EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

Similar documents
The CompacSas BAH airlock is the ideal solution for transforming an existing door into an airlock

CompacSas BA. Comfort and design for high-security access

The elegant solution for enhanced security. Manual Attack Resistance. Ballistic Resistance. Recyclable product. Eco-design. exit

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance

AGW SYSTEMS. Blue Clock W38X

SECURITY AIRLOCK SOLUTIONS

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

AN-140. Protege WX SALLIS Integration Application Note

Surge suppressor To perform its intended functions, an AEI site must have the components listed above and shown in Fig. 4.1.

BUBBLER CONTROL SYSTEM

Connect with Confidence NO POWER NO PROBLEM

HumiSys HF High Flow RH Generator

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

LED Proposal for Basketball Stadium

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Panther 5 Acute Care Ventilator

SVEA II GSM Connector User Manual

Electronic Volume Correctors

SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL

Touch Screen Guide. OG-1500 and OG Part # T011

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

A TECHNICAL REFERENCE

HyperSecureLink V6.0x User Guide

Electronic gas volume corrector model DGVC-04

NEW: CO2 incubator with sterilizable sensor

MP15 Jockey Pump Controller

RESOLUTION MSC.94(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR NIGHT VISION EQUIPMENT FOR HIGH-SPEED CRAFT (HSC)

User manual. PCA EXCEL one4all with corridorfunction PCA T5 ECO lp with corridorfunction TE one4all with corridorfunction

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

IBU3 Manual Addendum 1

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

CO2 incubator with additional process controls

XC2 Client/Server Installation & Configuration

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

NEW: CO2 incubator with sterilizable sensor

BUBBLER CONTROL SYSTEM

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

OMNISPORT 2000 SWIMMING QUICK REFERENCE

Oxygen Meter User Manual

Stand-Alone Bubble Detection System

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

Transmitter CS 21 Operation Manual

WELCOME TO THE REVOLUTION

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

REASONS FOR THE DEVELOPMENT

IST-203 Online DCS Migration Tool. Product presentation

Product Overview. Product Description CHAPTER

Autocalibration Systems for In Situ Oxygen Analyzers

Remote Control Bait Boat

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

Pneumatic high-pressure controller Model CPC7000

MANY REQUIREMENTS - ONE SOLUTION: SCENTY control

Operating instructions Capacitive sensor KIA (M30) / / 2010

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

X-dock Software History

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

User s manual VCI07. For variable speed compressors ed00. Applicable as of Version 12. Bar PSI C F

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

Typical Wayside Reader System Quotation

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

POP Product Guide. [Type text]

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

IPR208D - IPR215D IPR208D - IPR215D GB r docx IPR208D -IPR215D 1/99

GV Standard X-Vent. Setup, Commissioning & Installation Guide

IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications

Description. Measuring Device 3760XBI USP. Balancing

LT GasAnalyzer beyond standards

LENNOX SLP98UHV DIAGNOSTIC CODES

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual

Dräger Mine Refuge Chamber MRC 5000 Innovative, portable life support system

TH-1800-T TRX-700-CNG Converter

CCT-7320/ROC-2313 Reverse Osmosis Controller

CO2 incubator with additional process controls

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Manual Weighingblock VB2 series and Uniscale

Pneumatic high-pressure controller Model CPC7000

SAFE CAPACITY TEST: INNOVATION AND SAVINGS

AHE58/59 AC Servo System

Additel 761 Automated Pressure Calibrators

ADT 761 Automated Pressure Calibrator

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

EASYTOUCH. Because automation makes it all so simple. pentairpool.com

Transmitter CS 21 Operation Manual

WAVE 300 XL. User Instructions

Please note. Right now, the ongoing version of emax (3.9C) is not already completely compatible with the newest firmware version of Shimano!

BUDDY Gorgeous and easy to use GPS Navigation Kit USER GUIDE. Love from Intempo Digital xx

HS653 Negative Pressure Ventilation Controller

SonoMeter 30 Energy Meters

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

PCE-D122 Series. Programming Manual TPM. Version: V N15. To properly use the product, read this manual thoroughly is necessary.

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

Airox Supportair Ventilator

fabian Therapy evolution Our 2-in-1 device

Transcription:

EasySas The most advanced airlock electronics on the market Eco-design Energy savings Recyclable product

ELECTRONIC AIRLOCK MANAGEMENT SkySas range UniSas range CompacSas range An electronic management concept to simplify the onsite implementation of an airlock Gunnebo, as the leading manufacturer of safety airlocks, has developed EasySas as a new concept in electronic airlock management. The EasySas concept is based on electronic management that is both standard and modular in design. Its purpose is to simplify implementation of an airlock on site. Where safety concepts and requirements are concerned, this all-in-one management offers a wide choice of configurations. It allows basic management of up to 5 doors, filtering passages from control consoles, controlling access from keyboards, badge or biometric readers, management of various detection systems (presence, uniqueness and metallic objects), and more. Advantages 1. All-in-one management: centralized and modular. 2. Easy to customize and upgrade. 3. Calculating power of the microcontroller. 4. Simplified activation and maintenance. 5. Native IP. 6. Adjustable alarm contacts.

Architecture The EasySas concept is designed for basic control of up to 5 doors (e.g. double airlock with entry and exit airlock, plus an emergency door). Closed-loop control cabinet with options 1 6 2 EMERGENCY DOOR 3 SAS 1: EXIT SAS 2: ENTRY 5 It is made up 2 distinct parts The management cabinet integrating the GSC management card. This communicates by a single cable connected to each of the doors in series. The airlock s doors are equipped with a GDC door card. This card creates an interface with all of the door s standard equipment. 4 Cabinet equipment 1. An isolation switch for turning cabinet voltage on/off. 2. A 150W backup power supply. 3. A GSC management card. 4. Backup batteries. 5. One or two 8E/S extension cards (optional). 6. Arrester module (optional). ELECTRICAL PROPERTIES Mains voltage Mains frequency Power Backup batteries Operating voltage Operating temperature Relative humidity 110 230 Vac 50 60 Hz 150 W 6.5 Ah 24 Vdc 12 Vdc From 20 C to +70 C < 90% without condensation

ELECTRONIC AIRLOCK MANAGEMENT Operation A safety airlock is mutually used by 3 distinct applications Public access Employee access Moving objects and securities EasySas integrates various standard functionalities that respond to the latest applications. They can be selected using EasyTool configuration software. Free or filtered passage (with a control console) Automatic mode (free entry and exit) Interior door control mode (opening in free entry for D1 and D2 after authorization, free exit) Exterior door control mode (opening in entry after authorization, free exit) Closed mode (entry forbidden, free exit) Controlled mode Exterior airlock control mode (exterior doors opened by airlock through access control) Interior airlock control mode (interior doors opened by airlock through access control) Identified mode (entry opening in D2 by biometric reader) Controlled and identified mode (entry opening of D1 by access control and D2 by biometric reader) Commands Disconnected mode (door loop control suppressed) Free access mode (unlocking of the 2 doors) Blocking mode (D1 unlocked and D2 blocked in the two passage directions) Household mode (D2 stays unlocked) 1st entry mode (personnel entry procedure) Customization Adapting the program to respond to specific client needs. Interface and/or alarm contacts 9 relay exits are available as standard on the GSC card (3 units of supply data and 6 units of functional data) The number of available exits can be increased to 17 (or 25) by adding one or two optional C8E/SR extension cards. The notification of the physical exits must be configured through EasyTool software. Command inputs 6 entries are available as standard on the GSC card The number of available inputs can be increased to 14 by adding an optional C8E/SR extension card The notification of the physical entries must be configured through EasyTool software Control consoles The control console is the MMI (man-machine interface) indispensable for manually managing and filtering passages. Available in two models, with LED display (CBA model) or digital display with a multilingual drop-down menu (PPS model), the control console provides command, visualization and communication functions (intercom option). EasySas management allows connection of up to 2 PPS and 4 CBA models. The PPS console also offers management of user rights through a hierarchical badge system. Intercom The intercom option can be used in combination with a control console to communicate with a person in the airlock. Synthesized voice messaging This allows prerecorded messages in various languages to be broadcast, such as in the event of an alarm. Emergency procedures Unconditional release of the doors equipped with a failsafe lock by external electrical command (breaking glass, fire alarm signal) Power supply The EasySas cabinet can be used with any mains network that provides power of 110-230 Vac 50-60 Hz. An earthed fault protection device (30 ma) must be incorporated into the fixed installation in keeping with local regulations.

INTENSIVE USE Backup batteries Two 12 V, 6.5 Ah batteries, standard. Other backup battery specifications can be defined as needed. For reference, hinged-door airlocks can operate independently on a 6.5 Ah battery as follows: TYPE OF AIRLOCK NORMAL USE INTENSIVE USE 2-door airlock 6 hours 4 hours 4-door airlock 3 hours 2.5 hours Maintenance tools EasyTool software allows the field technician to validate or modify certain functional parameters A micro SD card can store various files for download to the GDC or GSC cards, the PPS console and the vocal synthesizer, along with any technical documentation In addition to loop control management, the card provides these functions Power supply: 12 Vdc / 24 Vdc; battery charge. Fuse protection Intercom Vocal synthesizer Real-time clock (event log/time slots) Technical data for the GDC door card (Gunnebo Door Controller): Technical data for GSC controller card (Gunnebo SAS Controller): Each door is equipped with a GDC door card. It is designed to centralize connection of all the latest door equipment. The card is connected to the central cabinet by a single cable. Equipment connected by bus Wiegand or Dallas ISO2 log readers (bus readers) 2 RS485 connections (EasySas internal bus: GSC card and external bus monitoring consoles) External equipment The controller card is equipped with 3 RS485 connections (EasySas internal bus: GDC cards and consoles, PC bus, and external bus monitoring) 1 I2C connection (optional C8E/SR card) 1 TCP/IP connection (IP connection) 1 micro SD card reader (firmware backup + vocal synthesizer program and messages) 6 relay inputs and 6 relay outputs (external interface with alarm or access control) 3 alarm relay outputs (power supply) 1 extension port 1 metal detector connection 1 lighting or video surveillance connection MTS touch buttons with visualization Electric lock Presence detection by 1-zone contact mat or IR radar Single-person detection using 2-zone mat or UniRitz II Equipment on the GDC card Door contact position (DMO) Configuration switches Function LEDs (visible without removing the card) Intercom: Micro and Loud Speaker Emergency unlocking command

ELECTRONIC AIRLOCK MANAGEMENT Principle Disabled People call

Gunnebo is a leading provider of efficient and innovative security solutions and services to customers around the globe. It employs 5700 people in 32 countries across Europe, Asia, Africa, Australia and the Americas, and has a turnover of 580m. Gunnebo focuses its offering on Bank Security & Cash Handling, Secure Storage, Global Services and Entrance Control. We make your world safer. Design and production: Gunnebo. Photos Credits: Gunnebo and Fotolia. The data given in this material may be subject to change without further notice. The Gunnebo logos and Gunnebo For a safer world are registered trademarks of Gunnebo AB. GUGB.9116.R1