INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015

Similar documents
Network Regulator Maintenance Operatives LS (Non-Accredited)

Overview EUSSAM12. Carry out tightness testing and direct purging of gas installations

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

Manual Actuated Boiler Blowdown Valves

The routine maintenance and inspection of local exhaust ventilation (LEV)

Pressure Systems Safety Regulation

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Drum / cylinder handling

Dangerous Substances & Explosive Atmospheres Regulation 2002 The Basics. Richard Cowen Dip SH, Dip RSA, CMIOSH, MIIRSM, FRSPH, GI Fire E

Non-domestic meter installations

Overview EUSDSG3.6. Gas tightness testing and direct purging

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

Non-domestic meter installations

TSS21 Sealed Thermostatic Steam Tracer Trap

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Spirax Compact FREME Flash Recovery Energy Management Equipment

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

6-5 Maintenance Manual

TABLE OF CONTENT

SRV66 Sanitary Pressure Reducing Valve

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents

SAFETY PRINCIPLES FOR PRESSURE REGULATORS FOR MEDICAL OXYGEN CYLINDERS

DF1 and DF2 Diffusers

Overview EUSDSG3.12. Install gas meters and regulators (2.5 to 16.0m3/hr)

IGEM/GL/5 Edition 3 Communication 1783 Managing new works, modifications and repairs

DSEAR-Classification of Hazardous Areas (Zoning) and Selection of Equipment

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

IGEM/UP/12 Edition 2 Communication 1778 Application of burners and controls to gas fired process plant

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS

UTAS EH&S INSTRUCTION No. 036 June 2012 Revision No. 3. Purging of Flammable Gas Equipment and/or Piping (Explosion Hazard)

ACS.TPCP1 SAFETY ASSESSMENT CRITERIA INITIAL AND RE-ASSESSMENT NON-DOMESTIC NATURAL GAS; LPG; OTHER GASES TESTING AND PURGING

Medium pressure two-stage meter regulators for gas flow rates not exceeding 6 m 3 h -1

IGEM/GM/6 Edition 2 Communication 1750 Non-domestic meter installations. Standard designs

DESIGN FOR NATURAL GAS INSTALLATIONS ON INDUSTRIAL AND COMMERCIAL PREMISES WITH RESPECT TO DSEAR

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

NATURAL GAS MAINTENANCE. Part 192 Subpart "M"

ACS.TPCP1A SAFETY ASSESSMENT CRITERIA INITIAL AND RE-ASSESSMENT NON-DOMESTIC NATURAL GAS TESTING AND PURGING

Safety Services Guidance. Guidance on: The Provision and Use of Work Equipment Regulations 1998 (PUWER)

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

IGEM/GM/7B Edition 2 Communication 1804 Hazardous area classification for gas metering equipment

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Frequently Asked Questions Directive 056 Facilities Technical

TP1 and TP2 Temporary Cone Shaped Strainers

INSTITUTION OF GAS ENGINEERS AND MANAGERS

QuickHeat TM Packaged Heat Exchanger Solutions

User Information Sheet 015

TABLE OF CONTENTS PART 2 - CONFINED SPACES

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

CP10 Sensor Installation and Maintenance Instructions

ACS.CoNGLP1 SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC NATURAL GAS TO LPG GENERIC

Summary of the MRA LPG Codes of Practice

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Tightness testing and direct purging of small Liquefied Petroleum Gas/Air, Natural Gas and Liquefied Petroleum Gas installations

GUIDANCE IN-SERVICE INSPECTION PROCEDURES

Installation pipework on industrial and commercial premises

NORMAL OPERATING PROCEDURES Operating Parameter Information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Gas Fired Residential Heating Boilers

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE

CVS10 Sanitary Check Valves

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Dival 500 Pressure Regulators

CS10-1 Stainless Steel Clean Steam Separator

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

MAINTENANCE AND SAFETY OF CNG REFUELLING STATIONS

STD Spray Type Desuperheater

Types 749B and R130 Changeover Manifolds

Paint Spraying and Other Painting Processes Fire Safety

Title: Pressure Relieving and Venting Devices Function: Ecology & Safety No.: BC Page: 1 of 7 Reviewed: 6/30/12 Effective: 7/1/12 (Rev.

IGEM/UP/11 Edition 3 Communication 1821 Gas installations for educational establishments

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

MFP14-PPU (Vented) Automatic Packaged Pump Units

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

Oxygen Usage Best Practice Guide

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Meter regulators of nominal diameter 32 mm (1¼ inch) and not exceeding 150 mm (6 inch) and for inlet pressures not exceeding 75 mbar

TExT Thorough Examination & Test of LEV Local Exhaust Ventilation Systems

CRAFTSMAN EXAMINATION, NOVEMBER 2007 GASFITTING ANSWER SCHEDULE

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

SAFETY MANUAL PURGING, VENTING & DRAINING PROCEDURE TABLE OF CONTENTS 1. INTRODUCTION SCOPE DEFINITIONS PROCEDURE...

DCV6 Disc Check Valve

ML3M Monnier Miniature Compressed Air Lubricator

Safe Work Practices / Procedures / Instruction CONFINED SPACE

PROTEGO Braunschweiger Flammenfilter GmbH

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

PV4 and PV6 Piston Valves

Additional requirements for all types of entry are described in Section Determining the Applicable Entry Method

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

Orpheus Pressure Reduction Modulev4

MF2M Monnier Miniature Compressed Air Filter

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

NZQA registered unit standard version 3 Page 1 of 6

Transcription:

INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015 BUILDING PARTNERSHIPS FOR ENERGY SECURITY www.inogate.org

EN 12186 GAS SUPPLY SYSTEMS GAS PRESSURE REGULATING STATIONS FOR TRANSMISSION AND DISTRIBUTION FUNCTIONAL REQUIREMENTS

PRESSURE REGULATOR STANDARDS EN 12186:2000 Gas Supply Systems Gas Pressure Regulating Stations for Transmission and Distribution Functional Requirements

PRESSURE REGULATOR STANDARDS EN 12186:2000 Gas Supply Systems Gas Pressure Regulating Stations for Transmission and Distribution Functional Requirements EN 12279:2000 Gas Supply Systems Gas Pressure Regulating Installations on Service Lines Functional Requirements

PRESSURE REGULATOR STANDARDS EN 12186:2000 Gas Supply Systems Gas Pressure Regulating Stations for Transmission and Distribution Functional Requirements EN 12279:2000 Gas Supply Systems Gas Pressure Regulating Installations on Service Lines Functional Requirements IGE/TD/13 Pressure Regulating Installations for Transmission and Distribution Systems

PRESSURE REGULATOR STANDARDS EN 12186:2000 Gas Supply Systems Gas Pressure Regulating Stations for Transmission and Distribution Functional Requirements EN 12279:2000 Gas Supply Systems Gas Pressure Regulating Installations on Service Lines Functional Requirements IGE/TD/13 Pressure Regulating Installations for Transmission and Distribution Systems ASME 31.8 Gas Transmission and Distribution Piping Systems

HAZARDOUS AREA STANDARDS BS EN 60079-10-1 - Classification of areas -Explosive gas atmospheres IGE/SR/25: Edition 2 2010; Hazardous Area Classification of Natural Gas Installations

SCOPE - EN 12186 Pressure limit 100 Bar If the inlet pipework of the station is a service line and the maximum upstream operating pressure does not exceed 16 bar and the design flowrate is equal to or less than 200 m3/h under normal conditions, EN 12279 applies.

SCOPE - EN 12186 Pressure, design and testing Pressure control Continuity of supply Quality and management system Environmental impact Layout of the gas pressure regulating station Housings

Design of the station Continuity of supply Gas pre-heating Filters, separators, scrubbers Noise control Apertures and vent lines Hazardous areas Lightning and earthing SCOPE - EN 12186 Cathodic protection and electrical isolation Pressure control equipment and ancillaries Pipework Welding Instrumentation pipework Stress analysis Standard pressure equipment Isolating valves

Scope of EN 12186 Pressure Control Pressure regulating system Pressure safety system Safety shut-off devices Monitors Venting pressure safety devices Pressure alarm system Instrumentation Bypasses

SCOPE - EN 12186 Pressure testing Commissioning Operation and maintenance Decommissioning and disposal

Design pressure (DP) EN 12186 -TERMINOLOGY Pressure on which design calculations are based

Design pressure (DP) EN 12186 -TERMINOLOGY Pressure on which design calculations are based Operating pressure (OP) Pressure which occurs within a system under normal operating conditions

Design pressure (DP) EN 12186 -TERMINOLOGY Pressure on which design calculations are based Operating pressure (OP) Pressure which occurs within a system under normal operating conditions Maximum operating pressure (MOP) Maximum pressure at which a system can be operated continuously under normal operating conditions NOTE Normal operating conditions are: no fault in any device or stream.

EN 12186 -TERMINOLOGY Temporary operating pressure (TOP) Pressure at which a system can be operated temporarily under control of regulating devices

EN 12186 -TERMINOLOGY Temporary operating pressure (TOP) Pressure at which a system can be operated temporarily under control of regulating devices Maximum incidental pressure (MIP) Maximum pressure which a system can experience during a short time, limited by the safety devices

EN 12186 Pressure relationship

EN 12186 SAFETY SYSTEMS A pressure safety system is not needed if MOP is < 100 mbar

EN 12186 SAFETY SYSTEMS A pressure safety system is not needed if MOP is < 100 mbar A single pressure safety system shall be installed if MOP is >100 mbar and < 16 Bar

EN 12186 SAFETY SYSTEMS A pressure safety system is not needed if MOP is < 100 mbar A single pressure safety system shall be installed if MOP is >100 mbar and < 16 Bar A single pressure safety system plus a second device shall be installed if MOP is > 16 bar and.

EN 12186 IGEM TD 13

RISK MITIGATION Fluctuation in downstream pressure potentially leads to metering measurement errors

RISK MITIGATION Fluctuation in downstream pressure potentially leads to metering measurement errors Over pressure of the downstream pipework potentially leads to pipe failure, leakage, fire and/or explosion endangering life and/or property

RISK MITIGATION Fluctuation in downstream pressure potentially leads to metering measurement errors Over pressure of the downstream pipework potentially leads to pipe failure, leakage, fire and/or explosion endangering life and/or property Interruption in gas supply potentially leads to unignited gas entering a building and when supplies are reinstated potentially causes fire and/or explosion endangering life and/or property.

UK IGE TD 13 STANDARD For upstream pressures less than 100 mbar no protection device is required

UK IGE TD 13 STANDARD For upstream pressures less than 100 mbar no protection device is required For upstream pressures greater than 100 mbar but less than 2 Bar then one safety device is recommended

UK IGE TD 13 STANDARD For upstream pressures less than 100 mbar no protection device is required For upstream pressures greater than 100 mbar but less than 2 Bar then one safety device is recommended For upstream pressures greater than 2 Bar then 2 safety devices are recommended unless a risk assessment determines that one device is acceptable

UK IGE TD 13 DESIGN

UK IGE TD 13 DESIGN

UK IGE TD 13 DESIGN

UK IGE TD 13 DESIGN

UK IGE TD 13 DESIGN

UK IGE TD 13 DESIGN

UK IGE TD 13 DESIGN

UK IGE TD 13 DESIGN

Show video UK - PRMS

MAINTENANCE REGIME

EN 12186 -Maintenance A structured decision-making process shall be used to identify the optimum maintenance requirements. Optimum maintenance requirements are dependent on a number of factors, including the operating conditions and duty.

EN 12186 -Maintenance Maintenance utilizes any one or a combination of philosophies, such as: condition based maintenance; maintenance at regular intervals; breakdown maintenance.

MAINTENANCE REGIME UK

ROUTINE INSPECTION Routine Inspection Functional check Major Overhaul

TYPICAL MAINTENANCE REGIME PRMS Type Network, large commercial and industrial installations and residential installations supplying more than 10 premises Small commercial and residential installations supplying less than 10 premises Routine inspection frequency As determined by local risk assessment As determined by local risk assessment - every 5 years minimum Functional check frequency 12 months minimum For installations inside an enclosure no less frequent than every 10 years and for all other installations no less frequent than every 6 years Major overhaul frequency Determined by manufacturers recommendations but no less frequent than every 6 years Determined by manufacturers recommendations

ROUTINE INSPECTION Check security of the site and note any abnormalities. Ensure that site labels, where used, are correctly displayed Note any defects in the structure of the housing and record on appropriate document(s) Check atmosphere around the installation for the presence of gas and report any leakage found Check installation for water ingress and pipework/regulator for corrosion. Report any significant deterioration

ROUTINE INSPECTION Check that the relief vents are correctly positioned and free from any visible obstructions Connect a pressure gauge to the test nipple on the outlet of the regulator/meter and record the outlet pressure. Report any deviation from set point Report any nearby works or buildings extensions which may have a detrimental effect on the operation of the installation, e.g. additional flues or electrical work

ROUTINE INSPECTION Lubricate locks and hinges where appropriate Check if the fire valve cover/box is still accessible and report as appropriate

FUNCTIONAL CHECK All those items for Routine Inspection If a bypass facility exists, connect a correctly sized regulator to maintain supply to the consumers If not, the supply to the consumer must be interrupted. Where it is necessary to interrupt customers supplies, the consumer installation should be tested before bringing back into service Check the lock-up of the regulator

FUNCTIONAL CHECK Isolate stream and check for leakage through isolation valve On stand-alone filter, check condition of element and clean/change as necessary Check the set point of the relief valve by gradually applying a controlled pressure to the outlet connection of the regulator. Note - If the slam shut trips before the relief valve lifts, record the trip pressure

FUNCTIONAL CHECK Check the slam-shut valve trip pressure (minimum of 3 trips) by applying a controlled pressure to the impulse line or to the outlet connection of the regulator. If any faults are found during testing they must be reported through a Fault Data Collection Scheme Before leaving site check all connections for leakage Ensure that the site is tidy and secure on leaving site

MAJOR OVERHAUL Refer to manufacturers recommendations

BS EN 60079-10-1:2009 EXPLOSIVE ATMOSPHERES PART 10-1: CLASSIFICATION OF AREAS EXPLOSIVE GAS ATMOSPHERES

BS EN 60079-10-1:2009 - SCOPE This part of IEC 60079 is concerned with the classification of areas where flammable gas or vapour or mist hazards may arise and to be used for selection and installation of equipment for use in a hazardous area

BS EN 60079-10-1:2009 - Definitions Explosive gas atmosphere Mixture with air, under atmospheric conditions, of flammable substances in the form of gas or vapour, which, after ignition, permits self-sustaining flame propagation

BS EN 60079-10-1:2009 - Definitions Explosive gas atmosphere Mixture with air, under atmospheric conditions, of flammable substances in the form of gas or vapour, which, after ignition, permits self-sustaining flame propagation Hazardous area (on account of explosive gas atmospheres) An area in which an explosive gas atmosphere is or may be expected to be present, in quantities such as to require special precautions for the construction, installation and use of equipment

BS EN 60079-10-1:2009 - Zones Zones Hazardous areas are classified into zones based upon the frequency of the occurrence and duration of an explosive gas atmosphere, as follows:

BS EN 60079-10-1:2009 - Zones Zones Hazardous areas are classified into zones based upon the frequency of the occurrence and duration of an explosive gas atmosphere, as follows: Zone 0 An area in which an explosive gas atmosphere is present continuously or for long periods or frequently

BS EN 60079-10-1:2009 - Zones Zones Hazardous areas are classified into zones based upon the frequency of the occurrence and duration of an explosive gas atmosphere, as follows: Zone 0 An area in which an explosive gas atmosphere is present continuously or for long periods or frequently Zone 1 An area in which an explosive gas atmosphere is likely to occur in normal operation occasionally

BS EN 60079-10-1:2009 - Zones Zones Hazardous areas are classified into zones based upon the frequency of the occurrence and duration of an explosive gas atmosphere, as follows: Zone 0 An area in which an explosive gas atmosphere is present continuously or for long periods or frequently Zone 1 An area in which an explosive gas atmosphere is likely to occur in normal operation occasionally Zone 2 Area in which an explosive gas atmosphere is not likely to occur in normal operation but, if it does occur, will persist for a short period only

BS EN 60079-10-1:2009 EXPLOSIVE ATMOSPHERE Release rate Quantity of flammable gas, vapour or mist emitted per unit time from the source of release Ventilation Movement of air and its replacement with fresh air due to the effects of wind, temperature gradients, or artificial means (for example, fans or extractors)

BS EN 60079-10-1:2009 EXPLOSIVE ATMOSPHERE Lower explosive limit (LEL) Concentration of flammable gas, vapour or mist in air below which an explosive gas atmosphere will not be formed 5% gas in air Upper explosive limit (UEL) Concentration of flammable gas, vapour or mist in air, above which an explosive gas atmosphere will not be formed -15% gas in air

IGEM SR 25 Hazardous Area Classification of Natural Gas installations

IGEM SR 25 Secondary Releases

IGEM SR 25 Secondary Releases

IGEM SR 25 Secondary Releases OUTDOOR FREELY VENTILATING OUTDOOR CONGESTED CONFINED OP (bar) Zoning Distance (X) Under Normal Conditions (m) Zoning Distance (X) Under Adverse Conditions (m) OP (bar) Zoning Distance (X) Under Normal Conditions (m) Zoning Distance (X) Under Adverse Conditions (m) >75 100 1.50 5.00 >75 100 2.00 6.50 >50 75 1.50 4.00 >50 75 2.00 5.50 >30 50 1.00 3.50 >30 50 1.50 4.50 >20 30 1.00 2.50 >20 30 1.50 3.50 >10 20 0.75 2.00 >10 20 1.00 3.00 >7 10 NE 1.50 >7 10 0.75 2.00 >5 7 NE 1.50 >5 7 0.75 2.00 >2 5 NE 1.50 >2 5 0.50 1.50 >0.1 2 NE NE >0.1 2 0.50 1.50 0.1 NE NE 0.1 0.50 1.50

IGEM SR 25 Primary Releases (Ideal) Zone 2 Zone 1

IGEM SR 25 Calculation of release dispersion calculations Information needed Vent diameter Ideal / no ideal Height of vent Length of vent Distance to nearest building

Secondary Release area IGEM SR 25 Secondary release example

IGEM SR 25 Primary release example Zone 2 Zone 1

IGEM SR 25 Calculation of release dispersion calculations Demonstration of the model