed to be intuitive to program and use

Features and Applications Safety Features: Built-in event log automatically records accurate and reliable data on pump use Lockable keypad to prevent inadvertent key presses Fixed or variable code protected programmes that are configured and locked into the pump memory and can only be accessed by authorised personnel or technicians Post Occlusion Bolus Reduction System will safely release pressure from the line, following an occlusion, without administering a post occlusion bolus Pump event log accessible via INFO MENU or downloaded to PC through BodyComm software Modes of Operation: Total parenteral nutrition (TPN) Continuous Step Intermittent Dose

Intended Use: The BodyGuard 2CH Twin Channel Infusion Pump System is designed for infusion of medications or fluids requiring continuous or intermittent delivery at preciselycontrolled infusion rates through clinically acceptable routes of administration, including but not limited to: Intravenous Subcutaneous Percutaneous Intra-arterial Common Applications: Parenteral nutrition (PN) Maintenance of general fluids and medication Speak to our team who have the knowledge and experience to support you in choosing the right medical infusion products to meet your requirements.

Accessories and Consumables Accessories Blue 3 Litre Rucksack Black 2 Litre Rucksack Grey 2 Litre Rucksack Pink 2 Litre Rucksack Charger with LED 13A Plug Lead 1.8m (Straight)

The BodyGuard 2CH TM Twin Channel Infusion Pump has a range of dedicated administration sets. These are 1.2 and 0.2 micron filter and come with straight or 90 angled spike. All sets are non-dehp 1 PVC plasticized with TOTM 2, are BSE-TSE 3 free, latex free and EVA 4 free. Length and priming volume are approximate. For more information on administration sets or for product codes, please visit our website; cmemedical.co.uk. You can also contact our Customer Support team on 01253 206700 or email customersupport@cmemedical.co.uk References 1. Bis(2-ethylhexyl) phthalate, 2. Tris (2-Ethylhexyl) Trimellitate, 3. Bovine spongiform encephalopathy, 4. Ethylene-vinyl acetate.

Ongoing Support Clinical Support Network We cover the UK and work in partnership with healthcare providers to help ensure successful pump conversions and deliver device user training programmes. All our Clinical Support Specialists have backgrounds in areas such as critical care, pain management, theatre and recovery, community and palliative care. Technical Support Our Technical Support team comprises of experienced medtech engineers who ensure quality servicing, maintenance and repair of our products. Please contact our team to discuss the different levels of service support available to best suit your needs. Quality Assurance and Regulatory Support Our team of experienced Quality Assurance professionals can resolve customer complaints, conduct first line testing (in conjunction with our Technical Support team), whilst managing relations with local regulatory bodies, supplier and quality audits and regulatory approvals.

Regional Field Sales Support When you want to make informed choices about which products will meet the needs of your service and patients, our team has the knowledge and experience to talk to you, wherever you are in the UK or Ireland. Customer Support Whether you are a clinician, an engineer or a patient using CME Medical products or services, our team of experienced customer support professionals are available to deal with your enquiry.

Technical Specification Device type Flow rate Priming rate Total infused volume Piston mechanism, ambulatory infusion pump with two independent channels 0.1ml/h to 100ml/h in 0.1ml/h increments and 100ml/h to 1,200ml/h in 1ml/h increments 100ml/h to 1,200ml/h in 1ml/h increments 0.1ml to 1,000ml Pump accuracy +/- 5% KVO rate Air sensor Maximum pressure Power supply Battery Battery operation at 125 ml/hr Battery charging Alarms Dimensions Rate (max) Ultrasonic, adjustable air bubble size. Air-in-line accumulation and single bubble detection +/-155mmHg (+/-3psi) AC mains power Rechargeable, Li-Polymer, 7.4V, 1800mAh (typical) 7.5hrs infusing @ 125ml/h (both channels infusing simultaneously) Battery charging commences automatically when the pump is mounted into the charger unit (docking station) that is connected to an AC Mains source. (LED confirmation of AC Mains connected) Air/upstream occlusion, down occlusion, door open, pump paused too long (un-attended), end program, end battery, missing key, restart pump, system/technical problem, wrong TPN data, lock mode, fatal error 41mm x 149mm x 89mm

Classification Housing Weight Electrical safety Standards EMC Environmental specifications Temperature Humidity Air pressure Operating conditions Temperature Humidity Air pressure Type CF Equipment, degree of protection against electrical shock class II equipment, IPX3 protection against ingress of water ABS (fire retardant) 551g (with battery) Complies with EN 60601-1 (Medical Electrical Equipment Safety), IEC 60601-2-24 (Infusion pumps and controllers), IEC 60601-1-4 (Programmable Electrical Medical System) Manufactured in accordance with ISO 9001;2008 and ISO 13485;2003. CE marked (In accordance with the Medical Devices Directive 93/42/EEC) The BodyGuard Infusion System is designed to be in compliance with EN 60601-1 (safety) and IEC 601-1-2 (EMC) Non operating conditions (transportation and storage): -25 C to +50 C (-13 F to +122 F) 5% to 100% R.H., non-condensing 48kPa to 110kPa The system may not meet all performance specifications if operated outside of the following conditions: +15 C to +40 C (+59 F to +104 F) 20% to 90% R.H. at +40 C, non-condensing 70kPa to 110kPa

CME Medical UK Limited Kincraig Business Park Kincraig Road Blackpool FY2 0PJ Tel: 01253 206700 Fax: 01253 896648 Email: customersupport@cmemedical.co.uk cmemedical.co.uk Say hello! Ref: MD001