PROWAG/ADAAG Standards Guidance For Temporary Pedestrian Access Route (TPAR) Facilities and Devices

Similar documents
Accommodating Pedestrians in the Work Zone

ADA on Construction. Guidance for Section C Plan Preparers

Standards vs. Guidelines. Public Right-of Way Accessibility Guidelines (PROWAG)

Table of Contents. 2 Applying the Americans With Disabilities Act In Work Zones: A Practitioner Guide

Design Overview. Section 4 Standard Plans for Design. Pedestrian Access Routes. Pedestrian Access Routes. Overview. Cross Slope

Designing Pedestrian Facilities for Accessibility. Module 8 Maintenance of Pedestrian Facilities and Alternate Pedestrian Access Routes in Work Zones

ADA & Public Rights of Way

ADA Operations Contact Info

ADA PRESENTATION (CURB RAMPS)

City of East Grand Forks. ADA Transition Plan. Inventory Manual. June, 2018 DRAFT

ADA Design Overview. Section 2. ADA Design Overview. Pedestrian Access Routes. Pedestrian Access Routes. Overview

Department of Public Works Office of Disability Affairs February 23, 2017 Presented by Mark Zwoyer, PE

PROCEDURE FOR ACCOMMODATING PEDESTRIANS IN WORK ZONES FOR CONSTRUCTION AND MAINTENANCE

ADA Training Accessible Pedestrian Signal (APS) 2018 MnDOT

Proposed Language as approved by the NCUTCD on June 23, 2011, for new section on Pedestrian Channelizing Devices

ADA* for Roadway Design

COMPLETE STREETS DURING CONSTRUCTION

MUTCD Part 6D: Pedestrian and Worker Safety

Virginia Department of Transporta on Work Zone Pedestrian and Bicycle Guidance

Field guide for Accessible Public Rights-of-Way Edition

SafetyRail. Product & Compliance Guide. ADA-Compliant Pedestrian Barricade

NOT TO SCALE PUBLIC WORKS STANDARD DETAILS CURB DETAILS DATE: MARCH 2013 FILE NAME: CURB.DWG

Designing Pedestrian Facilities for Accessibility. Module 3 Curb Ramps & Blended Transitions

Paul Vraney Bureau of Project Development 02/11/2016

Field Design, Construction and inspection of ADA compliant Curb ramps. Mike Anderson City of Lee s Summit Construction Manager (816)

RC-67M has been updated to include more details to be consistent with both ADAAG and PROWAG. The following slides discusses the general notes found

Designing Accessible Traffic Signals

CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS

CHAPTER 6D. PEDESTRIAN AND WORKER SAFETY Section 6D.01 Pedestrian Considerations

2009 Manual on Uniform Traffic Control Devices

Field guide for Accessible Public Rights-of-Way Edition

DISTRIBUTION: Electronic Recipients List TRANSMITTAL LETTER NO. (17-01) MINNESOTA DEPARTMENT OF TRANSPORTATION. MANUAL: Road Design English Manual

ADA Training Standard Plans

CHAPTER 8 STAKING SIGNALS AND LIGHTING FIELD GUIDE. 8.1 Staking Traffic Control Signal Systems

CHAPTER 6H. TYPICAL APPLICATIONS

MUTCD Part 6G: Type of Temporary Traffic Control Zone Activities

ADA Operations Contact Info

ACCESSIBLE PUBLIC RIGHTS- OF-WAY FOR PEOPLE WITH DISABILITIES

Developed by: The American Traffic Safety Services Association (ATSSA) 15 Riverside Parkway, Suite 100 Fredericksburg, VA

Accessible Sidewalk Requirements

STAKING TRAFFIC CONTROL SIGNAL SYSTEMS

12A Accessible Sidewalk Requirements

Chapter 5. General Site and Building Elements

Traffic Control Inspection Checklist Segment:

Segment Number Quick Pathways Accessibility Tool. Name of Street: Segment Identification:

Edison Electric Institute. Work Zone Safety October 4-7, 2009

Traffic Signs and Markings. Instructor: Dr. Yahya Sarraj Associate Prof. Of Transportation

CURBSIDE ACTIVITY DESIGN

ADA Library Accessibility Checklist

Designing Pedestrian Facilities for Accessibility

First Annual Colorado Chapter Conference Englewood, CO. Accessible Pedestrian Facilities in the

CHAPTER 1 STANDARD PRACTICES

12A Accessible Sidewalk Requirements. 12A Protruding Objects

Scenarios. The following slides will show existing pictures that deny access, followed by a retrofitted picture that provides access.

Work Zone Safety A Look At Best Practices. AASHTO SCOTE June 6, 2016

Pedestrian Accommodation in Work Zones:

2017 Temporary traffic control guidelines for pedestrians. v.2

DEFINITIONS Activity Area - Advance Warning Area Advance Warning Sign Spacing Advisory Speed Approach Sight Distance Attended Work Space

TRAFFIC CONTROL DEVICES

REVOCABLE PERMIT FOR STREET BANNER APPLICATION PACKAGE

STREET and UTILITY REPAIRS WORK AREA PROTECTION GUIDE

Including Revision 1 dated May 2012 and Revision 2 dated May 2012

TEMPORARY TRAFFIC CONTROL

Pedestrians and Bicyclists. Bruce Friedman and Scott Wainwright FHWA MUTCD Team

Appendix Work Zone Traffic Control

City of Roseville Section 13 Design Standards. _Bikeways January 2016 SECTION 13 BIKEWAYS

Americans with Disabilities Act and Curb Ramps

Figure 3B-1. Examples of Two-Lane, Two-Way Marking Applications

PBIC Webinar. Accessible Pedestrian Signals [IMAGE] March 11, 2014, 2 pm

(This page left intentionally blank)

INDEX. Geometric Design Guide for Canadian Roads INDEX

MUTCD Part 6: Temporary Traffic Control

PLACEMENT OF SIGNS RECOMMENDED PRACTICES SUB-SECTION

PART 6. TEMPORARY TRAFFIC CONTROL CHAPTER 6A. GENERAL

IMPLEMENTATION. PEDESTRIAN USERS (Continued /) A: Class 2 Pedestrian / Cycle Ways. Pedestrian and Cycle Ways:

PEDESTRIAN CROSSING TREATMENTS

Application for Temporary Street/Sidewalk Closure Permit

CONSTRUCTION ENCROACHMENT PERMIT APPLICATION AND PROCESSING INSTRUCTIONS

DETECTABLE WARNING SURFACES SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS ON PEDESTRIAN ACCESS ROUTES:

Curb Ramp Guidelines. October Version 1.0

Traffic Engineering and Highway Safety Bulletin Accessibility Compliance for Military Installations

Off-road Trails. Guidance

MANUAL OF TEMPORARY TRAFFIC CONTROL ON CITY STREETS

Complete Streets Design Considerations. Second Street Corridor Complete Streets Workshop and Assessment Manchester, NH April 26, 2013

Preparing a Curb Ramp Project. December 15, 2010

Small. Regulation Reference: (see page 23 for link to the regulation)

Traffic Management Guidelines for Structure Rehabilitation Projects

Quality. Standards. Methods to determine whether the various traffic control devices are Acceptable, Marginal, or Unacceptable.

ROUNDABOUTS/TRAFFIC CIRCLES

6. UNIVERSAL PEDESTRIAN ACCESS

Temporary Traffic Control for Highway Work Zones

CHAPTER 6H. TYPICAL APPLICATIONS

2014 FHWA Aging Road User Handbook. Recommendations to Accommodate Aging Pedestrians. Lifesaver National Conference. What is the Handbook?

CHAPTER 16 PEDESTRIAN FACILITIES DESIGN AND TECHNICAL CRITERIA TABLE OF CONTENTS

NO LATER THAN ONE WEEK BEFORE YOUR PROPOSED CLOSURE START DATE

PEDESTRIAN ACCOMMODATIONS DPS 201 AT ROUNDABOUTS

Chapter 17. Work Zone Management. 17 Work Zone Management

Designing for Individuals who are visually impaired or blind

GENERAL. 1. Description

Complete Streets and the Americans with Disabilities Act (ADA) Jennifer E. Ruley, PE Active Transportation Engineer Louisiana Public Health Institute

Transcription:

INTRODUCTION: PROWAG/ADAAG Standards Guidance For Temporary Pedestrian Access Route (TPAR) Facilities and Devices Minnesota Department of Transportation DRAFT Document DRAFT This document was developed to identify and compile the various standards for components within a ADA Compliant facility. These basic features, with recommended design dimensions and preferred characteristics, will provide a guideline for determining when a pedestrian route is up to Pedestrian Access Route (PAR) standards. In this draft format, this document has NOT attempted to develop any definitions of compliance levels such as maximum extend feasible or as closely as physically and practically possible, or other such phrases used in this document. It is anticipated that a future document will be developed to provide guidance for that engineering judgment decision. BACKGROUND: The devices and/or features that are required to provide an ADAAG and PROWAG compliant Temporary Pedestrian Access Route (TPAR) may be compared to the traffic control devices and/or features required to guide traffic through a Temporary Traffic Control (TTC) zone. The driver (or pedestrian) must be warned in advance of changed conditions and their options for alternate routes. When they approach the work area, they must be given guidance on any changes from the normal route such as lane changes (or shifts in the walkway alignment). As they pass by the work area, their route must be clearly marked, be provided with a suitable surface, and they must be protected from other traffic and work operations including drop offs. Upon exiting the work area they must be guided back to their original route and/or given information on how to proceed. The various devices and/or features must be installed in a uniform manner to provide a consistent accessible route for disabled pedestrians. National ADAAG and PROWAG standards should be followed when designing a TPAR facility to ensure that uniform features and conditions are anticipated by disabled pedestrians. TPAR Component Standards The following standards have been compiled from the ADAAG (ADA Accessibility Guidelines updated 2002), PROWAAC (Accessible Public Rights of Way Planning & Designing for Alterations Special Report July 2007), and the FHWA (2009 Federal MUTCD Part 6 Standards and Guidance for Pedestrian & Worker Safety and TTC Devices). Mn/DOT interpretations are marked in the following text (shown in italics) where guidance was needed to apply ADAAG and PROWAG standards to a temporary situation. The use of shall, should and may in this document follows Mn/DOT s policies. Many statements in this document use should, meaning that the condition is highly recommended to be followed as closely as physically and practically possible. In this DRAFT document, some questions still remain on how to interpret the ADAAG & PROWAG Guidelines, and it is likely that changes will occur as these guidelines get further clarification. As we develop this guideline we welcome comments and suggestions to help clarify the needs of the disabled pedestrians. Page 1

TPAR WALKWAYS and RAMP SECTIONS TPAR Walkways may consist of a combination of existing surfaces, improved surfaces or portable devices covering existing surfaces. Whether the walkway has been modified or not, it should remain free of tripping hazards or other objects protruding into the PAR clearance area (see Figure D below). Surface: Shall be installed or improved to firm and stable condition Slip resistant (0.6 min. static coefficient of friction and 0.8 min. for ramps) Shall be designed so that water will not accumulate on walking surfaces Width: 60 or greater recommended and 48 minimum (PROWAG). Passing Spaces: Required if TPAR walkway is less 60 wide Locate every 200 feet max 60 x 60 min rectangular area Transition Joints: Should be smooth between changes in surface materials and grades Non avoidable bumps should be less than 0.5 high Vertical edges allowed up to 0.25 max Edges between 0.25 to 0.5 shall be tapered 1:2 Non-smooth joints should have contrasting marking Grades: Should be flatter than 20:1 with cross slopes flatter than 50:1 Ramps: Landings: Any section of a walkway with grades steeper than 20:1 is considered a ramp. Ramp sections shall not rise greater than 30 without a landing Required at both ends of all ramp sections Should be 60 min level length and width of adjacent ramp or greater 40 foot maximum spacing (length of ramp) if slope is between 20:1 and 16:1 30 feet maximum spacing (length of ramp) if slope is between 16:1 and 12:1 Turning Areas: Recommend 60 x 60 rectangular area Alternative turning areas are shown in Figure B. Detectable Edging: Should protrude 6" min. above walkway surface 1.5" max. space is allowed between the surface and the edging Should be firmly attached to ground or other devices Detectable edging also provides edge protection. Edge Protection: Ramps and landings with drop offs shall have curbs, walls, railings, or projecting surfaces that prevent people from slipping off the ramp. Edge side-slopes steeper than 3:1 or higher than 6 should be treated as a drop-off condition. Edge protection curbs shall be a minimum of 2 high. Refer to Figure A for an example of edge protection. FIGURE A. Example of Handrail, Detectable Edging and Edge Protection Placement Page 2

FIGURE B. Minimum widths of alternative turning configurations for wheelchair accessibility TPAR HANDRAILS vs. GUIDERAILS Handrails are only required to assist ambulatory-disabled pedestrians navigate steep grades along walkways as per the standards listed. Guiderail devices are different from Handrails, as described below, and are NOT intended to provide the required support as specified for handrails. HANDRAILS: TPAR Ramps rising greater than 6" or longer than 72" should have handrails on both sides. Handrails should be mounted between 34 to 38 above the walkway surface (to top of rail), maintain 36 min between the handrails, and should have a clearance of 1.5" min behind and 18" min above. The front face of the handrail should be aligned within +/ 4 of the detectable edge face. Handrails should have a width between 1.25" to 1.5" and be a graspable cross section. Handrails shall not rotate within their fittings, and it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in. Handrails should have a continuous gripping surface, but when handrails are not continuous, they should extend 12" min beyond the end of ramps. On switchback or dogleg ramps the inside handrail shall be continuous. Handrails should be parallel with the walkway surface and have rounded ends or turn towards the ground, wall or post. The structural strength of handrails, fasteners, and mounting devices shall meet the following specification: o Bending stress in a handrail induced by the maximum bending moment from the application of 250 lbf shall be less than the allowable stress for the material of the handrail. o Shear stress induced in a handrail by the application of 250 lbf shall be less than the allowable shear stress for the handrail. If the connection between the handrail and its mounting bracket or other support is considered to be fully restrained, then direct and torsional shear stresses shall be totaled for the combined shear stress, which shall not exceed the allowable shear stress. o Shear force induced in a fastener or mounting device from the application of 250 lbf shall be less than the allowable lateral load of either the fastener or mounting device or the supporting structure, whichever is the smaller allowable load. Page 3

o Tensile force induced in a fastener by a direct tension force of 250 lbf plus the maximum moment from the application of 250 lbf shall be less than the allowable withdrawal load between the fastener and the supporting structure. GUIDERAILS: Guiderails provide visual and tactile guidance to all pedestrians along a designated route, but they do not provide the support features of a handrail. General specifications for a guiderail may include: Guiderails are NOT TPAR standard devices and do not provide TPAR standards without the addition of approved detectable edging. They do NOT substitute for handrails on ramps and care must be taken to prevent pedestrian confusion. It is recommended that the use of guiderails be limited to pedestrian routes (TPAR or non-tpar) which need special guidance through turns, curves or crowd directional control. Guiderails should only be used along near level walkway surfaces, and shall NOT be used along walkways with slopes steeper than 20:1. By touch, the guiderail shall be readily distinguishable from a handrail to visually impaired pedestrians, such that it is not mistaken for a stronger handrail device. This may most readily be achieved by allowing the guiderail to be semi-flexible, have a non-rigid mounting and/or be an ungraspable shape. Guiderails should have a top surface width of 0.5" min to allow the hand to feel the surface. The surface shall be smooth and free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in. Guiderails should be mounted at the same height as handrails with the same clearance considerations. Guiderails should generally be parallel with the walkway surface, but may be allowed to sag slightly between mounting locations. When a guiderail is used to guide pedestrians along a TPAR, the guiderail surface should be continuous for length of TPAR. The guiderail may be interrupted by posts or short gaps. The length of gap should not permit pedestrians to maneuver through the gap. PEDESTRIAN CHANNELIZERS Channelizing devices for pedestrians should provide understandable guidance along the intended pedestrian route. There are many different types of pedestrian channelizing devices available and each device provides the guidance through a different method. Each method is suited for various pedestrians abilities to interpret the guidance. The following listing describes the various types of pedestrian channelizing devices and who may benefit. Detectable Edging provides the channelizing for long cane users. Detectable edging used alone will provide guidance to sighted pedestrians, and visually impaired pedestrians (if high contrast colors are utilized), but may introduce a tripping hazard and has limited effect for preventing non disabled pedestrians from leaving the route. Detectable Edging specifications are listed above. TTC Barricades provide visual channelizing to non disabled pedestrians and visually impaired pedestrians (if high contract colors are utilized). See the MnMUTCD for Specifications on Type I, II or III Barricades. Page 4

NOTE: Typical TYPE III Barricades may provide adequate visual guidance, but the standard legs would present a tripping hazard and would not provide any guidance for long cane users. Longitudinal Channelizers provide visual channelizing to non disabled pedestrians, visually impaired (if high contract colors are utilized), and the long cane users (if a detectable edge is incorporated into the channelizer design). Longitudinal Channelizers may also provide a suitable mounting surface for a handrail or guiderail. See the MnMUTCD for Specifications on Longitudinal Channelizing Devices. Handrails (if high contrast colors are utilized) provide channelizing guidance to all pedestrians through vision and tactile. Handrail specifications are listed above. Guiderails (if high contrast colors are utilized) provide channelizing guidance to all pedestrians through vision and tactile. Guiderail specifications are listed above. Temporary Traffic Barriers provide channelizing benefits similar to Longitudinal Channelizers, but they must be manufactured and installed such that gaps are within specifications for detectable edging and adequate contrasting colors are provided. Pavement Markings such as crosswalk markings provide visual channelizing to non disabled pedestrians and visually impaired (if high contrast colors are utilized). Painted markings have no benefit for long cane users. See the MnMUTCD and TEM for Specifications on pedestrian markings. NOTE: Typical crosswalk locations should have detectable warnings such as truncated domes and/or APS to provide the required guidance to long cane users. TPAR CURB RAMPS Should meet standards for TPAR walkways for Surface, Width, Transition Joints and Edge Protection. Grades: 12:1 to 10:1 max slope for a max 6" rise (maximum length is 72 ) 10:1 to 8:1 max slope for a max 3" rise (steeper than 8:1 is not allowed) Landings for curb ramps should allow for a minimum of 48 of clear, near level area top and bottom of the ramp. The level area should be at least as wide as the curb ramp. Detectable edging should be continued along the curb ramp if provided on approach to the curb ramp. 3:1 or flatter side slope of ramp into existing gutter except when detectable edging or edge protection is installed 10:1 or flatter side slope cut into upper walkway area (not shown on diagram). This is the standard flare slope for permanent curb cuts, but should be followed for any short slope approach area. Do not restrict gutter water flow (consider duration and location of catch basins) Detectable Warnings: Only ramps leading into traffic shall be equipped with detectable warnings such as truncated domes. Refer to the information on detectable warnings. NOTE: This needs clarification, but it appears the presence of truncated domes should indicate that a traffic lane exists immediately beyond the domes and should not be used where the pedestrian is protected from traffic. Page 5

Handrails on curb ramps are NOT required unless: Curb ramp is part of a TPAR Walkway requiring handrails. Curb ramp exceeds 6 rise and 72 length standards. FIGURE C. Typical layout and profile views for temporary curb ramp, detectable edging, portable walkway, landings and detectable warning on a TPAR facility. TPAR DETECTABLE WARNINGS When a walkway crosses or adjoins a vehicular way, and the walking surfaces are not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas shall be defined by a continuous detectable warning 36 min wide. NOTE: 36 wide truncated dome section??? We need clarification on how to interpret this requirement. Is width considered as a stripe placed laterally across a walkway, or as the width of a stripe placed longitudinally alongside a walkway? This was taken from ADAAG 4.29.5 Detectable Warnings at Hazardous Vehicular Areas. When raised truncated domes are utilized as detectable warnings, they shall have a diameter of nominal 0.9, a height of nominal 0.2 and a center to center spacing of nominal 2.35 and shall contrast visually with adjoining surfaces. The material used to provide contrast shall be an integral part of the walking surface. When the truncated domes will not be permanently installed, it is recommended that orange or fluorescent orange color be utilized. Page 6

TPAR INFORMATIONAL DEVICES When existing pedestrian accessible routes (PAR) are disrupted, closed, or relocated in a TTC, maintaining a detectable, channelized TPAR close to the original PAR alignment is much more useful to pedestrians who have visual disabilities than detouring a walkway especially when the TPAR may involve additional traffic crossings or a complex route. When rerouting is necessary, information shall be provided to all pedestrians that clearly directs the pedestrian along the TPAR, and guides them to return to the original PAR. In addition to the informational devices, a barrier that is detectable by a person with a visual disability traveling with the aid of a long cane shall be placed across the full width of the closed walkways. When TPAR compliant channelizing devices alone cannot make an modified pedestrian route evident to pedestrians with visual disabilities, then the most desirable way to provide TPAR information is with an audible information device. For pedestrians with visual disabilities an audible information device is equivalent to visual signing for notification of sidewalk closures. Devices that provide speech messages in response to passive pedestrian actuation (such as motion sensitive) are the most desirable. Other devices that continuously emit a message, or that emit a message in response to use of a pushbutton, may also be considered for sight specific conditions. If a pushbutton is used to activate the device, the device should be equipped with a locator tone to notify pedestrians with visual disabilities that a special accommodation is available and to help them locate the pushbutton. Information can also be transmitted to personal receivers, but currently such receivers are not likely to be carried or used by pedestrians with visual disabilities in TTC zones. Audible Message Device (AMD) Features: (preliminary listing) Activation: Various categories may be developed, such as motion sensitive, push-button, and continuous. Color: Should contrast with typical surrounding background. This is highly recommended if the pedestrian is required to find a pushbutton to activate the audible message. Weather Proof: The device should be weather proof for typical Minnesota weather conditions, including extremes in temperature, moisture and wind. Power Source: Various power source categories may be developed, including replaceable batteries, solar-charging batteries, external power feeds, or other alternatives. Message Length: The device shall provide adequate recording length for clear informational message needs. The minimum time will be determined, but assume 30 seconds min. Mounting: The device should be capable of being mounted on a standard TTC channelizing device or be integral with its own deployment system. Security: The device should be designed with theft and vandalism deterrents. Volume Control: The device shall playback the recorded message at a level that readily overcomes typical ambient sound levels such as traffic, construction and crowd noise. Volume control categories may be developed such as automatic volume control (dependent on ambient levels) and manually adjusted volume control. Note that APS systems require 5 decibels over ambient, which may also be the final spec for AMDs. Page 7

TPAR CLEAR AREA and INTRUSION PROTECTION The TPAR should protect the pedestrian from typically encountered traffic and work zone area dangers along the walkway. All pedestrians should be provided the equivalent level of safety or higher from typical walkway hazards encountered prior to the work zone conditions. The TPAR should be free of intruding objects (such as tools, materials, signs, ballast, and protruding parts of other TTC or TPAR devices) within a space as shown in Figure D. When a TPAR is established within areas previously designated for vehicular traffic, and traffic should be physically separated from the TPAR except for designated crosswalks. Longitudinal barrier such as concrete or steel barrier may be required to protect the pedestrians from adjacent roadway traffic and/or work zone construction vehicles. When barriers are provided, they shall not protrude into the pedestrian clear area. Temporary barriers and barricades may be utilized as longitudinal channelizing devices if they meet standards for the clear area, and detectable edging if needed. FIGURE D. Pedestrian Clear Area Page 8

PRELIMINARY LISTING of TPAR and Non TPAR DEVICES and DRAFT PAY ITEMS Approved Product List (APL) Category: Temporary Pedestrian Access Route (TPAR) Devices Product Description: Pay Item Name: Unit: Temporary Walkway Surface TPAR Walkway foot only length required to improve surface to TPAR standards Detectable Edging TPAR Edging foot may be incidental with other devices Product spec includes rigid support and mounting system Options: Approved as a Guiderail Handrail TPAR Handrail foot Product spec includes rigid support and mounting system Options: Detectable Edging may be included Temporary Ramp Panels TPAR Curb Ramp each Options: May be supplied with or without Detectable Warnings (incidental to ramp) Detectable Warning TPAR Warning foot or each? Currently this only includes Temporary Truncated Domes Audible Message Device TPAR Audible each List Available Options: Activation methods Power Source Max Message length Volume control APL Category: Pedestrian Channelizing Devices Product Description: Pay Item Name: Unit: Guiderail Guiderail foot (may be incidental with other devices) Product spec includes support and mounting system Pedestrian Signs Temporary Ped. Sign sq. foot (may be included with other signage) Longitudinal Channelizer Longitudinal Channelizer foot Options: Approved as Detectable Edge Approved as Handrail Approved as Guiderail Approved as TTC Barrier Page 9