General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

Chapter 22 Testing Protocols

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

TABLE OF CONTENTS LIST OF FIGURES

ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007

vj.i GUIDELINES --.- PETROLEUM (EXPLORATION & PRODUCTION) (MEASUREMENT) REGULATIONS, 2016 (L.I. 2246)

Operational Settings:

Flow Vision I MX Gas Blending Station

ISO INTERNATIONAL STANDARD. Natural gas Calculation of compression factor Part 2: Calculation using molar-composition analysis

ISO INTERNATIONAL STANDARD

Gas Measurement Fundamentals Certification. Curriculum

Injection Controller Program User Manual (for FloBoss 107 and ROC800-Series)

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

IT STARTS AT THE SOURCE - RE-CALIBRATING YOUR PLANT METERS

Measurement & Analytics Wet gas monitoring

Gas Billing Factors Guideline

Products Solutions Services. Gas Flow Measurement

ISO INTERNATIONAL STANDARD

1 PIPESYS Application

ERZ 2000-NG Flow Computer

GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK

Features. Description

Part 6: Critical flow orifices

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

ISO 2503 INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Agilent 490 Micro GC Natural Gas Analyzer

This document is a preview generated by EVS

* William A. Sala, Jr. John A. Roscher. Columbia Gas Transmission, LLC * Sorana Linder 700 Louisiana Street, Suite 700 Director, Regulated Services

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

analytical bulk flow distance FLOW level pressure temperature industrial communication

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

ISO INTERNATIONAL STANDARD. Flow-metering devices for connection to terminal units of medical gas pipeline systems

ISO 6570 INTERNATIONAL STANDARD. Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods

Discovery HP-TGA 75/750. Site Preparation Guide

GAS CONTRACTS MEASUREMENT LANGUAGE AND ITS EVOLUTION. Lohit Datta-Barua, Ph. D. Enterprise Products

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA

The ERCB Directive 017 Overview

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

Mass Flow Controller (MFC) for Gases

HEALTH AND SAFETY PROGRAM 201 HOT TAP PERMIT/FILLET WELD REPAIRS

Vehicle- or rack-mounted liquefied gas meters, pump supplied

ISO INTERNATIONAL STANDARD. Welding consumables Gases and gas mixtures for fusion welding and allied processes

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Flowatch Multiphase Flow Meter

Calibrating and Monitoring MUSMs in Natural Gas Service

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Slam Shut Valves SCN

Automatically or individually calculated.

ISO 9539 INTERNATIONAL STANDARD. Gas welding equipment Materials for equipment used in gas welding, cutting and allied processes

Yokogawa Systems and PCI Training

Norval Pressure regulator

ISO INTERNATIONAL STANDARD. Transportable gas cylinders Inspection and maintenance of cylinder valves

Software Applications

Technical Bulletin, Communicating with Gas Chromatographs

CAMASS. Calibration Centre. Gas flow technology and services

IE011: Process Control & Instrumentation Technology

UNIT 10 - GASES. Notes & Worksheets - Honors

molbox1+ Flow Terminal ± % of reading lowest uncertainty for gas flow calibration

North American Orifice Metering System

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Micro Motion Advanced Phase Measurement

Thermal flow sensor TA Di with integrated transducer for measuring mass flow, standard flow rate and air / gas consumption

CONVAL HISTORY 07/09/2012

CAMASS. Calibration Centre. Gas flow technology and services

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

PROCESS MONITORING AND CONTROL

IE068: Process Instrumentation Technology

Ultra High Purity Model 780S

Radar, Ultrasonic and RF Level Transmitters

IE039: Practical Process Instrumentation & Automatic Control

VERIFYING GAS CHROMATOGRAPH OPERATION AT CUSTODY TRANSFER LOCATIONS Murray Fraser Daniel Measurement & Control

780S Ultra High Purity Series

Differential Pressure Level Solutions. Bulletin 01C25A04-01EN-Y

ISO INTERNATIONAL STANDARD

ACCESSORY KIT INSTALLATION INSTRUCTIONS

MATHESON s LaserPro Gases and Gas Delivery Equipment

Chemistry 51 Chapter 7 PROPERTIES OF GASES. Gases are the least dense and most mobile of the three phases of matter.

SOFTWARE APPLICATIONS DETAILS. Abstract This document is the calculation details for working with KELTON Standard Calculation Package (FLOCALC.

Software Applications

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Technical Data Sheet MF010-O-LC

The University of Hong Kong Department of Physics Experimental Physics Laboratory

Technical Information

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

ISO INTERNATIONAL STANDARD

Dräger X-dock Frequently Asked Questions

OVERVIEW OF THE CONVAL 10 SERVICE RELEASES

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Transcription:

General Specifications GS 34P02P31-02E Gas Flow Calculation Portfolio (FCN-RTU) GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN-RTU low power autonomous controllers. Using this portfolio, gas flow rate is calculated on robust and hazardous certified STARDOM controllers FCN-RTU while control logics are running. Notation in this document: The term FCN refers to the module consisting type autonomous controllers. The term FCN-RTU refers to the low power autonomous controllers with NFCP050 CPU module. For FCN-500, see Gas Flow Calculation Portfolio (FCN-500), GS 34P02P32-01E. FEATURES High Speed and Volume Calculation 32bit high speed processor achieves a number of flow meter runs for many gas wells and responds to quick change of gas composition. Control with Flow Calculation Control logics, programmed with IEC 61131-3, run with gas flow calculation. Regulatory control function blocks NPAS based on Yokogawa DCS expertise are adaptable for gas flow control such as valve control. (*1) Parameter Setting Window Parameter Setting Window is prepared for easier parameters setting. Via OPC server, parameters can be set to SCADA as well. Meet the requirement of API21.1 Gas Flow Calculation Portfolio meets the requirement of API21.1. *1: To use NPAS function blocks, PAS portfolio license is required. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5616 URL: http://www.stardom.biz GS 34P02P31-02E Copyright Apr. 2016(YK) 1st Edition Jul. 15, 2016(YK)

2 PORTFOLIO COMPONENTS Gas flow calculation portfolio consists of several components. Gas Flow Calculation POU Gas flow calculation POU calculates the gas flow rate and provides the functions meeting to the API21.1 requirement. Gas flow calculation Averaging Data Hourly and Daily Quantity Record Creation Configuration Log Generation Parameter Setting Window can be set to POU and the calculated gas flows are monitored on Web-based parameter setting windows. Those windows do not require any PC based software apart from a web browser. (*1) Parameter Setting on SCADA can be set to POU on SCADA. The variables lists are shown on PARAMETERS SETTING AND MONITORING WINDOW. Logging Logging Portfolio logs the quantity transaction record created by Gas Flow Calculation POU (*2) and alarms and messages. SCADA Parameter Setting Window COTS PC Logging Offline Report file read Report and Event Parameter Set Read Record OPC DA Communication Parameter Set Read Record HTTP Online Report file re ad Automatic File Transfer Tool Process Data FCN-RTU Gas Composition Valve Control Gas Flow Calculation POU IEC Application Process Data Qua ntity Transaction Record Logging Report and Event Pressure Transmitter Gas Chromatography Valve Gas Flow Calculation POU F01E.ai *1: Parameter Setting Windows are included in Application Portfolio Software Media. FCN/FCJ Basic Software License for Single CPU with Java function is required to use parameter setting windows. Parameter Setting Windows use InfoWell technologies. If modification of the parameter setting windows is required, Web Application Portfolio License (InfoWell) is required. TI34P03A51-01E (Gas Flow Calculation Portfolio) describes the modification methods. *2: Logging Portfolio is included in Application Portfolio Software Media. Logging Portfolio license is bundled with Gas Flow Calculation Portfolio. FCN/FCJ Basic Software License for Single CPU with Java function is required to use Logging Portfolio.

3 GAS FLOW CALCULATION POU Gas flow calculation POU calculates the gas flow and creates the quantity transaction record. Gas Flow Calculation Gas flow calculation POU calculates gas flow following AGA publication. Table Supported Gas Calculation Report Number Title Remark AGA Report No. 3 Orifice Metering of Natural Gas Part 3: Natural Gas Applications (1992) AGA Report No. 7 Measurement of Natural Gas by Turbine Meters (1996) AGA Report No. 8 Compressibility Factor of Natural Gas and Related Hydrocarbon Gases (1992) AGA Report No. 9 Measurement of Gas by Multipath Ultrasonic Meters (2007) Pulse input only AGA Report No. 10 Speed of Sound in Natural Gas and Other Related Hydrocarbon Gases (2003) AGA Report No. 11 GPA 2172 Measurement of Natural Gas by Coriolis Meter Calculation of Gross Heating Value, Relative Density and Compressibility Factor for Natural Gas Mixtures from Compositional Analysis (1996) Dry only V-Cone V-Cone (2006) ISO 5167-3 ISO 5167-4 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full -- Part 3: Nozzles and Venturi nozzles (2003) Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full -- Part 4: Venturi tubes (2003) Venturi nozzles only Averaging Data The following two averaging method are supported. Flow-dependent time-weighted linear average (*1) Flow weighted linear average *1: Average is calculated using production time. Hourly and Daily Quantity Transaction Record Creation Gas flow calculation POUs calculate the following value Table Calculated quantity record Time Category Calculated Value Today, yesterday, current hour, previous hour Average Total Static pressure, differential pressure, temperature, flow rate, mass flow rate, energy Total flow, total mass, total uncorrected flow, total energy, total flow time, total shutin time, total pulse Current month Total Total flow Configuration Log When the configuration parameters are changed, Gas Flow Calculation POUs notify the configuration change by setting the configuration flag ON. Generation Process HH/LL/HI/LO messages are generated when process input (Static Pressure, Differential Pressure and Temperature) exceeds the specified limitations. Scan Period of Task and Maximum POU number Table Scan Period of Task and Maximum POU number Item Scan Period of Task Specification Limited to 1 second when using Gas Flow Calculation POU Maximum POU number 8 POUs for FCN-RTU when using logging portfolio (*1) *1: The metering numbers are depending on the total CPU performance.

4 PARAMETERS SETTING AND MONITORING WINDOW The following parameters can be set on Web-based windows (available in sample HTML) or SCADA. Table Setting (1/2) Common Flow Conditions Base Conditions Heating Value Compressibility Gas Composition Orifice V-Cone Meter name Contract hour Meter type Unit Unit Switch Static pressure Atmospheric pressure Base temperature Base pressure Heating Value calculation method Compressibility Gas composition input Normalize Gas composition Relative density Gross heating value for gross heating value for relative density Reference pressure for relative density for molar density Reference pressure for molar density Differential pressure cutoff Orifice Plate Pipe Tap location Correction factor Differential pressure cutoff V-Cone Pipe Correction Factor Meter identifier (Meter Name) Report file closing time Orifice / Turbine / Ultrasonic (Pulse input only) /Coriolis US / SI unit Switch changing unit volume Absolute / Gauge Calculated / Manual Atmospheric pressure is calculated based on Latitude and Altitude in case of Calculated. Base temperature Base pressure Manual / GPA 2172 Heating value is calculated on condition that base temperature is equal 60degF in case of GPA2172. AGA 8 Detail Characterization Method / Gross Characterization Method 1 / Gross Characterization Method 2 Manual / Live Gas composition is set manually in case of Manual. Gas composition is set to POU inputs in case of Live. Yes / No Each gas composition is normalized if total mole fraction is not equal to 1 in case of Yes. Nitrogen, Carbon dioxide, Hydrogen sulfide, Methane, Ethane, Propane, i_butane, n_ Butane, i_pentane, n_pentane, n_hexane, n_heptane, n_octane, n_nonane, n_decane, Water, Oxygen, Carbon monoxide, Helium, Argon Calculated / Fixed Relative density calculated based on the gas composition incase of Calculated. Relative density can be set manually in case of Fixed. Gross heating value can be set manually. Gross method reference temperature for gross heating value Gross method reference temperature for relative density Gross method reference pressure for relative density Gross method reference temperature for molar density Gross method reference pressure for molar density Differential pressure cutoff Bore, material Internal, material for plate and pipe Upstream / Downstream Flow rate correction factor Differential pressure cutoff V-Cone, material Pipe internal, material Flow rate correction factor

5 Table Setting (2/2) Turbine Ultrasonic Coriolis Calculation condition Average Maintenance Venturi nozzle Venturi tube K-Factor Pulse Cutoff K-Factor Pulse Cutoff K-Factor Pulse Cutoff Deadband Average method Mode DP Cutoff Venturi nozzle throat Upstream pipe Tap location Correction Factor DP Cutoff Venturi tube throat Tube type selection Upstream pipe Tap location Correction Factor Pulse K-Factor Pulse cutoff Pulse K-Factor Pulse cutoff Pulse K-Factor Pulse cutoff Gas flow is calculated when process input exceeds the specified deadband. Deadband of static pressure, differential pressure and temperature deadband can be specified. HH/HI/LL/LO limits of static pressure, differential pressure and temperature can be specified. s are generated when process inputs exceed limits. Flow-dependent time-weighted linear / Flow-weighted linear Average method can be selected for static pressure, differential pressure, temperature and pulse count. The specified data is used instead of process data when maintenance mode is set. Maintenance mode of static pressure, differential pressure and temperature can be set. DP Cutoff (US:inH2O, SI:kPa) Venturi nozzle throat (US:in, SI:mm) Upstream pipe (US:in, SI:mm) Tap location (1:Upstream, 2:Downstream) (US:lbm/(ft*sec), SI:cP) Factor for adjusting to the real flow rate DP Cutoff (US:inH2O, SI:kPa) Venturi tube throat (US:in, SI:mm) Tube type selection (1:Cast, 2:Machined, 3:Rough welded) Upstream pipe (US:in, SI:mm) Tap location (1:Upstream, 2:Downstream) (US:lbm/(ft*sec), SI:cP) Factor for adjusting to the real flow rate Table Monitoring Current data Average Total Time Process input Calculation status Calculated data Data item Time span Data item Time span Data item Time span Static pressure, differential pressure and temperature Calculation status Flow rate, raw flow rate (uncorrected flow), mass flow rate(coriolis only) energy, compressibility, compressibility at base condition, super compressibility, ideal relative density, ideal heating value, real heating value, Speed of sound (Ultrasonic only) Static pressure, differential pressure, temperature, flow rate, mass flow rate(coriolis only) Today, yesterday, previous hour Flow rate, energy Today, yesterday, previous hour Production time, shut-in time Today, yesterday, previous hour

6 LOGGING Quantity Transaction Record Logging Quantity transaction records are logged on the controllers using Logging portfolio (*1) File Format File Type File Closing Timing Default Hourly Quantity Transaction Record Table Default Logging CSV File Hourly quantity transaction record file Daily quantity transaction record file Contract hour or configuration change date, time, specified data items *1: Please refer to GS 34P02P51-02E InfoWell for the details of logging portfolio specifications. and Message Logging The alarms and events are logged in the controllers using Logging portfolio (*1) File Format File Type logging file Event logging file CSV File Table Default Logging Process alarm, system alarm Audit trail (configuration change) User event, event message *1: Please refer to GS 34P02P51-02E InfoWell for the details of logging portfolio specifications. OPERATING ENVIRONMENT Low Power Autonomous Controller FCN-RTU Table Hardware Model (CPU) Style (CPU) Hardware NFCP050 S1 or later Table Software Software Basic Software Revision License FCN/FCJ Basic Software R4.02.01 or later For FCN-RTU, the licenses are bundled with CPU module (Model: NFCP050). Select CPU modules with the portfolio licenses required. PC for Configuration Operating environment of the PC for Parameter Setting Window follows the operating environment described in InfoWell GS (GS 34P02P51-02E). PC for Logging follows the operating environment described in Logging Portfolio GS (GS 34P02P51-02E).

7 STYLE OF SOFTWARE SUPPLY Media Programs and Help for Gas Flow Calculation Portfolio are supplied with FCN/FCJ Application Portfolio Media. Gas Flow Calculation Portfolio License Low Power Autonomous Controller FCN-RTU For FCN-RTU, the licenses are bundled with CPU module (Model: NFCP050). Select CPU modules with the Gas Flow Calculation Portfolio License required. Note: To use Parameter Setting windows and Logging Portfolio, FCN/FCJ Basic Software License for Single CPU with Java function is required. Logging Portfolio license is bundled with Gas Flow Calculation Portfolio. If modification of the parameter setting windows is required, Web Application Portfolio License (InfoWell) is required. Web Application Portfolio License (InfoWell) can not be added FCN-RTU NFCP050-S0 ORDERING INFORMATIONS For the type of software media supplied, refer to the separate GS, Application Portfolios(FCN-500/FCN-RTU) (GS 34P02P20-02E). RELATED DOCUMENTS GS 34P02P51-02E TI 34P03A51-01E InfoWell(FCN-RTU) Gas Flow Calculation Portfolio TRADEMARKS STARDOM is a trademark of Yokogawa Electric Corporation. Java is registered trademark of Oracle and/or its affiliates. Other company and product names appearing this document are trademarks or registered trademarks of their respective holders. Subject to change without notice. GS 34P02P31-02E Jul/ 15, 2016-00