Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Similar documents
Johnston Invar Coupling Johnston Invar Coupling

DTG - LCD Digital Temperature Gauge USER MANUAL

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

MoveRoll Conveyor Operating and Maintenance Manual

Quick Installation Guide Doc nr.: C Date:

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

OEM Manual. MODEL ½ Digit DRUM SCALE

Ultrasonic level transmitter and indicator

UltraMaxO OXYGEN ANALYZER OPERATING MANUAL & INSTRUCTIONS FOR USE R221P11. R221M11 Rev. C

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Installation and Operation Manual

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Operation and Maintenance Manual

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Jerry Martin s Co 2 Snow Apparatus

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Instruction and Maintenance Manual

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

Product Manual. Cyl-Tel and Tank-Tel Liquid Level Gauges. Designed and Built by: Chart Inc th Street NW New Prague, MN USA (800)

Technical Data Sheet MF010-O-LC

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Precision Liquid Settlement Array Manual

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Operating instructions Binary level sensor LI / / 2013

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

GasLab SAN-102 Micro Oxygen Monitor User Manual

100C Air Compressor Kit

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Over 20,000 Strain Gage Target flowmeters installed since 1952.

IMPORTANT SAFETY INSTRUCTIONS

OC Panel High Limit Aquastat Kit, Manual Reset p/n

GasLab SAN-102 Micro Oxygen Monitor User Manual

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

AUTO PUMP STATUS CENTER

ACV-10 Automatic Control Valve

User Manual PTW-DensiX. D / Di/Zi

HI 2314 HI 2315 HI 23151

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Digital pressure gauge Model CPG500

Instruction and Maintenance Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Digital pressure gauge Model CPG500

Operating Instructions MANUAL. KIT DKU 4.0 and Accessories

200 PSI COMPRESSORS - MODEL NUMBERS

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

P499 Heavy Duty Pressure Transducer

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

MEDICAL EQUIPMENT CATALOG

MANUAL GAS MANIFOLDS

Liquid Gas Cylinder (LGC)

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Expert Hydrostatic Level Transmitters

Feltest AirSpeed/2 Instruction manual

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

0RGHO /6 /6/6/6 /LTXLGÃ/HYHOÃ(TXLYDOHQWV

Selecting the right pressure sensor for your application

Sensoric 4-20 ma Transmitter Board Operation Manual

Manual Actuated Boiler Blowdown Valves

AUTOMATIC GAS MANIFOLDS

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Model PSI Compressor with 3-Gallon Air Tank 12VDC

AMT-Ex Dewpoint Transmitter

AUTOMATIC HOSE TEST UNIT, TYPE SPU

RAM 4021-DPX Operation Manual

RAM Operation Manual

Operating instructions Capacitive sensors KG AC (M18) / / 2010

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

490 Micro GC Site Preparation Checklist

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

SAUTER FK Version /2016 GB

TH-1800-T TRX-700-CNG Converter

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

444C DUAL PERFORMANCE VALUE PACK

DPC-30 DPC-100. Reference Manual

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

TECH TIPS TZ34/20 & TZ50/30. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench.

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

Precision pressure sensor Basic version Model CPT6020

Transcription:

Operation Manual Level Sensor DC-LS-50 Rev.02 (2014.06) OL Page 1 of 8

Table of contents I. STRUCTURE OF THE MANUAL / CLARIFICATION... 3 II. SAFETY AND HEALTH CONCERNS... 4 1 INTRODUCTION... 5 1.1 Use of the DC-LS-50 Level Sensor... 5 1.2 Assembly location... 5 1.3 Project number... 5 1.4 Front panel with loop indicator and front key... 5 2 TECHNICAL DETAILS... 6 2.1 Sensor... 6 2.2 Display... 6 2.2.1 Status Indication - Display... 6 2.3 Remote connection... 6 3 START UP... 7 4 ADJUSTMENTS... 7 4.1 Adjusting the level indicator (Empty 0% and Full 100%)... 7 4.2 Empty at 0%... 8 4.3 Full at 100%... 8 5 MAINTENANCE... 8 Rev.02 (2014.06) OL Page 2 of 8

I. STRUCTURE OF THE MANUAL / CLARIFICATION The various aspects of this manual are clearly listed here. Points of attention are marked throughout the entire manual in the following way (the interpretation is also given): HINT Offers suggestions/advice to the operator in order to perform certain tasks more easily. NOTE Points out possible problems to the operator. CAREFUL Indicates damage to the system or directly linked equipment when the operator does not carefully adhere to the procedures. WARNING Warns the operator of possible injuries if the procedures are not adhered to properly. PERIL TO LIFE The life of the operator is directly threatened. Demaco Holland bv considers the operator to be: the one who operates the machine or equipment supplied by Demaco Holland bv. WARNING The operator is responsible for the safety of any assisting employee. The operator must ensure, before starting the machine or application, that no dangerous situation can occur for the assisting employee. Rev.02 (2014.06) OL Page 3 of 8

II. SAFETY AND HEALTH CONCERNS NOTE This user manual must be read by the operator as soon as possible in order for him to become familiar with the operation of this equipment. From the point of view of injuries to the operator, specific attention is given to the dangers that can occur when using liquid nitrogen. On Demaco Holland bv equipment, where the operator may come into contact with liquid nitrogen, you can find the label as shown below. It warns the operator of the presence of coldness and it is indicated that safety glasses and gloves with wrist protection should be worn. figure 1; Safety label on Demaco Holland bv products This user manual should at least be available for consultation at the head of the department. We recommend that a copy be made of this manual inserted in plastic folders, or bound, and put on view at location with the control cabinet. We also recommend to carefully read the Demaco safety instruction Safety guidelines for working with cold media. Extensive information is provided in this manual about working with cryogenic media. A copy of the safety instruction is shipped with this delivery. Should you require more copies of this instruction in order to create a save working environment for your operator(s), additional copies can be requested from Demaco Holland bv. Contact our sales department. Rev.02 (2014.06) OL Page 4 of 8

1 INTRODUCTION 1.1 Use of the DC-LS-50 Level Sensor The DC-LS-50 Level Sensor is a very robust Level Gauge suited for cold stored liquefied gases like nitrogen, oxygen, argon, carbon dioxide and nitrous oxide. It provides an easy to mount, accurate and reliable digital liquid level indicator. The capacitance of the full stainless steel sensor increases ratio metrically with the liquid coverage and is converted into an easy to read, digital read out with 0.1% resolution. Additionally it has standard an analogue 4-20mA loop connection to be used for industrial control or remote purposes. As the unit is battery powered there s no need for any additional power or cabling. By using the 4-20mA loop the life indicator flashes and the battery is just needed to power the digital read out when required. By pressing the front key the unit measures and shows the actual level during 10s and switches off automatically afterwards. To mount the Gauge on a tank, a few commonly used fittings are available, the probe diameter is 12mm. Please provide exact (internal) tank size and fitting dimensions when ordering. Three push buttons are provided for an easy and clear access to electronically stored settings. 1.2 Assembly location For safe operation of the DC-LS-50 Level sensor the following points must be taken into consideration: Easy to access. Easy to read (not in direct sunlight). Adequate space to operate and maintain. Not exposed to vibrations and shocks. 1.3 Project number The project number sticker has been affixed on the back of the housing, which specifies the project number. 1.4 Front panel with loop indicator and front key Front key Loop indicator Cable connector figure 2; Front panel. Rev.02 (2014.06) OL Page 5 of 8

2 TECHNICAL DETAILS 2.1 Sensor - Material stainless steel 304 / 316 - Diameter 12mm - Length according to tank size - Temperature -200ºC... +100ºC - Maximum Pressure 35 bar 2.2 Display - Supply 9V PP3-battery (6LR61) or 4/20mA-Loop powered - Battery life 3-5 years* at 3 times/day with an alkaline battery (500mAh) - Read out 3-digit high efficiency red LED 15mm characters - Resolution 0.1% - Reproducibility 1% - Measuring rate ca. 1/s - Temperature -40ºC... +60ºC - Dimensions ca. 100 x 65 x 40 mm - Material Polycarbonate - Ingress Protection IP65 * actual battery life depends on storage and operating temperature, time intervals, manufacturer, etc. 2.2.1 Status Indication - Display - Low battery voltage < 6.5V [bat] during 2 seconds preceeding level indication - Underload level < 0% [ul ] - Measuring range level 0-100% [ 0.0]-[100] - Overload level > 105% [105]-[900] 2.3 Remote connection - Type 2-wire 4/20mA current loop - Voltage 8... 30Vdc - Accuracy 0.5% (0.08mA) Rev.02 (2014.06) OL Page 6 of 8

3 START UP Check the size of both sensor and tank to ensure they match. Try to avoid the presence of any (humid) air near cold surfaces. Any condensation of especially water inside the sensor tube will strongly increase the identification or even change to an overload situation [ol]. Position the sensor at the correct height and orientation and fix the sensor by tightening the fitting. Ensure the breathing hole of the sensor is always underneath the fitting. Pressurize the tank and check for eventual leakages. Connect the level sensor cable to the level sensor. Fill up the tank to full and check the indicator value to be about 100%. NOTE 4 ADJUSTMENTS Underneath advanced adjustments are just for experienced users and may just be done in close cooperation with the manufacturer. 4.1 Adjusting the level indicator (Empty 0% and Full 100%) Empty and Full are adjusted independently. By leaving it for 5 seconds, the unit switches off automatically without changing stored data. Jumper Buttons figure 3; Level indicator without front cover. Rev.02 (2014.06) OL Page 7 of 8

NOTE Changing of below adjustments is only enabled by placing the jumper at lowest position! 4.2 Empty at 0% Remove cover Push ENTER-button (middle) => [ 0.0] Push MINUS-button (left) => [CAL] Push MINUS-button (left) => [Lo.] Push ENTER- button (middle) => [ 0.0] 4.3 Full at 100% Push ENTER-button (middle) => [ 0.0] Push PLUS-button (right) => [CAL] Push PLUS-button (right) => [Hi.] Push ENTER- button (middle) => [100] Replace cover. 5 MAINTENANCE WARNING During some parts of this maintenance check the system must be operational. Therefore all safety requirements noted in this manual must be met. Fully check the system at least once every six months by operating the equipment and checking the following: 1. Activate display and check battery status. 2. Check all electrical connections. Connections that show signs of chafing, bare wires or other signs of wear must be replaced. 3. Report and repair any malfunction. 4. Clean the DC-LS-50 Level sensor housing periodically using a cloth. Rev.02 (2014.06) OL Page 8 of 8