TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

Similar documents
Steel Spring Driven Reel Instruction Manual

30T A/Manual Hydraulic Shop Press

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Manual Actuated Boiler Blowdown Valves

80 Litre Suction Oil Drainer

MAINTENANCE PROCEDURE FOR X 650

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

KTM 50 (DN ) Installation, maintenance and operating instructions

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Rubber Dock Hose care, Use & Maintenance

PRESSURE ADJUSTMENT Main pressure adjustment

Booster Pump PB4-60 Replacement Kits

Retractable Hose Reel with 3/8" x 50' PVC Hose

75 Ton SD Shop Press Operating Instructions

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

HYDRAULIC PALLET TRUCKS. MODEL Nos: PT550BC, PT685BC, PT550NC, PT685NC OPERATION & MAINTENANCE INSTRUCTIONS

III. Identify the initial installation requirements for standpipe systems

System Pressure Manager Standard & System Pressure Manager Plus

Hydrostatic Pressure Testing

PV4 and PV6 Piston Valves

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

Pressure Dump Valve Service Kit for Series 2300 Units

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

WIDDER TOOLS. HPICAL Calibration Station 1 (203)

20 Ton SD Shop Press Operating Instructions

AUTOMATIC GAS MANIFOLDS

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

PACKSETTER HAND PUMP

Operation and Maintenance Instructions

INSTALLATION & MAINTENANCE INSTRUCTION

Warning: NEVER ALTER TEST EQUIPMENT

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

TOOL BOX 031- SERVICE OF CARTRIDGE EXTINGUISHERS

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Operating Instructions Models and Hydrostatic Test Pumps

ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

HYDRAULIC MOBILE LIFTING TABLE

LIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS

VL 2K LIFT D-L WINCH INSTRUCTIONS (Applies to P/Ns , , , , , )

PUNE TECHTROL PVT LTD. Instruction and Maintenance Manual for Float and Tape Gauge FTG

LIQUID LEVEL GAUGE FOR WELDING ZGAU 716 O&M, 717 O&M, 718 O&M, 719 O&M

Bermad Pressure Reducing. Model: 42T

Medical Gas Control Panel

641/01 AVK SWING CHECK VALVE OPERATION & MAINTENANCE MANUAL. AVK UK Limited OM270710

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

ambiente Installation Guide AmbiClip Systems more than underfloor Customer: Project: Project Reference: Date:

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

APT14, APT14HC and APT14SHC Spares 2

Pressure Dump Valve Service Kit for Series 3000 Units

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

Spare parts list ( ) Spare parts list HD 2.3/14 C Ed Food

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Hose Reel Instruction Manual

CS150 CAP STAPLER OWNER S MANUAL

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

MANUAL GAS MANIFOLDS

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

OPERATION and MAINTENANCE Guide

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

SECTION 2 RING MOUNT

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

TECHNICAL DATA. than the water inlet pressure to the concentrate

200 PSI COMPRESSORS - MODEL NUMBERS

VB85/ Pressure regulating valve (Unloader)

Spare parts list. ( ) Spare parts list HD 3.0/20 C Ea

AIR/OVER HYDRAULIC JACK 20 TON

3/8" KEYLESS REVERSIBLE AIR DRILL CT1086

SEries 29 Hydrant valves installation, operation & maintenance manual

RST INSTRUMENTS LTD.

DM-RD (English) Dealer s Manual. ROAD Rear Derailleur RD-9000 RD-6800 RD-5800 RD-4700

Supplementary Operation, Assembly, Maintenance Manual for F3-42 model and optional attachments

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

OPERATIONS/PARTS MANUAL FOR PATTERSON'S WWP40M-12 and all WIDE DRUM variations of this HAND OPERATED WINCH.

Spare parts list. ( ) Spare parts list HD 3.0/20 C Ea

IMPORTANT SAFETY INSTRUCTIONS

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

GREIG FILTERS, INC. OPERATION MANUAL

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

WHEATLEY Series 500 Swing Check Valve

S & M Water Consultants

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

Transcription:

In SANS 10105 you will find the Minimum water pressure for both the hydrant and the hose reel. Which is 300KPA Manufacturing Standard SANS 543 1 Front & Back plates 2 Curved Plate 3 Waterway assembly 4 Washer 5 Nut 6 Bolt 7 Back plate Plastic Bush 8 Pop rivets 9 Header Bracket 10 Front plate mounting screws 11 Hose Run off shackle 12 Instruction Label Theory and Practical Maintenance of hose reels Page 6 of 18

Risk Assessment: Is there any electrical cables and / or electrical machinery near the reel. If Yes REPORT TO THE RESPONCIPLE PERSON and do not service. Task Procedure 1. Check last service date and still sealed 2. Check general condition and security 3. Check arrow direction on CP Valve Pointing towards reel. This is a one way valve 4. Open water supply and check for leaks. Ensure Nozzle in closed Position Run out hose checking for damage to the shackle and hose such as cuts cracks kinks, and that the length is no longer than 30metres and not shorter than 28metres Further check for leaks and for rusting around waterway area 5. Open nozzle check the jet range: standard nozzle not less than 5 metres 6. Turn off water and release pressure on hose. Attach service label to inside reel as closed to the waterway as possible, and roll up hose. 7. Carryout bucket. ( If you require to determine the flow rate which is 0.5ltrs per second) (Not Required by SANS 1475-2) Use Pre marked bucket at 5ltrs. Turn water on and time, and it should not take more than 10seconds which is 0.5ltrs per second. If it does not reach the timing factor repeat. If still NO remove internal service label. Roll up hose and remove external service label. Mark outer drum No Water Report to CUSTOM both VERBALLY and ON JOB CARD This is not totally accurate (pressure you would have to fit a gauge). But you can safely say that the pressure is at least 300Kpa (SANS 10105-2) Note No7 is not a requirement under SANS 1475 Part2 8. Open nozzle and bleed in an action of pumping up and down to bring water level below the waterway. (Like milking a cow). You can close or keep the nozzle open. But if you leave it in the closed position and there is a problem. The water pressure on the waterway will build up and maybe lead to further repairs required. 9. Fit seal in such a way that it will have to be broken to use the equipment. Not on the hose to CP valve. But fitted between nozzle and hose to CP Valve. 10. Fit service label to drum with the following in the full weight block Min 5 metres Questions and answers (ask student) Page 7 of 18

Fault Finding 1. No Water: During your service procedure, and you have checked the arrow direction on the Control Valve. You hear water entering the system but little or none is coming out of the Nozzle. Remove nozzle: Water flows: Unblock or Replace Nozzle. 2. Missing or broken mounting bolts: Fit missing bolt or remove frame and remove broken bolt. If there is a joint under the Control Valve you should be able to swing the reel assembly forward (remove hose to reduce weight) without switching off at the mains. If there is no joint you will have to report to the Responsible Person 3. Control Valve fitted with the arrow direction facing the wrong way: As this is a one-way valve remove all service labels and mark no water. Report to the responsible person. 4. Leaking Reel after service: In this case you may not pick up a problem during the service, and it may only appear as few days, weeks later. If you have serviced unit correctly, and the seal is not broken the problem is the Control Valve washer. This is not part of the service (Inspection only during service) Report to the responsible person. If you do intend to repair it you will have to have the water switched off at the mains. It is very important that everybody that is going to be effect with the water being switched off is informed. You should ensure that the Responsible person takes this responsibility, and not yourself or your company. Once water is off on the modern Control Valves it s as simple as changing a tap washer, and on the older type the whole unit will have to be replaced. 5. Waterway Leaks: You have two types of water ways O Ring and Gland Packing. O Ring Type: Ensure as much water has been drained A. Remove Hose. B. Remove drum and waterway assembly C. Remove the three screw from the front plate behind the instruction label D. Remove the waterway from the drum E. Remove the circlip from the recess, and pull out the shaft Page 8 of 18

F. Remove the old O rings, and clean the shaft / body G. Refit new O rings, lubricate, and refit shaft H. Refit the circlip ensuring correctly site in the grove. (failure to do this, and the drum will fly off under pressure) I. Refit waterway to the drum with the three screws J. Use thread tape for the threaded part of the shaft, and refit to the header bracket K. Refit hose, and slowly open the Control Valve. At this stage there will be a slight leak until the waterway has bedded in. Once leak has stopped close the Control Valve and release the water pressure. Repeat, and ensure leaks have stopped. Carry on and complete the service> Gland Packing Type: This is the old type reel that Technicians are quick to condemn, when the repair is very simple saving the Responsible person a lot of unnecessary expense. The main reason this type of reel is condemned apart from the usual rusting is the Technicians over tightening of bolts. A. While the hose is rolled down and the leak is present check the two mountain bolt plates. If they are not straight and show bending it means they have been over tightened in the past and probably they have also been stretched Result condemn. B. If they have not been stretched tighten slightly ensuring the drum still rotates freely Leak cured finish service. C. Leak continues Ensure the water is off and pressure is released. D. Remove the two bolts securing the flange E. Pull the drum forward and separate. F. Remove the gland packing, and cut a new piece to the same lengths (5mm Page 9 of 18

square graphite rope) G. Clean parts concerned wind the new gland into place, refit parts together, insert bolts and tighten evenly ensuring the drum rotates freely. H. Turn on the water pressure and check for leak IMPORTANT INFORMATION: Some buildings have their fire circuits connected to the fire department, and or the warning alarm go off once you release water from the fire protection arrangement. Also especially high rise building parts or all of the system is supplied from tank usually situated on the top of the building. Once you open a valve and release the water during testing. The pump kicks in and keeps the tank topped up. If this pump doesn t kick in you will only be getting static water pressure, and may get the readings required throughout the building. You will assume the service work is to the standards required. But in fact you have depleted the water in the tank, and should there be an incident the equipment will not work. Before you start you must pose all the above questions to the client. If you find the pump switched off or the tank inlet valve in the closed position. Ask the question why. If the answer is they do not know why Then tell them to find out before you perform any work. There might be a leak or other fault for the protection system to be switched off. If the client tells you to just turn the equipment on Refuse, and tell them they must perform this task of switching on. ( You flood the place They will hold you and your company responsible for any damage caused). Also if the alarms go off and there is a feed back to the Fire Department You and your company will be responsible for the call out fees. If at any time you switch the water supply to any fire protection equipment 1. The fire department should be informed 2. The client needs to inform the insurance company and anybody who is going to be affected by the switch off. Before a hose reel is moved or installed a design must be submitted for approval to the fire department Original fire Plans cannot be altered. SANS 10400W 4.4 Isolating valves An isolating valve shall be fitted in a fire installation at a position that is not more than 1,5m inside the boundary of the site, and shall be clearly marked as such. Not counting the feed pipe to the actual hose reel. The following applies. 1 to 2 hose reels feed 25mm 3 hose reels 32mm 4 to 5 hose reels 40mm Page 10 of 18

6 and above 50mm SANS 10252-1:2012 Water supply installations for buildings 7.2.2 Fire installations and combined installations 7.2.2.1 A water gauge pressure of at least 300 kpa at the level of the highest protected point shall be maintained when one hose reel is in full operation in any combined installation. 7.2.2.2 A fire installation or combined installation shall a) be so constructed as to provide 1) a supply of water sufficient for the effective operation of the number of hose reels and hydrants that can be operated or come into operation simultaneously in any division, and 2) a flow pressure, at any hose reel or hydrant, of at least 300 kpa and a flow rate of at least i) 30L/min per hose reel, and ii) 1 200 L/min per hydrant, and b) incorporate devices that limit the gauge pressure at any hydrant valve to 600 kpa under full flow conditions. 7.8 Fire installations and combined installations 7.8.1 General 7.8.1.1 Any fire installation or combined installation shall be the subject of a rational design. 7.8.1.2 The design shall make provision for the number of hose reels and hydrants that can be operated or can come into operation simultaneously in any division. 7.8.1.3 Unless otherwise required, fire hydrants in any building that exceed 12 m in height, or when the total floor area of the building exceeds 1 000 m 2, shall be provided on the basis of one hydrant per 1 000 m 2 of floor area for each floor or part thereof. 7.8.1.4 Hydrants, although intended for use by the fire brigade, shall be situated in suitable positions subject to direction by the local authority. 7.8.2 Pipe sizes 7.8.2.1 Pipes in any fire installation or combined installation shall be sized according to a rational design and in accordance with 7.6, where appropriate. 7.8.2.2 In any fire installation, a) the nominal diameter of Page 11 of 18

1) a communication pipe serving such installation shall be at least 75 mm, 2) a pipe supplying water to a fire hydrant shall be at least 75 mm, except that where the length of such pipe exceeds 50 m, the nominal diameter of such pipe shall be at least 100 mm, and 3) a service pipe supplying water to a hose reel on any one storey of a building shall be at least i) 25 mm, if it serves one or two hose reels, ii) 32 mm, if it serves three hose reels, iii) 40 mm, if it serves four or five hose reels, and iv) 50 mm, if it serves more than five hose reels. Finally Note: Our mandate is from above the CP Valve up, and this training in no way is authoring you to perform any type of repairs below the CP Valve.Repairs, Replacement, and installation are not sanctioned by SAQCC, and we will not be held responsible for any incident involving damage, injury or incorrect work procedures. THIS TALK HAS BEEN EXTRACTED FROM A TRAINING MANUAL See Toolbox Talk 013- Hose reel tips See Toolbox Talk 003-Hose Reels Presented By: Name: Date Signature NAME SIGNATURE NAME SIGNATURE Page 12 of 18