1800C and 1800C-HC Series Service Regulators

Similar documents
1200B2 Series Service Regulators. Instruction Manual

Regulator from 1800 B series

1800CPB2 Pilot-Loaded Service Regulators

1800C and 1800C-HC Service Regulators

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Model 1800 PFM Series Regulator. Technical Bulletin

SR100 Series Service Regulators. Technical Bulletin

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG

1800CPB2 Service Regulators

American Meter Co. Five-Year Limited Warranty Industrial Regulators

MEGR-1627 Instruction Manual

1800C & 1800C-HC Service Regulators

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

MEGR-1912 Instruction Manual

Types S100K and S102K Pressure Regulators

Series 100 Slam Shut Valve. Technical Bulletin

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

1805 Series Relief Valves

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

2.0 INSTALLATION & SERVICE

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

1305 Series Pressure Reducing Regulators

Types 749B and R130 Changeover Manifolds

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Model 141-A Regulators

Industrial Regulator Series 1800/2000

Combination Air Valve

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

LRS(H)4 Pressure-Reducing Regulator User Manual

WW-730. Pressure Sustaining/Relief Control Valve

R122H, R222, R232A, and R232E Series Instruction Manual

Installation, Operation, and Maintenance Manual

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

CS800 Series Commercial / Industrial Pressure Reducing Regulators

Bermad Pressure Reducing. Model: 42T

TECHNICAL DATA CAUTION

627 Series Pressure Reducing Regulators

Operation Manual Piston Sensed Gas Pressure Regulators

R600 and HSRL Series Instruction Manual

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Type R622 Pressure Reducing Regulator

RD(H)20/25 Pressure-Reducing Regulator User Manual

V DGX Series. Direct-Operated Regulators Manual D103834X012

64 Series Pressure Reducing Regulators

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Types S100C and S102C Pressure

Anti-flood device Model B-1

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Model: 43T. Bermad Pressure Relief Valve

RS(H)20, 25 USER MANUAL

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

PRO-50 Instrument Supply Regulator

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

WW-720. Pressure Reducing Control Valve

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Type CT88 Backpressure Regulator

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

627 Series Pressure Reducing Regulators

Type ACE95jr Tank Blanketing Valve

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

R600 and HSRL Series Instruction Manual

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

OPERATING AND MAINTENANCE MANUAL

Pressure Regulators. Operating Instructions. Instrumentation

Type 299 Pressure Reducing Regulators

Radial Flow Valves. Installation Operation Control Manifold Control Loops Repair Parts. ANSI Class 150, 300 and 600 IM

CL34 Regulator Commercial and Industrial Regulator

299H Series Pressure Reducing Regulators

S300 Series. Valve Link. Features. Fisher Controls

1805 Series Relief Valves

WW-720. Pressure Reducing Control Valve

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

V43 Pressure Actuated Water Regulating Valve

Combination Air Valve Model

WHEATLEY Series 500 Swing Check Valve

Type ACE97 Pad-Depad Valve

TECHNICAL INSTRUCTIONS

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

CL31 Series Commercial Regulator. Advanced Metering and Regulation Technology at Work.

1301 Series High-Pressure Regulators

Types 95L and 95H Pressure Regulators

Model 141-A Field Regulator. R-1311 Rev. 9

299H Series Pressure Reducing Regulators

Hawk Mechanical Alley 111 Submittal Log - Hawk Job #: /21/2014. Submittal Status

553 Series.

Transcription:

1800C and 1800C-HC Series Service Regulators Installation Instructions www.elster-americanmeter.com

General Information: The 1800C and 1800C-HC Regulators are available as Full Capacity Internal Relief Models. Series 1800C and 1800C-HC Regulators are also available with overpressure shut-off protection. Available valve body sizes: /" x /", /" x 1", /" x 1-1/", 1" x 1", 1" x 1-1/", 1-1/" x 1-1/" NPT or BSP-TR. Also available as Offset Valve Body in /" x /", /" x 1", 1" x 1" NPT or BSP-TR. 1800C-HC is available with 1-1/" valve body only. Maximum inlet pressure, normal service (P1): Depending on orifice size, up to 125 PSIG. Maximum outlet set pressure, normal service (P2): Depending on spring selection, up to 2 PSIG (56" W.C.). Orifice Sizes Orifice Size Part Number * Standard w/ OPSO 9/16" 729P026 72751P019 1/2" 729P025 72751P016 /8" 729P02 72751P01 5/16" 729P022 72751P01 1/" 729P021 72751P012 /16" 729P020 72751P011 1/8" x /16" 729P00 72751P020 1/8" 729P019 N/A *See brochure SB-8515 for maximum inlet recommendations and capacity performance for each orifice size. Pressure Springs Outlet Pressure Color Code Part Number Range.5" to 6" W.C. Blue 70017P0.5" to 7.5" W.C. Tan 70017P089 5.5" to 8.5" W.C. Yellow 70017P0 6" to 15" W.C. Purple 70017P02 12" to 28" W.C. White 70017P060 2" to 8" W.C. Red 70017P082 2" W.C. to 2.0 PSIG Red-Red 70017P09 Preparations: Do not connect the inlet of the regulator to a normal pressure source higher than that recommended. Never connect the regulator outlet to the source of pressure. Observe the flow direction arrow on the valve body. If inlet pressure can exceed the maximum regulator outlet pressure rating, some form of overpressure protection in addition to internal relief may be required. To prevent damage to the regulator and possible personal injury, inlet and outlet pressures must not exceed the regulator pressure rating stated on page. 1. Install, operate, inspect and maintain the regulator as outlined in the following instructions and in accordance with your company's policies and applicable federal, state and local codes and laws. Failure to follow these instructions may result in damage to the regulator or personal injury. 2. Check installation location for suitability. It is possible that physical changes have been made to the building site since the regulator and location were originally selected.. Examine regulator for shipping damage.. Check regulator and piping for foreign matter which may have accumulated during shipment or handling. 5. Check seal plug information to determine if regulator is suitable for intended service. 6. Suitable stop valve(s) should be installed and should be conveniently located. 7. Filters are available from American Meter for applications where pipeline contaminant s are suspected to be present. 8. Regulators may be used at temperatures between -20 F and +150 F (-0 C and +65 C). Installation: (Numbers in parentheses refer to figure 1, page.) Warning: Inside Installation: Will require a vent line of sufficient diameter to carry gas vented by the regulator to a safe outside location away from any opening in the building. For all sizes of regulators, a 1-inch NPT or BSP-TR is provided for a vent line. Do not thread a pipe into the vent more than 7 turns so as not to block the vent flapper. Outside Installation: Will require that care be taken to prevent vent opening from freezing closed or becoming blocked or permitting water to enter from any cause. Particular consideration should be given to sites where flooding, snow, or freezing rain may be experienced. The vent or vent line port should point vertically downward and overhead protection should be used where necessary. 1. Remove all shipping plugs. 2. Use good piping practice. Be sure piping and regulators are free of dirt, pipe dope and other debris. Apply pipe dope to male threads only.. Install regulator. Make certain it is piped correctly with inlet pipe connected to the inlet regulator connection and flow is in the direction as indicated by arrow located on valve body (19). The vent should be positioned to prevent entry of water and debris. American Meter recommends that the vent face downward. By removing the two bolts (5), the diaphragm case (8) may be rotated in 90 degree increments in relation to the valve body (19). Replace and tighten the bolts (5). Inside Installations - A regulator installed within a building should be located as near as practical to the point of service line entrance.. Turn gas on slowly. If an outlet stop valve is used, it should be open first. Do not overload the diaphragm with a sudden surge of inlet pressure. 5. Assure that there are no leaks and all connections are tight. 6. The 1800C Series regulator is preset at the factory with the diaphragm in the horizontal position and should not require any adjustment if installed in that position. The outlet pressure may vary as much as 0.5" W.C. if the regulator is installed in the vertical position. Should you decide to adjust the set pressure, perform the following: (a) Turn gas off and depressurize the (b) Install outlet pressure gauge. Remove seal plug (1). (c) Turn gas on slowly. 2

(d) Establish a low flow rate - 5 to 55 SCFH. (e) Turn pressure spring adjustment screw (9) clockwise to increase outlet pressure or counterclockwise to decrease outlet pressure. (f) Establish the set pressure within the range limits of the pressure spring used. (g) To test for the regulator's ability to fully shut off (lockup), shut off all flow downstream of the regulator. At lock-up, the outlet pressure will be somewhat higher than the set pressure. However, if the pressure continues to rise after seconds, the regulator must be repaired. Observe for 0 seconds. (h) When the set pressure has been properly adjusted, depressurize and remove gauge(s) and lines. (i) Replace seal plug (1). (j) Pressurize and check all connections for leaks. Inspection: (Numbers in parentheses refer to figure 1.) Inspection and maintenance of the 1800C and 1800C-HC Series regulator has been simplified for practical reasons. Repair parts are offered if maintenance of the regulator is required. Inspection of the valve seat disc (1) and orifice valve (7) may be performed in the field. Follow the procedure described below. Care should be exercised to prevent foreign matter from entering the regulator. Procedure for Inspection of Valve Seat Disc and Orifice 2. Remove two bolts (5) securing the diaphragm case (8) to the valve body (19) and separate the diaphragm case from the valve body.. Visually check the seating edge of the orifice (7). If it is nicked or damaged, it should be replaced with a new orifice to provide proper shutoff. See Maintenance instructions for replacing the orifice.. Inspect the surface of the valve seat disc (1). If it is scored or uneven replace it as outlined in the Maintenance instructions. 5. Install new seal ring (2) in the diaphragm case groove. 6. Inspect unit for cleanliness and proper positioning of the parts. Pay particular attention to the proper positioning of the seal ring (2) in the groove. 7. Install the diaphragm case (8) on the valve body (19). Make sure the vent is pointed downward. Replace and tighten the valve body bolts (5). 8. Proceed to Steps, 5 and 6 of the installation instructions. Regulators are pressure control mechanisms having numerous moving parts which can wear. In addition, regulator damage may occur from external sources. For these reasons, the regulator should be periodically inspected and checked for proper operation. The frequency of inspection will depend on the severity of the service conditions and the requirements of applicable local, state and federal codes and regulations. Maintenance: (Numbers in parentheses refer to figure 1.) Replacing Seat Disc: 1. Carefully insert the tip of a knife along the edge of the seat disc (1) and lift the seat disc out of the plunger (17). 2. Install a new seat disc (1) into the plunger (17), by pressing into place. Make sure that the disc is pressed completely into the plunger (17).. Proceed to Steps 5, 6, 7 and 8 of the Inspection Instructions. Handling and Disposal "As a knowledgeable user of American Meter s products, we are sure that you are aware that parts in the Company s meters and regulators contain or are coated with heavy metals such as cadmium, zinc, lead and chromium. Obviously, therefore, repair or refurbishment of this equipment should take into account the presence of these materials and should comply with all state and federal requirements concerning worker protection, proper disposal and safety, including protection against exposure to dust and fumes." 7 1 19 17 1 9 6 5 11 16 20 15 2 1 12 10 Figure 1 (181C & 181C-HC Regulator) 8 18 21 22 Item Description Item Description No. No. 1 Disc, Valve Seat 12 Lever 2 Seal Ring, Valve 1 Pin, Lever Body Diaphragm 1 Plug, Seal Screw, Diaphragm 15 Spring, Relief Case Valve 5 Bolt, Valve Body 16 Guide, Valve Plunger 6 Spring, Pressure 17 Plunger, Valve 7 Valve, Orifice 18 Assembly, Top 8 Diaphragm Case 19 Valve, Body 9 Screw, Pressure 20 Plate, Diaphragm Adjustment 10 Stem 21 Screen, Vent 11 Retainer, R.V. Spring 22 Vent Valve

Replacing Orifice: (Numbers in parentheses refer to figure 1, page.) CAUTION: Regulators that have an orifice size change different than shown on the seal plug or tag must have their set pressure reestablished. Mark new orifice size and set pressure on the regulator seal plug or on its tag. 2. Remove two bolts (5) securing the diaphragm case (8) to the valve body (19). Place the diaphragm case aside and protect the seat disc from dirt particles.. Remove the orifice valve (7) with a 7/8" hex socket wrench.. Sparingly apply Henkell G0 or Loctite "Stainless Steel PST" thread sealant or equivalent (not supplied) to the new orifice threads. 5. Carefully start the threads of the orifice into the valve body and tighten to specification. Care must be taken to prevent nicking the orifice. 6. Proceed to Steps 5, 6, 7 and 8 of the Inspection Instructions. Replacing Pressure Spring: (Numbers in parentheses refer to figure 1, page.) Regulators that have a pressure spring removed or replaced must have their set pressure reestablished. If the pressure spring is different from that shown on the seal plug or tag, mark spring range on the regulator seal plug or on its tag, and cross out the old value. 2. Remove seal plug (1).. Unscrew pressure adjusting screw (9) with a /8" screwdriver and remove the pressure adjusting screw completely.. Remove the pressure spring (6). Install new pressure spring. 5. Replace the pressure adjusting screw and turn adjusting screw to about mid position. 6. Proceed to Steps, 5 and 6 in Installation Instructions. Resetting The OPSO: (For 18C and 18C-HC only.) (Numbers in parentheses refer to figure 2.) 2. Unscrew the OPSO lower diaphragm case cap (body plug) (1).. Pull back the knurled plunger (2) until the diaphragm stem () repositions (an audible click).. Replace the OPSO diaphragm case cap (body plug) (1) after examining the o-ring () for damage. 5. Proceed to Steps and 5 in Installation instructions. Figure 2. Regulator Pressure Rating 125 PSIG = Maximum recommended inlet pressure for normal service. Maximum recommended pressure may vary with orifice size. 175 PSIG = Maximum inlet pressure for abnormal or emergency service, without causing damage to regulator case. 2 PSIG = Maximum outlet pressure for normal service. 10 PSIG = Maximum outlet pressure which can be contained by pressure carrying components (no flange leakage to atmosphere except for normal relief action). If regulator is subjected to these conditions, it should be removed from service. 50 PSIG = Maximum outlet pressure for abnormal service without damage to internal components. If regulator is subjected to these conditions, it should be removed from service. Due to continuous development the information in this document is subject to change. 2 1 Operation & Resetting The Jeavons USSA: 1. For USSA operations on models 185C and 185C-HC w/ Jeavons see brochure SB-8556. AMERICAN METER 00 Welsh Road, Building One " Horsham, PA 190-22 " USA " Tel: (215) 80-1800 " Fax: (215) 80-1890 CANADIAN METER 07 Derry Road, West " Milton, Ontario L9T 2X6 " Canada " Tel: (905) 878-261 " Fax: (905) 878-5758 PB/1000/05-02 FP 07-9

About Elster Group Elster Group is the world s leading manufacturer and supplier of highly accurate, high quality, integrated metering and utilization solutions to the gas, electricity and water industries. In addition, through its subsidiary Ipsen International, it is the leading global manufacturer of high level thermochemical treatment equipment. The group has over 8,500 staff, operations in 8 countries and serves over 115 markets around the world. Elster s high quality products and systems reflect the wealth of knowledge and experience gained from over 170 years of dedication to measuring precious resources and energy. Elster American Meter 2221 Industrial Road Nebraska City, NE 6810 USA T +1 02 87 8200 F +1 02 87 7616 www.elster-americanmeter.com 2008 Elster American Meter. All rights reserved Information contained herein is subject to change without notice. Product specifications may change. Contact your Elster American Meter representative for the most current product information. Printed in the United States. EAM-II8720.1-EN-P - January 2008 Supersedes IM 8720.1