Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Similar documents
Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type BBS-03, BBS-05, BBS-06, BBS-25

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2030, 2031, 2031 K, 2032, 2033, 2037

Operating instructions - Translation of the original -

Type C-CUT. Quickstart. English Deutsch Français

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Declaration of Conformity as per Directive 97/23/EC

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Declaration of Conformity as per Directive 97/23/EC

Instruction Manual Contact Pressure Vacuum Gauge

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Operating instructions - Translation of the original -

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Declaration of Conformity as per Directive 97/23/EC

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Operating instructions - Translation of the original -

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Pressure Reducing Valve DMV 750 set range: bar

Pressure relief valve

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 06.

Pressure relief valve

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

Installation and Commissioning Instructions for GÄBLER-piston slide valves, especially for gaseous oxygen pipelines

Operating instructions - Translation of the original -

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Overview of types. Technical data. Safety notes

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Installation & Operation Manual Proven Quality since 1892

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Two-stage valve type NE

Manual Actuated Boiler Blowdown Valves

Flowmeter. Original operating manual DFM

Smooth Vent Valve XVD. Series

Universal Charging and Testing Unit FPU-1

Pilot Check Valve: Metal Body Type

Operating and maintenance manual Filter and reducing station Series / 1.0

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Materials : Stainless steel ASTM A351 CF8M

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure maintenance valve SDV-P / SDV-P-E

Safety valves. Component-tested safety valves DN Compressed Air Accessories II Hoses, valves etc. 15. Technical data. Exhaust capacity air

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

Installation, operation & maintenance manual - original version

Operating instructions - Translation of the original -

Smooth Vent Valve. XVD Series

Related Products: Auto Drain Valve. Model/Specifications. Model

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Instruction Manual. AlfaLavalSBAntiVacuumValve ESE02960-EN Original manual

Pressure Reducing Valve DMV 750

4/2 way Pneumatic Solenoid Valve

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Installation and Operating Instructions Bypass Flow Meter DST

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Overview of types. Technical data

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Steam trap BK 37 BK 28 BK 29 BK 37 ASME BK 28 ASME BK 29 ASME

Operating Manual FSV, FSÖV, SSVF

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

THE HF-210 SERIES. Operating and Service Manual. Series includes all variants of HF-210/211. Issue A October 2014 *Section 6.

3/8" Dr. Air Butterfly Impact Wrench

LRS(H)4 Pressure-Reducing Regulator User Manual

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

CAST IRON SAFETY VALVE TYPE 6301

Siphon vessel / Priming aid

Transcription:

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET 2/2-way valve with piston actuator and PTFE bellows 2/2-Wege Ventil mit Kolbenantrieb und PTFE-Faltenbalg Vanne 2/2 voies avec entraînement à piston et soufflet PTFE Operating Instructions Bedienungsanleitung Manuel d utilisation

Contens 1 OPERATING INSTRUCTIONS...2 2 Intended Use...3 3 Basic Safety Instructions...3 4 General Information...4 5 Structure and Function...5 6 Technical Data...6 7 Installation...8 8 MAINTENANCE, MALFUNCTIONS...11 9 Replacement parts...13 10 Transport, Storage, Disposal...13 1 OPERATING INSTRUCTIONS The operating instructions contain important information. Read the instructions carefully and follow the safety instructions in particular, and also observe the operating conditions. Instructions must be available to each user. The liability and warranty for Type 2080 are void if the operating instructions are not followed 1.1 Symbols Designates an instruction to prevent risks. designates a procedure which you must carry out. Warning of injuries: DANGER! Imminent danger. Serious or fatal injuries. WARNING! Potential danger. Serious or fatal injuries. CAUTION! Danger. Minor or moderately severe injuries. Warns of damage to property: NOTE! 2

2 INTENDED USE WARNING! Incorrect use of the bellows valve Type 2080 can be dangerous to people, nearby equipment and the environment. The device is designed for the controlled flow of liquid and gaseous media. For use observe the permitted data, operating and application conditions which are described in the contract documents as well as on the type plate and in the operating instructions in the chapters entitled 5 Structure and Function and 6 Technical Data. The device may be used only in conjunction with third-party devices and components recommended and authorised by Bürkert. Correct transport, correct storage and installation and careful use and maintenance are essential for reliable and problem-free operation. Use the bellows valve Type 2080 only as intended. 3 BASIC SAFETY INSTRUCTIONS These safety instructions do not make allowance for any: Contingencies and events which may arise during the installation, operation and maintenance of the devices. Local safety regulations the operator is responsible for observing these regulations, also with reference to the installation personnel. DANGER! Risk of injury from high pressure. Before loosening the lines and valves, turn off the pressure and vent the lines! Risk of burns/fire from continuous operation! When metering hot media, the device may become very hot. Always wear protective gloves when handling a device which controls hot media. Keep readily flammable materials and media away from the device. 3

General hazardous situations. To prevent injury, ensure that: Do not place any loads on the body (e.g. by placing objects on it or standing on it). Do not make any external modifications to the valve bodies. Do not introduce any aggressive or flammable media into the pilot air connections of the system. Supply the media connections only with those media which are specified as flow media in the chapter entitled 6 Technical Data. Secure to prevent unintentional actuation. Installation and repair work may be carried out by authorized technicians only and with the appropriate tools. After an interruption in the power supply or pneumatic supply, ensure that the process is restarted in a defined or controlled manner. The device may be operated only when in perfect condition and in consideration of the operating instructions. The general rules of technology apply to application planning and operation of the device. 4 4 GENERAL INFORMATION 4.1 Contact address Germany Bürkert Fluid Control Systems Sales Center Chr.-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel.: +49 (0)7940-10 91 111 Fax: +49 (0)7940-10 91 448 E-mail: info@de.burkert.com International Contact addresses can be found on the final pages of the printed operating instructions. And also on the internet at: www.burkert.com 4.2 Warranty The warranty is only valid if the bellows valve Type 2080 is used as intended in accordance with the specified application conditions. 4.3 Information on the Internet The operating instructions and data sheets for Type 2080 can be found on the Internet at: www.burkert.com

5 STRUCTURE AND FUNCTION 5.1 Modularity The valve is modular in design and can be supplied with different media connections (also customized) and actuator versions according to the application case. It can be used individually and also in blocks. Bolts for attaching the actuator to the body Pilot air connections Threaded ports G 1/8 Connection CF B (NO) Connection CF A (NC) 5.2 Structure The valve consists of a pneumatically actuated piston actuator with return spring, a stainless steel body and PTFE bellows. The bellows are used to separate media. If the installation location is appropriate, the valve is self-draining. The materials used and the inner contours facilitate cleaning (CIP/SIP). The pneumatic actuator must be controlled externally via a pilot valve or a valve island. Media connections: Flange Threaded port G 3/8 Welded end Notch for monitoring of bellow leakage 5

6 TECHNICAL DATA 6.1 Operating Conditions Ambient temperature -10... +90 C Medium temperature Media 6.2 Restrictions For Valves with a flow inlet over seat: WARNING! -30... +150 C (see PT graph) Neutral to aggressive gases and liquids, technical vacuum Risk of injury from water hammer. If flow inlet over seat with liquid media, water hammers may occur. As a consequence, lines or the device may burst and medium flow out. Consider the type of flow inlet and the type of medium for operation of the device. If flow inlet over seat before the use of liquid media, to avoid water hammers, in case of doubt, clarify the application conditions (medium, line length and cross-section) with the Bürkert sales office. 6.3 Conformity The device conforms to the EU directives according to the EU Declaration of Conformity. 6.4 Standards The conformity with EU guidelines is guaranteed in accordance with standards: EN 13463-1, EN 13463-5 6.5 PT graph Permitted pressure-temperature compatibility of the PTFE bellows (Pressure value [bar]: Measured as overpressure to the atmospheric pressure). P [bar] 9 8 7 6 5 4 3 2 Permitted range 1 0 0 20 40 60 80 100 120 140 160 180 T [ C] 6

6.6 Mechanical Data Dimensions See data sheet Body material Fitting Stainless steel 316L (1.4404) Actuator Stainless steel 304 (1.4301) Bellows Bellows stroke PTFE 2.5 mm Internal surface finish Ra = 0.8 µm 6.7 Fluidic data Circuit functions 2/2-way valve, servo-assisted, closed A without pilot air pressure by spring force, A actuation with pilot valve, valve island or P similar. 2/2-way valve, servo-assisted, opened B without pilot air pressure by spring force, B actuation with pilot valve, valve island or P similar. Fitting Pressure range of medium Vacuum... 8 bar (see PT graph) Back pressure tightness up to 8 bar Orifice DN 4 to DN 10 Line connections Threaded port G 3/8 Welded ends 13.5 x 1.6 in accordance with ISO 4200 13 x 1.5 in accordance with DIN 1850-2 12.7 x 1.2 in accordance with BS 4825 Flange connection or customized line connections Actuator Pilot air medium Compressed air 4.5 10 bar (dry and filtered) neutral gases Pilot air connections Threaded port G 1/8 7

6.8 Actuator versions Version Actuator Open - Closed Operating principle CF A and CF B Actuator Open - Closed with position indicator CF A and CF B 3 position actuator (with adjustable intermediate position) 6.9 Label (example) Description Made in Germany Bellows valve Type 2080 NC DN10 Pmax 8bar Ppilot 4-10bar CE 00450000 W14UN Ident. no. Nominal pressure of pilot valve Nominal pressure Type, Circuit function, Orifice CF A 7 INSTALLATION WARNING! Risk of injury from improper installation! Installation may be carried out by authorized technicians only and with the appropriate tools! Risk of injury from unintentional activation of the system and an uncontrolled restart! Secure system from unintentional activation. Following installation, ensure a controlled restart. 7.1 Fluid Installation DANGER! Danger high pressure! Serious risk of injury when reaching into the equipment. Before loosening the lines and valves, turn off the pressure and vent the lines. Check that the operating conditions correspond with the performance data of the device. 8

Installation position: Installation can be in any position. Install upright for self-draining (body to bottom and in the case of threaded port and welded ends install at a min. gradient of 1 for drainage of media). Installation Before installation, clean any possible dirt off the pipelines and flange connections. If necessary, install a dirt trap in front of the valve to protect it from malfunctions. Mesh size: 0.1... 0.4 mm WARNING! Danger - escaping medium! Leaky connections with seals not properly seated. Fit all connections carefully and seal properly. Seal the threaded port with a suitable sealing material (PTFE tape is recommended). Use the correct size of open-ended wrench to screw in the pipelines; do not use the valve actuator as a screwdriver! The device must not be subject to any lateral tension forces. The device connections must be in alignment with the lines! Attach the valve according to the connections: Threaded port by screwing in the pipes, Welded connection by welding, Flange by screwing on. Flange interface on the valve 16 13 16 16 16 Ø 4,5 Ø 3.1; 6 deep; Option for positioning pin ø 3 (ensure correct location for installation) 9

7.2 Option: Valve with 3 position actuator (with adjustable intermediate position) Functions of the valve: Closed (without pilot air, by spring force), Partial stroke (pilot air simultaneously on X and Y), Full stroke (pilot air on X only). Stroke setting on the spindle: Y Flow: plus minus Adjusting spindle Lock nut Setting the intermediate position: attach a suitable flow measuring device (measuring cup, flow meter, etc.), loosen the lock nut, connect pilot air to X and Y, open the medium supply, set the required flow on the adjusting spindle stroke range = 0 to 2.5 mm (rotating the spindle clockwise reduces the flow), switch off the pilot air, tighten the lock nut. Flange version X 10

8 MAINTENANCE, MALFUNCTIONS DANGER! Danger high pressure in the equipment! There is a serious risk of injury when reaching into the equipment. Before loosening the lines and valves, turn off the pressure and vent the lines. WARNING! Danger due to improper maintenance work! Improper maintenance may result in injuries as well as damage to the device and the surrounding area. Maintenance work may be carried out by authorised technicians only and with the appropriate tools! Danger due to unintentional activation of the equipment! Unintentional activation of the equipment during maintenance and repair work may result in injuries and/or damage. Take appropriate measures to prevent the equipment from being unintentionally activated. 8.1 Maintenance / Cleaning The bellows situated between the medium compartment and actuator ensure that the valve switches reliably and protect the medium from contaminants coming from the actuator side. These bellows are subject to symptoms of fatigue. If the bellows are defective, medium will escape out of the leakage detection opening. To prevent them from being destroyed, the bellows should be changed prophylactically at regular intervals (see chapter 8.2 ). The valve interior has no gaps and the inner compartment and bellows have been designed with very smooth contours (surface roughness max. 0.8 µm). The valve is CIP compatible (CIP = cleaning in process) and SIP compatible (SIP = sterilization in process). 8.2 Changing the bellows Removing the actuator Provide the required spare parts and a size 7 open-ended wrench, Interrupt the pilot air supply, vent and disconnect the lines, Interrupt the medium supply and vent the lines, Loosen both fastening screws, Remove the actuator. 11

Changing the bellows Unscrew the bellows from the spindle, Clean the inner compartment of the body, Manually screw the new bellows onto the spindle and tighten them hand-tight. Attaching the actuator Clean the O-ring 25 x 2 FKM 70 in the body, check whether it can be re-used and, if required, replace it with a new O-ring Place the actuator with new bellows on the body; ensure that the bores in the actuator are correctly aligned with the thread in the body Attach the actuator to the body with the fastening screws (tightening torque from 2 to 2.2 Nm). Restarting the bellows valve Connect the pilot air line, Open the pilot air, Open the medium supply, Conduct a function and leak test,, If the valve functions reliably, it can be restarted. Exploded drawing of changing spare parts, Type 2080 Hexagon screws M4 x 50 in accordance with DIN 933-A4 for attaching the actuator to the body Actuator Spindle PTFE bellows O-ring 25 x 2 FKM 70 Body (threaded port version) 8.3 Malfunctions If malfunctions occur, check: the line connections, the operating pressure, the pilot air supply which actuates the valve, 12

the bellows and, if required, change them (see chapter 8.2 ). If the valve still does not switch, please contact your Bürkert Service. 9 REPLACEMENT PARTS CAUTION! Risk of injury and/or damage by the use of incorrect parts! Incorrect accessories and unsuitable spare parts may cause injuries and damage the device and the surrounding area. Use only original accessories and original replacement parts from Bürkert. Order table of spare parts Spare part Description Order no. Bellows Material PTFE 799 845 O-ring 25 x 2.0 N-FKM 70 914 378 10 TRANSPORT, STORAGE, DISPOSAL NOTE! Transport damages! Inadequately protected equipment may be damaged during transport. During transportation protect the device against wet and dirt in shock-resistant packaging. Avoid exceeding or dropping below the allowable storage temperature. Incorrect storage may damage the device. Store the device in a dry and dust-free location! Storage temperature: -20... +65 C. Damage to the environment caused by device components contaminated with media. Observe applicable regulations on disposal and the environment. Dispose of the device and packaging in an environmentally friendly manner. 13

Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940-10-91 111 Fax + 49 (0) 7940-10-91 448 E-mail: info@de.buerkert.com International address www.burkert.com Manuals and data sheets on the Internet : www.burkert.com Bedienungsanleitungen und Datenblätter im Internet: www.buerkert.de Manuels d'utilisation et fiches techniques sur Internet: www.buerkert.fr Bürkert Werke GmbH & Co. KG, 2008-2017 Operating Instructions 1705/0 _ _00805 / Original DE www.burkert.com