PRESSURE SWITCHES Bulletin 8757

Similar documents
North American Pressure Switches

Pressure switch for gas and air

Pressure Switch for gas and air

Pressure Switch for gas and air

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves

SPECIFICATIONS ATTENTION

North American 7337A/B/C-4 High Pressure Gas Regulators

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Pressure Switch for gas and air GGAO-A4

North American 7339 High Pressure Gas Regulators

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Noth American 7347 High Pressure Gas Regulators

C645A-E Pressure Switches

Automatic Valve Proving Control

BGA158 Series CE Approved Class A Shutoff Gas Valve

North American Orifice Metering System

Valve Proving System VDK 200 A S06*

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

BGA158 Series CE Approved Class B Shutoff Gas Valve

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Valve Proving System VDK 200 A S02

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Pressure and Vacuum Switches for Process Applications

Tightness controls TC 1 3 and TC 4

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G96 Series BASOTROL Dual Operator Valve

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

G92 Series BASOTROL Automatic Pilot Gas Valve

GAS FUEL VALVE FORM AGV5 OM 8-03

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Data Sheet. P-Series Explosion Proof Pressure Switches

Introduction. Description. Series P48 Pressure Controls for Steam, Air or (hot) Water. Feature and Benefits

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

North American Simplex Basket Strainers for Gas and Oil

Dual Solenoid Gas Valve Installation

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

GM Series Dual-Block Multi-Function Gas Control Valves

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Inert Air (N2) Systems Manual

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

SPECIFICATIONS CAPACITY

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

BVA BUTTERFLY VALVES

C437D,E,F,G,H,J,K and C637B Gas Pressure Switches

PRESSURE, VACUUM AND TEMPERATURE

MEDICAL EQUIPMENT CATALOG

I/P Transducer Positioner Module

SKPx5.xxxUx Gas Valve Actuator with Safety Shutoff Function. SKP15.xxxUx SKP25.xxxUx SKP55.xxxUx SKP75.xxxUx

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

Tightness control TC. Product brochure GB 3 Edition AGA

G95 Series BASOTROL Single Operator Valve

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

CERTIFICATE OF COMPLIANCE

780S Ultra High Purity Series

SKPx5.xxxUx Gas Valve Actuator with Safety Shutoff Function. SKP15.xxxUx SKP25.xxxUx SKP55.xxxUx SKP75.xxxUx

EXPLOSION-PROOF PRESSURE, VACUUM, DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

Electro Controls. Pressure WattsIndustries.co.uk

Certificate of Compliance

120 Series Explosion-Proof Pressure and Differential Pressure Switches

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

LVU2800 Series. Ultrasonic Level Transmitter

GM-7000 Series CE Approved Gas Control Valve

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

INDUSTRIAL EXCESS ESS FLOW VALVES

Part I - Installation

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Pressure controls, differential pressure controls type RT

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

EXPLOSION-PROOF PRESSURE, VACUUM,

System Pressure Manager Standard & System Pressure Manager Plus

PGM PREPIPED GAS MANIFOLD

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

Operator: Save these instructions for future use!

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES

Transcription:

PRESSURE SWITCHES Bulletin 8757 September 2013 Pressure switches are used with Automatic Shutoff Valves or solenoid valves to interrupt fuel fl ow in the event of fuel or air failure. They are also used with Supervising Valve Systems (Bulletin 1857) and to protect regulators and other control devices from excessive pressures. Fives North American offers a variety of standard snap-acting pressure switches to monitor both static and differential pressures. Standard pressure switches are offered in multiple ranges and for different process fl uids including air, natural gas, oil and steam. For applications requiring explosion-proof switches, oxygen service, or any other special requirement, contact Fives North American for further information. 8757-GAO, -GML, -GMH: Pressure switches for gas or air Ranges from 0.16 wc to 200 wc NEMA 4 enclosure FM, UL, CSA approved 8757-12: Pressure switches for gas, air or oil Ranges from 4 wc to 100 psi UL, CE, ANSI/ISA 12.27.01 approved Class I, II, Div. I, II 8757-B4, - D4: Pressure switches for gas, air or oil Ranges from 4.5 wc to 200 psi UL, CE, FM approved 8757-DG: Pressure switches for gas or air Ranges from 0.2 wc to 200 wc FM and UL approved 8757-xNN: Pressure switches for air Ranges from 2 PSI to 180 PSI SPDT snap-action switch NEMA 4X enclosure FM approved 8757-PG, -DS: Pressure switches for air Ranges from 1 wc to 150 PSI FM, UL, CSA approved 8757-H400: Pressure switch for air Ranges from 2 wc to 100 PSI SPDT snap-action switch NEMA 4X enclosure FM, UL, CE approved 8757-L404: Pressure switches for steam Ranges from 5 PSI to 150 PSI Snap-action switch NO, NC, SPDT UL, CSA approved

PRESSURE SWITCHES - STATIC PRESSURE FivesNA Action Range of Max Max Differential Switch Rating Switch Press. Operating Static Ambient Pressure 120Vac 240Vac Designation Service Rise Pressures psi Temp F (Dead Band) (Amps) (Amps) Approvals Enclosure Notes 8757-PG70-153/P1 Air SPDT1 1-30" wc 15,20 (6) 180 4" wc 15 8 UL 1 1,6 8757-PG72-804/P1 Air DPDT2 1-30" wc 15,20 (6) 180 8" wc 5 5 UL 1 2,6 8757-PG70-153/P2 Air SPDT1 0.5-5 psi 15,20 (6) 180 0.5 psi 15 8 UL 1 1,6 8757-PG72-804/P2 Air DPDT2 0.5-5 psi 15,20 (6) 180 1 psi 5 5 UL 1 2,6 8757-H400-440 Air SPDT1 0-2" wc 3,225 (6) 160 0.07-0.25" wc 15 15 FM, UL, CE 4X 1,6 8757-H400-441 Air SPDT1 0-10" wc 3,225 (6) 160 0.15-0.3" wc 15 15 FM, UL, CE 4X 1,6 8757-H400-442 Air SPDT1 0-20" wc 3,225 (6) 160 0.2-0.5" wc 15 15 FM, UL, CE 4X 1,6 8757-H400-443 Air SPDT1 0-80" wc 3,225 (6) 160 0.5-1.8" wc 15 15 FM, UL, CE 4X 1,6 8757-H400-453 Air SPDT1 0-20 psi 20,225 (6) 160 0.05-0.2 psi 15 15 FM, UL, CE 4X 1,6 8757-H400-454 Air SPDT1 0-30 psi 30,225 (6) 160 0.05-0.3 psi 15 15 FM, UL, CE 4X 1,6 8757-DSF-7231/4 Air SPDT1 1-35 psi 35 180 1.5 psi 15 15 FM, UL, CSA 1 1,3 8757-DSF-7231/7 Air SPDT1 5-150 psi 150 180 3 psi 15 15 FM, UL, CSA 1 1,3 8757-12NNCA4 Air SPDT1 0.5-6 psi 200,400 (6) 180 0.4 psi 22 22 FM 4X 1,6 8757-12NNCA45 Air SPDT1 1-16 psi 200,400 (6) 180 0.6 psi 22 22 FM 4X 1,6 8757-4NNCA4 Air SPDT1 2-25 psi 750,1000 (6) 180 1.2 psi 22 22 FM 4X 1,6 8757-4NNCA5 Air SPDT1 3-50 psi 750,1000 (6) 180 1.6 psi 22 22 FM 4X 1,6 8757-4NNCA45 Air SPDT1 4-75 psi 750,1000 (6) 180 2.0 psi 22 22 FM 4X 1,6 8757-6NNCA3 Air SPDT1 12-100 psi 1500,2500 (6) 180 3.6 psi 22 22 FM 4X 1,6 8757-6NNCA5 Air SPDT1 20-180 psi 1500,2500 (6) 180 5.6 psi 22 22 FM 4X 1,6 8757-GAO-A4/4/2 Gas, Air SPDT1 0.16-1.2" wc 7 140 0.12" wc 10 5 FM, UL, CSA 4 1 8757-DG-2I Gas, Air SPDT1 0.2-2.4" wc 8.5 176 0.08-0.12" wc 5 5 FM, UL IP65 1 8757-DG-4I Gas, Air SPDT1 0.4-4.0" wc 8.5 176 0.1-0.16" wc 5 5 FM, UL IP65 1 8757-GAO-A4/4/3 Gas, Air SPDT1 0.4-4.0" wc 7 140 0.2" wc 10 5 FM, UL, CSA 4 1 8757-GAO-A4/4/5 Gas, Air SPDT1 2-20" wc 7 140 0.4" wc 10 5 FM, UL, CSA 4 1 8757-DG-20I Gas, Air SPDT1 1-20" wc 8.5 176 0.31-0.59" wc 5 5 FM, UL IP65 1 8757-GML-A4/4/4 Gas, Air SPDT1 1-20" wc 7 140 0.4" wc 10 5 FM, UL, CSA 4 1,7 8757-GAO-A4/4/6 Gas, Air SPDT1 12-60" wc 7 140 1.2" wc 10 5 FM, UL, CSA 4 1 8757-DG-60I Gas, Air SPDT1 12-60" wc 8.5 176 1.17-1.95" wc 5 5 FM, UL IP65 1 8757-GML-A4/4/6 Gas, Air SPDT1 12-60" wc 7 140 1.2" wc 10 5 FM, UL, CSA 4 1,7 8757-GMH-A4/4/6 Gas, Air SPDT1 12-60" wc 7 140 1.2" wc 10 5 FM, UL, CSA 4 1,7 8757-GAO-A4/4/8 Gas, Air SPDT1 40-200" wc 14 140 4.0" wc 10 5 FM, UL, CSA 4 1 8757-DG-200I Gas, Air SPDT1 40-200" wc 8.5 176 3.12-6.63" wc 5 5 FM, UL IP65 1 8757-D4-30I Gas, Air, Oil SPDT1 4.5-30" wc 40,160 (6) 150 1.5-2.5" wc 15 15 FM, UL, CE 4X 1,5,6,8,9 8757-D4-60I Gas, Air, Oil SPDT1 9-60" wc 40,160 (6) 150 1.5-3.5" wc 15 15 FM, UL, CE 4X 1,5,6,8,9 8757-12-65I Gas, Air, Oil SPDT1 4-65" wc 25,50 (6) 203 5.5" wc 5 5 CE,ANSI/ISA 4X,Class I,II 1,5,6,9 12.27.01 Div. I, II 8757-D4-100I Gas, Air, Oil SPDT1 15-100" wc 40,160 (6) 150 2.5-5.5" wc 15 15 FM, UL, CE 4X 1,5,6,8,9 8757-D4-150I Gas, Air, Oil SPDT1 22.5-150" wc 40,160 (6) 150 4.5-8.5" wc 15 15 FM, UL, CE 4X 1,5,6,8,9 8757-12-5P Gas, Air, Oil SPDT1 0.5-5 psi 25,50 (6) 203 0.4 psi 5 5 CE,ANSI/ISA 4X,Class I,II 1,5,6,9 12.27.01,UL,CE Div. I, II 8757-12-15P Gas, Air, Oil SPDT1 1-15 psi 300,500 (6) 203 0.5-2.0 psi 5 5 CE,ANSI/ISA 4X,Class I,II 1,5,6,9 12.27.01 Div. I, II 8757-B4-15P Gas, Air, Oil SPDT1 2.25-15 psi 120,500 (6) 150 0.5-1.5 psi 15 15 FM, UL, CE 4X 1,5,6,8,9 8757-B4-30P Gas, Air, Oil SPDT1 4.5-30 psi 120,500 (6) 150 0.5-1.5 psi 15 15 FM, UL, CE 4X 1,5,6,8,9 8757-12-50P Gas, Air, Oil SPDT1 3-50 psi 300,500 (6) 203 0.5-4 psi 5 5 CE,ANSI/ISA 4X,Class I,II 1,5,6,9 12.27.01 Div. I, II 8757-B4-60P Gas, Air, Oil SPDT1 9-60 psi 120,500 (6) 150 1.0-3.5 psi 15 15 FM, UL, CE 4X 1,5,6,8,9 8757-12-100P Gas, Air, Oil SPDT1 5-100 psi 300,500 (6) 203 1.0-8 psi 5 5 CE,ANSI/ISA 4X,Class I,II 1,5,6,9 12.27.01 Div. I, II 8757-B4-100P Gas, Air, Oil SPDT1 15-100 psi 400,1000 (6) 150 1.5-5 psi 15 15 FM, UL, CE 4X 1,5,6,8,9 8757-B4-200P Gas, Air, Oil SPDT1 30-200 psi 400,1000 (6) 150 5-13 psi 15 15 FM, UL, CE 4X 1,5,6,8,9 8757-L404F1078 Steam SPDT1 5-50 psi 85 150 6-14 psi 8 5.1 UL, CSA 1 1,4 8757-L404F1102 Steam SPDT1 10-150 psi 225 150 10-22 psi 8 5.1 UL, CSA 1 1,4 Bulletin 8757 Page 2

PRESSURE SWITCHES - DIFFERENTIAL PRESSURE FivesNA Action Range of Max Max Differential Switch Rating Switch Pressure Operating Static Ambient Pressure 120Vac 240Vac Designation Service Rise Pressures psi Temp F (Dead Band) (Amps) (Amps) Approvals Enclosure Notes 8757-PG70-153/P1 Air SPDT1 1-30" wc 2 180 4" wc 15 8 UL 1 1 8757-PG72-804/P1 Air DPDT2 1-30" wc 2 180 8" wc 5 5 UL 1 2 8757-PG70-153/P2 Air SPDT1 0.5-5 psi 10 180 0.5 psi 15 8 UL 1 1 8757-PG72-804/P2 Air DPDT2 0.5-5 psi 10 180 1 psi 5 5 UL 1 2 8757-PGW70-153/P2 Air SPDT1 0.5-5 psi 10 180 0.5 psi 15 8 UL 3R 1 8757-H400K-455 Air SPDT1 5-80" wc 225 160 1-4" wc 15 15 FM, UL, CE 4X 1 8757-H400K-457 Air SPDT1 3-30 psi 225 160 0.1-0.4 psi 15 15 FM, UL, CE 4X 1 8757-DG-4I Air SPDT1 0.4-4.0" wc 8.5 176 0.1-0.16" wc 5 5 FM, UL IP65 1 8757-DG-20I Air SPDT1 1-20" wc 8.5 176 0.31-0.59" wc 5 5 FM, UL IP65 1 8757-DG-60I Air SPDT1 12-60" wc 8.5 176 1.17-1.95" wc 5 5 FM, UL IP65 1 8757-DG-200I Air SPDT1 40-200" wc 8.5 176 3.12-6.63." wc 5 5 FM, UL IP65 1 NOTES: 1. SPDT (Single Pole Double Throw) action means the switch makes one circuit and breaks another. 2. DPDT (Double Pole Double Throw) action means the switch makes two circuits and breaks two circuits. 3. These pressure switches must be mounted level and where they are relatively free from vibration. 4. A siphon (ordered seperately) must always be connected between the pressure switch and the line when used with steam to act as a themal buffer. Specify R830-6699 for 180 siphon, R830-6698 for a 90 siphon. 5. When used with pre-heated oil, a siphon loop must always be connected between the pressure switch and main pipe to act as a themal buffer. 6. Pressures listed under heading "Max Static psi" are the switches' Proof Pressures. 7. Manual Reset required. 8. These switches have a 1/4" vent which must be piped to an approved location. 9. These switches do not require a conduit seal to meet 4.1.3.2 of NFPA 86 2011. Bulletin 8757 Page 3

PRESSURE SWITCHES - STATIC PRESSURE - 24VDC Switch FivesNA Action Range of Max Max Differential Rating Switch Press. Operating Static Ambient Pressure 24Vdc Designation Service Rise Pressures PSI Temp F (Dead Band) (Amps) Approvals Enclosure Notes 8757-H400-440 Air SPDT1 0-2" wc 3,225 (6) 160 0.07-0.25" wc 2 res, 1 ind FM, UL, CE 4X 1,6 8757-H400-441 Air SPDT1 0-10" wc 3,225 (6) 160 0.15-0.3" wc 2 res, 1 ind FM, UL, CE 4X 1,6 8757-H400-442 Air SPDT1 0-20" wc 3,225 (6) 160 0.2-0.5" wc 2 res, 1 ind FM, UL, CE 4X 1.6 8757-H400-443 Air SPDT1 0-80" wc 3,225 (6) 160 0.5-1.8" wc 2 res, 1 ind FM, UL, CE 4X 1,6 8757-H400-453 Air SPDT1 0-20 psi 20,225 (6) 160 0.05-0.2 psi 2 res, 1 ind FM, UL, CE 4X 1,6 8757-H400-454 Air SPDT1 0-30 psi 30,225 (6) 160 0.05-0.3 psi 2 res, 1 ind FM, UL, CE 4X 1,6 8757-12NNCA4 Air SPDT1 0.5-6 psi 200,400 (6) 180 0.4 psi 5 FM 4X 1,6 8757-12NNCA45 Air SPDT1 1-16 psi 200,400 (6) 180 0.6 psi 5 FM 4X 1,6 8757-4NNCA4 Air SPDT1 2-25 psi 750,1000 (6) 180 1.2 psi 5 FM 4X 1,6 8757-4NNCA5 Air SPDT1 3-50 psi 750,1000 (6) 180 1.6 psi 5 FM 4X 1,6 8757-4NNCA45 Air SPDT1 4-75 psi 750,1000 (6) 180 2.0 psi 5 FM 4X 1,6 8757-6NNCA3 Air SPDT1 12-100 psi 1500,2500 (6) 180 3.6 psi 5 FM 4X 1,6 8757-6NNCA5 Air SPDT1 20-180 psi 1500,2500 (6) 180 5.6 psi 5 FM 4X 1,6 8757-DG-2I-24VDC Gas, Air SPDT1 0.2-2.4" wc 8.5 176 0.08-0.12" wc 0.1 FM, UL IP65 1 8757-DG-4I-24VDC Gas, Air SPDT1 0.4-4.0" wc 8.5 176 0.1-0.16" wc 0.1 FM, UL IP65 1 8757-DG-20I-24VDC Gas, Air SPDT1 1-20" wc 8.5 176 0.31-0.59" wc 0.1 FM, UL IP65 1 8757-DG-60I-24VDC Gas, Air SPDT1 12-60" wc 8.5 176 1.17-1.95" wc 0.1 FM, UL IP65 1 8757-DG-200I-24VDC Gas, Air SPDT1 40-200" wc 8.5 176 3.12-6.63" wc 0.1 FM, UL IP65 1 8757-D4-30I-24VDC Gas, Air, Oil SPDT1 4.5-30" wc 40,160 (6) 150 1.5-2.5" wc 6 FM, UL, CE 4X 1,5,6,8,9 8757-D4-60I-24VDC Gas, Air Oil SPDT1 9-60" wc 40,160 (6) 150 1.5-3.5" wc 6 FM, UL, CE 4X 1,5,6,8,9 8757-12-65I Gas, Air, Oil SPDT1 4-65" wc 25,50 (6) 203 5.5" wc 5 res, 3 ind CE,ANSI/ISA 12.27.01 4X, Cls I,II Div.I,II 1,5,6,9 8757-D4-100I-24VDC Gas, Air, Oil SPDT1 15-100" wc 40,160 (6) 150 2.5-5.5" wc 6 FM, UL, CE 4X 1,5,6,8,9 8757-D4-150I-24VDC Gas, Air, Oil SPDT1 22.5-150" wc 40,160 (6) 150 4.5-8.5" wc 6 FM, UL, CE 4X 1,5,6,8,9 8757-12-5P Gas, Air, Oil SPDT1 0.5-5 psi 25,50 (6) 203 0.4 psi 5 res, 3ind CE,ANSI/ISA 12.27.01 4X, Cls I,II Div.I,II 1,5,6,9 8757-12-15P Gas, Air, Oil SPDT1 1-15 psi 300,500 (6) 203 0.5-2.0 psi 5 res, 3 ind CE,ANSI/ISA 12.27.01 4X, Cls I,II Div.I,II 1,5,6,9 8757-B4-15P-24VDC Gas, Air, Oil SPDT1 2.25-15 psi 120,500 (6) 150 0.5-1.5 psi 6 FM, UL, CE 4X 1,5,6,8,9 8757-B4-30P-24VDC Gas, Air, Oil SPDT1 4.5-30 psi 120,500 (6) 150 0.5-1.5 psi 6 FM, UL, CE 4X 1,5,6,8,9 8757-12-50P Gas, Air, Oil SPDT1 3-50 psi 300,500 (6) 203 0.5-4 psi 5 res, 3 ind CE,ANSI/ISA 12.27.01 4X, Cls I,II Div.I,II 1,5,6,9 8757-B4-60P-24VDC Gas, Air, Oil SPDT1 9-60 psi 120,500 (6) 150 1.0-3.5 psi 6 FM, UL, CE 4X 1,5,6,8,9 8757-12-100P Gas, Air, Oil SPDT1 5-100 psi 300,500 (6) 203 1.0-8 psi 5 res, 3 ind CE,ANSI/ISA 12.27.01 4X, Cls I,II Div.I,II 1,5,6,9 8757-B4-100P-24VDC Gas, Air, Oil SPDT1 15-100 psi 400,1000 (6) 150 1.5-5 psi 6 FM, UL, CE 4X 1,5,6,8,9 8757-B4-200P-24VDC Gas, Air, Oil SPDT1 30-200 psi 400,1000 (6) 150 5-13 psi 6 FM, UL, CE 4X 1,5,6,8,9 PRESSURE SWITCHES - DIFFERENTIAL PRESSURE - 24VDC 8757-H400K-455 Air SPDT1 5-80" wc 225 160 1-4" wc 5 res, 3 ind FM, UL CE 4X 1 8757-H400K-457 Air SPDT1 3-30 psi 225 160 0.1-0.4 psi 5 res, 3 ind FM, UL, CE 4X 1 8757-DG-4I-24VDC Air SPDT1 0.4-4.0" wc 8.5 176 0.1-0.16" wc 0.1 FM, UL IP65 1 8757-DG-20I-24VDC Air SPDT1 1-20" wc 8.5 176 0.31-0.59" wc 0.1 FM, UL IP65 1 8757-DG-60I-24VDC Air SPDT1 12-60" wc 8.5 176 1.17-1.95" wc 0.1 FM, UL IP65 1 8757-DG-200I-24VDC Air SPDT1 40-200" wc 8.5 176 3.12-6.63" wc 0.1 FM, UL IP65 1 NOTES: 1. SPDT (Single Pole Double Throw) action means the switch makes one circuit and breaks another. 2. DPDT (Double Pole Double Throw) action means the switch makes two circuits and breaks two circuits. 3. These pressure switches must be mounted level and where they are relatively free from vibration. 4. A siphon (ordered seperately) must always be connected between the pressure switch and the line when used with steam to act as a themal buffer. Specify R830-6699 for 180 siphon, R830-6698 for a 90 siphon. 5. When used with pre-heated oil, a siphon loop must always be connected between the pressure switch and main pipe to act as a themal buffer. 6. Pressures listed under heading "Max Static psi" are the switches' Proof Pressures. 7. Manual Reset required. 8. These switches have a 1/4" vent which must be piped to an approved location. 9. These switches do not require a conduit seal to meet 4.1.3.2 of NFPA 86 2011. Bulletin 8757 Page 4

DIMENSIONS in inches (mm) 5.09 (129.7) 5.09 (129.7) 8757-H400 4.00 4.28 (101.6) (108.7) 2.50 (63.5) 0.75-14 FNPT thru near wall only 0.875" knockout on opposite side and centered in rear of enclosure Clearance for 0.25" screw (2) mounting holes 0.25" FNPT (40.5) 2.53 (64.3) 1.53 (129.7) 5.09 (129.7) 5.50 (139.4) 4.00 (101.6) (40.5) 7.00 (177.8) 2.50 (63.5) LOW HIGH Clearance for 0.25" screw (2) mounting holes 0.25" FNPT 1.53 (38.8) 8757-H400K 0.75-14 FNPT thru near wall only 0.875" DIA. knockout on opposite side and centered in rear of enclosure 2.53 (64.3) 8757-DG Bulletin 8757 Page 5

Reset button (only applies to 8757-GML/-GMH) 3 (76) 2.75 (69.9) 1.31 (33.3) 2.22 (56.5) 1.13 (28.7) 1.03 (26.2) 2.8 (72) 5.94 (150.9) Electrical conduit 0.75" FNPT (40.4) 2.3 (58) 1.5 (37.4) 0.5" FNPT conduit 2.31 (58.7) 4.25 (108.1) 1.97 (50.1) 0.5" FNPT 0.28 (7.1) 0.4 (10) 0.25" FNPT Integrated test nipple 8757-GAO, -GML, -GMH 8757-4NN 2.75 (69.9) 1.31 (33.3) 2.22 (56.5) 1.13 (28.7) 1.03 (26.2) 2.75 (69.9) 1.31 (33.3) 2.22 (56.5) 1.13 (28.7) 1.03 (26.2) Electrical conduit 0.75" FNPT Electrical conduit 0.75" FNPT 5.78 (146.8) (40.4) 5.89 (149.5) (40.4) 2.15 (54.6) 4.25 (108.1) 1.97 (50.1) 0.5" FNPT 0.28 (7.1) 2.26 (57.4) 4.25 (108.1) 1.97 (50.1) 0.5" FNPT 3.72 (94.5) 0.73 (18.7) 0.28 (7.1) 8757-6NN 8757-12NN 4.5 (115) 3.25 (83) 2.75(70) 1.95 (50) 4.34 (111) 1.93 (49) 3.875 HOLE 0.5 INCH FOR (99) 13.18 CONDUIT (30) 0.81(21) DIFFERENTIAL ADJUSTMENT SCREW 3.75 (95) 4.95 (126) 0.18 0.34 (5 X 9) KNOCKOUT 1.81 (46) MAIN SCALE ADJUSTMENT SCREW CLEAR PLASTIC COVER 1.06 (27) 1.5 (38) 0.25" FNPT 2.12 (54) 8757-L404 Bulletin 8757 Page 6

2.25 (57.15) 6.01 (152.8) 1.62 (41.28) 8757-DS 0.25" MNPT 0.87 (22.23) Adjustment screws 0.62 (15.88) 0.5" Conduit hole Adjustment screw 7 (177.80) 6.01 (152.78) 8757-PG 8.25 (209.55) (3)0.20 (5.16) Mounting holes equally spaced on a 6.5 (165.10) B.C. 0.125 Female NPT negative process 45º 30º 1.42 (36.12) 0.87 (22.23) Conduit 0.5" Male NPT X 0.125" female NPT positive process 0.75 (19.05) Clearance for cover removal 0.25 (6.35) 4 (101.6) 0.53 (13.49) 1.18 (30.16) Factory Sealed Lead Wires 72" Lg. Factory Sealed Lead Wires 72" Lg. 0.5 Male Conduit 0.5 Male Conduit 5.5 (139.8) 3.5 (88.9) 1.25 (31.8) 5 (127) 1.25 (32) 0.5" NPT 0.5" NPT 8757-12-65I 8757-12-5P 8757-12-15P 8757-12-50P 8757-12-100P Bulletin 8757 Page 7

Bulletin 8757 Page 8 4 (102) 2.31 (59) 3.32 (84) 0.75 Conduit 8757-D4-30I 8757-D4-60I 8757-D4-100I 8757-D4-150I 5.81 (147) 0.32 (8) 0.25" Vent 1.62 (41) 5.12 (130) 0.25" NPT 4 (102) 2.37 (60) 8757-B4-15P 8757-B4-30P 8757-B4-60P 8757-B4-100P 8757-B4-200P 5.75 (147) 3.31 (84) 0.75 Conduit 0.31 (8) VENT 0.25" Vent 1.62 (41) 3.25 (83) 0.25" NPT DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL. WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment.the presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Parts of this product may exceed 160F in operation and present a contact hazard. Fives North American Combustion, Inc. urges compliance with National Safety Standards and Insurance Underwriters recommendations, and care in operation. Fives North American Combustion, Inc. - 4455 East 71st Street - Cleveland, OH 44105 USA - Phone 216.271.6000 Fax 216.641.7852 - email: fna.sales@fi vesgroup.com - www.fi vesgroup.com/fi vesna 9-2013 B8757