INSTALLATION MANUAL. M-WRG-S/Z-T(-F, -FC) and InControl pushbutton sensor

Similar documents
MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

Instruction Manual BA90 Precision Barometer

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Operating Manual VSA100A. tina29e1 ( )

T EK-SUB 4800C 19 mm Submersible Level Transmitter

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

Transmitter CS 21 Operation Manual

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Operation Manual. Hand tool for AMP DUOPLUG Customer Manual PN: en (Translation of the original German version)

DK46 - DK800 Supplementary instructions

Ultrasonic Level Transmitter

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

testo Leakage detector for refrigerants Instruction manual

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Model Visit our website at:

Instruction Manual Differential Pressure Transmitter

Norrsken Family Booklet

Type BBS-03, BBS-05, BBS-06, BBS-25

Installation and Service Manual

! Warning, refer to accompanying documents.

Sinorix MANOB480, MANOCAB, MANOEOL Installation Maintenance

AE R1 February 2015

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Standard League Robot Soccer EV3 Compass Training Curriculum Brian Thomas

Instruction Manual Contact Pressure Vacuum Gauge

LOCK UP VALVES YT-400/405/430/435 SERIES

Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.

MP15 Jockey Pump Controller

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

New AQF Filter Polymer Filtration System

92831 TEL: (714) FAX:

Transmitter CS 21 Operation Manual

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

210 Series Transmitter with External Electrochemical Sensor

Operating Instructions Temperature Measuring System MF420-5T-100

Instrument Operating Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

TR Electronic Pressure Regulator. User s Manual

Installation Procedure Esco Miri Multi-Room Incubator

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Installation and Maintenance Instruction Manual

Manual. Kingpad mc-32 Edition. Bus system control pad for installation in the Graupner mc-32 transmitter. No Copyright Graupner/SJ GmbH

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Operators & Maintenance Manual OPERATOR S MANUAL USAGE AND MAINTENANCE F100M F100M. Powered Fixed Hoist Ideal for raised swimming pools and hot tubs

Applications & Tools. Evaluation of the selection of a safetyrelated mode using non-safety-related components

BASnet LightiView Install Guide

SANP ACTING RELAYS YT-520/525/530 SERIES

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Instruction Manual. Pipe Friction Training Panel

e.do Gripper Safety requirements, technical features and assembly and integration instructions

A17W49_MASEM_F_EN MANUAL

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

INSTALLATION INSTRUCTIONS AND REFERENCE HANDBOOK

Safety. Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve VMV DANGER. Contents WARNING CAUTION

nual cylinder change-over unit N) manual Automatic gas cylinder change-over unit Operating manual

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

SM6. instructions for use. connection with compartment for incoming cable from the top. MV distribution factory built assemblies at your service

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Natural Gas to L.P. Gas Conversion Kit

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Operating Instructions in accordance with the Machines Directive 2006/42/EC

Electro-Pneumatic Converter YT-940 SERIES

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

METROTEC GSM. Type GSM. Oxygen measurement and control unit. *** Version 1.6 ***

Flowmeter. Original operating manual DFM

Guidelines to the standard IEC60601

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Z5160 Load adapter Mounting instructions (1.2 EN)

Operating Instructions of BROSA tension load cells, types 0111, 0113

Pressure maintenance valve SDV-P / SDV-P-E

USER MANUAL. JET TST and JET TST S.

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

ECL Comfort 110, application 131 (valid as of software version 2.00)

Natural Gas to L.P. Gas Conversion Kit

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

Conversion instructions from natural gas to propane

TWB Shoulder Retractors

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

STAGE, STADIUM & X-TREME SHOT.

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Application Note. Safety Sub-function PUS Category 1, up to PL c. Application Note PUS, Category 1, up to PL c M20 S22 R20 M1 Q20

J12 TICKET DISPENSER HOPPER ALL STOP STOP 1 STOP 2 STOP 3 BIG DOUBLE SMALL TAKE PLAY START CURRENT PRODUCTION BOARD TYPE

Instruction Manual Differential Pressure Transmitter

The World s Best Adductors

Batter Up & Bowl Sports Arena

Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

User s Guide Temperature Sensor Converter TSC-599

Getting to know your Sureshotgps micro V3

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Transcription:

INSTALLATION MANUAL HOME VENTILATION WITH HEAT RECOVERY and Connecting the ventilation unit to the CO ² Part no. 0-09-0 Week 0/0 EN Am Hartholz D-89 Alling

Contents Introduction.... Notes on this installation manual.... Description.... Target group.... Revision index.... Explanation of the symbols used.... Supplementary documents... Safety instructions.... Hazard classification.... Notes on using the ventilation units safely.... Intended use... Warranty and liability... Terminal assignment.... Board with terminal blocks......... Back panel with terminal blocks..... Connection diagram... Connecting one ventilation unit... 7. Connecting the to the M-WRG-S/Z-T ventilation unit... 7. Connecting the to the M-WRG-S/Z-T-F ventilation unit... 8. Connecting the to the M-WRG-S/Z-T-FC ventilation unit... 9 Connecting to ventilation units... 0. Connecting the to M-WRG-S/Z-T ventilation units... 0. Connecting the to M-WRG-S/Z-T-F ventilation units.... Connecting the to M-WRG-S/Z-T-FC ventilation units... Am Hartholz D-89 Alling - -

Introduction. Notes on this installation manual This installation manual contains important information that should be followed when connecting the M-WRG-S/Z-T, M-WRG-S/Z-T-F and M-WRG-S/Z-T-FC ventilation units to the InControl pushbutton sensor. Read all the instructions carefully before installing to avoid possible risks and mistakes. When installation is complete, give these instructions to the home owner, caretaker or property manager. These instructions are part of the product. Keep the instructions in a safe place for future reference. WARNING Follow ALL danger and warning instructions and notes on precautionary measures. Read section Safety instructions on page carefully. NOTE Also follow the M-WRG-S.../M-WRG-K... installation manual, part no. 00-0-0, for installing the ventilation units.. Description This manual describes how to connect the M-WRG-S/Z-T, M-WRG-S/Z-T-F and M-WRG-S/Z-T-FC ventilation units to the. Item Part number M-WRG-S/Z-T ventilation unit 0-- M-WRG-S/Z-T-F ventilation unit 0--- M-WRG-S/Z-T-FC ventilation unit 0--- 07-... CO ² Fig. : and board with terminal blocks in the ventilation unit Am Hartholz D-89 Alling - -

. Target group The activities described in this manual must only be carried out by technicians with the following qualifications: Training in the installation and commissioning of electrical devices Training in electrical hazards and the local safety requirements Knowledge of the relevant standards and directives Knowledge and observance of this document and all the safety instructions. Revision index Edition Manual Date st edition Installation manual Week 0/0 EN. Explanation of the symbols used This symbol indicates an action to be taken. This symbol indicates a list.. Supplementary documents Manual Part no. Installation manual M-WRG-S.../M-WRG-K... 00-0-0 Safety instructions This manual contains notes that you must follow for your own personal safety and to avoid injury and damage to property. They are highlighted by warning triangles and are shown as follows according to the level of danger.. Hazard classification DANGER The signal word designates a hazard with a high degree of risk which, if it is not avoided, will result in death or severe injury. WARNING The signal word designates a hazard with a medium degree of risk which, if it is not avoided, will result in death or severe injury. CAUTION The signal word designates a hazard with a low degree of risk which, if it is not avoided, could result in minor or moderate injury. NOTE A note as used in this manual contains important information about the product or about a part of the manual to which particular attention should be paid. Am Hartholz D-89 Alling - -

. Notes on using the ventilation units safely CAUTION Starting and using the ventilation unit. Intended use Do not start up the ventilation unit until it is fully installed. Always make sure that the cover is closed and locked in place before using the ventilation unit. The intended use includes compliance with all the notes in the installation manual. The ventilation unit must not be operated without a filter. For any use contrary to the intended use, shall accept no liability for any damage that may occur and offers no warranty that the components will work perfectly and correctly. Warranty and liability The warranty and liability shall be void if the ventilation unit or is not connected as described in this installation manual. Terminal assignment. Board with terminal blocks + IN LED OUT RJ IN LED OUT Fig. : Terminal assignment on the board with terminal blocks Am Hartholz D-89 Alling - -

Installation manual V E N T I L AT I O N & H E AT R E C O V E R Y... Back panel with terminal blocks Item Designation Terminal block for pushbuttons Terminal block for LEDs Smiley on the side of the terminal block for LEDs + 8 7 NOTE Use the smiley (item in Fig. ) as an orientation guide. It is only in this position that the connections on the terminal blocks agree with the connections identified in the connection diagram (Fig. ). 7 8 GND Fig. :.. Item Back panel with terminal blocks Connection diagram Designation Terminal block for pushbuttons Terminal block for LEDs Optional bridge for backlight NOTE The has a backlight that can be activated if required. Place a bridge (item in Fig. ) across terminals 7 and 8 of the terminal block for LEDs to supply V DC to the backlight. Fig. : Am Hartholz D-89 Alling connection diagram VENTI LATI O N TH E RI GH T WAY --

Installation manual V E N T I L AT I O N & H E AT R E C O V E R Y Connecting one ventilation unit. Connecting the to the M-WRG-S/Z-T ventilation unit Use J-Y (St) Y 0xx0. mm / J-Y (St) Y 0xx0.8 mm for the wiring. After wiring, place the insert sheet (Fig. ) in the. Terminal M-WRG-S/Z-T 7 8 9 0 7 8 Terminal blocks Pushbutton LED GND + Wire colour Function GND + V DC Reduced ventilation Normal ventilation Increased ventilation Intensive ventilation Reduced ventilation LED Normal ventilation LED Increased ventilation LED Intensive ventilation LED Supply air operation Exhaust air operation Supply air operation LED Exhaust air operation LED Table : Connecting the to the M-WRG-S/Z-T ventilation unit + 8 7 Pushbutton LED 7 8 GND Fig. : Terminal blocks on M-WRG-S/Z-T, terminal blocks on, M-WRG-S/Z-T insert sheet Am Hartholz D-89 Alling VENTI LATI O N TH E RI GH T WAY -7-

Installation manual V E N T I L AT I O N & H E AT R E C O V E R Y. Connecting the to the M-WRG-S/Z-T-F ventilation unit Use J-Y (St) Y 0xx0. mm / J-Y (St) Y 0xx0.8 mm for the wiring. After wiring, place the insert sheet (Fig. ) in the. Terminal M-WRG-S/Z-T-F 7 8 9 0 7 8 Terminal blocks Pushbutton LED GND + Wire colour Function GND + V DC Reduced ventilation Normal ventilation Increased ventilation Intensive ventilation Reduced ventilation LED Normal ventilation LED Increased ventilation LED Intensive ventilation LED Supply air operation Humidity control Supply air operation LED Humidity control LED Table : Connecting the to the M-WRG-S/Z-T-F ventilation unit + 8 7 Pushbutton LED 7 8 GND Fig. : Terminal blocks on M-WRG-S/Z-T-F, terminal blocks on, M-WRG-S/Z-T-F insert sheet Am Hartholz D-89 Alling VENTI LATI O N TH E RI GH T WAY -8-

Installation manual V E N T I L AT I O N & H E AT R E C O V E R Y. Connecting the to the M-WRG-S/Z-T-FC ventilation unit Use J-Y (St) Y 0xx0. mm / J-Y (St) Y 0xx0.8 mm for the wiring. After wiring, place the insert sheet (Fig. 7) in the. Terminal Terminal blocks M-WRG-S/Z-T-FC Pushbutton LED GND + 7 8 9 0 7 8 Wire colour Function GND + V DC Reduced ventilation Normal ventilation Increased ventilation Intensive ventilation Reduced ventilation LED Normal ventilation LED Increased ventilation LED Intensive ventilation LED Humidity control CO control Humidity control LED CO control LED Table : Connecting the to the M-WRG-S/Z-T-FC ventilation unit + 8 7 Pushbutton LED 7 8 GND Fig. 7: CO² Terminal blocks on M-WRG-S/Z-T-FC, terminal blocks on, M-WRG-S/Z-T-FC insert sheet Am Hartholz D-89 Alling VENTI LATI O N TH E RI GH T WAY -9-

Connecting to ventilation units Up to five ventilation units can be controlled with one. The following conditions must be met: The ventilation units must all be of the same type. All the ventilation units that are connected to the same should be located in the same room. If possible, the control cables should be arranged and connected in a star configuration (see Fig. 8) from the ventilation units to the. The cable between the ventilation unit and should be no more than m long. Ventilation unit (master) must always be switched on. It generates the feedback for the LED on the. Ventilation units to (slaves) only respond to switching commands from the InControl sensor. Slave Slave Slave NOTE Connect + only to the first ventilation unit (master). Connect GND to all the ventilation units (master + slaves). Master Slave Fig. 8: Connecting the ventilation units in a star configuration. Connecting the to M-WRG-S/Z-T ventilation units Terminal blocks Number Ventilation unit M-WRG-S/Z-T Pushbutton LED (master) (slave) (slave) (slave) (slave) + GND 7 8 9 0 Table : Connecting the to M-WRG-S/Z-T ventilation units Am Hartholz D-89 Alling - 0 -

. Connecting the to M-WRG-S/Z-T-F ventilation units Terminal blocks Number M-WRG-S/Z-T-F ventilation unit Pushbutton LED (master) (slave) (slave) (slave) (slave) + GND 7 8 9 0 7 Table : Connecting the to M-WRG-S/Z-T-F ventilation units. Connecting the to M-WRG-S/Z-T-FC ventilation units Terminal blocks Number M-WRG-S/Z-T-FC ventilation unit Pushbutton LED (master) (slave) (slave) (slave) (slave) + GND 7 8 9 0 7 8 Table : Connecting the to M-WRG-S/Z-T-FC ventilation units Am Hartholz D-89 Alling - -

We have checked the content of this publication for conformity with the unit described in it. There may nevertheless still be differences, so we cannot guarantee complete accuracy. The information in this publication is regularly checked and any necessary corrections are made in the subsequent editions. Copyright We reserve the right to make changes. Am Hartholz D-89 Alling Germany Tel. +9 (0)8 079-0 Fax +9 (0)8 079-9 Internet: www.meltem.com Email: info@meltem.com Go to Meltem download area Am Hartholz D-89 Alling - -