Bracing Systems. Available At VIKING SA Tel: (+352) Fax: (+352)

Similar documents
TECHNICAL HANDBOOK nvent CADDY Speed Link Manual. SLS Locking Device

CADDY SPEED LINK MANUAL SLK LOCKING DEVICE

New Product. featuring an exclusive dual directional head* Innovative Fastening Technologies. From the makers of. * Patent-pending design.

TECHNICAL HANDBOOK. nvent CADDY Speed Link Manual Overview of Wire Rope Hanging

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

SASK-A-POLE OWNERS AND USERS MANUAL

OPERATION AND INSTRUCTION MANUAL

Vertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

This document to be used with Hurley traditional Davits

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

OPERATION AND INSTRUCTION MANUAL

RADROVER REAR RACK INSTALLATION MANUAL

ALTERNATOR RACKS 135, 170 & 190 INSTRUCTIONS

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

TOWER INSPECTION REPORT

USER INSTRUCTION MANUAL CONCRETE BOLT ANCHORAGE CONNECTOR

DO NOT use any Alien Flier Zip Line Products or Accessories until you read and understand these SAFETY WARNINGS!

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

Vessel Installation and Operating Manual

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)

Traditional Basketball Set. Assembly & Installation Instructions

Spring steel fasteners KWHS-14R. KwikWire. Hanging system

DT400/436 Tee Connector Installation Instructions

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

B-LINE SERIES. Spring steel fasteners KWHS-15. KwikWire. Hanging system

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

600 / 600FC OWNER'S MANUAL

Revolution Gurney Attachment

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

GUARDIAN FALL PROTECTION

InstallatIon and owner s InstrUCtIons

SERIES BB TRASH BASKETS

ROPV R40 E Series User Manual

Corrugated Hose Loop Calculations

Installation and Operating Manual

Universal Elevator Mount Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.

Page 1 of 1 04/19/13 SBR

SERIES L4E & L6E LADDER EXTENSIONS

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

BS Series Basket Strainer

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-100. Club Volleyball Gear WARNING

Universal Anchoring Adapter For Mercedes

USER MANUAL Do not throw away these instructions. Read and understand these instructions prior to use of the Lad Grab Safety System.

Moai Bike Rack Heavy Duty Submittal Sheet. Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Capacity: Mount Options: Setbacks: 2 Bikes

HANGERS & SUPPORTS CLIP-IT CLIP-IT STUD STRAPS BAR JOIST CLIP CONDUIT HANGERS CLIP-IT

COPY. **For U.S. and Canada Customers ONLY:** IF ASSISTANCE IS NEEDED,

TR5000 THE TOUGHEST TRAINING SYSTEM ON THE PLANET. MODEL NO. STRIKER TRAINER 2L Escalade Sports

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

602 STRINGING MACHINE OWNER'S MANUAL

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

MODEL TRIPEX PULLEY SYSTEM

The P-Rod Double by The Airgun Lab Installation Instructions Revision F 08/01/2016 page 1 of 18

OWNER S MANUAL. Made in the USA

Football Equipment. 5 9/16" Gooseneck Goalposts

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

Made in U.S.A. Narrow-U Bike Rack Heavy Duty Submittal Sheet. Materials: Finishes: Mount Options: Setbacks:

Assembly Instructions & Manual. Configuration subject to change

Side-of-Pole Mount for 1 Module (SPM1) For Module Type C

8MAY15 US RACK, Inc Falcon Drive, Madera, CA

INSTALLATION HANDBOOK

SERIES BA TRASH BASKETS

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

2000 lb manual winch

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

OPERATION AND INSTRUCTION MANUAL Beam Trolley Model: BTA012N

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

SIMPLAIR PIPING TOOL. JXT Company

Series 8500 Expansion Compensators. Catalog 674H

Airwalker. Installation and Safety Information. Stretch Products for Dance, Therapy, Education, and Fitness

Copyright Trek Bicycle Corporation 2005 All rights reserved

Operations and Instruction Manual Might Swivel Model # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems INSTALLATION GUIDE

2018 ACCESSORY ATTACHMENTS OWNER S MANUAL

HMO500. Headrest Hardware. Stealth s Multi-Axis Headrest Hardware. Installation Manual INSTALLATION INSTRUCTIONS FOR. Stealth Products HMO500 Hardware

Adapter Kit 5WAR RA NT Y. For use with EZ-Up Gravity Boots and select Teeter Inversion Tables* NEW! Assembly Instructions FULL YEAR

For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35

SKYBIRD TRAP OWNER S / OPERATOR S MANUAL PARTS AND ASSEMBLY INSTRUCTIONS

USER S GUIDE & SAFETY MANUAL USER S GUIDE & SAFETY MANUAL Duct Rodder

Cylinder Tilt Saddle Instruction Manual

REACH COMPLIANT 2500 WEIGEL STREET CADILLAC, MI

INSTRUCTIONS PARTS LIST

USER MANUAL. DM65 Manual Flush/Tilt Combo Mount

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-400. Club Volleyball Gear

INSTALLATION AND OPERATING INSTRUCTIONS. T10219-AD Deckboat 40 with AutoDeploy and Wireless Remote Control

COOPER POWER SERIES. Manual or Hostick Operable, Padlockable 150 A Tap-Changer Switch Installation Instructions. Tap-Changer Switch MN800015EN

Transcription:

Bracing Systems Available At VIKING SA Tel: (+352) 58-37-37-1 Fax: (+352) 58-37-36 Email: vikinglux@vikingcorp.

Bracing Systems To help ensure the availability and operation of safety systems after an earthquake event, many building and industry codes now include requirements for the design and installation of seismic sway bracing for non-structural components, such as fire sprinkler, mechanical, electrical and plumbing systems. The innovative line of CADDY Bracing Systems was developed to help keep fire sprinkler systems intact after a seismic event and to minimize water damage resulting from leaks or ruptures. CADDY Bracing Systems provide contractors with high-quality, engineered solutions, which include rigid bracing, cable bracing and rod stiffeners. Quick and easy installation Lower total installed cost Meets requirements of NFPA 13 culus Listed FM Approved OSHPD Pre-Approved Rigid Bracing Cable Bracing Branch Line Restraint System Rod Stiffeners 2 www.erico.com

Rigid Bracing The CADDY line of innovative rigid bracing products was designed to provide superior performance and meet the highest seismic load requirements. The products have been designed with the end user in mind and provide contractors with labor-saving features to promote quick and easy installation. The system of products supports lateral and longitudinal bracing and offers a wide range of structural and pipe attachments. Patent-pending lateral braces eliminate need for multiple trips up and down ladders Adjustable design can be used with different brace pipe sizes, providing flexibility on the jobsite and reducing contractor inventory Snap-off bolt head helps enable easy installation and inspection of seismic sway braces culus Listed FM Approved OSHPD Pre-Approved (OPA-2629-10) to the 2010 California Building Code Structural Attachments for Rigid Bracing Sway Braces Replacement Nuts and Bolts for Rigid Bracing www.erico.com 3

Structural Attachments for Rigid Bracing Bar Joist Attachment Adjustable I-Beam Attachment Multi Attachment Strut Seismic Hinge Universal Structural Attachment 4 www.erico.com

Bar Joist Attachment Can be installed on bar joists or I-beams Thumb spring retainer allows for ease of positioning Snap-off bolt head helps enable easy installation and inspection of seismic sway braces No assembly required No loose parts Meets NFPA -13 requirements for seismic sway bracing Article Number Finish Flange Thickness FT A B C CSBBARJEG 404354 Electro-galvanized 6,4 12,7 mm 50,8 mm 76,2 mm 63,5 mm CSBBARJHD Hot-dip galvanized 6,4 12,7 mm 50,8 mm 76,2 mm 63,5 mm UL Loads Brace Direction to Structure Size Rating Parallel 25-250 mm 13340 N Perpendicular 25-300 mm 16630 N FM Loads Horizontal Capacity per Intallation Angle from Vertical Brace Direction Size 30-44 45-59 60-74 75-90 Parallel N/A 6270 N 9385 N 11300 N 12590 N Perpendicular N/A 7740 N 7605 N 9165 N 10230 N www.erico.com 5

Adjustable I-Beam Attachment No loose parts No assembly required Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Meets NFPA -13 requirements for seismic sway bracing Article Number Flange Thickness FT CSBIB075085EG 404365 6,4 19,1 mm 100 216 mm 63,5 mm 304,8 mm 69,9 mm CSBIB075145EG 404366 6,4 19,1 mm 216 368 mm 63,5 mm 431,8 mm 69,9 mm CSBIB125180EG 404367 19,1 31,8 mm 100 457 mm 88,9 mm 546,1 mm 79,4 mm A Height H Length L Width W UL Loads Brace Direction to Structure Size Rating Parallel 25-300 mm 13340 N Perpendicular 25-300 mm 16630 N FM Loads Horizontal Capacity per Installation Angle from Vertical Brace Direction Size 30-44 45-59 60-74 75-90 Parallel N/A 7,205 N 7,605 N 4,495 N 4,940 N Perpendicular N/A 7,205 N 10,230 N 12,545 N 13,965 N 6 www.erico.com

Multi Attachment Disperses load over two anchors Minimizes the number of installed braces needed for concrete and wood structures Ideal for deck installations Use for both lateral and longitudinal sway brace applications Meets NFPA -13 requirements for seismic sway bracing Article Number Hole Size 1 HS1 Hole Size 2 HS2 A B C D UL Listed Load CSBMA050050EG 404371 14 mm 14 mm 304,8 mm 63,5 mm 63,5 mm 228,6 mm 16.636 N CSBMA050075EG 404372 20 mm 14 mm 304,8 mm 63,5 mm 63,5 mm 228,6 mm 16.636 N Mount to structure using holes indicated in HS1. www.erico.com 7

Strut Seismic Hinge Complete hinge assembly Ideal for attaching sway bracing to MEP system supports Attaches to strut trapezes and to structure Article Number Hole Size 1 HS1 Hole Size 2 HS2 Length L Width W Thickness T CSBSH00375EG 404463 14 mm 11 mm 179,8 mm 41,3 mm 6,4 mm CSBSH00500EG 404464 14 mm 14 mm 179,8 mm 41,3 mm 6,4 mm CSBSH00625EG 404465 14 mm 17 mm 179,8 mm 41,3 mm 6,4 mm CSBSH00750EG 404466 14 mm 21 mm 179,8 mm 41,3 mm 6,4 mm 8 www.erico.com

Universal Structural Attachment Universal design allows one product to attach directly to concrete, wood, bar joist or I-beam adapters Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Use for both lateral and longitudinal sway brace applications Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Center bolt does not require tightening Meets NFPA -13 requirements for seismic sway bracing Article Number Hole Size HS A B C CSBUNIV050EG 404407 14 mm 133,4 mm 101,6 mm 41,4 mm CSBUNIV075EG 404409 21 mm 133,4 mm 101,6 mm 41,4 mm UL Loads Brace Type Size Rating Pipe 25 mm - 250 mm 13,340 N 6mm Thick Angle 25 mm - 200 mm 8,960 N FM Loads Horizontal Capacity per Installation Angle from Vertical Brace Type Size 30-44 45-59 60-74 75-90 Pipe N/A 7,205 N 10,230 N 12,545 N 13,965 N www.erico.com 9

Shear Bolt Article Number Description CSBBARJSB50EG 402502 Shear Bolt for Bar Joist Attachment CSBIBSB50EG 402501 Shear Bolt for I-Beam Attachment CSBUNIVSB62EG 402503 Shear Bolt for Universal Sway Brace and Universal Structural Attachment Shear Nut Article Number Description CSBIBSN37EG 402500 Shear Nut for Adjustable I-Beam Attachment CSBQIKCLSN37EG 402505 Shear Nut for Quick Grip Jr. Lateral Sway Brace, 25-50 mm NB/DN 10 www.erico.com

Sway Braces Easy Universal Sway Brace Standard Universal Sway Brace Quick Grip Jr. Lateral Sway Brace Quick Grip Lateral Sway Brace Easy Universal Sway Brace Use for both lateral and longitudinal sway brace applications Unique slotted holes provide for easy slip-on installation eliminating loose hardware Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Meets NFPA -13 requirements for seismic sway bracing Article Number Pipe Size NB/DN A B Listings Approvals CSBEZU0100EG 404356 1" 25 mm 174,6 mm 25,4 mm UL, FM CSBEZU0125EG 404357 1 1/4" 32 mm 187,4 mm 25,4 mm UL, FM CSBEZU0150EG 404358 1 1/2" 40 mm 196,9 mm 25,4 mm UL, FM CSBEZU0200EG 404359 2" 50 mm 206,4 mm 30,2 mm UL, FM CSBEZU0250EG 404360 2 1/2" 65 mm 225,4 mm 30,2 mm cul, UL, FM CSBEZU0300EG 404361 3" 80 mm 238,1 mm 30,2 mm cul, UL, FM CSBEZU0400EG 404362 4" 100 mm 269,9 mm 38,1 mm cul, UL, FM CSBEZU0500EG 404363 5" 125 mm 308 mm 38,1 mm cul, UL, FM CSBEZU0600EG 404364 6" 150 mm 346,1 mm 50,8 mm cul, UL, FM www.erico.com 11

UL Loads (Listed for Restraints) Dyna-Flow Sch 10 Sch 40 CSBEZU0100EG N/A 2910 N 2910 N CSBEZU0125EG 2910 N 2910 N 2910 N CSBEZU0150EG 2910 N 2910 N 2910 N Dyna-Flow EZ FLOW Lateral Sch 10 UL Loads (Listed for Sway Braces) Sch 40 Dyna-Flow Mega-Flow Longitudinal Sch 10 Sch 40 CSBEZU0200EG 13340 N N/A 13340 N 13340 N N/A N/A N/A N/A CSBEZU0250EG 13340 N N/A 13340 N 13340 N 5620 N N/A 5620 N 5620 N CSBEZU0300EG 13340 N N/A 13340 N 13340 N 5620 N N/A 5620 N 5620 N CSBEZU0400EG 13340 N 13340 N 13340 N 13340 N 5620 N N/A 5620 N 5620 N CSBEZU0500EG N/A 13340 N 13340 N 13340 N N/A 7110 N 7110 N 7110 N CSBEZU0600EG N/A 13340 N 13340 N 13340 N N/A 7110 N 7110 N 7110 N FM Loads (Lightwall, Sch 10 and Sch 40 s) Horizontal Capacity per Installation Angle from Vertical Lateral Longitudinal 30-44 45-59 60-74 75-90 30-44 45-59 60-74 75-90 CSBEZU0100EG 3825 N 5425 N 6670 N 7430 N 1735 N 2445 N 2980 N 3335 N CSBEZU0125EG 3825 N 5425 N 6670 N 7430 N 1735 N 2445 N 2980 N 3335 N CSBEZU0150EG 3825 N 5425 N 6670 N 7430 N 1735 N 2445 N 2980 N 3335 N CSBEZU0200EG 6805 N 9610 N 11790 N 13165 N 2315 N 3070 N 3690 N 4136 N CSBEZU0250EG 6805 N 9610 N 11790 N 13165 N 2315 N 3070 N 3690 N 4136 N CSBEZU0300EG 6805 N 9610 N 11790 N 13165 N 2315 N 3070 N 3690 N 4136 N CSBEZU0400EG 6985 N 9875 N 12100 N 13480 N 2800 N 4005 N 4895 N 5470 N CSBEZU0500EG 6985 N 9875 N 12100 N 13480 N 2800 N 4005 N 4895 N 5470 N CSBEZU0600EG 8805 N 12500 N 15300 N 17080 N 3245 N 4450 N 5470 N 6095 N 12 www.erico.com

Standard Universal Sway Brace Use for both lateral and longitudinal sway brace applications Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Slotted design grabs service pipe for added gripping strength Meets NFPA -13 requirements for seismic sway bracing Article Number Pipe Size NB/DN A B Listings Approvals CSBSTU0100EG 404385 1" 25 mm 174,6 mm 25 mm UL, FM CSBSTU0125EG 404386 1 1/4" 32 mm 187,4 mm 25,4 mm UL, FM CSBSTU0150EG 404387 1 1/2" 40 mm 196,9 mm 25,4 mm UL, FM CSBSTU0200EG 404388 2" 50 mm 206,4 mm 30,2 mm UL, FM CSBSTU0250EG 404389 2 1/2" 65 mm 225,4 mm 30,2 mm cul, UL, FM CSBSTU0300EG 404390 3" 80 mm 238,1 mm 30,2 mm cul, UL, FM CSBSTU0400EG 404391 4" 100 mm 269,9 mm 38,1 mm cul, UL, FM CSBSTU0500EG 404392 5" 125 mm 308 mm 38,1 mm cul, UL, FM CSBSTU0600EG 404393 6" 150 mm 346,1 mm 50,8 mm cul, UL, FM CSBSTU0800EG 404394 8" 200 mm 400,1 mm 50,8 mm cul, UL, FM CSBSTU1000EG 404395 10" 250 mm 457,2 mm 50,8 mm cul, UL, FM Finish: Hot-dip galvanized CSBSTU0100HD 1" 25 mm 174,6 mm 25 mm UL, FM CSBSTU0125HD 1 1/4" 32 mm 187,4 mm 25,4 mm UL, FM CSBSTU0150HD 1 1/2" 40 mm 196,9 mm 25,4 mm UL, FM CSBSTU0200HD 2" 50 mm 206,4 mm 30,2 mm UL, FM CSBSTU0300HD 3" 80 mm 238,1 mm 30,2 mm cul, UL, FM CSBSTU0400HD 4" 100 mm 269,9 mm 38,1 mm cul, UL, FM CSBSTU0500HD 5" 125 mm 308 mm 38,1 mm cul, UL, FM CSBSTU0600HD 6" 150 mm 346,1 mm 50,8 mm cul, UL, FM CSBSTU0800HD 8" 200 mm 400,1 mm 50,8 mm cul, UL, FM CSBSTU1000HD 10" 250 mm 457,2 mm 50,8 mm cul, UL, FM UL Loads (Listed for Restraints) Dyna-Flow Sch 10 Sch 40 CSBSTU0100xx N/A 2910 N 2910 N CSBSTU0125xx 2910 N 2910 N 2910 N CSBSTU0150xx 2910 N 2910 N 2910 N www.erico.com 13

Dyna-Flow EZ FLOW Lateral Sch 10 UL Loads (Listed for Sway Braces) Sch 40 Dyna-Flow EZ FLOW Longitudinal Sch 10 Sch 40 CSBSTU0200xx 13340 N N/A 13340 N 13340 N N/A N/A N/A N/A CSBSTU0250xx 13340 N N/A 13340 N 13340 N 8960 N N/A 8960 N 8960 N CSBSTU0300xx 13340 N N/A 13340 N 13340 N 8960 N N/A 8960 N 8960 N CSBSTU0400xx 13340 N 13340 N 13340 N 13340 N 8960 N N/A 8960 N 8960 N CSBSTU0500xx N/A 13340 N 13340 N 13340 N N/A N/A 8960 N 8960 N CSBSTU0600xx N/A 13340 N 13340 N 13340 N N/A 8960 N 8960 N 8960 N CSBSTU0800xx N/A N/A 13340 N 13340 N N/A N/A 13340 N 13340 N CSBSTU1000xx N/A N/A 13340 N 13340 N N/A N/A 13340 N 13340 N FM Loads (Lightwall, Sch 10 and Sch 40 s) Horizontal Capacity per Installation Angle from Vertical Lateral Longitudinal 30-44 45-59 60-74 75-90 30-44 45-59 60-74 75-90 CSBSTU0100xx 3825 N 5425 N 6670 N 7430 N 4315 N 3200 N 3825 N 4270 N CSBSTU0125xx 3825 N 5425 N 6670 N 7430 N 4315 N 3200 N 3825 N 4270 N CSBSTU0150xx 3825 N 5425 N 6670 N 7430 N 4315 N 3200 N 3825 N 4270 N CSBSTU0200xx 6805 N 9610 N 11790 N 13165 N 3870 N 3070 N 3690 N 4136 N CSBSTU0250xx 6805 N 9610 N 11790 N 13165 N 3870 N 3070 N 3690 N 4136 N CSBSTU0300xx 6805 N 9610 N 11790 N 13165 N 3870 N 3070 N 3690 N 4136 N CSBSTU0400xx 6985 N 9875 N 12100 N 13480 N 6895 N 6185 N 7475 N 8320 N CSBSTU0500xx 6985 N 9875 N 12100 N 13480 N 6895 N 6185 N 7475 N 8320 N CSBSTU0600xx 8805 N 12500 N 15300 N 17080 N 6540 N 5205 N 6270 N 6985 N FM Loads (4.8 mm wall and Sch 40 s) Horizontal Capacity per Installation Angle from Vertical Lateral Longitudinal 30-44 45-59 60-74 75-90 30-44 45-59 60-74 75-90 CSBSTU0800xx 9075 N 12855 N 15745 N 17570 N 5340 N 7560 N 9295 N 10365 N CSBSTU1000xx 9075 N 12855 N 15745 N 17570 N 5340 N 7560 N 9295 N 10365 N 14 www.erico.com

Quick Grip Jr. Lateral Sway Brace Easy two-step installation elminates extra trips between structure and service pipe Works with 1" and 1 1/4" (25 mm and 32 mm) brace pipes to reduce inventory Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Meets NFPA -13 requirements for seismic sway bracing Article Number Pipe Size NB/DN CSBQIKCL0100EG 404373 1" 25 mm 130,2 mm 65,3 mm CSBQIKCL0125EG 404374 1 1/4" 32 mm 136,5 mm 74,4 mm CSBQIKCL0150EG 404375 1 1/2" 40 mm 142,9 mm 80,2 mm CSBQIKCL0200EG 404376 2" 50 mm 161,9 mm 92,3 mm Height H Width W UL Loads (Listed for Restraints) CSBQIKCL0100EG CSBQIKCL0125EG CSBQIKCL0150EG CSBQIKCL0200EG Lateral Schedule 25 mm Brace Pipe 32 mm Brace Pipe Dyna-Flow N/A N/A 10 2910 N 2910 N 40 2910 N 2910 N Dyna-Flow 2910 N 2400 N 10 2910 N 2400 N 40 2910 N 2400 N Dyna-Flow 3330 N 2910 N 10 3330 N 2910 N 40 3330 N 2910 N Dyna-Flow 3330 N 2400 N 10 3330 N 2400 N 40 3330 N 2400 N www.erico.com 15

FM Loads Lateral CSBQIKCL0100EG CSBQIKCL0125EG CSBQIKCL0150EG CSBQIKCL0200EG Schedule Horizontal per Installation Angle from Vertical 30-44 45-59 60-74 75-90 Lightwall 1290 N 1830 N 2200 N 2445 N 10 665 N 935 N 1245 N 1400 N 40 2115 N 2960 N 3670 N 4115 N Lightwall 1290 N 1830 N 2200 N 2445 N 10 665 N 935 N 1245 N 1400 N 40 2115 N 2960 N 3670 N 4115 N Lightwall 1290 N 1830 N 2200 N 2445 N 10 665 N 935 N 1245 N 1400 N 40 2115 N 2960 N 3670 N 4115 N Lightwall 1735 N 2445 N 2980 N 3335 N 10 1555 N 2225 N 2760 N 3070 N 40 2180 N 3070 N 3780 N 4225 N Quick Grip Lateral Sway Brace The Quick Grip Lateral Brace, part of the CADDY line of fire sprinkler bracing systems from ERICO, is designed to help simplify installations when bracing service pipe for seismic or other catastrophic events. It features an innovative design for quick attachment of brace pipe to service pipe saving time and money. Easy two-step installation elminates extra trips between structure and service pipe Works with 1" and 1 1/4" (25 mm and 32 mm) brace pipes to reduce inventory Yellow tips provide a visual indicator that the bolts have been properly torqued Easy installation with an impact wrench from the bottom side of the clamp Meets NFPA -13 requirements for seismic sway bracing Article Number Pipe Size NB/DN CSBQG0250EG 404468 2 1/2" 65 mm 138,1 148,6 mm 172 mm CSBQG0300EG 404469 3" 80 mm 155 165,5 mm 190 mm CSBQG0400EG 404470 4" 100 mm 180,4 190,9 mm 222 mm CSBQG0500EG 404471 5" 125 mm 205,8 217,9 mm 260 mm CSBQG0600EG 404472 6" 150 mm 235,5 244,9 mm 298 mm CSBQG0800EG 404473 8" 200 mm 289,2 300 mm 351,8 mm Height H Width W 16 www.erico.com

UL Loads CSBQG0250EG CSBQG0300EG CSBQG0400EG CSBQG0500EG CSBQG0600EG CSBQG0800EG Lateral Schedule 25 mm Brace Pipe 32 mm Brace Pipe Dyna-Flow 8960 N 8960 N 10 8960 N 8960 N 40 8960 N 8960 N Dyna-Flow 8960 N 8960 N 10 8960 N 8960 N 40 8960 N 8960 N Dyna-Flow 8960 N 8960 N 10 8960 N 8960 N 40 8960 N 8960 N 10 8960 N 8960 N 40 8960 N 8960 N Mega-Flow 8960 N 8960 N 10 8960 N 8960 N 40 8960 N 8960 N 10 8960 N 8960 N 40 8960 N 8960 N FM Loads Lateral CSBQG0250EG CSBQG0300EG CSBQG0400EG CSBQG0500EG CSBQG0600EG CSBQG0800EG Schedule Horizontal Capacity per Installation Angle from Vertical 30-44 45-59 60-74 75-90 Lightwall 6270 N 8895 N 10900 N 12190 N 10 6270 N 8895 N 10900 N 12190 N 40 6270 N 8895 N 10900 N 12190 N Lightwall 5295 N 7475 N 9163 N 10230 N 10 5295 N 7475 N 9163 N 10230 N 40 5295 N 7475 N 9163 N 10230 N Lightwall 5295 N 7475 N 9163 N 10230 N 10 5295 N 7475 N 9163 N 10230 N 40 5295 N 7475 N 9163 N 10230 N Lightwall 3870 N 5470 N 6715 N 7515 N 10 3870 N 5470 N 6715 N 7515 N 40 4315 N 6095 N 7475 N 8320 N Lightwall 3870 N 5470 N 6715 N 7515 N 10 3870 N 5470 N 6715 N 7515 N 40 4315 N 6095 N 7475 N 8320 N 4.8 mm (Wall Thickness) 3515 N 4940 N 6050 N 6760 N 40 3515 N 4940 N 6050 N 6760 N www.erico.com 17

Cable Bracing CADDY cable bracing is an ideal alternative to rigid bracing for fire sprinkler systems when brace lengths greater than 19-8 (6 m) are required or when confined/crowded spaces make rigid systems difficult to install. The system includes pre-stretched steel cable, attachment fittings, crimping sleeves and related tools. The system can also be used to brace electrical, mechanical and plumbing systems. Color-coated cable conforms to NFPA 13 requirements and makes it highly visible and easier to identify cable sizes UL Listed OSHPD Pre-Approved (OPA-0619) Cable Spool Crimping Sleeve Loop Attachment Kit No Pry Clip Stake Eye Kit Cable Cutter 18 www.erico.com

Swaging Tools Universal Restraint Clip Universal Restraint Clip, Retrofit Cable Spool Cut to length as needed Pre-stretched restraint cable Finish: Pre-galvanized, Painted Article Number Brace Size Diameter Cable Length UL Listed Load Color CSB12CBL 402190 #12 2,4 mm 76,2 m 2.668 N Red CSB18CBL 402191 #18 3,2 mm 76,2 m 4.893 N White CSB36CBL 402192 #36 4,8 mm 76,2 m 12.455 N Blue CSB48CBL 402193 #48 6 mm 76,2 m 20.461 N Yellow Cable is powder coated. www.erico.com 19

Crimping Sleeve Creates secure loop ends Crimp with swaging tools Material: Copper Article Number Brace Size CSB12SLVB 402194 #12 CSB18SLVB 402195 #18 CSB36SLVB 402196 #36 CSB48SLVB 402197 #48 Two side-by-side crimps required on #12 and #18 cable. Three side-by-side crimps required on #36 and #48 cable. Check crimp with gauge (not included). Loop Attachment Kit Two-way bracing kit with crimp sleeves Wraps around structural steel members Article Number Brace Size Brace Length Cable Length UL Listed Load Color CSB12B00L7 402230 #12 2,1 m 3,3 m 2.668 N Red CSB12B00L10 402232 #12 3,0 m 4,2 m 2.668 N Red CSB18B00L7 402231 #18 2,1 m 3,3 m 4.893 N White CSB18B00L10 402233 #18 3,0 m 4,2 m 4.893 N White Stake eyes not included. 20 www.erico.com

No Pry Clip Eliminates prying effect on fasteners and anchors Article Number Brace Size Hole Size UL Listed Load CSBNPC12 402208 #12, #18, #36 14 mm 12.460 N Stake Eye Kit Attaches to steel, wood or concrete structures Two-way bracing kit with crimp sleeves and stake eyes Swaged-on stake eye, pre-bent to 45 degrees Article Number Brace Size Hole Size Brace Length Cable Length UL Listed Load Color CSB12BD38L7 402218 #12 11 mm 2,1 m 3,3 m 2.668 N Red CSB12BD38L10 402221 #12 11 mm 3,0 m 4,2 m 2.668 N Red CSB12BD50L7 402224 #12 14 mm 2,1 m 3,3 m 2.668 N Red CSB12BD50L10 402227 #12 14 mm 3,0 m 4,2 m 2.668 N Red CSB18BD38L7 402219 #18 11 mm 2,1 m 3,3 m 4.893 N White CSB18BD38L10 402222 #18 11 mm 3,0 m 4,2 m 4.893 N White CSB18BD50L7 402225 #18 14 mm 2,1 m 3,3 m 4.893 N White CSB18BD50L10 402228 #18 14 mm 3,0 m 4,2 m 4.893 N White CSB36BD38L7 402220 #36 11 mm 2,1 m 3,3 m 12.455 N Blue www.erico.com 21

Article Number Brace Size Hole Size Brace Length Cable Length UL Listed Load Color CSB36BD38L10 402223 #36 11 mm 3,0 m 4,2 m 12.455 N Blue CSB36BD50L7 402226 #36 14 mm 2,1 m 3,3 m 12.455 N Blue CSB36BD50L10 402229 #36 14 mm 3,0 m 4,2 m 12.455 N Blue Kits contain copper sleeves. 22 www.erico.com

Swaging Tools Manual Swaging Tool Multi-Size Manual Swaging Tool Manual Swaging Tool Article Number Brace Size Listings CSB12SBHS 404461 #12 - CSB48 402212 #48 UL www.erico.com 23

Multi-Size Manual Swaging Tool Article Number Brace Size CSB3346SB 402209 #12, #18, #36 Universal Restraint Clip Attaches cable brace to structure Article Number Brace Size Hole Size HS UL Listed Load CSBURC38 402198 #12, #18, #36 11 mm 7.117 N CSBURC12 402199 #12, #18, #36 14 mm 7.117 N CSBURC58 402200 #12, #18, #36 17 mm 7.117 N CSBURC4812 402204 #48 14 mm 20.460 N CSBURC4858 402205 #48 17 mm 20.460 N CSBURC4834 402206 #48 21 mm 20.460 N Mount to the structure using the center hole. Loop cable through the holes in the bent tabs and crimp in place. For #48 cable, use two clips stacked together. 24 www.erico.com

Universal Restraint Clip, Retrofit Slotted design ideal for attaching to existing threaded rod on trapezes Article Number Brace Size CSBURCR38 402201 #12, #18 M10 CSBURCR12 402202 #12, #18 M12 CSBURCR58 402203 #12, #18 M16 Rod Size RS One fastener required for #12 cable. Two stacked fasteners required for #18 cable. www.erico.com 25

Branch Line Restraint System Traditional methods for installing branch line restraints in fire sprinkler systems are cumbersome and time-consuming. Contractors often cut (and re-cut) threaded rod to precise measurements to restrain the sprinkler pipe with a loop hanger and surge restraint. Traditional methods also commonly require five or more parts per restraint. To avoid these labor-intensive methods, ERICO has streamlined the process and developed the Branch Line Restraint System, part of the CADDY line of hanging and bracing solutions for the fire protection market. Ideal for restraining 1 (25 mm) through 2 (50 mm) branch lines, this innovative system is significantly faster and easier to install than current methods. It attaches directly to steel bar joists, I-beams or purlins, as well as concrete and wood structures. The hardware is installed with only one tool, a 5/16 (8 mm) socket drill driver, which provides significant labor savings and convenience. It features a simple, two-step installation process, allowing a time savings of up to 80% compared to other methods. Unlike most solutions that only accept 3/8 (M10) threaded rod, the versatile Branch Line Restraint System features a swivel attachment that can be rotated to accept 3/8 or 1/2 (M10 or M12) threaded rod. This allows greater restraint distances from the pipe to structure with 1/2 (M12) threaded rod. The system meets the requirements of NFPA 13, making it ideal for new construction applications. The total system is culus Listed and FM Approved, and has been pre-approved by the state of California (OSHPD OPA-2629-10). Complete restraint system is quick and easy to install Offers up to 80% time savings per branch line restraint Eliminates need to cut threaded rod to exact dimensions Works with 3/8 and 1/2 (M10 and M12) rod Capable of restraint distances up to 40 (960 mm) from pipe to structure with 1/2 (M12) threaded rod Meets requirements of NFPA 13 section 9.3.6 Branch Line Restraint Pipe Attachment Branch Line Restraint Structure Attachment to Steel Branch Line Restraint Structure Attachment to Wood/Concrete Branch Line Restraint Structure Attachment to Threaded Hole 26 www.erico.com

Branch Line Restraint Pipe Attachment Accepts 3/8 or 1/2 (M10 or M12) threaded rod Quick grip clamp simplifies measuring and cutting of threaded rod Works with rough-cut threaded rod and eliminates pipe-side deburring Can be installed with threaded rod above or below the service pipe Shear-off head helps ensure correct torque and simplifies inspection Article Number Pipe Size NB/DN Outer Diameter OD Rod Size RS CSBBRP0100EG 404477 1" 25 mm 33,4 mm M10, M12 169,4 mm 41,4 mm 22,2 mm CSBBRP0125EG 404478 1 1/4" 32 mm 42,2 mm M10, M12 192 mm 50 mm 22,2 mm CSBBRP0150EG 404479 1 1/2" 40 mm 48,3 mm M10, M12 208,4 mm 56,1 mm 22,2 mm CSBBRP0200EG 404480 2" 50 mm 60,3 mm M10, M12 240 mm 68,3 mm 22,2 mm Height H Length L Width W www.erico.com 27

Branch Line Restraint Structure Attachment to Steel Swivel connector accepts 3/8 or 1/2 (M10 or M12) threaded rod Attaches to steel members with self-drilling/tapping screw Article Number Rod Size RS Flange Thickness FT Height H Length L Width W Screw Diameter Sc Screw Length L CSBBRS1MEG 402239 M10, M12 2,7 12,7 mm 28,2 mm 40,4 mm 26,9 mm #12 32 mm Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. Branch Line Restraint Structure Attachment to Wood/Concrete Swivel connector accepts 3/8 or 1/2 (M10 or M12) threaded rod Attaches to wood or concrete structures Article Number Rod Size RS Height H Length L Width W Screw Diameter Sc Screw Length L Drill Bit Size CSBBRS2MEG 402240 M10, M12 28,2 mm 40,4 mm 26,9 mm 6,4 mm 45 mm 4,8 mm Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. 28 www.erico.com

Branch Line Restraint Structure Attachment to Threaded Hole Swivel connector accepts 3/8 or 1/2 (M10 or M12) threaded rod Attaches to concrete anchors or structural attachments with female threads Article Number Rod Size RS Height H Length L Width W Screw Diameter Sc Screw Length L CSBBRS3MEG 402241 M10, M12 28,2 mm 40,4 mm 26,9 mm M10 19 mm Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. www.erico.com 29

Rod Stiffeners Pipe Rod Stiffener Pipe Rod Stiffener For use with Schedule 40 or Schedule 10 pipe Secures pipe to threaded rod for stiffening Article Number Brace Pipe Size Brace NB/DN Rod Size CSBRS1 402207 1" 25 mm M10, M12, M16 30 www.erico.com

culus is a registered certification mark of UL LLC. Dyna-Flow is a registered trademark of Allied Tube & Conduit Corporation. EZ FLOW is a trademark of Northwest Pipe Company. FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL is a registered certification mark of UL LLC. WARNING ERICO products shall be installed and used only as indicated in ERICO s product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. WARRANTY ERICO products are warranted to be free from defects in material and workmanship at the time of shipment. NO OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCTS. Claims for errors, shortages, defects or nonconformities ascertainable upon inspection must be made in writing within 5 days after Buyer's receipt of products. All other claims must be made in writing to ERICO within 6 months from the date of shipment or transport. Products claimed to be nonconforming or defective must, upon ERICO's prior written approval in accordance with its standard terms and procedures governing returns, promptly be returned to ERICO for inspection. Claims not made as provided above and within the applicable time period will be barred. ERICO shall in no event be responsible if the products have not been stored or used in accordance with its specifications and recommended procedures. ERICO will, at its option, either repair or replace nonconforming or defective products for which it is responsible or return the purchase price to the Buyer. THE FOREGOING STATES BUYER S EXCLUSIVE REMEDY FOR ANY BREACH OF ERICO WARRANTY AND FOR ANY CLAIM, WHETHER SOUNDING IN CONTRACT, TORT OR NEGLIGENCE, FOR LOSS OR INJURY CAUSED BY THE SALE OR USE OF ANY PRODUCT. LIMITATION OF LIABILITY ERICO excludes all liability except such liability that is directly attributable to the willful or gross negligence of ERICO's employees. Should ERICO be held liable its liability shall in no event exceed the total purchase price under the contract. ERICO SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS OF BUSINESS OR PROFITS, DOWNTIME OR DELAY, LABOR, REPAIR OR MATERIAL COSTS OR ANY SIMILAR OR DISSIMILAR CONSEQUENTIAL LOSS OR DAMAGE INCURRED BY BUYER. Copyright 2013 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. www.erico.com 31