ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

Similar documents
ARCHITECT INSTALLATION GUIDELINES FOR RESIDENTIAL TRITON INSTALLATIONS

ARCHITECTURAL GUIDELINES 1000 S

ARCHITECTURAL GUIDELINES FOUR-PIECE COMMERCIAL

ARCHITECT GUIDELINES 1000 T

ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL

Blue Whale Spa :- Site Preparation and Delivery

D E L U X E S E R I E S. Your Hot Tub Pre-Delivery Guide D E L U X E

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Swim Spa Pre-delivery Guide

Life Smart Spas Frequently Asked Questions

Your Hot Tub Pre-Delivery Guide

PRE-PURCHASE DECISIONS...1 BEFORE DELIVERY...1

Pool Name Length Width Lineal Ft. Gallons Weight $ Price $

Vertex VP Operation and Maintenance

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

SPA WORLD. Pre- delivery Guide

Life Smart Spas Frequently Asked Questions LS600DX

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

You are now the proud new owner of an Alpine Swim Spa!

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

NGP-250/500 Nitrogen Generator Quick Start Guide

Swimming Pool Requirements Packet

Step-by-Step Planning Guide

Ventam 85 Installation & Commissioning Instructions

In Vessel Composter Installation & Commissioning Manual

2018 MODEL. SwimFit / SwimExpert INSTALLATION GUIDE

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

City of Lockport Above Ground Pool Regulations

COATINGS SPRAY GUIDE Urethane 520

AMITY TWP POOL REQUIREMENTS

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Pool / Hot Tub Permit

RESIDENTIAL SWIMMING POOL

City of DuBois PERMIT APPLICATION P. O. Box 408, 16 West Scribner Ave - DuBois, PA Phone: Fax:

Hot Tub Pre-Delivery Guide

COATINGS SPRAY GUIDE Fast Set Urethane 530

Pool Inspection. Your Street San Diego, California Prepared for: Your Name Prepared by: Priority Inspection Service

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

The purpose of this brochure is to explain to owners and contractors the City of Burnaby s requirements for private swimming pools.

Swimming Pool Requirements

Check with local zoning official for property line distance requirements.

Thank you for your enquiry regarding our Western Red Cedar Hot Tubs.

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

2018 MODEL. SwimFit / SwimExpert INSTALLATION GUIDE

HAS2400 Hepa Air Scrubber

Residential Swimming pools

SWIMMING POOL REQUIREMENTS

PART I. GENERAL REQUIREMENTS FOR PERMANENTLY INSTALLED POOLS, STORABLE POOLS, OUTDOOR SPAS, OUTDOOR HOT TUBS, OR FOUNTAINS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Swimming Pools, Hot Tubs and Spas

Customer Responsibilities

Customer Responsibilities

WARNING: FOR OUTDOOR USE ONLY

My Favorite Pool Builder, Inc.

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

SEVERE INJURY WITH HAND AMPUTATION AND SKULL FRACTURE

Swimming Pool Plans and Specification Report

help make your spa installation a success Commissioned by Caldera Spas

Dan Johnson, CBP Swim, Incorporated Lead Dog Aquatic Consulting

1020 Industrial Drive, Orlinda, TN fax

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

CUSTODIAL Safety Inspection Checklist

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

MOREHEAD CITY COUNTRY CLUB POOL BUILDING

ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

SWIMMING POOL, SPAS, HOT TUB REQUIREMENTS AND GUIDELINES (Updated 3/2018)

Evaporator (DX) Freon Applications 1 12 Tons MHF

Customer Responsibilities

INSTALLATION GUIDE Gas Rangetops

GEN20AD-GEN20AL-GEN18AN

RESIDENTIAL SWIMMING POOL REQUIREMENTS

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Spas Hotels/Resorts Apartments & Condominiums Campgrounds Health Clubs Medical Clinics Waterparks

JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE

Operating Instructions

PRECAUTIONS. Never enter the swim area unless the floating cover is completely removed and stored.

SERVICE & MAINTENANCE MANUAL FOR:

1 Exam Prep NSF/ANSI Tabs and Highlights

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

Saline C 6.0 Junction Box

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Vessel Installation and Operating Manual

(1) Minimum Required. At least one entrance of sufficient area shall be provided to

Jackson County Department of Public Health Application to Construct, Install, Remodel or Modify a Public Swimming Pool

T Y P E V S A B M S E W A G E P U M P

O r i g i n a l. E n d l e s s P o o l. P l a n n i n g G u i d e

Customer Responsibilities

CNG FILLING STATIONS

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

2004 Consumer Planning Guide

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

Transcription:

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

Architect Installation Guidelines for Four-Piece Residential Installations GENERAL LAYOUT Call SwimEx at 800-877-7946 to receive AutoCad Drawings of the SwimEx Model that you will be installing. These drawings can be placed directly into your pool room layout and site drawings. SwimEx pools are available in different versions to accommodate new or existing construction situations. Four Piece Models: Model 500S, 480S, 600S and 800S are standard in four pieces. Optional assembly at the factory is available. Assembled pools are delivered on a flat-bed carrier; sectional pools on common carrier. ** On-site assembly (by owner) typically requires 4 men for two days. Provide a flat & level surface for pool to sit on with a load-bearing capacity of 460 lbs./sq.ft. **Footprint of pool must be level, while the remainder of pit or area can be sloped to drain water. *Model 800S needs 525lbs/sq. ft. Below-ground installation requires a minimum pit of 12 wide by 20 long and 68 deep. The pit side walls provide no structure for the pool; they are only retaining walls. *Model 800S needs 92.5 and Model 500S needs 58. Above-ground installation requires a minimum ceiling height of 10 with no obstructions above the pool (Lights, vents, ducts, beams) ** Check local building codes for minimum ceiling height and required decking area. Every SwimEx comes standard with an entrance ladder. Based on the orientation of the pool within the room, the ladder needs to be placed in the optimum location. Please familiarize yourself with the SwimEx orientation, and make sure that the order specifies whether the ladder should be on the right or left side. The ladder can be placed on either side of the unit for no charge, so long as the order indicates the location. (The entrance ladder is formed in the molding process, thus we must know the desired location at the time the order is placed.) RIGHT SIDE FRONT END CAP SwimEx 400, 500 and 600 PADDLEWHEEL LEFT SIDE

Allow access to equipment and pool via access hatch for in-ground, or access panels for above-ground installations. A ladder should be provided to access the pump, filter and heater located within the pit. DELIVERY REQUIREMENTS: Clear passage for 18-wheel tractor trailer truck to deliver, and forklift on site to offload pool from truck. ** Please review Shipping Section of Manual. If site is not accessible by tractor trailer, this must be specified for special freight quotes. Clear passage from entry to the final location of pool. For the Model 480S and 600S, door openings must be 48 wide by 84 tall with a clear area on both sides of the door. For doors leading to corridors, the door and corridor must each be 70 wide by 84 tall. ** Please review Site Preparation Section of Manual. If you have the Model 800S, a minimum opening of 94 x 64 and a frame width of no more than 3 with no obstructions on either side (i.e. corridors, walls, etc.), you should have no problem brining in any of the pieces. SwimEx units are available assembled at the factory. In these cases, the pool will arrive in one piece and will be craned into position. Planning must be done so that this can occur early in the construction process when complete access to the area is available. Typically this is the most cost-effective way for new construction installations. (Crane provided by owner) A clear, unobstructed work area in and around the pit must be provided for movement of the parts into the pit, and for pool assembly. **No decking shall be constructed until the pool has been filled and water tested. Once the pool has been filled and water tested, the decking will need to be constructed around the SwimEx. This is not part of the SwimEx assembly; Please refer to Deck Construction Section of the Manual for instructions. ELECTRICAL REQUIREMENTS: Standard pool requires 220/240 Volt, single phase, 105 Amps GFCI Breakers to be provided by electrician Paddlewheel Controller: 5 Hp Pools 40 Amp 208/240V Single Phase (Standard) 7.5Hp Pools 60 Amp 208/240V Single Phase (Optional)) Heater : 30 Amp 240V Single Phase Pump: 15 Amp 120V Single Phase ** Pump and Heater can be put on a timer to run 8 hrs per day (By owner) Must provide sub-panel with appropriate GFCI breakers for equipment ***Please refer to Electrical Schematic in Electrical Section of Manual Variable speed controller takes 220/240Volt single phase in and converts it to 3

phase to drive the gearmotor. An electrician, in accordance with local and national electric codes, must make all connections between equipment and circuit breakers. Connections to be made dealing with the SwimEx are from the breaker panel to the variable speed controller, controller to gearmotor, breaker panel to heater, and breaker panel to pump. These must be done on site by an electrician contracted by owner. Conduit needed from the Variable speed controller to the poolroom (near front of pool) for the Swimometer. Conduit must be able to let a 7/8 diameter connector pass through. The location of the Swimometer must be 5 away from the pool and should be determined by the end user of the pool. (Swimometer Dimensions 7-1/8 x 7-1/8 ) Ozonator, 110V plug in unit.should be connected through same line as Pump to ensure that it shuts off when pump is turned off. Other Equipment Considerations: Optional SwimEx equipment: *Please refer to Other Equipment Assemblies Section of the Manual Underwater Lights, 110Volt plug-in unit on right or left side of pool. Provide an on-off switch, in a convenient location for owner. Jet Option : Electrician wires 110Volt to controller and makes 3 wire connection to jet pump e. (Pump and ES Combo air switch control provided.) Non SwimEx Equipment provided by owner Sump Pump: Plumber will locate a sump pump within pit area; connection means must be provided for. Lights under deck or in pit area: Pit area must have lights for future maintenance. Ventilation and exhaust requirements. MECHANICAL REQUIREMENTS: **Please read and familiarize yourself with the Plumbing Section of the Manual Plumbing: Pool is pre-plumbed with all eyeball and suction fittings. On-site plumber (contracted by owner) must make connections between pool and provided pool equipment. All connections are PVC and will vary depending on location. Typical connections are schedule 80 PVC and range from 1 to 3 in diameter. Water fill: ¾ Cold Water fill line for pool (Tempered water can be provided, but is not required.) The fill line must be protected by backflow preventers, as required by local codes. Valve for water fill should be located within poolroom so that operator can see water level as pool is being filled.

Drain: The SwimEx comes with a 2 drain with a shutoff valve, located at the front of the pool. A floor drain, or sump pump and pit, must be provided for semi-annual draining of the pool. The drain is elevated approximately 3 ½ from the floor. Drain will have approximate flow of 80 GPM when pool is full. Ventilation and exhaust from pool room: Small water area exposed to air eliminates the need for large dehumidification systems. Typical water loss due to evaporation is in the area of 4-lbs./ hour for a standard SwimEx pool. HVAC: SwimEx recommends the use of a small dehumidifier within the pit area to keep moisture out, this area is generally below ground and occasionally gets wet due to splashing. The room which the SwimEx pool is placed should have a minimum of an exhaust fan, if it is conditioned, we recommend that there be no air intake to entire home system. Cross contamination of air is possible. Ventilation and exhaust from pool room. Small water area exposed to air eliminates the need for large dehumidification systems. Typical water loss due to evaporation is in the range of 4-lbs./ hour for a standard SwimEx pool. STANDARD POOL EQUIPMENT The following is a list of the standard pool equipment supplied with SwimEx Models Heater: Coates Heater Company Model: 12406T 5.5 KW Electric Heater Dimensions 17 ½ L x 4 W x 14 ½ H Electrical Requirements: 240V Single Phase 30 Amp GFIC Breaker feed Pump/Filter combo: Pentair Pool Products Model: Clean & Clear w/ Option Pump 1 Hp Pump with 75 sq.ft. cartridge filter Dimensions 26 x 24 x 26 high Electrical Requirements: Connections 1 1/2 PVC Glue Unions 110V single phase 15 Amp GFCI breaker Removal of cover req. 39 Height