USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Similar documents
U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

U S E R M A N U A L CAUTION. Models: 19MFA Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

USER MANUAL. AIR-OXYGEN BLENDER (DISS and NIST Connections) Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS

U S E R M A N U A L. (CGA 870 Connection)

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

USER MANUAL SAVE THESE INSTRUCTIONS. Manuals available on our Website;

U S E R M A N U A L. HELIUM-Oxygen Blender. (DISS and NIST Connections) Model No. PM5400 Series (shown) PM5500 Series SAVE THESE INSTRUCTIONS

USER MANUAL Series (CGA 870 Connections) SAVE THESE INSTRUCTIONS

AND OPERATION INSTRUCTIONS

U S E R M A N U A L PM2200 SERIES SAVE THESE INSTRUCTIONS

Operating and Maintenance Manual. Flowmeter

Yoke Block Instruction Manual

U S E R M A N U A L PM2200 SERIES SAVE THESE INSTRUCTIONS

453 Series Steam Heated Vaporizing Regulator

USER MANUAL Series (Threaded Connections) SAVE THESE INSTRUCTIONS

HomeFill II Oxygen Conserving Cylinder

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Oxygen Dialflow Meter. Instructions for Use

Yoke Block Instruction Manual

TABLE OF CONTENTS. Copyright 2010 Precision Medical, Inc. 10m 11/10 Printed in USA

SAVE THESE INSTRUCTIONS

6 & 8 Bubble Panel Installation Manual

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Instructions for Cleaning & Maintaining Air Compressor

Micro Dial-Flowmeter. Instructions for Use

- GAS REGULATOR - COMPACT STYLE

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Oxygen Dialflow Meter. Instructions for Use

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Dialflow Regulator. Instructions for Use

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Pressure Regulator. Instructions for Use

TactAir PCP Fill Kit/Adapter. Operation Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Operating Manual. Model MP-4R and MP-4RSS MULTI-PAK TM RESCUE AIR CARTS Manual No. PAK013 (Rev 1 January 2001)

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

AIR INLINE METAL SHEAR

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS

92831 TEL: (714) FAX:

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

Domiciliary Oxygen Switch. Instructions for Use

J Air and Water Kit Instructions Part# 02584

Equinox II NITROUS OXIDE / OXYGEN ADMINISTRATION EQUIPMENT 01EQ7000E

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

CS150 CAP STAPLER OWNER S MANUAL

CF-SERIES HIGH FLOW REGULATORS

NTO-200 Operation Manual

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

6 digital caliper with case

Certified ISO 9000 INSTALLATION AND OPERATION INSTRUCTIONS. Before Installing or Operating, Read and Comply with These Instructions

MANUAL: Jumbo Siamese and Jumbo Wye

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y

Pressure Regulators. Instructions for Use

Rev. B. Operating Instructions

D Series Air and Water Kit Part# 02550

User Operation Manual and Safety Instructions

CSA Sample Draw Aspirator Adapter Operator s Manual

Portable Compressed CO 2 Regulator

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Cocoa Patio Pond with Lit Spillway

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

ROPV R40 E Series User Manual

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

FLANGED TWO-PIECE BALL VALVES

Operating Manual CBA Series Cascade Breathing Air Assemblies

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

ALLEGRO INDUSTRIES SERIES 9910 (LP) CONTINUOUS FLOW, SUPPLIED AIR HOOD RESPIRATORS P/N 9910 P/N 9910R P/N 9910D P/N 9910DS P/N 9912D

RK-IR Sample Draw Aspirator Adapter Operator s Manual

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

453 Series Steam Heated Vaporizing Regulator

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

WEATHERIZING INSTRUCTIONS

SERIES L4E & L6E LADDER EXTENSIONS

USER MANUAL. SAVE THESE INSTRUCTIONS (For latest revision, go to

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

1/2 Twin Hammer Composite. Air Impact Wrench ASSEMBLY AND OPERATING INSTRUCTIONS

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

45A, Armthorpe Road, Brampton, Ontario, Canada, L6T 5M4. Made in Canada by O-Two Medical Technologies Inc.

FLANGED TWO-PIECE BALL VALVES

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Transcription:

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician.

RECEIVING / INSPECTION Remove the Precision Medical, Inc. Flow Selector from the packaging and inspect for damage. If there is any damage, DO NOT USE and contact your Provider. Intended Use To direct the Outlet Flow from any standard flowmeter to any one (1) of the Flow Selector s three (3) outlet ports.

READ ALL INSTRUCTIONS BEFORE USING This manual instructs a Professional to install and operate the Flow Selector. This is provided for your safety and to prevent damage to the Flow Selector. If you do not understand this manual, DO NOT USE the Flow Selector and contact your Provider. (Continued on inside)

SAFETY Information - Warnings and Cautions WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. CONSULT ACCOMPANYING DOCUMENTS USE NO OIL

WARNING Always follow ANSI and CGA standards for Medical Gas Products and Flowmeters (E-7) and Oxygen Handling (G-4). DO NOT use oils, greases, organic lubricants or any combustible materials on or near this Flow Selector. DO NOT use near any type of flame or flammable/explosive substances, vapors or atmosphere. DO NOT smoke in an area where oxygen is being administered. ALWAYS rotate and lock the connector body into place before using Flow Selector. ALWAYS confirm prescribed flow before administering to patient and monitor flow on a frequent basis. After activating flowmeter, be sure patient is receiving flow from proper outlet port.

WARNING cont. FLOW IS ONLY DELIVERED to the selected port indicated by the ON arrow. NO FLOW is delivered to the ports indicated by OFF arrows. CAUTION Only personnel instructed and trained in its use should operate this Flow Selector. Be sure all connections are tight and leak free. Only use oxygen safe leak detector to test for leaks. DO NOT autoclave. DO NOT gas sterilize with EtO (Ethylene Oxide). DO NOT clean with aromatic hydrocarbons. DO NOT attempt to repair the Flow Selector. DO NOT immerse the Flow Selector in any kind of liquid. This will void the warranty. Store Flow Selector in a clean area when not in use.

SPECIFICATIONS Model Inlet Connection Bottom Outlet Connection Side Outlet Connection(s) PM1000 9/16-18 Female Thread 9/16-18 Male Thread Hose Barb Type Maximum working pressure: 50 psi (Continued on inside)

Component description Inlet Connection OFF Arrows indicate NO flow through selected port ON Arrow indicates flow direction Outlet Connection Locking Button Outlet Connections

CAUTION Missing or illegible labels must be replaced, contact Precision Medical, Inc. Inspect the Flow Selector for visual damage before use, DO NOT USE if damaged. OPERATING INSTRUCTIONS 1. Be sure flowmeter is in OFF position. 2. Attach functioning flowmeter to an appropriate gas source per flowmeter s manufacturers instructions. 3. Attach the Flow Selector to outlet of flowmeter. 4. Connect up to three (3) medical devices to the outlet ports. 5. Push the Locking Button UP and rotate Connector Body to align the ON indicating arrow with the desired outlet port.

OFF indicating arrows should align with the other two (2) ports not in use. NO FLOW is delivered to the ports indicated by OFF arrows. 6. Release the Locking Button to lock the Connector Body into place. WARNING Read this User Manual before installing or operating the Flow Selector. NO FLOW is delivered to the ports indicated by OFF arrows. NO FLOW between the ON and OFF settings. FLOW IS ONLY DELIVERED to the selected port indicated by the ON arrow. ALWAYS rotate and lock connector body into place before using the Flow Selector.

WARNING cont. After activating flowmeter, be sure patient is receiving flow from proper outlet port. To avoid injury to patient: ALWAYS confirm prescribed flow before administering to patient and monitor flow on a frequent basis. CLEANING / MAINTENANCE 1. Disconnect all connections before cleaning. 2. Clean exterior surfaces of the Flow Selector with a cloth dampened with mild detergent and water. 3. Wipe dry with a clean cloth. CAUTION DO NOT immerse the Flow Selector in any kind of liquid. This will cause damage to the Flow Selector and will void the warranty.

TROUBLESHOOTING If the Flow Selector fails to function, consult the Troubleshooting Guide below. If problem cannot be solved, consult your Provider. Problem No flow at outlet Probable Cause No flow from Flowmeter Outlet port is in OFF position Remedy Turn the Flowmeter ON Align Outlet port with ON arrow Tell us how we are doing! Visit us at www.precisionmedical.com

Returns Returned products require a Returned Goods Authorization (RGA) number, contact Precision Medical, Inc. All returns must be packaged in sealed containers to prevent damage. Precision Medical, Inc. will not be responsible for goods damaged in transit. Refer to Precision Medical, Inc. Return Policy available on the Internet, www.precisionmedical.com. Manuals available on our Website; www.precisionmedical.com Disposal Instructions This device and its packaging contain no hazardous materials. No special precautions need to be taken when disposing the device and/or its packaging. Dispose of the Product in accordance with the local regulations. Please Recycle

LIMITED WARRANTY AND LIMITATION OF LIABILITY Precision Medical, Inc. warrants that the Flow Selector (the Product) will be free of defects in workmanship and/or material for the following periods: One (1) year from shipment Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc. s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable repair or replacement at its own expense. ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES. The representative of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the terms of that contract. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED. Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits, lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical, Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or change product materials, designs, or specifications without notice. Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.

ISO 13485 Certified Precision Medical, Inc. 300 Held Drive Northampton, PA 18067 USA Toll Free Tel: 800-272-7285 Free Fax: 800-352-1240 Tel: (+001) 610-262-6090 Fax: (+001) 610-262-6080 www.precisionmedical.com 502762 Rev8 (E) 022012 (?M) Printed in USA