The Univentor 1250 Anaesthesia Unit

Similar documents
THE UNIVENTOR 400 ANAESTHESIA UNIT

92831 TEL: (714) FAX:

Portable oxygen concentrator

In Vivo Scientific, LLC INSTRUCTION MANUAL

GasSense NDIR User Manual

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

M5400 Operators Manual

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

92831 TEL: (714) FAX:

User s Guide. CO2 & O2 Controller for miniature incubators

SPECIFICATIONS APCEPH1

WXG-4 Manual Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

MODEL 100 NITROGEN INFLATION CART

Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.:

Budget Range Operators Handbook

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

OPERATING INSTRUCTIONS V 5.3

PM105 PRESSURE METER USER S MANUAL

TrekMill USER'S MANUAL MM5050

CCT-7320/ROC-2313 Reverse Osmosis Controller

CSA Sample Draw Aspirator Adapter Operator s Manual

PERSONAL AIR BREATHING UNIT

User s Guide. CO2 Controller for miniature incubators

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

NovelBright LED Illuminator

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

DPC-30 DPC-100. Reference Manual

RoVent Jr. Automatic Ventilator Volume & Pressure Controlled. User s Guide

INFUSION SYSTEM (110V) (220V) USER S MANUAL

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

PPS PORTABLE POWER SUPPLY

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

RAM 4021 Operation Manual

Nitrogen Supply System

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

RK LEL Sample Draw Aspirator Adapter Operator s Manual

1. Connect the attached anesthesia mask to your anesthesia system using the included tubing and connectors.

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Ever. EverFlo. Home oxygen system. Oxygen simplified

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Instructions for Use

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings

UNIVERSAL MASK TEST SYSTEM

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

MODEL NUMBER: P PORTABLE COMPRESSOR

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Installation, Operation & Maintenance Instructions

! Warning, refer to accompanying documents.

Instruction and Maintenance Manual

PH01 Perfusion Cannula Manual

Roller AC Servo System

Operating Instructions Part No

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Digital Melting Point Apparatus

Reverse Osmosis System Installation Guide and Operation Manual.

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Digital Vacuum Regulator

SP-110 Autopilot OPERATION

ACCU-MIX 1200 / / 26270

OWNER S MANUAL NMB SERIES

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

Instruction and Maintenance Manual

USER MANUAL ELECTRIC BLOWBACK SYSTEM

MS-H-S10/MS-M-S10 Hotplate/Magnetic Stirrer

Digital Vacuum Regulator

Marschalk Model # 94000

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

200 PSI HIGH-FLOW AIR SOURCE KIT

Model 405 &407 Small Animal Ventilator. User Manual v3.5

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

USER MANUAL. JET TST and JET TST S.

USER MANUAL

AA GWR Water Retention Meter for Accurate Measurement of Water Retention

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Vers Gas Generator. Release III INSTRUCTION MANUAL. Advanced Calibration Designs, Inc.

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

KERN EG/EW Version /02

Qi Litre Ultrasonic Cleaner

Accu-Tab Systems 1000 Series by Axiall Corporation

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

A4s Operation Manual

Overview. Front Panel: Keypad and Display

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

AHE58/59 AC Servo System

Introduction INDEX. INTRODUCTION HSE

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

Transcription:

THE UNIVENTOR 1200/1250 ANAESTHESIA UNIT The Univentor 1250 Anaesthesia Unit

TABLE OF CONTENTS EDITION 1 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2 - INTRODUCTION 2.1. INTRODUCTION 3 Section 3 - GENERAL 3.1. UNPACKING & INSTALLATION 4 3.2. POWER SUPPLY 4 3.3. CONTROL PANEL 4 3.4. DISPLAY 5 3.5. SAFETY FEATURES 5 Section 4 - OPERATION 4.1. INSTRUCTIONS 5-7 Section 5 - ROUTINE MAINTENANCE 5.1. CLEANING 8 5.2. REPLACING PARTS 8 5.3. STORAGE 8 5.4. TROUBLE SHOOTING 8 Section 6 - SPECIFICATIONS 8-9 Section 7 - ACCESSORIES & REPLACEMENT PARTS 9 INDEX 10 1

1.1. WARRANTY Section 1 - WARRANTY & SERVICE Univentor Ltd guarantees all components of the 1200 and 1250 Anaesthesia units to be free from defects of material and workmanship for a period of two years after initial purchase. Univentor will repair or replace, at its discretion, all defective components during the aforementioned warranty period. For warranty service or repair, all Univentor s products must be returned to Univentor or to an authorised Univentor representative. The client is responsible for shipping charges to Univentor. The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the client, unauthorised modification or misuse, operation outside of the environmental specifications for the product, or improper site preparation or maintenance. For any product expressly covered under this warranty, Univentor is liable only to the extent of replacement or repair of the defective items. Univentor shall not be liable for any personal injury, property damage, or consequential damages of any kind whatsoever. The foregoing warranty is in lieu of all other warranties of merchant ability and fitness for a particular purpose. 1.2. DAMAGED SHIPMENTS Damage to any part of this instrument during shipping should be reported immediately to Univentor or an authorised representative. You must retain the original packing box and contents for inspection by the freight handler. Univentor will replace any new instrument damaged in shipping with an identical product as soon as possible after the claim filing date. Claims not filed within 30 days after the shipping date will be invalid. Do not return damaged goods to Univentor without first contacting Customer Service. All correspondence and returns must include the serial number of the instrument. Univentor refuses all unauthorised return shipments. 1.3. SERVICE Univentor has a skilled service staff available to solve any technical problem. Following discussion of your specific difficulties, an appropriate course of action will be described and the problem resolved accordingly. Service is treated as a priority and turnaround time is kept as short as possible. All correspondence and shipments should be sent to Univentor Ltd or your Univentor representative and must include the serial number of the instrument. For further details contact Univentor or Univentor s representative. 2

2.1. INTRODUCTION Section 2 - INTRODUCTION The Univentor 1200 and 1250 Anaesthetic instruments are specifically developed for lengthy inhalation anaesthesia for small animals weighing from 20g to 500g. The instruments produce an anaesthetic gas by vaporizing liquid anaesthetic in air, which is delivered by an internal pump, and enables the addition of an external gas to be accurately mixed. The 1250 has the additional benefit of an incorporated dehumidifier to reduce the relative humidity if required. The design enables low and constant gas flows which dramatically reduce the anaesthetic consumption benefiting the user, animal and environment. Whilst reliability and safety features have been incorporated we recommend continuous monitoring of the anaesthetised animal and we urge you to read this manual. LIQUID CANNULA LUER LOCK GAS OUTLET HUMIDITY LEVER LIGHT INDICATOR HUMIDITY CHAMBER ALERT KNOB HANDLE SYRINGE PUSHER AIR FILTER MAINS CONNECTOR ON/OFF BUTTON FIGURE 2.1. - The Univentor 1250 Anaesthesia Unit 3

Section 3 - GENERAL 3.1. UNPACKING AND INSTALLATION Remove the instrument from the shipping packaging and inspect both the instrument and the packaging for any signs of damage. If any damage is noted, contact the freight handler and your Univentor representative immediately, see section 1.2. Missing items? Your 1200/1250 Anaesthesia Unit is delivered with: 1. 10 ml gas-tight syringe 2. 1 m PVC tubing 3. 1 m tubing for gas inlet 4. luer-lock with tubing to be used to fill syringe 5. container with silica gel for dehumidifier (for the 1250 only) 6. power supply 7. mains lead 3.2. POWER SUPPLY MAINS - Use an earthed wall plug and the power supply supplied with the 1200/1250 Anaesthesia Unit. The power supply can automatically handle input voltage in the range from 100V AC to 240V AC, 50 to 60 Hz. BATTERY 11.85V - 13.2V. Consumption: Normal delivery - 350mA, Fast feed - 600mA. 3.3. CONTROL PANEL FUNCTIONS FAST FEED moves syringe pusher upward moves syringe pusher downward SET increases liquid flow rate decreases liquid flow rate START/STOP starts/stops liquid delivery AIR KNOB increases air flow decreases air flow GAS KNOB increases percentage of added gas decreases percentage of added gas GAS INLET ALERT connects external gas set to warn almost empty syringe FIGURE 3.3. - The control panel of the Univentor 1200 Anaesthesia Unit. 4

3.4. DISPLAY Display Mode Units Definition Min Max GAS - % % of added gas 10 99 OUTPUT FLOW - ml/min combined gas flow rate 50 999 ANAESTHETIC Standby ml/hr liquid flow rate 0.4 10 Running % % concentration 1 5 RH - % relative humidity of 1 100 output flow 3.5. SAFETY FEATURES The light indicator turns red and when in running mode an audible alarm is triggered should any of the following occur: 1. The syringe is empty 2. The output gas flow is blocked 3. The output gas flow is below 50mL/min 4. The output gas flow is above 999mL/min 5. The liquid delivery is stopped 6. The syringe has reached set alert position 7. The external gas pressure is higher than 2 bar 8. The external gas is below 10% Unless immediately adjusted the user is directed to press any key in order to view corrective action/instructions on the display. If in Standby mode for more than one hour the unit goes to Sleep mode, the light indicator turns orange and the air pump is switched off. Pressing any button will resume the Standby mode. In case of mechanical failure the unit will shut down to protect itself. Section 4 - OPERATION HANDLING OF ISOFLURANE AND/OR ANY OTHER CHEMICAL SHOULD AT ALL TIMES BE IN COMPLIANCE WITH THE MANUFACTURER S INSTRUCTIONS AS WELL AS REGULATIONS APPLICABLE TO YOUR COUNTRY. USE ONLY A 10mL GAS-TIGHT SYRINGE WITH A 60mm STROKE. MONITOR ANIMALS AT ALL TIMES. 4.1. INSTRUCTIONS All anaesthesitising parameters are stated as a guideline only due to variations in animals and procedures. 5

4.1.1. SETTING UP Connect the instrument to the power supply and earthed mains and switch on. 4.1.2. AIR FLOW Set the air flow, minimum 50mL/min and maximum 999mL/min, by turning the AIR KNOB. Output flow is displayed in ml/min. Mice - approximately 150-250mL/min Rats - approximately 400-500mL/min 4.1.3. LIQUID ANAESTHETIC Set the liquid anaesthetic concentration percentage by pressing SET buttons. Display will show the percentage while pressing SET buttons and the liquid flow rate when the buttons are released. Use the liquid flow rate to calculate the duration of the syringe: syringe content ml anaesthetic flow rate ml/h = available time e.g. With 10mL liquid anaesthetic in the syringe and set flow rate 1.5mL/hour the available time will be 6.666 hours. (6 hours and 40 minutes). Maintenance concentration - approximately 1.7-2.5% Induction chamber concentration - approximately 4% The concentration is calculated using the gas output flow and anaesthetic delivery. 4.1.4. SYRINGE ALERT To ensure that a warning is sounded before the syringe is empty, determine the desired warning time in minutes and calculate the liquid volume (V) that this is equivalent to, by using the following formula: V = liquid flow rate (ml/h) x desired warning time (min) 60 Turn the ALERT KNOB all the way anti-clockwise and fit empty syringe refer to 4.1.6. FITTING SYRINGE. Use upward button until the plunger has reached the corresponding reading on the syringe. NOTE: Should any settings be changed during the experiment the warning time will change accordingly. Turn the ALERT KNOB clockwise until the display shows Close To End. When the alarm is sounded it can be switched off by pressing any button. The delivery will continue until the syringe is empty at which point another alarm is triggered and the pusher automatically reverses to release the syringe. 4.1.5. FILLING SYRINGE Follow the anaesthetic manufacturer s handling instructions and fill the 10mL gas-tight syringe using the supplied tubing. Any air in the syringe will be eliminated when fitted. 6

4.1.6. FITTING SYRINGE Fit the luer lock of the syringe with the one of the instrument. Press upward button and make sure that the plunger of the syringe is centred in the pusher when they meet. Continue to move the pusher upwards until the display reads Liquid Filled. The upward button can no longer be used to ensure that the system is not flooded. 4.1.7. EXTERNAL GAS Prior to connecting make sure that the supplied gas is delivered pulse free and at a pressure of 0.5-1 bar. Connect the tubing to the GAS INLET and set desired percentage by turning the GAS KNOB. The added gas is displayed as a percentage of the total output gas which must not exceed 999mL/min. When adding gas the output flow is increased but the anaesthetic concentration is adjusted accordingly to remain constant as per original setting. 4.1.8. CONNECTING Connect one end of the supplied PVC tubing to the GAS OUTLET and the other to the anaesthetised box, mask or ventilator. Keep tubing as short as possible. 4.1.9. HUMIDITY CONTROL - 1250 ONLY Release the chamber by pulling the handle towards you. Remove, open and fill with the supplied gel. Refit and secure by lifting the handle. The Relative Humidity is displayed and can be reduced by moving the humidity lever to the right. NOTE: Using the instrument in an environment of more than 80% RH may cause damage. The life span of the silica gel varies according to the environment and use and will turn from orange to green when no longer effective. The gel may be regenerated by heating at 100-120 C until it returns to its original colour. Regeneration may be carried out repeatedly, although eventually the crystals will lose their colour. 4.1.10. START DELIVERY Adjust the position of the display by tilting it to ensure constant visual contact and press START/STOP to start delivery. The anaesthetic % concentration set when starting the delivery will be the default start up setting the next time the instrument is used. NOTE: Delivery can be instantly terminated by pressing START/STOP to stop the instrument. However, in case of emergency remove the mask, due to gas in the outlet tubing. DO NOT STORE ANAESTHETIC IN SYRINGE WHEN NOT IN USE 7

Section 5 - ROUTINE MAINTENANCE 5.1. CLEANING THE INSTRUMENT 1. After every use stop the liquid delivery and allow the air flow to continue for a period of 15 minutes to dry any remaining liquids 2. Keep your Anaesthesia Unit clean 3. DO NOT STORE ANAESTHETIC IN SYRINGE WHEN NOT IN USE 5.2. REPLACING PARTS We recommend that the following parts are changed at least yearly or as necessary according to use: Outlet Filter 2423017 Air Filter 2436132 5.3. STORAGE If the Univentor 1200/1250 Anaesthesia Unit is not to be used for a significant length of time, it is recommended to clean the instrument, fit protective covers on inlet and outlet and store it safely in the shipping box. 5.4. TROUBLE SHOOTING 1. Display shows Slip Error Occurs when force exceeds 100N due to: a) Jammed pusher make sure clear b) Blocked syringe and/or tubing check and replace as necessary c) Blocked liquid cannula change part number 2436032, or contact Univentor or your Univentor representative d) Mechanical malfunction contact Univentor or your Univentor representative Section 6 - SPECIFICATIONS Power Power supply: 100-240V AC 50-60 Hz Battery: 11.85V - 13.2V. Consumption: Normal delivery - 350mA, Fast feed - 600mA Dimensions 1200 Dimensions 1250 Weight 1200 Weight 1250 Shipping weight 1200 Shipping weight 1250 172.5mm (l) x 112mm (b) x 220mm (h) 223.5mm (l) x 112mm (b) x 220mm (h) 2.2kg 3.0kg 5.0kg 6.0kg 8

Drive motor Fast feed Syringe Min. liquid flow rate Max. liquid flow rate Min. air flow rate Max. air flow rate Min. added gas pressure Max. added gas pressure Max. pusher force Pusher movement tolerance Display Safety features Pulse free DC motor with variable speed setting Pusher movement of 45mm/min Glass gas-tight 10mL syringe with 60mm stroke 0.4mL/hr 10mL/hr 50mL/min 999mL/min 0.5 bar 1.0 bar 100N +/-0.01mm or +/- 1% of total distance 2x16 characters Audible alarm and red light indicator Section 7 ACCESSORIES & REPLACEMENT PARTS ORDERING INFORMATION CAT. No. DESCRIPTION 8336000 Univentor 1200 Anaesthesia Unit 8336050 Univentor 1250 Anaesthesia Unit 2423017 Gas outlet filter 2436032 Liquid cannula 9

INDEX ACCESSORIES...9 AIR FLOW RATE...4,6,9 ALARM...5,6 ALERT...4,6 ANAESTHETIC...3,5,6 ANIMAL WEIGHT...3 BATTERY...4,8 CLEANING THE INSTRUMENT...8 CONCENTRATION - ANAESTHETIC...5,6,7 CONTROL PANEL...4 DAMAGED SHIPMENTS...2 DISPLAY...5 LIQUID FLOW RATE...5,6 MAINTENANCE AND STORAGE...8 OPERATING INSTRUCTIONS...5,6,7 OPERATING TIME...6 PACKING LIST...4 POWER SUPPLY...4,8 REPLACING PARTS...8,9 SERVICE...2 SPECIFICATIONS...8 SYRINGE...4,5,6,7,8 TOLERANCES...9 TROUBLE SHOOTING...8 UNPACKING AND INSTALLATION...4 WARRANTY...2 10

B29, Bulebel Industrial Estate, Zejtun ZTN 3000, Malta. Tel: (+356) 21 895824. Fax: (+356) 21 895835. E-mail: info@univentor.com Homepage: http://www.univentor.com