PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

Similar documents
EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

Design Requirements for Eyewash and Safety Shower Units

Emergency Shower & Eyewash. Training Guide

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

EYE WASH STATIONS & SAFETY SHOWERS GUIDELINES

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

ANSI Z Compliance Checklist

EMERGENCY EYEWASH & SHOWERS

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance

ANSI / ISEA Z Compliance Checklist

ANSI / ISEA Z Compliance Checklist

Emergency Eyewash & Shower Testing Program

Laboratory Safety Guideline Emergency Eyewash and Safety Showers

Environmental Health & Safety Policy & Procedure #35

EMERGENCY EYEWASH STATIONS & SAFETY SHOWERS GUIDELINES

URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA

ENVIRONMENTAL HEALTH AND SAFETY STANDARD OPERATING PROCEDURES

Installation and Use Manual

UltRo Dual Flow Reverse Osmosis Water System

self closing tapware and bubblers AUTOMATIC SHUT-OFF REDUCE WATER WASTE IMPROVE HYGIENE VANDAL RESISTANT Spring Action Series Time Flow Series

EMERGENCY EYEWASH & SHOWER STATION TRAINING AND MAINTENANCE REQUIREMENTS

Cal Poly Eye Wash and Safety Shower Inspection Program June 20, 2018

Installation. S19-300T (top supply) S19-300B (bottom supply)

Model Portable Eyewash

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

Aquor House Hydrant V2

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Related Products: Auto Drain Valve. Model/Specifications. Model

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

TECHNICAL DATA CAUTION

DS05C,D,G Dial Set Pressure Regulating Valves

GREIG FILTERS, INC. OPERATION MANUAL

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

1020 Industrial Drive, Orlinda, TN fax

Operation Manual Piston Sensed Gas Pressure Regulators

Bar valve with fixed shower head Installation guide

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

INSTALLATION INSTRUCTIONS

Constant Pressure Crude Oil Container Model CPCCP

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Installation Instructions

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

VERTICAL BLADDER TANK

DS06D,G Dial Set Pressure Regulating Valve

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

Halsey Taylor Owners Manual

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Installation/Care/Use Manual

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

3/8" Dr. Air Butterfly Impact Wrench

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

PRO SINK -R 1 and 2. Dilution system CONTENTS

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Halsey Taylor Owners Manual

Bermad Pressure Reducing. Model: 42T

TECHNICAL DATA. Page 1 of 12

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

APPS-160 Gen 2 User Manual

Installation Instructions

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Pressure Independent Control Series

Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

PAGE (Rev. A - 06/17)

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

D05 Pressure Regulating Valves

ASSE International Product (Seal) Listing Program

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Anti-flood device Model B-1

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

V43 Pressure Actuated Water Regulating Valve

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

// ADapters GUIDelines

Engineering Data Sheet

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

WEATHERIZING INSTRUCTIONS

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

TECHNICAL DATA CAUTION

Transcription:

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH Installation, Operating & Maintenance Instructions EEE180 EEE210 EFE360 EFE390 ENBE180 ENBE210 ENBE360 ENBE390 I00011_Apr 18 NOTE: THIS DOCUMENT IS TO BE LEFT ONSITE WITH FACILITY MANAGER AFTER INSTALLATION Call 1300 369 273 www.enware.com.au Enware Australia Pty Limited 9 Endeavour Rd Caringbah NSW 2229 Australia Ph: +61 2 8556 4000 info@enware.com.au

product descriptions EEE180 FREE STANDING EYE WASH HAND OPERATED STAINLESS STEEL EEE210 FREE STANDING EYE WASH HAND/FOOT OPERATED STAINLESS STEEL EFE360 FREE STANDING EYE FACE WASH HAND OPERATED STAINLESS STEEL EFE390 FREE STANDING EYE FACE WASH HAND/FOOT OPERATED STAINLESS STEEL ENBE180 PEDESTAL MOUNTED HAND OPERATED EYE WASH - NO BOWL ENBE210 PEDESTAL MOUNTED HAND/FOOT OPERATED EYE WASH - NO BOWL ENBE360 PEDESTAL MOUNTED EMERGENCY HAND OPERATED EYE/FACE WASH - NO BOWL ENBE390 PEDESTAL MOUNTED EMERGENCY HAND/FOOT OPERATED EYE/FACE WASH NO BOWL

technical information Inlet Connection Water Supply Line Size Minimum Requirements to achieve ANSI Z358.1-2009 and AS/NZS 4775 2007 compliance Enware Performance Waste Water Outlet Size 15mm (½ ) BSP Supply piping shall be adequately sized to meet flow requirements Min Working Pressure: 210 kpa (30 psi) Caution should be taken when pressure exceeds 550 kpa (80 psi) Eye Wash Minimum Flow 1.5 lpm (0.4 US gpm) Eye/Face Wash Minimum Flow 11.4 lpm (3 US gpm) Minimum Working Pressure: 210 kpa (30 psi) Eye Wash Minimum Flow 17 lpm (4.5 US gpm) Eye/Face Wash Minimum Flow 26 lpm (6.9 US gpm) 38.1 mm (1½ ) OD Mounting Base Plate Size 150 x 150 mm (5 9/10 x 5 9/10 ) with 4 bolts 11 mm (7/16 ) Shipping Approximate Weight: 7-8 kilograms Dimensions: 1150 x 287.5 x 200 mm www.enware.com.au Call 1300 369 27 3

installation compliance Installation of emergency showers, eye and eye/face wash equipment shall be in accordance with AS/NZS4775-2007 or ANSI Standard Z358.1-2009 - whichever is applicable to the installation. REFER to checksheet on pages 9 and 10. Supply Lines Installation procedures shall be in accordance with proper plumbing practices. Supply piping shall be adequately sized to meet flow requirements. If shut off valves are installed for maintenance purposes, provisions shall be made to prevent unauthorised shut off. Placement of Emergency Equipment Emergency eyewash and shower equipment shall be available for immediate use. It shall take no longer than 10 seconds for an individual to reach the nearest facility. Factors that influence the location of emergency facilities include workplace lighting, obstructions to the path of travel and the work environment. It should be noted that some situations may warrant the placement of equipment significantly closer to the hazard. In these situations, such as exposure to highly corrosive chemicals, the proper distances should be selected based on the advice from appropriate consultants. For situations such as exposure to strong acids or alkalis, due consideration needs to be given to possible reaction between the flushing fluid and the chemical if the flushing fluid enters a bulk container of the chemical. Flushing Fluid Temperature Continuous and timely irrigation of affected tissues for the recommended irrigation period are the principal factors in providing first aid treatment. Providing flushing fluid at temperatures conducive to use for the recommended irrigation period is considered an integral part of providing suitable facilities. Medical recommendations suggest a flushing fluid at tepid temperature be delivered to affected chemically-injured tissue. Temperatures in excess of 38ºC have proven to be harmful to the eyes and can enhance chemical interaction with the eyes and skin. During design and installation, the effects of exposure of pipe to sun, radiant heat or other heat sources should be considered, and suitable control measures should be introduced to avoid any risk of scalding. While cold flushing fluid temperature provide immediate cooling after chemical contact, prolonged exposure to cold fluids affects the ability to maintain adequate body temperature and can result in the premature cessation of first aid treatment. Before emergency eyewash and shower equipment is selected, a risk assessment shall be carried out to determine the most appropriate delivery temperature for the application. Means to ensure a constantly suitable delivery temperature shall also be identified during selection, so that equipment can perform as desired once installed. ANSI Z358.1:2014 Lic SMKP20545 SAI Global AS4775-2007 Lic. SMKP21998 SAI Global 4 Call 1300 369 273 www.enware.com.au

components EEE210 EEE180 EFE390 EFE360 ENBE180 ENBE390 7A 7B 6 6B 6A 2 2 9 8 5 8 7 5 4 1 3 4 1 3 # Description 1 EEE Base Frame Assembly Base 2 Eyewash Inlet & Waste 3 Assembly Cable* 4 Foot Pedal* 5 Washer 6 Bowl - new style 7A Eyewash Outlet 7B Eye/Face Wash Outlet 8 Anti-vandal Aerator Key 9 Inspection tag * EEE210 and EFE390 only # Description 1 EEE Base Frame Assembly 2 Eyewash Inlet & Waste 3 Assembly Cable * 4 Foot Pedal * 5 Washer 6A Eye Face Wash Outlet 6B Eye Wash Outlet 7 Anti-vandal Aerator Key 8 Inspection tag * ENBE390 only www.enware.com.au Call 1300 369 27 5

installation procedure 1. Place the unit so there is enough space for any additional plumbing fixtures being used (drain, taps, strainers, shut-off valves. Bolt base of Lower Shower Assembly to a level floor using 4 corrosion resistant anchors (refer to AS/NZS 2982.1, ANSI Z358.1-2009 and AS/NZS4775-2007). Base Plate is 150mm² with mounting holes at 100mm centres. SEE IMAGE 1. 25 100 TYP 150mm 100 TYP 11.1 TYP - CLIENT TO SUPPLY BOLTS TO SUIT IMAGE 1 25 2. Attach the Eye (Eye/Face) wash push handle to the Activation Ball Valve using the spring washer and hexagonal nut already on the ball valve. SEE IMAGE 2 Eye Wash Push Handle Waste Adaptor Activation Ball Valve IMAGE 2 Hex Nut Spring Washer 2x Washers 3. If a bowl is to be included with the Eye (Eye/Face) wash, place the Bowl on top of the Waste Adaptor. Using the Washer and the Waste screw in to the Waste Adaptor to secure the bowl. Turn as tight as you can with fingers, then turn Waste and Bowl together using the outside edge of the bowl for extra leverage. SEE IMAGE 3 Waste Washer Bowl Waste Adaptor IMAGE 3 4. Remove the grub screw from the front of the waste adaptor. Push the eye (eye/face) wash assembly into the centre of the waste adaptor making sure the directional arrow is facing the front. Re-fit the grub screw and tighten until it locates within the eye wash frame. SEE IMAGE 4 IMAGE 4 5. Connect the ½ water supply line to the ½ nipple located on the eye wash inlet. Use thread tape or Loctite 577 on all threads. 6. Connect the drain line (if applicable) for the Eye (Eye/Face) Wash Sink using the 1½ OD outlet located on the Base Frame Assembly. There should be sufficient clearance for the addition of a drain trap if required. 6 Call 1300 369 273 www.enware.com.au

7. (For Foot-Operated Models Only) Back off the two rear shower mounting bolts. Slide the bracket under the washers of the shower mounting bolts and retighten. Reattach foot pedal plate to bracket using bolts supplied. Do not over tighten. SEE IMAGE 5 Attach cable to push handle and set the cable length. To do this, turn the push handle to the full on position and lower the foot pedal to approximately 3mm from the ground. Loosen the locking nut using the 4mm Allen key, pull excess cable through and re-tighten nut. Return push handle to the off position. SEE IMAGE 6 IMAGE 5 Foot pedal adjustment 8. Before turning on the water supply to the unit make sure both the shower and Eye (Eye/Face) wash valves are closed. Push up the shower pull rod so the valve arm is pointing back up and pull forward the Eye (Eye/Face) wash PUSH handle back up to ensure the valves are in the closed position. 9. Turn water supply on. Check for leaks before proceeding. Split ring 10. Slowly push the Eye (Eye/Face) wash valve handle forward to start the water flow. IMAGE 6 Flush until the water runs clean then pull back on the push handle to stop flow. Replace aerator assemblies. Remove internal strainer by unscrewing the strainer cap with a flat head screw driver. Clean strainer and re fit. 11. With the aerators reinstalled, use a flat screwdriver to turn off the Ball Valve before Eye (Eye/Face) Wash Activation Ball Valve. Turn the push handle to the full open position and adjust the second ball valve with screwdriver until the correct flow is achieved. SEE IMAGE 7 and 8. 83 32 Required coverage widths Point of fluid stream interaction 38 max 12. To activate the shower, pull down on the triangular pull rod. A large amount of water will flow from the showerhead on to the floor. The spray pattern should be 508mm in diameter at a height of 1524mm from the floor. The shower should also deliver at a minimum flow rate of 75.7 lpm. IMAGE 7 Fluid stream Fluid stream 13. Once correct operation has been checked, turn off the valves by positioning the handles to the fully off position. Note: Water will drain through the 2mm hole near the shower head/ball valve connection. This is a self-draining feature designed to drain water remaining in shower head to reduce Legionella risk. Place dust covers over Eye (Eye/Face) wash outlets. Mount appropriate Shower and Eye (Eye/Face) wash signage as required - refer to Enware s Product guide or call Enware Customer Service on 1300 369 279. IMAGE 8 www.enware.com.au Call 1300 369 27 7

operating and training instructions Instructions for all emergency equipment shall be readily accessible to maintenance and training personnel. Employees who may be exposed to hazardous materials shall be instructed in the location and proper use of emergency shower equipment. Refer to AS/NZS 4775 or ANSI Z358.1 where applicable. EYE, EYE/FACE WASH OPERATION The Eye, Eye/Face wash is activated by pushing forward (away from the user) the flat push handle. This opens the ½ ball valve allowing water to flow to the Eye, Eye/Face wash outlets. To close the valve and stop flow gently pull the PUSH handle back (towards the user). FOOT PEDAL OPERATION (EEE210, EFE390, ENBE390, ENBE210) The Eye, Eye/Face wash can be activated by pushing down the foot pedal where marked. This opens the ½ ball valve allowing water to flow to the Eye, Eye/Face wash outlets. To close the valve and stop flow gently pull the PUSH handle back (towards the user). Releasing the foot pedal will not stop the flow. maintenance The unit should be activated every week for a period long enough to verify operation and ensure the flushing fluid is available. Note: the intent is to ensure that there is a flushing fluid supply at the head of the device and to clear the supply line of any sediment buildup that could prevent fluid from being delivered to the head of the device and to minimise microbial contamination due to sitting water. All eye, eye/face washes shall be inspected annually by a qualified technician to assure conformance with ANSI Z358.1-2009 or AS/NZS 4775-2007 whichever is applicable to the installation. 8 Call 1300 369 273 www.enware.com.au

AS4775 2007 Safety Equipment Minimum Performance Checklist Installation shall be in accordance with proper plumbing practices. Supply piping shall be adequately sized to meet flow requirements. (Sec D1) All plumbed emergency equipment shall be connected to a continuous source of flushing fluid supply which may be drinking water, preserved water, preserved buffered saline solution or other medically acceptable solution manufacturedacceptable solution manufactured and labelled in accordance with applicable government regaulations. (Sec 4.4, 4.10, 6.7 (c)), 7.5 (b), 8.5 (b), 9.5 (b), 11.3.3 (c)) All equipment shall be constructed of corrosion resistant materials (Sec 4.2, 5.1) Note: The Plumbing Code of Australia does not allow the use of galvanised pipes or fittings on drinking water supply lines. AS/NZS3500.1 Sec 2.4.2(c) Safety equipment shall be accessible within 10 seconds of hazard. (Sec 6.6, 7.4, 8.4, 9.4) Safety equipment shall be located on the same level as the hazard and the path of travel shall be free of obstructions. (Sec 6.6, 7.4, 8.4, 9.4) Emergency equipment location shall be well illuminated and be identified by a highly visible sign complying with AS1319 visible throughout the area served by the equipment. (Sec 6.6, 7.4, 8.4, 9.4) Employees who may be exposed to hazardous materials shall be trained in the location and proper use of emergency equipment. (6.8, 7.6, 8.6, 9.6). Emergency equipment shall be activated weekly to verify operation (6.8, 7.6, 8.6, 9.6) Emergency equipment shall be inspected annually to ensure conformance with the requirements of AS4775. (Sec 6.8, 7.6, 8.6, 9.6) Drench hoses are considered supplemental equipment to provide immediate flushing to support plumbed and selfcontained equipment but shall not replace them. (Sec 11.1) Drench hoses shall be simple to operate and shall go from closed to fully open in one second or less. The valve shall be corrosion resistant. (Sec 11.3.2) Eye wash equipment shall deliver flushing fluid to both eyes simultaneously at a flow rate not less than 1.5 l/min at 210kPa. The flushing fluid streams should rise to approximately equal heights and should cover the areas between the interior and exterior lines of the test gauge when lowered not more than 38mm below the fluids peak. (Sec 7.1, 9.1 (c), 7.3.1) Eye / face wash equipment shall deliver flushing fluid to the eyes simultaneously at a flow rate not less than 11.4 l/min at 210kPa. The flushing fluid streams should rise to approximately equal heights and should cover the areas between the interior and exterior lines of the test gauge when lowered not more than 38mm below the fluids peak. (Sec 8.1, 8.3, 9.1 (d)) The flushing fluid nozzles of eye and eye/face wash units shall be not less than 838mm and no greater than 1143mm from the surface on which the user stands and 153mm from the wall or nearest obstruction. (Sec7.4, 8.4, 9.1 (c), 9.1 (d)) The eye and eye/face wash operating control valve shall remain open without the use of the operator s hands. The valve shall be simple to operate and go from closed to fully open in one second or less. The valve shall be corrosion resistant. (Sec 7.2, 8.2, 9.1 (c), 9.1 (d)) www.enware.com.au Call 1300 369 27 9

ANSI Z358.1-2009 Safety Equipment Minimum Performance Checklist RECOMMENDED TESTING FLOW PRESSURE IS 30 psi (+.5 psi -.0 psi) Safety equipment shall be accessible within 10 seconds of hazard. (Sec 4.5.2, 5.4.2, 6.4.2, 7.4.2) Safety equipment shall be located on the same level as the hazard and the path of travel shall be free of obstructions. (Sec 4.5.2, 5.4.2, 6.4.2, 7.4.2) All employees subject to exposure to hazardous material should be instructed in the location and proper use of emergency equipment. (Sec 4.6.4, 5.5.4, 6.5.4, 7.5.4) Emergency equipment shall be activated weekly. (Sec. 4.6.2, 5.5.2, 6.5.2, 7.5.2) All shower units shall be inspected annually to assure conformance with ANSI Z358.1. (Sec. 4.6.5, 5.5.5, 6.5.5, 7.5.5) Combination unit components shall be capable of operating simultaneously and shall be positioned so that components may be used simultaneously by the same user. (Sec. 7.3, 7.4.4) All plumbed emergency equipment shall be connected to a continuous source of flushing fluid supply which may be drinking water, preserved water, preserved buffered saline solution or other medically acceptable solution manufactured acceptable solution manufactured and labelled in accordance with applicable government regulations. (Sec 4.4, 4.10, 6.7 (c)), 7.5 (b), 8.5 (b), 9.5 (b), 11.3.3 (c)) Drench hose must deliver a controlled flow of flushing fluid at a velocity low enough to be non-injurious. (Sec. 8.2.1) A drench hose can only be considered an eyewash eye/face wash if it meets performance requirements in Sec. 5 and/or 6. Delivery of tepid flushing fluid.* (Sec. 4.5.6, 5.4.6, 6.4.6, 7.4.5). *Suggested temperature range above 60 F (16 C) and below 100 F (38 C) Valve shall be designed so that the flushing flow remains on without the use of the operator s hands. The valve shall be simple to operate and go from off to on in one second or less and actuator can not be more than 69 inches (173.3cm) from surface floor of user. (Sec. 4.2.7.1) Emergency equipment location shall be well lit and identified with a highly visible sign. (Sec. 4.5.3, 5.4.3, 6.4.3, 7.4.3) Must provide a means of controlled flow to both eyes simultaneously at a velocity low enough to be non-injurious. (Sec. 5.1.1, 6.1.1, 7.1) Eye/face wash equipment must deliver minimum of 3 gallons (11.4L) per minute of water for 15 minutes. (Sec. 6.1.6, 7.1) Eyewash only must deliver minimum of 0.4 gallon (1.5L) per minute for 15 minutes. (Sec. 5.1.6, 7.1) The flushing fluid of an eyewash eye/face wash shall cover the areas between the interior and exterior lines of a gauge at some point less than 8 inches (20.3cm) above the eyewash nozzle. (Sec. 5.1.8, 6.1.8, 7.1) Outlets shall be protected from airborne contaminants. (Sec. 5.1.3, 6.1.3, 7.1) Flushing fluid nozzles should be 33 to 45 inches (83.8cm 114.3cm) from floor and minimum of 6 inches (15.3cm) from wall. (Sec. 5.4.4, 6.4.4, 7.1) Valve shall be designed so that the flushing flow remains on without the use of the operator s hands. The valve shall be simple to operate and go from off to on in one second or less. (Sec. 5.2, 6.2, 7.2) www.enware.com.au Call 1300 369 27 10