Advanced Test Equipment Rentals ATEC (2832)

Similar documents
Columbus Instruments

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

This test shall be carried out on all vehicles equipped with open type traction batteries.

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

CSA Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

It s Just Calibration How Hard Can It Be?

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Instruction and Maintenance Manual

Mass Flowmeters. Mass Flowmeters for Gases

8.1 Calibration of gas sensors

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

UNDERSTANDING, ACCELERATED

Instruction and Maintenance Manual

CORESTA RECOMMENDED METHOD N 6

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

FTC130 Transmitter. Operating Manual

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

TXDOT DESIGNATION: TEX-922-K

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

TXDOT DESIGNATION: TEX-922-K

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Model Description

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

IRwin Methane Leak Detector. Innovation makes the difference

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Gas-Detection Instruments

Misuse of Combustible Gas Meters

Generating Calibration Gas Standards

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Do Not Print This Page.

Instruction Manual Dräger MSI P7 and MSI P7 plus

GasSense NDIR User Manual

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

APPENDIX C. 40 CFR PART 60 App. B SPEC. 1-4, 6

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

with O 2 Controller Instruction Manual

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

LP Gas Odorization and Testing

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

Automatic Isokinetic Sampler. ST5 Evo

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

Hand-held pressure calibrator with integrated pump Model CPH6600

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

Protective Atmospheres, Measurement Technologies and Troubleshooting Tools

Truck-mounted Mass Flow Metering for LPG Delivery

Standard Operating Procedure for H 2 S and SO 2 Converter

Calibration Requirements for Direct Reading Confined Space Gas Detectors

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Thermo Scientific Model 146i Principle of Operation

MODEL GT820 OXYGEN SENSOR

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

PM105 PRESSURE METER USER S MANUAL

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

OPERATION MANUAL ID900

Application Note AN-107

Smart Water Application Technologies (SWAT)

Standard Test Methods for Water Vapor Content of Electrical Insulating Gases by Measurement of Dew Point 1

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Technical Procedure for General Laboratory Equipment

CHAPTER 3 RESULTS AND DISCUSSION

4.0 Audit Procedure for the MetOne SASS Speciation Sampler

Coda cx1 Thermal Cycle Test Procedure

City & County of San Francisco Office of Contract Administration Purchasing. Bid #: ITSF /CD Req #: RQUH Attachment B

pren CEN standard-draft pr EN 12261

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

300 Held Drive Northampton Pa

Operating Characteristics and Handling Manual for the NAP-55A / NAP-50A Explosive/Flammable Gas Sensor NEMOTO

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Technical Information Conducal CLY421

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

VIC offers a variety of Calibrated Gas Leaks

Description Advanced Features Typical Applications

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

METHOD 2A - DIRECT MEASUREMENT OF GAS VOLUME THROUGH PIPES AND SMALL DUCTS. NOTE: This method does not include all of the

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Pneumatic high-pressure controller Model CPC7000

Getting the Most From Your Diagnostic Equipment

RGC-IR Remote Gas Calibrator for IR400

DQM Annual Hopper QA Checks

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) DOCUMENT NO: STP 2203 VERSION: 2008-07-01 Page 1 of 6 1.0 PURPOSE This test procedure is used by the Electrical Safety Division to determine if samples of portable methane-indicating detectors or a multi-gas detector that has methane detection capability meet the requirements of 30 CFR Section 22.7(d)(2). 2.0 SCOPE To provide a person knowledgeable in the appropriate technical field with a written procedure that will assure consistent repeatable test data and results independent of the person conducting the test. 3.0 REFERENCES 3.1. 30CFR Section 22.7(d)(2) (Appendix 1) 3.2. ACRI2001 "Criteria for the Evaluation and Test of Intrinsically Safe Apparatus and Associated Apparatus". 4.0 DEFINITIONS 4.1. Replacement ratio - The ratio of the carrier/air flow rate in liters per minute to the free space volume in liters of the test box, less any sample(s) drawn from the test box. 4.2. Free space volume -The volume of the test box minus the volume of the detectors and other devices located within the test box. 4.3. Methane detector - A device that may be used to detect the presence of methane in a gassy mine. 4.4. Methane-indicating detector - A device that will show, within certain limits of error, on an adequate scale, the percentage of methane in a gassy atmosphere. 4.5. Multi-Gas Detector/Monitor A device that may be used to detect the presence of methane and other gases in a gassy mine. 5.0 TEST EQUIPMENT 5.1. A test box large enough for the number of test samples to be tested. The box must have at least three inlet/outlet ports - an inlet in a lower section of the box, an outlet in an upper section of the box on the side opposite the inlet,

DOCUMENT NO: STP 2203 VERSION: 2008-07-01 Page 2 of 6 and an outlet for connection of the gas measuring instrument in the center of the box. 5.2. An environmental chamber capable of housing the test box and detectors tested outside of the test box (if applicable). It must maintain interior temperatures between 50 ºF and 70 ºF in increments of 5 ºF. [Tenney Model TH27-3 Environmental Chamber]. 5.3. Gas analyzer with a range of at least 0 to 10 % volume methane-in-air; a resolution of at least 0.01 % volume methane-in-air, and accuracy of at least ± 0.05 % volume methane-in-air [Horiba Model VIA-510]. 5.4. Gas mixing equipment to supply methane-in-air mixtures of 0.25 to 5.00 (±0.05) percent by volume at the calculated flow rate [Matheson Dynablender Model 8250]. 5.5. A five-foot (minimum) length of coiled copper tubing. The test gas flows through this tube to condition the test gas to stabilize at the temperature inside the environmental chamber. 5.6. A flow meter for measuring the test gas flow rate entering the test box, and the flow rate of the detector's built-in sampling pump or optional sampling pump. [Gilian "Gilibrator"] 5.7. A thermometer with a range of at least 0 70 ºF, a resolution of at least 0.2 ºF, and an accuracy of at least 1 ºF for determining the interior temperature of the environmental chamber [Fluke 2170A]. 5.8. Certified gas measuring equipment (Horiba Model VA-510 CH 4 Analyzer Unit) 6.0 TEST SAMPLES 6.1. Four representative production samples of the portable methane-indicating detector. If the detector includes an optional sampling pump, two of the samples should include the pump. 6.2. For pump or aspirated detectors, a sampling tube of specified maximum length and minimum inside diameter. If different maximum lengths of tubing are specified for tubing with different diameters, calculate the time necessary for a gas sample to travel the length of the tube to the detector.

DOCUMENT NO: STP 2203 VERSION: 2008-07-01 Page 3 of 6 Select the sampling tube that would require the longest time to travel the length of the tube. 6.3. The manufacturer's calibration kit, calibration procedures, probes, sampling lines, extra batteries, and battery chargers (if rechargeable). 7.0 PROCEDURES 7.1. Charge the detectors according to the manufacturer's instructions or install fresh batteries. 7.2. Calibrate the detectors according to the manufacturer's instructions. If more than one calibration procedure is included in the manufacturer s instructions, each specified procedure must e used on at least one test sample. Analyze the calibration gas with the gas analyzer. Record the reading. Note: Do not recalibrate the detectors during the test. 7.3. Reapply the manufacturer s calibration gas (using manufacturer s calibration kit), and record the detectors readings. Note: Testing may be stopped here if readings are not within manufacturer s published specifications, or if a proper calibration could not be performed. 7.4. Calculate and record the free space volume of the test box. 7.4.1. Measure and record the inner dimensions of the test box, and calculate and record its volume. 7.4.2. Measure and record the outer dimensions of each detector or other device to be placed into the test box. Calculate and record the total volume that all devices within the test box will occupy. 7.4.3. Subtract the volume of the detectors from the volume of the test box. 7.5. Measure and record the length and inside diameter of any sampling tubes. 7.6. Calculate and record the test gas flow rate necessary to maintain a replacement ratio between 0.5 to 0.8 exchanges per minute in the test box. If the detectors have sampling pumps, increase the calculated test gas flow rate to compensate for the flow drawn by the pump(s) as specified by the applicant.

DOCUMENT NO: STP 2203 VERSION: 2008-07-01 Page 4 of 6 7.7. For diffusion type detectors, place the detectors into the test box and place the test box into the environmental chamber. Arrange the detectors such that they do not obstruct the inlet and outlet ports of the test box. Position the sensor head of each detector away from any inlet port. 7.8. For pump or aspirated type detectors, connect the sampling tube to the test box through a gas port located near the center of the side of the test box. Place the test box and detectors into the environmental chamber. If a probe is specified for use on the sampling tube, mount the probe such that the test gas is drawn from the middle of the test box through the probe. 7.9. Connect tubing from the gas mixing apparatus to the coiled copper tubing in the environmental chamber. Connect tubing from the outlet of the copper tubing to an inlet port on the test box located near the bottom of the test box. 7.10. Connect an exhaust tube to an outlet port near the top of the test box so that the test gas exhausts outside of the building. DO NOT USE A FAN TO EXHAUST. 7.11. Connect the gas sampling tube from the gas analyzer to an outlet port at the same level as the sensor heads (diffusion type detectors) or at the same level as the outlet port to pump or aspirated type detectors. 7.12. Set the environmental chamber to (70 ±1) ºF. Allow the test chamber to stabilize at that temperature for one hour. 7.13. Check and adjust, if necessary, the zero and span readings of the gas analyzer. 7.14. Set the gas mixing apparatus to flow only air at the flow rate calculated in 7.6. Record the readings of the detectors. 7.15. Introduce the test gas into the test chamber at the flow rate calculated, starting at 0.25%. 7.16. Once the concentration within the test box reaches the set test gas concentration, wait for at least two minutes. Record the test gas concentration, and each of the test samples readings on the test sheet.

DOCUMENT NO: STP 2203 VERSION: 2008-07-01 Page 5 of 6 Note: If the concentration within the test box does not reach the test gas concentration, check the test box or connection lines for leaks, verify proper operation of the gas measuring equipment and repeat this step. 7.17. Repeat 7.15 and 7.16 setting the gas mixing apparatus, in this order, to 0.5%, 1.0%, 2.0%, 3.0%, 4.0%, 5.0%, 5.0%, 4.0%, 3.0%, 2.0%, 1.0%, 0.5%, 0.25%, and 0.0% volume methane-in-air. 7.18. Set the environmental chamber to (65 ±1) ºF. Allow the test chamber to stabilize at that temperature for one hour. 7.19. Repeat 7.15 thru 7.17 four more times, reducing the temperature in the environmental chamber from 65 ºF to 50 ºF in 5 degree increments. Take fresh air readings before the start of each series. 8.0 TEST DATA 8.1. The analyzed reading of the calibration gas. 8.2. Readings of the instruments when the calibration gas is applied. 8.3. The manufacturer, model number, and serial number of each detector, and part number of the pump, if it is an optional type and not internal to the instrument 8.4. Reference the manufacturer's calibration procedure filed in the correspondence folder of the investigation. 8.5. Specified flow rate of any sampling pump. 8.6. Length and inside diameter of any sampling tubes 8.7. Calculation of the test gas flow rate 8.8. Manufacturer, model number, serial number, and calibration due date for all test equipment 8.9. Internal temperature of the environmental chamber, test gas concentration from the gas analyzing equipment, and gas concentration as displayed on each detector under test. 9.0 PASS/FAIL CRITERIA

DOCUMENT NO: STP 2203 VERSION: 2008-07-01 Page 6 of 6 The detector fails if the average of the ten readings (two readings for each percentage at five different temperatures), or more than two readings for each percentage of any of the four samples exceed the limits of error given below. Methane-in-air mixtures Minimum indication Maximum indication 0.00-0.10 0.10 0.25 0.10 0.40 0.50 0.35 0.65 1.00 0.80 1.20 2.00 1.80 2.20 3.00 2.70 3.30 4.00 3.70 4.30 5.00 Manufacturer's specifications Manufacturer's specifications