ANESTHESIA VAPORIZER SERVICE RECOMMENDATIONS

Similar documents
VAPOMATIC ANESTHETIC VAPORIZER

Anesthesia Machines. Inhaled Anesthetic Agents

Anesthesia. Midmark Animal Health Products

BleaseDatum Anesthesia Vaporizers PEACE OF MIND. Serving The HealthCare Industry

Flow meter. bellow vaporizer. APL valve. Scavenging system

BleaseFocus Anesthesia System VERSATILE ANESTHESIA

Recommendations on Checking Anaesthesia Delivery Systems

Anesthesia Machine Intro

The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the

Sigma Delta Vaporizer User Instruction Manual

Anes Machine Use and Pre-use Check - CA1 focus

A9600 Anesthesia Workstation. Your healthcare, we care.

New Anesthesia Delivery Systems What Do I Need to Know About My New Machine?

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

NARKOVET ANAESTHETIC UNIT

Hallowell EMC Anesthesia WorkStation Operating Manual

M5400 Operators Manual

Landmark. Veterinary Anesthesia Systems. Operator s Manual P/N

Isoflurane: Safe Use Guidelines. (2-chloro-2-(difluoromethoxy)-1,1,1- trifluoro-ethane) is a halogenated ether used for inhalational anesthesia.

Datum 'L' Vaporizer. Blease. L Series. Anaesthesia Vaporizer. User Manual. Blease. User Manual

Anesthesia Workstation

Proceedings of the World Small Animal Veterinary Association Sydney, Australia 2007

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

GAS ANESTHESIA SYSTEMS. Cat. No / 22100

GE Healthcare. Aestiva/5. More than superior ventilation

Vaporisers for anaesthesia

THE GE AISYS ANAESTHETIC MACHINE

Installation & Operation Manual 2011 Midmark Corp. 60 Vista Drive Versailles, OH USA

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

APUS Anesthesia Machines

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

OPERATION MANUAL NTF-15

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Standard Operating Procedure Measuring & Testing Equipment

DPC-30 DPC-100. Reference Manual

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

Diffusing Capacity: 2017 ATS/ERS Standards for single-breath carbon uptake in the lung. Susan Blonshine RRT, RPFT, FAARC, AE-C

Engineering World Health Youth EWH Design Projects That Matter

USER MANUAL. SAVE THESE INSTRUCTIONS (For latest revision, go to

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

Do Not Print This Page.

Aespire 7100 Essential performance Compact design

OPERATION MANUAL NTF-60 Plus

Comparison Of The Efficacy Of Two Low Fresh Gas Flow Techniques In Low Flow Anaesthesia

4 CONTROL-CHART EXAMPLES

QUICK START GUIDE TO DRINKING WATER MONITORING

GE Healthcare. Avance Carestation. Upgrade promotions guide

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

ALLIED HEALTHCARE PRODUCTS, INC. Litholyme, GE Medisorb, Carbolime, and Amsorb Plus. Test Summary

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

IVIS Spectrum Whole Animal Imager

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

IV-ANE. User s Manual. Anesthesia equipment for test animals. Petition

S/5 Aespire. Quick Reference Guide

Operating and maintenance manual Filter and reducing station Series / 1.0

Anesthesia Delivery Systems What Do I Need to Know About My Machine? A Workshop James H. Philip, MEE, MD, CCE

ACUC ۰ ROUTINE PROCEDURE

User Guide and Operating Manual

OxiQuant S. Operating Instructions

PAPR Flow Tester. instructions. part no WARNING

- GAS REGULATOR - COMPACT STYLE

Fire Escape Hood OPERATION AND INSTRUCTIONS

CAL. Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE R218P12. R218M12 Rev. J

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

LION ERS Glove System

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

NITRONOX USER S MANUAL

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

PROCESS CONTROL HANDBOOK Z-6

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Service and Repair Manual

CITREX H4 Mobile gas flow analyser. The ideal mobile device for flow and pressure analysing.»

Standard Operating Procedure. Air Displacement Pipette Calibration

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

USER MANUAL LTH-255A Hand Piece

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

RAM Operation Manual

Draeger Fabius GS Pre-Use Check

Welcome to Huma-Air. We design and manufacture brand- and model specific precision regulators for PCP air rifles.

Understanding vaporizers

Advanced Test Equipment Rentals ATEC (2832)

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Simplified Automated Ventilator Training Slides

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

REGULATOR OWNER S GUIDE

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

User Manual for the Mars Calibration Bench

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

Update on Thoracic Anesthesia: Perioperative Lung Protective Strategies in One- and Two-Lung Ventilation

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Effective 2/1/17. SC1 Service Call PER Visit $76.00

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Blease900 Ventilator PATIENT CENTERED VENTILATION

Transcription:

ANESTHESIA VAPORIZER SERVICE RECOMMENDATIONS The anesthesia vaporizer is a critical component of your anesthetic machine. It is very important to ensure that the appropriate percentage of anesthetic agent is being delivered. A malfunctioning vaporizer can be the cause of inappropriate depth of anesthesia (ex: animals under too lightly or too deep) and may also be the reason you lose a patient. Most vaporizers used today in veterinary practices are used with either Isoflurane or Sevoflurane. There are still some Halothane (fluothane) vaporizers on the market, however, the agent is hard to come buy as most manufacturers have discontinued its production. FREQUENCY OF SERVICE You should have your anesthesia machine maintained annually. Leaks on your machine can provoke dilution of anesthetic gasses and pollute your environment, not to mention increase your operating costs. The fact that you have no problems keeping your animals under does not mean that your staff is not breathing the gasses all day long as well. At the time of service the technician should have an anesthetic agent monitor and should provide you with the readings of the vaporizer. It is important to note that these readings are only an indication of the vaporizer output at the time of inspection, it is not a calibration. Calibration of vaporizers is impossible to perform on-site as it must be done in a controlled environment. Anyone who tells you otherwise is misleading you. Most vaporizers on the market are considered in spec. if the output is within +- 15% of the dial setting. If the output is beyond that the technician will recommend exchanging your vaporizer with a freshly calibrated one or to send your vaporizer out for recalibration.

THE FIRST CANADIAN VAPORIZER SERVICE CENTER FOR HUMAN AND VETERINARY ANESTHESIA WAS SET-UP AND OPERATED BY ONE OF OUR STAFF.

HALOTHANE If you are using Halothane, it should be fully recalibrated and overhauled annually, the agent contains a preservative (Thymol) which gradually creates deposits on all parts of the vaporizer, causing the dial to be harder to turn and intermittently effect output. ISOFLURANE & SEVOFLURANE Since these agents do not contain Thymol, they do not leave deposits in the vaporizer and need less frequent recalibrations. It is still necessary to have the output checked annually when verifying your anesthesia machine. An indication that your vaporizer is due for recalibration is if you find yourself routinely having to use concentrations higher or lower than you generally use. Naturally, it is assumed that you perform daily leak checks on your anesthesia machine. WHY CAN T VAPORIZERS BE SERVICED ON-SITE? Vaporizer output is affected by the temperature of the agent. The colder the agent, the lower the vaporizer output; the hotter it gets the higher the output. Several factors affect the temperature. The oxygen flow through the vaporizer cools the agent down; the room temperature affects the vaporizer temperature. The vaporizer contains a thermostat which regulates the output to compensate for these temperature variations but it has its limits. In order to recalibrate the thermostat it must be done in a temperature controlled environment. Adjustments are made at precise temperatures and rechecked with a minimum pause of 4 hours between adjustments to confirm stability. Several subsequent identical readings are required before considering the calibration to be valid. This process may take up to 5 days. Once completed, the vaporizers are fully dried before shipping.

REPLACEMENT PARTS During the recalibration process, many parts require replacement. The wick assemblies, the o-rings, etc., should always be replaced. Any other worn part should also be replaced. FIRST USE When you fill your vaporizer for the first time it may seem that you are losing agent rapidly. This is normal. A cotton wick inside the vaporizer absorbs a great deal of liquid and requires 2 to 3 fillings before being fully saturated. TRANSPORT PREPARATION Before sending your vaporizer for recalibration it must be drained of all agents. Leaving agent in the vaporizer can cause damage. Proper packaging is very important.

WHAT CAN YOU EXPECT FROM DISPOMED? EXPERTISE Dispomed has been manufacturing and servicing anesthesia equipment for over 30 years. Our vaporizer techs are factory trained. The first Canadian vaporizer service center for human and veterinary anesthesia was set-up and operated by one of our staff while employed by Ohio Medical products (now known as GE Healthcare). SERVICE REPORTS Complete reports are filed with all the information regarding any service provided by a Dispomed tech. These reports indicate concentrations, performance and recommendations. TECHNICAL SUPPORT Techs are available to answer all of your questions and concerns regarding the use and care of your anesthesia equipment, vaporizers and many other products. FOLLOW-UP Dispomed will contact you ahead of time to schedule your preventative maintenance. All previous reports will be checked to follow-up on recommendations which where previously noted. FOR MORE INFORMATION REGARDING PRODUCTS AND SERVICES AVAILABLE AT DISPOMED, YOU MAY CONTACT US DIRECTLY AT 1-800-363-1746 OR BY E-MAIL AT info@dispomed.com

WE ARE EXPERTS! TEC 3 TEC 4 TEC 5 PENLON